Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Moving toward a framework for electricity and heat equivalence in energy systems analysis

Sustaining, maintaining, and upgrading the electricity grid, while meeting decarbonization goals is a challenge facing policymakers, regulators, grid operators, and investors. Simultaneously meeting demands for future capacity, retiring older inefficient technologies, and addressing externalities from energy production and use requires more diverse and inclusive technologies to avoid constraints and shortfalls in grid capability. Changing the energy production paradigm by encouraging alternative technologies was a key driver for FERC Order 2222. This stimulus for developing new small-scale generation will complement and supplement the existing fleet only if it attracts new investment. This investment must reflect technology that goes beyond the energy-only characteristics of traditional generation, creating systems where suites of energy-equivalent outputs are enhanced by environmental quality benefits and offsets. We use energy system designs to highlight the contribution that measuring and accounting for equivalency values provides net increases in capacity, electricity, and alternative fuels while simultaneously reducing carbon waste impacts.

42 ENGINEERING↗

A Polymer-Assisted Spinodal Decomposition Strategy toward Interconnected Porous Sodium Super Ionic Conductor-Structured Polyanion-Type Materials and Their Application as a High-Power Sodium-Ion Battery Cathode

A general polymer-assisted spinodal decomposition strategy is used to prepare hierarchically porous sodium super ionic conductor (NASICON)-structured polyanion-type materials (e.g., Na 3 V 2 (PO 4 ) 3 , Li 3 V 2 (PO 4 ) 3 , K 3 V 2 (PO 4 ) 3 , Na 4 MnV(PO 4 ) 3 , and Na 2 TiV(PO 4 ) 3 ) in a tetrahydrofuran/ethanol/H 2 O synthesis system. Depending on the boiling point of solvents, the selective evaporation of the solvents induces both macrophase separation via spinodal decomposition and mesophase separation via self-assembly of inorganic precursors and amphiphilic block copolymers, leading to the formation of hierarchically porous structures. We find that the resulting hierarchically porous Na 3 V 2 (PO 4 ) 3 possessing large specific surface area (≈77 m 2 g -1 ) and pore volume (≈0.272 cm 3 g -1 ) shows a high specific capacity of 117.6 mAh g -1 at 0.1 C achieving the theoretical value and a long cycling life with 77% capacity retention over 1000 cycles at 5 C. This method presented here can open a facile avenue to synthesize other hierarchically porous polyanion-type materials.

36 MATERIALS SCIENCE↗

Quantitative Evaluation of CO 2 Storage Potential in the Offshore Atlantic Lower Cretaceous Strata, Southeastern United States

The geological storage of CO 2 in the Earth’s subsurface has the potential to significantly offset greenhouse gas emissions for safe, economical, and acceptable public use. Due to legal advantages and vast resource capacity, offshore CO 2 storage provides an attractive alternative to onshore options. Although offshore Lower Cretaceous reservoirs have a vast expected storage capacity, there is a limited quantitative assessment of the offshore storage resource in the southeastern United States. This work is part of the Southeast Offshore Storage Resource Assessment (SOSRA) project, which presents a high-quality potential geological repository for CO 2 in the Mid- and South Atlantic Planning Areas. This is the first comprehensive investigation and quantitative assessment of CO 2 storage potential for the Lower Cretaceous section of the outer continental shelf that includes the Southeast Georgia Embayment and most of the Blake Plateau. An interpretation of 200,000 km of legacy industrial 2D seismic reflection profiles and geophysical well logs (i.e., TRANSCO 1005-1-1, COST GE-1, and EXXON 564-1) were utilized to create structure and thickness maps for the potential reservoirs and seals. We identified and assessed three target reservoirs isolated by seals based on their effective porosity values. The CO 2 storage capacity of these reservoirs was theoretically calculated using the DOE-NETL equation for saline formations. The prospective storage resources are estimated between 450 and 4700 Mt of CO 2 , with an offshore geological efficiency factor of dolomite between 2% and 3.6% at the formation scale.

03 NATURAL GAS↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

Toward Complete Transformation of Sodium Polysulfides by Regulating the Second-Shell Coordinating Environment of Atomically Dispersed Fe

Room temperature sodium-sulfur (RT Na-S) batteries are highly competitive as potential energy storage devices. Nevertheless, their actually achieved reversible capacities are far below the theoretical value due to incomplete transformation of polysulfides. Herein, atomically dispersed Fe-N/S active center by regulating the second-shell coordinating environment of Fe single atom is proposed. The Fe-N4S2 coordination structure with enhanced local electronic concentration around the Fermi level is revealed via synchrotron radiation X-ray absorption spectroscopy (XAS) and theoretical calculations, which can not only significantly promote the transformation kinetics of polysulfides, but induce uniform Na deposition for dendrite-free Na anode. Here as a result, the obtained S cathode delivers a high initial reversible capacity of 1590 mAh g-1, nearly the theoretical value. Here this work opens up a new avenue to facilitate the complete transformation of polysulfides for RT Na-S batteries.

25 ENERGY STORAGE↗

Toward Complete Transformation of Sodium Polysulfides by Regulating the Second–Shell Coordinating Environment of Atomically Dispersed Fe

Room temperature sodium-sulfur (RT Na-S) batteries are highly competitive as potential energy storage devices. Nevertheless, their actually achieved reversible capacities are far below the theoretical value due to incomplete transformation of polysulfides. Herein, atomically dispersed Fe-N/S active center by regulating the second-shell coordinating environment of Fe single atom is proposed. The Fe–N 4 S 2 coordination structure with enhanced local electronic concentration around the Fermi level is revealed via synchrotron radiation X-ray absorption spectroscopy (XAS) and theoretical calculations, which can not only significantly promote the transformation kinetics of polysulfides, but induce uniform Na deposition for dendrite-free Na anode. As a result, the obtained S cathode delivers a high initial reversible capacity of 1590 mAh g –1 , nearly the theoretical value. Finally, this work opens up a new avenue to facilitate the complete transformation of polysulfides for RT Na-S batteries.

25 ENERGY STORAGE↗

Single-crystal NMC622 from combustion-assisted solid-state synthesis: Tunable particle size, voltage-dependent stability, and Li-ion diffusion

Cost-effective and scalable synthesis of single-crystal lithium–metal-oxide cathodes with controlled size and morphology remains challenging for advancing high-performance lithium-ion batteries. Here, we demonstrate a solution combustion–assisted solid-state method for producing single-crystal NMC622 with tunable particle size at various lithium stoichiometries. Structural and electronic characteristics were probed using synchrotron-XANES, EXAFS, XRD and XPS, confirming well-defined coordination environments and phase purity up to Li ≈ 1.3. The electrochemical behavior of LixNMC (x = 1.0 and 1.3) single crystals was evaluated across 2.8–4.3 V and 2.8–4.7 V windows to elucidate the effects of lithium content and operating voltage. At 2.8–4.3V, Li1.3NMC exhibits higher initial capacity due to its larger lithium inventory, while Li1.0NMC shows superior long-term retention driven by its larger crystal size and reduced structural distortion. Increasing the cutoff voltage to 4.7 V enhances the initial capacity of both compositions by 17–25%, but long-term capacity retention ultimately converges to values comparable to those at 4.3 V due to voltage-induced degradation, where Li+ diffusion constant remains lying ranging from 10−12 –10−11 cm2s−1. Overall, this study establishes a scalable combustion-assisted route for synthesizing tunable single-crystal NMC622 and highlights the interplay between lithium stoichiometry, particle size, and voltage window in governing cathode stability.

Roy, Subrata C [Jackson State University]↗

Lone-Electron-Pair Micelles Strengthen Bond Anharmonicity in MnPb16Sb14S38 Complex Sulfosalt Leading to Ultra-Low Thermal Conductivity

Designing crystalline solids in which intrinsic extremely low lattice thermal conductivity mainly arises from its unique bonding nature rather than structure complexity and/or atomic disorder could promote thermal energy manipulation and utilization for applications ranging from thermoelectric energy conversion to thermal barrier coatings. Here, we report an extremely low lattice thermal conductivity of ~0.34 W m-1 K-1 at 300 K in the new complex sulfosalt MnPb16Sb14S38. We attribute the ultra-low lattice thermal conductivity to a synergistic combination of scattering mechanisms involving (1) strong bond anharmonicity in various structural building units, owing to the presence of stereoactive lone-electron-pair (LEP) micelles, and (2) phonon scattering at the interfaces between building units of increasing size and complexity. Remarkably, low-temperature heat capacity measurement revealed a Cp value of 0.206 J g-1 K-1 at T > 300 K, which is 22% lower than the Dulong-Petit value (0.274 J g-1 K-1). Further analysis of the Cp data and sound velocity (ν = 1834 m/s) measurement yielded Debye temperature values of 161 K and 187 K, respectively. Here, the resulting Grüneisen parameter, γ = 1.65, further supports strong bond anharmonicity as the dominant mechanism responsible for the observed extremely low lattice thermal conductivity.

36 MATERIALS SCIENCE↗

Mild pH-decoupling aqueous flow battery with practical pH recovery

Establishing a pH difference between the two electrolytes (pH decoupling) of an aqueous redox flow battery (ARFB) enables cell voltages exceeding the 1.23 V thermodynamic water-splitting window, but acid–base crossover penalizes efficiency and lifetime. Here we employ mildly acidic and mildly alkaline electrolytes to mitigate crossover, achieving high round-trip energy efficiency with open circuit voltage >1.7 V. We implemented an acid–base regeneration system to periodically restore electrolytes to their initial pH values. The combined system exhibited capacity fade rate <0.07% per day, round-trip energy efficiency >85% and approximately 99% Coulombic efficiency during stable operation for over a week. Cost analysis shows that the tolerance of acid–base crossover could be increased if the pH-decoupling ARFB achieved a higher voltage output and lower resistance. Finally, this work demonstrates principles for improving lifespan, rate capability and energy efficiency in high-voltage pH-decoupling ARFBs and pH recovery concepts applicable for pH-decoupling systems.

25 ENERGY STORAGE↗

Theory of overparametrization in quantum neural networks

The prospect of achieving quantum advantage with quantum neural networks (QNNs) is exciting. Understanding how QNN properties (for example, the number of parameters $M$) affect the loss landscape is crucial to designing scalable QNN architectures. Here we rigorously analyze the overparametrization phenomenon in QNNs, defining overparametrization as the regime where the QNN has more than a critical number of parameters $M_c$ allowing it to explore all relevant directions in state space. In this study, our main results show that the dimension of the Lie algebra obtained from the generators of the QNN is an upper bound for $M_c$, and for the maximal rank that the quantum Fisher information and Hessian matrices can reach. Underparametrized QNNs have spurious local minima in the loss landscape that start disappearing when $M$ ≥ $M_c$. Thus, the overparametrization onset corresponds to a computational phase transition where the QNN trainability is greatly improved. We then connect the notion of overparametrization to the QNN capacity, so that when a QNN is overparametrized, its capacity achieves its maximum possible value.

97 MATHEMATICS AND COMPUTING↗

Chemomechanical effect of reduced graphene oxide encapsulation on hydrogen storage performance of Pd nanoparticles

Primary chemomechanical impacts of confinement on hydrogen storage performance are studied using a nanolaminate structure where reduced graphene oxide (rGO) encapsulates palladium (Pd) nanoparticles. Three contributing factors are identified that can alter the reaction enthalpy: nanosizing, chemical interaction with the encapsulant, and mechanical stress induced strain from a combination of clamping force and lateral pulling force exerted on the Pd nanoparticles. The mechanical contributions are quantified by combining transmission electron microscopy, ab initio computation, and continuum elasticity theory, from which the encapsulation is found to exert an additional strain of 4.96% and 2.99% before and after hydrogen absorption, respectively, increasing the Pd and Pd hydride (PdH x ) reaction enthalpy by 1.3–2.8 kJ (mol H 2 ) -1 . The effect of the chemical interaction with rGO also raises the reaction enthalpy by up to 1.6 kJ (mol H 2 ) -1 , while the nanosizing effect decreases the reaction enthalpy. The three contributing factors to the reaction enthalpy are found to be similar in magnitude, where the net effect is in agreement with the measured enthalpy increase of 3.7 kJ (mol H 2 ) -1 from the bulk value. Hydrogen absorption kinetics and capacity also improved, which is attributed to facile nucleation of the hydrogen-rich phase enabled by the inhomogeneous strain distribution over the encapsulated PdHx nanoparticles. These results demonstrate that the chemomechanical effect can be controlled in the nanolaminate structure, providing an ideal template for tuning hydrogen storage performance.

08 HYDROGEN↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

microbasekaplus.c1

This microbasekaplus datastream is produced by re-writed micorbaseka vap (microbasekaplus) in python under ADI framewrok, and added uncertainties for the microphysics. The original Microbase VAP was developed in 2002. The primary purpose of producing this VAP was to provide the required microphysical values for input to the Broad Band Heating Rate Profiles (BBHRP) VAP in order to generate estimations of radiative heating rates. It served the Radiatively Important Parameters Best Estimate (RIBPE) VAP in the capacity of providing baseline cloud microphysical values as input. Microbase produces cloud microphysical properties based on cloud radar measurements taken at all fixed ARM sites.

54 ENVIRONMENTAL SCIENCES↗

Synthesis of historical reservoir operations from 1980 to 2020 for the evaluation of reservoir representation in large-scale hydrologic models

Abstract. All the major river systems in the contiguous United States (CONUS) (and many in the world) are impacted by dams, yet reservoir operations remain difficult to quantify and model due to a lack of data. Reservoir operation data are often inaccessible or distributed across many local operating agencies, making the acquisition and processing of data records quite time-consuming. As a result, large-scale models often rely on simple parameterizations for assumed reservoir operations and have a very limited ability to evaluate how well these approaches match actual historical operations. Here, we use the first national dataset of historical reservoir operations in the CONUS domain, ResOpsUS, to analyze reservoir storage trends and operations in more than 600 major reservoirs across the US. Our results show clear regional differences in reservoir operations. In the eastern US, which is dominated by flood control storage, we see storage peaks in the winter months with sharper decreases in the operational range (i.e., the difference between monthly maximum and minimum storage) in the summer. In the more arid western US where storage is predominantly for irrigation, we find that storage peaks during the spring and summer with increases in the operational range during the summer months. The Lower Colorado region is an outlier because its seasonal storage dynamics more closely mirrored those of flood control basins, yet the region is classified as arid, and most reservoirs have irrigation uses. Consistent with previous studies, we show that average annual reservoir storage has decreased over the past 40 years, although our analyses show a much smaller decrease than previous work. The reservoir operation characterizations presented here can be used directly for development or evaluation of reservoir operations and their derived parameters in large-scale models. We also evaluate how well historical operations match common assumptions that are often applied in large-scale reservoir parameterizations. For example, we find that 100 dams have maximum storage values greater than the reported reservoir capacity from the Global Reservoirs and Dams database (GRanD). Finally, we show that operational ranges have been increasing over time in more arid regions and decreasing in more humid regions, pointing to the need for operating policies which are not solely based on static values.

Geology↗