Search NASASearch

SEARCH · Search NASA

Results for “instrument method optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advanced Fuels Campaign Execution Plan

The Advanced Fuels Campaign (AFC) Execution Plan outlines the strategy, mission, scope, near-term and long-term goals, structure, and organization associated with nuclear fuels and materials research, development, and demonstration activities within the Department of Energy’s (DOE) Nuclear Fuel Cycle and Supply Chain (NFCSC) program. NFCSC has been given responsibility to identify and mature advanced fuel technologies for the DOE using a science-based approach, focused on developing a fundamental understanding of nuclear fuels and materials to drive development of integrated nuclear fuel and materials technology. This science-based approach combines theory, experiments, and multiscale modeling and simulation to achieve a predictive understanding of relevant behaviors ranging from fuel fabrication processes (and their resulting fuel microstructures) through fuel/cladding performance under irradiation (in contrast to more empirical, observation-based approaches frequently used in fuel performance modeling and fuel qualification). The traditional scope of AFC includes the evaluation and development of multiple fuel forms to support two fuel cycle options: once-through and full recycle. The word “fuel” is used generically to include conventional fuels, transmutation targets, and any associated cladding or duct materials. The once-through fuel cycle addresses advanced light water reactor fuels with enhanced performance, extended burnup, and reduced waste generation. In fiscal year (FY) 2012, AFC’s scope expanded to include research, development, and demonstration (RD&D) for light water reactor (LWR) fuels with enhanced accident tolerance. Fuel fabrication activities include the development of innovative methods to enhance process efficiencies, reduce waste, and improve control over as-fabricated fuel microstructural properties to achieve desired in-reactor performance. Using modern modeling and simulation approaches, the objective is to predict fresh fuel properties given the feedstock characteristics and fabrication process parameters. The performance-related activities include small-scale, in-reactor, and out-of-reactor phenomenological testing (distinct from, but synergistic with, integral prototypic testing) and extensive, quantitative characterization (focusing on characterization of fuel and cladding materials at the scale of microstructure) both before and after testing. Larger-scale, prototypic experiments are conducted in concert with phenomenological testing to drive a Fuel Development and Qualification program, incorporating a fundamental understanding of fuel behavior performance characteristics. Then, using the tools developed under the productive science-based approach, fuels will be optimized to meet specific performance requirements, thereby minimizing the need to repeatedly perform large-scale, integral experiments over a wide parametric range as a means of experimental exploration. Two significant initiatives are underway within AFC. First, a gap analysis completed in early FY 2019 identified critical irradiation testing needs that are lacking within the national light water reactor (LWR) fuels testbed since the shutdown of the Halden Reactor in 2018. The identified gaps are for instrumented, prototypic testing of LWR fuels, especially under boiling water reactor conditions, ramp conditions, and conditions leading to fuel failure; these needs exist for supporting current LWR fuels and their possible extension to higher burnups, but are especially urgent relative to near-term development and qualification of accident-tolerant fuels. Recommendations that resulted from the Halden Gap Analysis focused on enhancements at Advanced Test Reactor (ATR) and Transient Reactor Test Facility (TREAT) to fill gaps in testing capabilities relative to these needs. Second, a concerted effort to develop and demonstrate a systematic approach to accelerating the development, testing, and qualification of new fuel systems has been initiated. This is highlighted by a test strategy that combines the considerable advances in multiscale, mechanistic fuel modeling of recent years with a MiniFuel separate effects test program in the High Flux Isotope Reactor (HFIR) and a Fission Accelerated Steady-state Testing (FAST) semi-integral accelerated test program in ATR. This approach is being tested/demonstrated using the metallic fuel system, but if successful it is expected to be extensible to multiple fuel types and diverse applications. This document includes an overview of the NFCSC program, a definition of science-based development of nuclear fuels, near-term goals for Advanced LWR fuels (ALFs), and longer-term goals for Advanced Reactor Fuels (ARFs) RD&D. This includes the activities that will be conducted to achieve success toward the grand challenge, as well as the goals and milestones to be achieved over the next few decades of research and development. Long-term goals are based on the DOE Office of Nuclear Energ

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Advanced Data Science Model for Detecting Intelligent Malware

This study focused on developing a robust artificial intelligence (AI) model capable of detecting and characterizing advanced malware in Internet of Things (IoT) devices using network data. By analyzing network traffic with various machine learning (ML) models, our AI model can identify and characterize malicious activities to significantly improve malware detection accuracy and reliability as compared to traditional methods. The developed AI/ML model was trained using network data from IoT devices, leveraging classifiers such as Random Forest, Gradient Boosting, AdaBoost, and others to optimize detection performance. This project demonstrates a scalable framework for real-time malware detection and characterization in IoT networks, capable of identifying infected devices and facilitating the necessary steps to remove or isolate them, thereby preventing further infections. Although digital twin (DT) integration is not yet implemented in the current model, it represents a promising future enhancement. By creating a virtual replica of physical IoT devices, DT technology would allow for real-time monitoring and analysis without directly accessing operational technology, thus reducing the risk of compromising or reducing the performance of actual devices. This integration would further enhance the security of IoT ecosystems, combining AI technology to better flag and detect indications of malware-infected devices within a nuclear system environment.

42 ENGINEERING

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation

Modeling and Design Parameter Optimization to Improve the Sensitivity of a Bimorph Polysilicon-Based MEMS Sensor for Helium Detection

Helium is integral in several industries, including nuclear waste management and semiconductors. Thus, developing a sensing method for detecting helium is essential to ensure the proper operation of such facilities. Several approaches can be used for helium detection, including based on the high thermal conductivity of helium, which is several times higher than air. This work utilizes the high thermal conductivity of helium to design and analyze a bimorph MEMS sensor for helium sensing applications. COMSOL Multiphysics software (version 6.2) is used to carry out this investigation. The sensor is constructed from poly-silicon and SiO 2 materials with a trenched cantilever beam configuration. The sensor is electrically heated, and its morphed displacement depends on the surrounding gas’s composition, which decreases in the presence of helium. Several factors were investigated to probe their effect on the sensor’s sensitivity to helium, including the thickness of the poly-silicon layer, the configuration of the trench, and the thickness and location of SiO 2 layer. The simulations showed that the best performance, up to 2 ppm helium detection level, can be achieved with thinner beams and medium trench lengths.

47 OTHER INSTRUMENTATION

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

AEPF: Attention-Enabled Point Fusion for 3D Object Detection

Current state-of-the-art (SOTA) LiDAR-only detectors perform well for 3D object detection tasks, but point cloud data are typically sparse and lacks semantic information. Detailed semantic information obtained from camera images can be added with existing LiDAR-based detectors to create a robust 3D detection pipeline. With two different data types, a major challenge in developing multi-modal sensor fusion networks is to achieve effective data fusion while managing computational resources. With separate 2D and 3D feature extraction backbones, feature fusion can become more challenging as these modes generate different gradients, leading to gradient conflicts and suboptimal convergence during network optimization. To this end, we propose a 3D object detection method, Attention-Enabled Point Fusion (AEPF). AEPF uses images and voxelized point cloud data as inputs and estimates the 3D bounding boxes of object locations as outputs. An attention mechanism is introduced to an existing feature fusion strategy to improve 3D detection accuracy and two variants are proposed. These two variants, AEPF-Small and AEPF-Large, address different needs. AEPF-Small, with a lightweight attention module and fewer parameters, offers fast inference. AEPF-Large, with a more complex attention module and increased parameters, provides higher accuracy than baseline models. Experimental results on the KITTI validation set show that AEPF-Small maintains SOTA 3D detection accuracy while inferencing at higher speeds. AEPF-Large achieves mean average precision scores of 91.13, 79.06, and 76.15 for the car class’s easy, medium, and hard targets, respectively, in the KITTI validation set. Results from ablation experiments are also presented to support the choice of model architecture.

Chemistry

Microjet printing of metal salt or oxide targets for nuclear reaction studies on radionuclides

Radioactive targets for direct measurements of neutron-induced reactions are required to improve evaluated cross-section data and, ultimately, the fidelity of neutron reaction network simulations. Electrodeposition and molecular plating are the current state-of-the-art radioactive target production techniques, but not all metals can be electrodeposited or molecular plated with high yields. Alternative techniques can be expensive or may produce targets that are unsatisfactory in terms of thickness, yield, or purity. Microjet printing is a new, rather inexpensive technique that utilizes equipment with a small footprint and has the potential to produce thin, highly radioactive targets with good uniformity and minimal impurities from the target fabrication process. This study involved optimizing the process of producing microjet printed targets to allow for the fabrication of a stable vanadium(V) oxide (V 2 O 5 ) target that was compared with an analogous electrodeposition V 2 O 5 target manufactured via the application of a vanadium chemical conversion coating on aluminum (Al) foil. Finally, the results from these studies suggest microjet printing could be used to produce relatively uniform target layers with adequate film thicknesses (< 15 μm). V 2 O 5 microjet printed targets, when compared with chemical conversion coating V 2 O 5 targets, appeared to be qualitatively less uniform and quantitatively larger in thickness (11.7(27) μm vs. 5.3(18) μm). However, the conversion coating target contained more impurities and the Al backing had a higher background contribution to measurements of neutron-induced reactions as opposed to targets produced via microjet printing. Overall, the results from this study suggest microjet printing has the capability to be an excellent alternative target production technique to the electrodeposition and molecular plating methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION

CIRCLEZ : Reliable photometric redshifts for active galactic nuclei computed solely using photometry from Legacy Survey Imaging for DESI

Photometric redshifts for galaxies hosting an accreting supermassive black hole in their center, known as active galactic nuclei (AGNs), are notoriously challenging. At present, they are most optimally computed via spectral energy distribution (SED) fittings, assuming that deep photometry for many wavelengths is available. However, for AGNs detected from all-sky surveys, the photometry is limited and provided by a range of instruments and studies. This makes the task of homogenizing the data challenging, presenting a dramatic drawback for the millions of AGNs that wide surveys such as SRG/eROSITA are poised to detect. This work aims to compute reliable photometric redshifts for X-ray-detected AGNs using only one dataset that covers a large area: the tenth data release of the Imaging Legacy Survey (LS10) for DESI. LS10 provides deep grizW1-W4 forced photometry within various apertures over the footprint of the eROSITA-DE survey, which avoids issues related to the cross-calibration of surveys. We present the results from CIRCLEZ, a machine-learning algorithm based on a fully connected neural network. CIRCLEZ is built on a training sample of 14 000 X-ray-detected AGNs and utilizes multi-aperture photometry, mapping the light distribution of the sources. The accuracy (σNMAD) and the fraction of outliers (η) reached in a test sample of 2913 AGNs are equal to 0.067 and 11.6%, respectively. The results are comparable to (or even better than) what was previously obtained for the same field, but with much less effort in this instance. We further tested the stability of the results by computing the photometric redshifts for the sources detected in CSC2 and Chandra-COSMOS Legacy, reaching a comparable accuracy as in eFEDS when limiting the magnitude of the counterparts to the depth of LS10. The method can be applied to fainter samples of AGNs using deeper optical data from future surveys (for example, LSST, Euclid), granting LS10-like information on the light distribution beyond the morphological type. Along with this paper, we have released an updated version of the photometric redshifts (including errors and probability distribution functions) for eROSITA/eFEDS.

79 ASTRONOMY AND ASTROPHYSICS

Ionization effects in single-shot carrier-envelope phase detection with gas-gap devices

The carrier-envelope phase (CEP) is a key parameter for attosecond waveform control of ultrashort laser pulses. For laser systems with high repetition rates, however, single-shot CEP detection is still challenging. Building on recent findings on phase detection with electric current generation in gases, we show that with an optimized detection method, a long-term stable single-shot phase detection is feasible. We investigate the achievable performance depending on various parameters such as pulse duration, gas pressure, or incident intensity. The latter exhibits a regime where the saturation of the ionization process boosts the phase sensitivity of the signal, which is elucidated by numerical calculations.

47 OTHER INSTRUMENTATION

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION

A Sensitive Electrochemical Cholinesterase-Inhibiting Biosensor for Organophosphorus Pesticides Based on Ti 3 C 2 TX MXene Quantum Dots

Organophosphorus pesticides (OPs) pose significant environmental and health risks due to their widespread use and toxicity, primarily by inhibiting acetylcholinesterase. Traditional detection methods are often slow and costly, highlighting the urgent need for advanced, sensitive, and accessible technologies. This study developed a highly sensitive electrochemical cholinesterase-inhibiting biosensor for OP pesticides, utilizing Ti 3 C 2 T x MXene Quantum Dots (MQDs), which was synthesized via a hydrothermal method. The biosensor’s performance was characterized using electrochemical impedance spectroscopy, differential pulse voltammetry (DPV), and cyclic voltammetry. DPV proved to be the optimal technique, exhibiting an ultralow detection limit of 1 × 10 −17 M and a wide linear range (10 −14 –10 −8 M) for chlorpyrifos (a model OP) with an estimated inhibition constant of 62 nM. The biosensor demonstrated high selectivity for OPs (chlorpyrifos, acephate, glyphosate) over a non-target pyrethroid (permethrin), confirmed by distinct electrochemical signatures and compared to in vitro cholinergic activity assays in bean beetle homogenates. The enhanced performance is attributed to the high surface-to-volume ratio, quantum confinement effects, and superior conductivity of the MQDs, as well as the robust enzyme immobilization facilitated by glutaraldehyde cross-linking and a chitosan matrix. This work presents a promising platform for rapid, sensitive, and selective detection of OP pesticides, with potential applications in environmental monitoring and public health protection.

Chemistry

Leveraging Radiofrequency Identification Success Beyond Hazardous Material Inventory Management at a National Laboratory

Effective inventory management can be overshadowed by conflicting priorities in organizational procedures, particularly in research-focused institutions such as national laboratories that handle expensive, delicate, and hazardous materials. Here, this study investigated the potential of radiofrequency identification (RFID) technology, currently used for hazardous chemical inventory, in applications with higher metal interference and absorption, specifically pressure release device (PRD) compliance and nuclear container management, at Lawrence Livermore National Laboratory (LLNL). This study was done to document best practices to enhance inventory identification speeds for inventory reconciliation and inventory recall and to explore optimal configurations for RFID implementation compared to traditional manual methods of equipment management. Tests were conducted to determine the ideal RFID tag orientation (read at angles of 0°, 90°, and 270°), various container layouts (linear, separated, curved, operational), and ID methods such as manual, barcode, and RFID performing three trials per method per orientation. Results indicated that 0° was the optimal read angle for minimizing metallic interference, and the operational and curved arrangements significantly outperformed the linear and separated configurations in read speed. 3D printed mounts were developed and tested, increasing the read range of the RFID reader by up to 235% in cases of high metallic interference. The RFID technology demonstrated an average speed increase of 65% over a simplified manual identification, which supports the conclusion that RFID is a more efficient method for large hazardous inventory management and equipment reconciliation. Additionally, capturing meta-data, such as location and date, can be used to query for inventory recall and automated updating of record information.

42 ENGINEERING

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION

Contrastive Machine Learning with Gamma Spectroscopy Data Augmentations for Detecting Shielded Radiological Material Transfers

Data analysis techniques can be powerful tools for rapidly analyzing data and extracting information that can be used in a latent space for categorizing observations between classes of data. Machine learning models that exploit learned data relationships can address a variety of nuclear nonproliferation challenges like the detection and tracking of shielded radiological material transfers. The high resource cost of manually labeling radiation spectra is a hindrance to the rapid analysis of data collected from persistent monitoring and to the adoption of supervised machine learning methods that require large volumes of curated training data. Instead, contrastive self-supervised learning on unlabeled spectra can enhance models that are built on limited labeled radiation datasets. This work demonstrates that contrastive machine learning is an effective technique for leveraging unlabeled data in detecting and characterizing nuclear material transfers demonstrated on radiation measurements collected at an Oak Ridge National Laboratory testbed, where sodium iodide detectors measure gamma radiation emitted by material transfers between the High Flux Isotope Reactor and the Radiochemical Engineering Development Center. Label-invariant data augmentations tailored for gamma radiation detection physics are used on unlabeled spectra to contrastively train an encoder, learning a complex, embedded state space with self-supervision. A linear classifier is then trained on a limited set of labeled data to distinguish transfer spectra between byproducts and tracked nuclear material using representations from the contrastively trained encoder. The optimized hyperparameter model achieves a balanced accuracy score of 80.30%. Any given model—that is, a trained encoder and classifier—shows preferential treatment for specific subclasses of transfer types. Regardless of the classifier complexity, a supervised classifier using contrastively trained representations achieves higher accuracy than using spectra when trained and tested on limited labeled data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Unraveling Electronic and Vibrational Coherences Following a Charge Transfer Process in a Photosystem II Reaction Center

A reaction center is a unique biological system that performs the initial charge separation within a Photosystem II (PSII) multiunit enzyme, which eventually drives the catalytic water-splitting in plants and algae. The possible role of quantum coherences coinciding with the energy and charge transfer processes in PSII reaction center is one of the active areas of research. Here, we study these quantum coherences by using a numerically exact method on an excitonic dimer model, including linear vibronic coupling and employing optimal parameters from experimental two-dimensional coherent spectroscopic measurements. This enables us to precisely capture the excitonic interaction between pigments and the dissipation of the energy from electronic and charge-transfer (CT) states to the protein environment. We employ the time nonlocal (TNL) quantum master equation to calculate the population dynamics, which yields numerically reliable results. The calculated results show that, due to the strong dissipation, the lifetime of electronic coherence is too short to have direct participation in the charge transfer processes. However, there are long-lived vibrational coherences present in the system at frequencies close to the excitionic energy gap. These are strongly coupled with the electronic coherences, which makes the detection of the electronic coherences with conventional techniques very challenging. Additionally, we unravel the strong excitonic interaction of radical pair (PD1 and PD2) in the reaction center, which results in a long-lived electronic coherence of >100 fs, even at room temperature. Our work provide important physical insight to the charge separation process in PSII reaction center, which may be helpful for better understanding of photophysical processes in other natural and artificial light-harvesting systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND