Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fast Surface Oxygen Release Kinetics Accelerate Nanoparticle Exsolution in Perovskite Oxides

Exsolution is a recent advancement for fabricating oxide-supported metal nanoparticle catalysts via phase precipitation out of a host oxide. A fundamental understanding and control of the exsolution kinetics are needed to engineer exsolved nanoparticles to obtain higher catalytic activity toward clean energy and fuel conversion. Since oxygen release via oxygen vacancy formation in the host oxide is behind oxide reduction and metal exsolution, we hypothesize that the kinetics of metal exsolution should depend on the kinetics of oxygen release, in addition to the kinetics of metal cation diffusion. In this report we probe the surface exsolution kinetics both experimentally and theoretically using thin-film perovskite SrTi 0.65 Fe 0.35 O 3 (STF) as a model system. We quantitatively demonstrated that in this system the surface oxygen release governs the metal nanoparticle exsolution kinetics. As a result, by increasing the oxygen release rate in STF, either by reducing the sample thickness or by increasing the surface reactivity, one can effectively accelerate the Fe 0 exsolution kinetics. Fast oxygen release kinetics in STF not only shortened the prereduction time prior to the exsolution onset, but also increased the total quantity of exsolved Fe 0 over time, which agrees well with the predictions from our analytical kinetic modeling. The consistency between the results obtained from in situ experiments and analytical modeling provides a predictive capability for tailoring exsolution, and highlights the importance of engineering host oxide surface oxygen release kinetics in designing exsolved nanocatalysts.

36 MATERIALS SCIENCE↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Quantifying particle-scale 3D granular dynamics during rapid compaction from time-resolved in situ 2D x-ray images

Understanding the particle-scale dynamics of granular materials during rapid compaction and flow is of fundamental importance for manufacturing, planetary science, geology, and defense applications. Time-resolved 2D radiography and static 3D x-ray tomography are powerful in situ tools for studying particle-scale dynamics but provide detail only in 2D or with significant time-scale limitations, respectively. Here, we introduce a new method that uses 2D in situ x-ray imaging for determining time-resolved 3D particle-scale dynamics in rapidly compressed granular materials. The method employs initial particle packing structures obtained from x-ray tomography, a 2D x-ray image generation algorithm, and an optimization algorithm. We first describe and validate the method using finite element simulations. Furthermore, we then apply the technique to x-ray phase-contrast images obtained during rapid compaction of granular materials with varying particle morphology and sample thickness. The depth-resolved particle-scale dynamics reveal complex velocity and porosity fields evolving heterogeneously along and perpendicular to the compaction direction. We characterize these features, their fluctuations near the compaction front, and the compaction front thickness. Our technique can be applied to understanding granular dynamics during rapid compaction events, and rearrangements during slower, but non-quasi-static, flows.

36 MATERIALS SCIENCE↗

Dependent scattering and fractal microstructure determine the transparency of aerogel monoliths

This study reveals how dependent scattering and microstructure significantly affect electromagnetic wave propagation through aerogel monoliths, contributing to their transparency. Light scattering by particle ensembles is considered “dependent” when the scattering properties rely not only on particle size and optical constants but also on their spatial distribution, typically occurring when the average interparticle distance is small in comparison with the wavelength of incident radiation. Addressing dependent scattering requires solving Maxwell’s equations for complex heterogeneous structures, which is computationally demanding and usually limited to sample thicknesses on the same scale as the wavelength. This study combines computer-generated ambigel microstructures of fractal aggregates of polydisperse nanoparticles and the radiative transfer with reciprocal transaction method to predict the transmittance of thick ambigel slabs. Transmittance measurements of ambiently dried aerogel monoliths (ambigels) with porosities from about 50% to 90% closely matched the predicted values for their digital twins. However, ignoring dependent scattering or particle aggregation led to inaccurate predictions. This study validated the computational framework, and its findings offer insights for designing photonic metamaterials and analyzing their interactions with electromagnetic waves.

Yalcin, Refet A. (ORCID:0000000339973494)↗

Real-space simulations of the hyperbolic plasmon polaritons in 1T′ tungsten ditelluride

Recent discoveries of hyperbolic surface plasmon polaritons (SPPs) in 1T′ WTe 2 have garnered significant attention in 2D materials and nanophotonics. In this study, we employ finite-element simulations to investigate the real-space characteristics of hyperbolic SPPs in thin WTe 2 flakes. Our results show that the SPPs exhibit a pronounced sensitivity to excitation energy and sample thickness. By analyzing the plasmonic field patterns, we extract key plasmonic parameters including plasmon wavelengths, hyperbolic angles, and plasmonic figures of merit. In addition, we examine SPP modes in stacked WTe 2 flakes with varying twist angles, demonstrating that the plasmonic field patterns can be effectively tuned by adjusting the twist angle. Notably, as the twist angle increases, the SPPs undergo a topological transition from open hyperbolic modes to closed elliptic modes. This twist-engineering capability offers promising potential for the development of tunable plasmonic devices based on WTe 2 .

2D materials↗

Ramp-release experiments for strength measurements: Strain-rate dependence

This paper presents an enhanced analysis method for investigating material properties at high strain rates, extending the capability of established experimental techniques to gain more information. The ramp-release method has been applied to many experiments reported at high (≈10 5 − 10 6 s −1 ) strain-rates. More recent data gathered at the National Ignition Facility (NIF) has enabled higher (≈10 8 s −1 ) strain-rates to be studied. Here, we present an initial application of ramp-release analysis to NIF ramp-compression data, illustrating both the opportunities and the practical challenges of extending these methods to laser-driven platforms. The higher strain-rates accessed at the NIF mean that there is more strain-rate enhancement to strength, and the experimental configuration means that this enhancement is more readily seen in the data. This is enabled by the capability of avoiding peak-compression attenuation through the sample thickness with a designed hold period made possible by the pulse-shaping capability of NIF. We propose that this combination of experimental conditions and an enhanced analysis method enables the strain-rate enhancement to strength to be studied, and potentially for this to inform physics models at smaller scales than the continuum.

36 MATERIALS SCIENCE↗

New Measurements to Resolve Discrepancies in Evaluated Model Parameters of 181 Ta

To resolve discrepancies in evaluated cross sections among major nuclear data libraries, energy-differential neutron transmission and radiative capture yield of 181 Ta were measured from 0.15 to 100 keV using multiple sample thicknesses. The new measurements provide resolution such that the resolved resonance region (RRR) can be evaluated up to at least 2.5 keV and the unresolved resonance region can be evaluated up to at least 100 keV. The transmission and capture yield measurements were modeled using resonance parameters from three major libraries to assess the predictive capability of each. It was found that JENDL-5.0 performed best in the RRR. Because of the poor performance of the U.S. ENDF/B evaluation, it is recommended that ENDF/B be reevaluated for 181 Ta.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Topological surface conduction in Kondo insulator YbB 12

Kondo insulators have recently aroused great interest because they are promising materials that host a topological insulator state caused by the strong electron interactions. Moreover, recent observations of the quantum oscillations in the insulating state of Kondo insulators have come as a great surprise. Here, we investigate the surface electronic state of a prototype Kondo insulator YbB 12 , we measured the transport properties of single crystals and microstructures. In all samples, the temperature dependence of the electrical resistivity is insulating at high temperatures and the resistivity exhibits a plateau at low temperatures. The magnitude of the plateau value decreases with reducing sample thickness, which is quantitatively consistent with the surface electronic conduction in the bulk insulating YbB 12 . Moreover, the magnetoresistance of the microstructures exhibits a weak-antilocalization effect at low field. These results are consistent with the presence of a topologically protected surface state, suggesting that YbB 12 is a candidate material for a topological Kondo insulator. The high field resistivity measurements up to µ 0 H = 50 T of the microstructures provide supporting evidence that the quantum oscillations of the resistivity in YbB 12 occurs in the insulating bulk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization-controlled volatile ferroelectric and capacitive switching in Sn 2 P 2 S 6

Abstract Smart electronic circuits that support neuromorphic computing on the hardware level necessitate materials with memristive, memcapacitive, and neuromorphic- like functional properties; in short, the electronic response must depend on the voltage history, thus enabling learning algorithms. Here we demonstrate volatile ferroelectric switching of Sn 2 P 2 S 6 at room temperature and see that initial polarization orientation strongly determines the properties of polarization switching. In particular, polarization switching hysteresis is strongly imprinted by the original polarization state, shifting the regions of non-linearity toward zero-bias. As a corollary, polarization switching also enables effective capacitive switching, approaching the sought-after regime of memcapacitance. Landau–Ginzburg–Devonshire simulations demonstrate that one mechanism by which polarization can control the shape of the hysteresis loop is the existence of charged domain walls (DWs) decorating the periphery of the repolarization nucleus. These walls oppose the growth of the switched domain and favor back-switching, thus creating a scenario of controlled volatile ferroelectric switching. Although the measurements were carried out with single crystals, prospectively volatile polarization switching can be tuned by tailoring sample thickness, DW mobility and electric fields, paving way to non-linear dielectric properties for smart electronic circuits.

97 MATHEMATICS AND COMPUTING↗

Resonant propagation of extreme-ultraviolet pulses through strongly driven high-density media

We show that by combining strong-field dressing and resonant propagation of XUV pulses, the transition of absorption lines from their natural Lorentzian profiles through Fano and complex multipeak shapes all the way back to broadened near-Lorentzian profiles can be achieved, in the limit of optically thick samples. The final stage of this spectral modification can be understood in terms of a significant temporal stretching and delay of the resonant XUV pulse as it propagates through the dense gas, which alters the ultrafast absorption that is modified by the time-synchronized few-femtosecond laser pulse. We first demonstrate this concept in numerical calculations, both using a model system and through a fully coupled solution of the time-dependent Schrödinger equation and the Maxwell wave equation. The applicability and generality of the underlying mechanism is then illustrated in proof-of-principle attosecond transient absorption measurements in a helium gas with a widely varying atomic density. These results provide insights into the interaction of ultrashort laser pulses with dense media and its coherent control. Published by the American Physical Society 2025

He, Yu (ORCID:0000000152120176)↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical anisotropy of CsPbBr3 perovskite nanoplatelets

Abstract The two-dimensional CsPbBr 3 nanoplatelets have a quantum well electronic structure with a band gap tunable with sample thicknesses in discreet steps based upon the number of monolayers. The polarized optical properties of CsPbBr 3 nanoplatelets are studied using fluorescence anisotropy and polarized transient absorption spectroscopies. Polarized spectroscopy shows that they have absorption and emission transitions which are strongly plane-polarized. In particular, photoluminescence excitation and transient absorption measurements reveal a band-edge polarization approaching 0.1, the limit of isotropic two-dimensional ensembles. The degree of anisotropy is found to depend on the thickness of the nanoplatelets: multiple measurements show a progressive decrease in optical anisotropy from 2 to 5 monolayer thick nanoplatelets. In turn, larger cuboidal CsPbBr 3 nanocrystals, are found to have consistently positive anisotropy which may be attributed to symmetry breaking from ideal perovskite cubes. Optical measurements of anisotropy are described with respect to the theoretical framework developed to describe exciton fine structure in these materials. The observed planar absorption and emission are close to predicted values at thinner nanoplatelet sizes and follow the predicted trend in anisotropy with thickness, but with larger anisotropy than theoretical predictions. Dominant planar emission, albeit confined to the thinnest nanoplatelets, is a valuable attribute for enhanced efficiency of light-emitting devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic Field Penetration Technique to Study High Field Shielding of Multilayered Superconductors

The SIS structure which consists of alternative thin layers of superconductors and insulators on a bulk niobium has been proposed to shield niobium cavity surface from high magnetic field and hence increase the accelerating gradient. The study of the behavior of multilayer super-conductors in an external magnetic field is essential to optimize their SRF performance. In this work we report the development of a simple and efficient technique to measure penetration of magnetic field into bulk, thin film and multilayer superconductors. Experimental setup contains a small superconducting solenoid which can produce a parallel surface magnetic field up to 0.5 T and Hall probes to detect penetrated magnetic field across the superconducting sample. This system was calibrated and used to study the effect of niobium sample thickness on the field of full magnetic flux penetration. We determined the optimum thickness of the niobium substrate to fabricate the multilayer structure for the measurements in our setup. This technique was used to measure penetration fields of Nb₃Sn thin films and Nb₃Sn/Al₂O₃ multi-layers deposited on Al₂O₃ wafers.

Senevirathne, I. H.↗

Requirements for an in-house synchrotron radiation source at LANL

Synchrotron measurements for diffraction characterization and high resolution tomography require: (1) unable monochromatic X-ray incident energy from 65keV to 100keV. 65keV need is defined by Ta and W absorption edges at 67keV, 100keV need is defined by need to penetrate U/Pu sample thickness of 0.5 mm (2) focused flux density of the monochromatic beam on a beam spot of ~100 µm 2 greater than 10 10 photons per second to allow some slower kinetics experiments such as heating, cooling for CTE measurements (but not quenching, solidification etc. which require <0.1 s resolution) (3) Δλ/λ resolution of 0.3% or better across the energy spectrum. This can be achieved by monochromator as long as flux needs are met in the monochromatic beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

Investigating Hydrogen Isotope Exchange Reactions on Lithium Aluminate Pellets in TPBAR (FY22 Report)

We developed a novel operando Raman spectroscopy method for investigation of hydrogen (H) isotope exchange reactions in the lithium aluminate (γ-LiAlO 2 ) that allows modeling of tritium behaviors in high temperature and in an irradiated environment. The lithium aluminate pellet is a main component in the Tritium-Producing Burnable Absorber Rod (TPBAR). We used deuterium ( 2 H or D) as a surrogate to simulate tritium ( 3 H or T). We used a surface analysis tools in situ/operando Raman spectroscopy to observe the transformation OH and OD compositional changes. We also used ToF-SIMS to analyze the lithium aluminate pellet control sample to build the base line for future in situ/operando analysis. To conduct operando Raman spectroscopy, we developed a custom reaction cell with a detachable micro heater using microelectromechanical systems (MEMS) and 3D printing techniques. Multiple versions were developed and tested. Using the new reaction cell, we demonstrated operando Raman spectroscopy of water (H 2 O) and deuterated water (D 2 O) with nitrogen (N 2 ) exposure onto the lithium aluminate (LiAlO2) pellet specimen, respectively, using a wet gas injection setup. We also successfully developed a detachable microheater that can heat up to ~250°C for ~90 mins. The Raman spectra did not show clear H 2 O and D 2 O characteristic peaks, which indicates that introducing H 2 O and D 2 O onto the surface of the pellet is challenging due to its dense structure nature. Our efforts suggest that various improvements are needed, such as increasing reaction cell operating gas pressure and thinning pellet sample thickness, to obtain meaningful measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of a Custom Ball-on-Ring Apparatus and Consideration of Common Issues for Use in Further Testing (SULI Deliverables)

Ceramic materials are well-known for their high hardness and strength but are limited in their application due to low toughness and sudden failure. As a potential solution, inspiration can be taken from dental enamel nanostructure, where undulating rods cause cracks to branch or deflect, increasing the energy needed to cause total fracture of a ceramic part. Following the dental enamel structure, a novel ceramic which uses 3D printed Yttria stabilized Zirconia rods in an alumina matrix was developed. To test this bio-inspired ceramic material, a proper testing apparatus needed to be created and tested to verify its accuracy. For this project, a bespoke ball on ring testing apparatus was created and tested using both conventionally sintered alumina disks and purchased alumina disks to validate its accuracy. By comparing the Weibull distribution of rupture strengths measured by the tests to literature values, it was shown that the testing frame had a wide distribution of strength which did not align with literature values on the lower end. Through fractography, it was found that some samples fractured from the contact stress induced by the ball indenter, which could not be used to calculate rupture strength. This fracture was often linked to low stress to failure, which was initiated by a flaw on the surface near the indenter which acted as a stress concentrator. Removal of these samples from the data set increased the accuracy of the reported rupture strength values for the ceramic. Considering the equations for the magnitude of contact and flexural strength, along with observations of initiating flaws, several measures can be taken for testing the bio-inspired composite. These measures include proper polishing of both sides of the sample, reducing sample thickness, and potentially using a softer indenter material.

36 - MATERIALS SCIENCE↗

Measured current drainage through holes in various dielectrics up to 2 kilovolts in a dilute plasma

The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.

Grier, N. T.↗