Infrared spectroscopic analysis of the effects of simulated space radiation on a polyimide

Infrared spectroscopic techniques have been used to study the effects of electron radiation on the polyimide PMDA-p,p-prime- ODA. The radiation exposures were made at various dose rates, for a total dose approximately equal to that for 30 years of exposure to electron radiation in geosynchronous earth orbit. At high dose rates the major effect was probably the formation of a polyisoimide or a charged quaternary amine, and at the low dose rates the effect was a reduction in the amount or aromatic ether linkage. In addition, the effects of dose rate for a small total dose were studied. Elevated temperatures occurred at high dose rates and were, in part, probably the cause of the radiation product. The data suggest that dose rates for accelerated simulations of the space environment should not exceed 100,000 rads/sec.

Ferl, J. E.↗

Goddard Modular SmallSat Architecture (GMSA) Adapter Board H-Bridge MOSEFT ICs Total Ionizing Dose Characterization Report

The purpose of this testing was to obtain total ionizing dose (TID) information about commercial off-the-shelf (COTS) n-channel and p-channel MOFETs that are being considered for use on the Goddard Modular SmallSat Architecture (GMSA) Adapter board in an H-Bridge circuit to drive magnetorquers. Testing took place at NASA Goddard Space Flight Center’s (GSFC) Radiation Effects Facility using the gamma source. Testing occurred from July 31st – August 1st, 2018.

total ionizing dose (TID)↗

The Effect of Total Ionizing Dose Degradation of Laptop Hard Disks

A series of total ionizing dose (TID) measurements were performed on commercial hard drives to explore the possible uses of the devices for the high radiation mission, and to help the understanding of the reliability of current hard drive technology. Three different models from three major manufacturers were tested with the aid of a commercial hard drive test system.

laptop computers↗

Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

Proton Damage↗

Total Ionizing Dose Effects in Bipolar and BiCMOS Devices

This paper describes total ionizing dose (TID) test results performed at JPL. Bipolar and BiCMOS device samples were tested exhibiting significant degradation and failures at different irradiation levels. Linear technology which is susceptible to low-dose dependency (ELDRS) exhibited greater damage for devices tested under zero bias condition.

radiation effects↗

Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

enhanced low dose rate sensitivity (ELDRS↗

Total Ionizing Dose (TID) Testing of the PA10 Power Operational Amplifier

This study was undertaken to determine the total ionizing dose (TID) sensitivity of the PA10 Power Op Amp Manufactured by APEX (figure 1), which is a candidate for use on the LDCM TIRS instrument. The test was conducted with interest in both parametric degradation and functional failure in the configuration like that of the TIRS application. (See figure 2). The DUT was irradiated in a stepwise fashion, with parametric and functional degradation measured between steps. The parts were irradiated with gamma rays at a low dose rate (~0.01 rads(Si)/sec.).

total ionizing dose (TID)↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

ELDRS Characterization for a Very High Dose Mission

Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

Radiation Damage↗

A 0.18 micrometer CMOS Thermopile Readout ASIC Immune to 50 MRAD Total Ionizing Dose (SI) and Single Event Latchup to 174MeV-cm(exp 2)/mg

Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.

radiation hardened by design↗