Comparison of measured and calculated dynamic loads for the Mod-2 2.5 mW wind turbine system

The Boeing Company, under contract to the Electric Power Research Institute (EPRI), has completed a test program on the Mod-2 wind turbines at Goodnoe Hills, Washington. The objectives were to update fatigue load spectra, discern site and machine differences, measure vortex generator effects, and to evaluate rotational sampling techniques. This paper shows the test setup and loads instrumentation, loads data comparisons and test/analysis correlations. Test data are correlated with DYLOSAT predictions using both the NASA interim turbulence model and rotationally sampled winds as inputs. The latter is demonstrated to have the potential to improve the test/analysis correlations. The paper concludes with an assessment of the importance of vortex generators, site dependence, and machine differences on fatigue loads. The adequacy of prediction techniques used are evaluated and recommendations are made for improvements to the methodology.

Zimmerman, D. K.↗

Modal Test and Model Correlation of NASA Plum Brook Station Mechanical Vibration Facility Head Expander –Lessons Learned from the Perspective of an Early-Career Engineer

In preparation for the Sierra Nevada Corporation’s (SNC) Dream Chaser spacecraft vibration test campaign at the Mechanical Vibration Facility (MVF) at NASA Plum Brook Station (PBS) in Sandusky, Ohio, a test-verified model of MVF is needed in order to be able to perform accurate pretest analysis used for determining response limits and abort levels. MVF was designed to vibration test MPCV Orion and was used to perform the system level vibration test of the European Service Module Structural Test Article (E-STA) in 2016. MVF is comprised of an 18 ft diameter annulus table that is driven with sixteen hydraulic vertical actuator assemblies and four hydraulic horizontal actuator assemblies, which allow it to perform single axis vibration testing in the vertical axis and in each of the two orthogonal horizontal axes without the need for reconfiguring the test article. A head expander for the MVF Table has been designed and built that fills in the center opening providing a continuous flat mounting surface with a maximum diameter of 16.25feet that expands the vibration testing capabilities of MVF. The MVF Table with this head expander will be used during the SNC Dream Chaser spacecraft vibration test campaign. Therefore, a critical element in a test-verified model of the MVF will be a test correlated finite element model (FEM) of the head expander. To obtain this, engineers from the Structural Dynamics Lab (SDL) at NASA Glenn Research Center (GRC) in Cleveland, Ohio performed a modal pretest analysis, conducted a modal test in July 2019, and most recently correlated the head expander finite element model to the modal test data up to 300 Hz. From the initial test preparations to the final delivery of a correlated finite element model, all efforts mentioned were led by the same early-career engineers at NASA GRC. From the viewpoint of an early-career engineer, lessons learned about modal pretest analysis, modal testing, and finite element model correlation of the MVF Table expander head will be presented and discussed. This will include the importance of understanding the limitations of using uncorrelated finite element models in the modal pretest analysis and planning, the importance of orthogonality metrics in judging adequacy and accuracy of test mode shapes, and the importance of having the FEM match the as built hardware in the model correlation effort.

Emma L Pierson↗

Mars 2020 Mobility Actuator Thermal Testing and Model Correlation

This paper describes the thermal testing and model correlation of a mobility actuator planned for use on the Mars 2020 Rover. The mobility actuator is identical to those which have been successfully flown and operated on the Mars Science Laboratory (MSL) Curiosity rover since its successful landing on Mars in August of 2012. The actuator consists of a motor, brake, and encoder paired with a four stage planetary gear box. In this thermal test, the actuator was instrumented with a number of thermocouples on both the interior and exterior of the gearbox. Heaters and a cold plate were used to generate thermal gradients across the actuator in vacuum, low pressure GN2, and low pressure CO2 environments in an effort to correlate a thermal model and develop a better understanding of how heat flows through the mechanism. This testing resulted in the successful model correlation of a simplified thermal model, and yielded important insights regarding the conductance of ball bearings and gear-to-gear contact. Ball bearing thermal conductance in a low pressure environment can be estimated by using correlations for vacuum thermal conductance along with a multiplier to account for increased gas conduction, and gear-to-gear conductance can be estimated by accounting for gas and grease conduction between two gears.

Novak, Keith↗

Design, Development, and Test of the Advanced Apollo Orbital Assembly System

As spaceflight moves toward commercial solutions for Crew Vehicles and Space Stations, opportunity exists to lower costs with novel designs. Probe and cone docking systems provide a lightweight, low cost, and high-performance docking solution. This work revisits the Apollo probe and cone design and modifies it for the requirements of today’s computer-controlled spacecraft. This new system is called the Advanced Apollo Orbital Assembly (APOA) system, and is intended to support satellite, cargo, and space station assembly missions. A simulation of the APOA was programmed, components were sized, and a design was created by scaling the probe to the size of an EELV Secondary Payload Adapter (ESPA) tunnel. Prototype test hardware was 3D printed using Fused Deposition Modeling (FDM) methods with Polylactic Acid (PLA) material. Testing of the APOA-ESPA was conducted at Marshall Space Flight Center’s (MSFC) Flat Floor, and a test-correlated simulation is used to evaluate a Monte-Carlo of Initial Contact Conditions (ICC’s) to establish baseline performance. The successful development, test, and correlation of the APOA-ESPA proves the design validity and increases Technology Readiness Level (TRL) from 2 to 4. This work opens the door to construction of an APOA-ESPA from flight like materials, and to develop a larger scale prototype APOA. When the full scale APOA is incorporated with the Common Berthing Mechanism (CBM), becomes the Hybrid Berthing System (HBS), which allows for berthing without a robotic arm.

Berthing↗

Controlled Pyroshock Test Transients Can Be Used To Better Match Operational Shock Transients and Reduce Artificial Pyroshock Test Failures [Slides]

Shock analysis is typically done via SRS (shock response spectrum). Oftentimes shock analysis is not performed because most loads specifications only supply SRS requirements with no representative shock transients that can be used for analysis. SRS analysis is too conservative. There is no structural dynamics involved as all modes are assumed to have peak responses simultaneously and in-phase with each other. It is possible that all other loads and combination of loads show the design to be good, whereas SRS analysis (1000 g’s are involved) results may require redesign. Multiple shock transients can satisfy a SRS, yet most loads documents don’t provide a representative shock transient that could be used for shock analysis. Shock testing is less common than harmonic and random vibration testing. Engineers typically go into shock tests with very little knowledge of what to expect. A pass/fail type of approach with very little engineering done to prepare for the test or to control the type of shock transient is used. Most engineers will not model the shock test fixture due to lack of knowledge about the details of the test setup. Shock analysis and testing is often an open loop type situation with no test setup modeling, no test correlation, and no control over the test shock transient. In this work, if we can create applied test force transient that comes close to matching calculated force transient then a more reasonable acceleration transient will be created at the test reference accelerometer that better matches operational shocks.

42 ENGINEERING↗

Progress in high temperature speckle-shift strain measurement system

A fast, easy to use speckle tracking system is under development for the speckle-shift strain measurement technique. Preliminary correlation tests on wire specimens show strong correlations of well-developed speckle patterns. Stable cross-correlations were obtained from a tungsten filament at 2480 C. An analysis of the optical system determines the minimum required sampling frequency of the speckle pattern to be 2.55 pixels per speckle.

Lant, Christian T.↗

Lessons Learned from the Wide Field Camera 3 Flight Correlation

The Wide Field Camera 3 (WFC3) instrument was installed into the Hubble Space Telescope (HST) as part of the activities for STS (Space Transportation System)-125 (HST Servicing Mission 4). Initial model predictions for power and radiator temperature were not in good agreement with flight data during a relatively hot, stable period, with the flight power and temperatures being significantly higher than predictions. Significant efforts were undertaken to identify the causes of the discrepancies and to resolve the flight model correlation problems as the thermal vacuum test correlation indicated good agreement. The WFC3 thermal design performance has proven difficult to accurately predict, since the power dissipation on the radiator typically increases as the radiator temperature increases, due to a Thermo Electric Cooler (TEC) attached to the this radiator. This self beating continues until the radiative emissive capability is met for a given temperature, and only then does the system find a quasi-steady regime. Various other factors may also contribute to the radiator temperature, such as backloadlng from the observatory itself and the planet, local high-absorptivity regions near fasteners/holes, and temperature varying parasitic heat leaks from the instrument itself to the radiator. Each of these effects in turn may increase the radiator temperature, and furthermore the demand on the TEC.

Peabody, Hume L.↗

Correlations of trace elements in breast human tissues: Evaluation of spatial distribution using {mu}-XRF

The aim of this work is to investigate microscopic correlations between trace elements in breast human tissues. A synchrotron X-ray fluorescence microprobe system ({mu}-XRF) was used to obtain two-dimensional distribution of trace element Ca, Fe, Cu and Zn in normal (6 samples) and malignant (14 samples) breast tissues. The experiment was performed in X-ray Fluorescence beam line at Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, Brazil. The white microbeam was generated with a fine conical capillary with a 20 {mu}m output diameter. The samples were supported on a XYZ table. An optical microscope with motorized zoom was used for sample positioning and choice the area to be scanned. Automatic two-dimensional scans were programmed and performed with steps of 30 {mu}m in each direction (x, y) on the selected area. The fluorescence signals were recorded using a Si(Li) detector, positioned at 90 degrees with respect to the incident beam, with a collection time of 10 s per point. The elemental maps obtained from each sample were overlap to observe correlation between trace elements. Qualitative results showed that the pairs of elements Ca-Zn and Fe-Cu could to be correlated in malignant breast tissues. Quantitative results, achieved by Spearman correlation tests, indicate that there is a spatial correlation between these pairs of elements (p < 0.001) suggesting the importance of these elements in metabolic processes associated with the development of the tumor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface flow visualization requirements for testing in NTF

Surface flow visualization is required to be correlated at all the facilities to allow the following: (1) an understanding of the chordwise and spanwise extent of laminar flow; (2) the change in shock location for various trip configurations; (3) the effectiveness of the chosen boundary layer trip (since its specifications will change as a function of Reynolds number); and (4) a comparison of the separation patterns at the buffet conditions. A requirement to tunnel-to-tunnel correlation testing involving the NTF is pointed out. A specification for a surface flow visualization system to be used in the NTF is defined. Recognition of the special limitations in the NTF including physical and visual accessibility, high operating cost, flow contamination requirements, as well as the need for on-line review of the results to develop the final trip configurations in a timely manner, leads to the listed requirements.

Bengelink, R. L.↗

Controlled Contamination of Epoxy Composites with PDMS and Removal by Laser Ablation

Surface preparation is critical to the performance of adhesively bonded composites. During manufacturing, minute quantities of mold release compounds are inevitably deposited on faying surfaces and may compromise bond performance. To ensure safety, mechanical fasteners and other crack arrest features must be installed in the bondlines of primary structures, which negates some advantages of adhesively bonded construction. Laser ablation is an automated, repeatable, and scalable process with high potential for the surface preparation of metals and composites in critical applications such as primary airframe structures. In this study, laser ablation is evaluated on composite surfaces for the removal of polydimethylsiloxane (PDMS), a common mold release material. Composite panels were contaminated uniformly with PDMS film thicknesses as low as 6.0 nm as measured by variable angle spectroscopic ellipsometry. Bond performance was assessed by mechanical testing using a 250 F cure, epoxy adhesive and compared with pre-bond surface inspection results. Water contact angle, optically stimulated electron emission, and laser induced breakdown spectroscopy were used to characterize contaminated and laser ablated surfaces. The failure mode obtained from double cantilever beam tests correlated well with surface characterization data. The test results indicated that even low levels of PDMS were not completely removed by laser ablation.

Palmieri, Frank↗

European Service Module - Structural Test Article (E-STA) Building Block Test Approach and Model Correlation Observations

The Orion European Service Module - Structural Test Article (E-STA) underwent sine vibration testing in 2016 using the Mechanical Vibration Facility (MVF) multi-axis shaker system at NASA Glenn Research Center’s (GRC) Plum Brook Station (PBS) Space Power Facility (SPF). The main objective was to verify the structural integrity of the European Service Module (ESM) under sine sweep dynamic qualification vibration testing. A secondary objective was to perform a fixed-base modal survey, while E-STA was still mounted to MVF, in order to achieve a test correlate the finite element model (FEM). To facilitate the E-STA system level correlation effort, a building block test approach was implemented. Modal tests were performed on two major subassemblies, the crew module/launch abort structure (CM/LAS) and the crew module adapter (CMA) mass simulators. These subassembly FEMs were individually correlated and then integrated into the E-STA FEM prior to the start of the E-STA sine vibration test. This paper summarizes the modal testing and model correlation efforts of both of these subassemblies and how the building block approach assisted in the overall correlation of the E-STA FEM. This paper will also cover modeling practices that should be avoided, recommended instrumentation positioning on complex structures, and the importance of the FEM geometrically matching CAD in sufficient detail in order to adequately replicate internal load paths. The goal of this paper is to inform the reader of the hard earned lessons learned and pitfalls to avoid when applying a building block test approach.

Winkel, James P.↗

Report of the wind tunnel/flight correlation panel

Basic calibration of the tunnel prior to conducting any tests, the areas requiring wind tunnel/flight test correlation for validating the NTF, and recommendations for achieving validation of the NTF are discussed.

Ayers, T. G.↗

Exploring Sustainability in Scientific Software through Code Quality & Test Coverage Metrics

Context: Scientific open-source software (SciOSS) plays a foundational role in research and engineering, yet its long-term sustainability has often been overlooked and remains a significant concern. Objective: This study investigates the long-term sustainability of SciOSS through code and test quality metrics. Method: We analyze CASS Software Portfolio projects, classifying them by sustainability and comparing their code structure, test coverage, and links between code quality and testing across the dataset. Results: Sustainable projects show higher, more consistent test coverage and clearer code-test correlations, while unsustainable ones show weaker patterns. Overall, test coverage is low in scientific software, and high complexity and coupling reduce testability. Conclusion: In this study, we present a practical, data-driven approach for assessing sustainability in scientific software, offering a foundation for evaluating long-term software health and supporting future efforts in quality assurance and sustainability monitoring.

Md mushfiqur rahman, Sheikh [University of Tenness↗

Turbopumps for cryogenic upper stage engines

Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.

Zachary, A. T.↗

Final Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst↗

Specific Hardening Function Definition and Characterization of a Multimechanism Generalized Potential-based Viscoelastoplasticity Model

Given the previous complete-potential structure framework together with the notion of strain- and stress-partitioning in terms of separate contributions of several submechanisms (viscoelastic and viscoplastic) to the thermodynamic functions (stored energy and dissipation) a detailed viscoelastoplastic multimechanism characterization of a specific hardening functional form of the model is presented and discussed. TIMETAL 21S is the material of choice as a comprehensive test matrix, including creep, relaxation, constant strain-rate tension tests, etc. are available at various temperatures. Discussion of these correlations tests, together with comparisons to several other experimental results, are given to assess the performance and predictive capabilities of the present model particularly with regard to the notion of hardening saturation as well as the interaction of multiplicity of dissipative (reversible/irreversible) mechanisms.

Arnold, S. M.↗