Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of the VOLT-A Shuttle experiment

The NASA Lewis Research Center (LeRC) is investigating potential problems associated with the operation of high voltage solar cell arrays in the space plasma environment. At high voltages, interactions between the solar array and the space plasma could result in unacceptable levels of electrical discharge (arcing) and/or parasitic losses (current drains from the array to the plasma). The objective of the Voltage Operating Limit Tests (VOLT-A) Shuttle bay experiment is to characterize space plasma/solar cell panel interactions in low earth orbit. VOLT-A consists of an experiment plate subassembly which contains four solar panels, an electronics subassembly and a Langmuir probe subassembly mounted on an MPESS carrier. During a given 8.25 hour data taking period (5-1/2 continuous orbits), the solar panels, which represent state-of-the-art solar cell technologies, will be sequentially subjected to bias voltages in steps ranging from minus 626 V to plus 313 V. Appropriate measurements will be made at each voltage to characterize arcing and parasitic losses. Corresponding measurements of the plasma environment (plasma density, electron temperature and neutral density) will also be made. Data will be recorded on an on-board tape recorder for subsequent data reduction and analysis.

Bifano, William J.↗

To grind or not to grind? The influence of mechanical and thermal treatments on the $\mathrm{Cu/Zn}$ disorder in $\mathrm{Cu}$ 2 $\mathrm{ZnSn}$($\mathrm{S}$ x $\mathrm{Se}$ 1-x ) 4 monograins

We report that Kesterite-type based thin film solar cell technologies are mainly based on polycrystalline absorber layers. A promising low cost alternative technology uses Cu 2 ZnSn(S x Se 1-x ) 4 (CZTSSe) monograins (single crystals of 20–100 μm size) which are fixed in a polymer matrix to form a flexible solar cell. The Cu/Zn disorder is discussed as a possible reason for band tailing causing voltage losses limiting the efficiency of CZTSSe-based devices. The experimental determination of the order parameter Q which is a quantitative measure of Cu/Zn disorder, requires a differentiation between the isoelectronic cations Cu + and Zn 2+ . An in-depth analysis of neutron diffraction data allows the determination of type and concentration of intrinsic point defects including a distinction between Cu and Zn. Neutron diffraction requires large sample volumes, thus monograins offer the unique possibility to correlate structural disorder in CZTSSe with device performance parameters. In this study we tackle the influence of grinding the monograins on stoichiometry deviations, the Cu/Zn disorder as well as intrinsic point defects and optoelectronic properties of CZTSSe monograins. Moreover, an easy methodology based on Raman scattering spectroscopy is proposed for the assessment of Cu/Zn disorder in the CZTSSe compounds.

14 SOLAR ENERGY↗

Probing Operando Electrochemical Strain Generation in α-NaFeO 2 Composite Cathodes during Cycling of Na-Ion Batteries

The transition metal oxide (TMO) cathodes in Na-ion batteries suffer from low-capacity retention. Chemo-mechanical instabilities lead to the deterioration of the electrochemical performance of TMO cathodes in Li-ion batteries. However, there is not much known about the chemo-mechanical instabilities in the TMO cathodes for Na-ion batteries. Understanding the governing forces behind the interplay between the electrochemical performance and mechanical stability in TMO cathodes is critical for the development of Na-ion batteries. Here, we synchronize the digital image correlation (DIC) technique with electrochemical analysis to capture the real-time deformation behavior of the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage is 3.6 V, the cathode experiences reversible deformations (except for the first cycle). There is negative strain (shrinkage) generation during Na extraction and positive strain (expansion) generation during the subsequent Na insertion. A detailed analysis of the potential-dependent strain rate evolution points out complicated phase transformations and nonequilibrium conditions in the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage was increased to 4.2 V, there was a rapid capacity loss and large plastic deformations in the α-NaFeO 2 cathodes. We provide an in-depth discussion about the possible mechanisms behind the chemo-mechanical instabilities in the α-NaFeO 2 . In conclusion, the correlation is critical to develop material-based strategies to mitigate instability mechanisms in TMO cathodes for Na-ion batteries.

Wable, Minal [University of Maryland Baltimore Cou↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

Electrical power requirements analysis. Single failure tolerant entry

The results of an analysis of the orbiter electrical power system for the case of a single failure tolerant (SFT) entry are presented. The analysis was performed using the shuttle electrical power system analysis computer program. It was performed to permit assessment of the capability of the orbiter systems to support the proposed entry configuration and to provide the data necessary to identify potential constraints and limitations. Three contingency modes have been identified which would require an SFT entry. This analysis addresses an SFT entry resulting from the loss of two fuel cell powerplants, while on orbit. The results of the analysis indicate that, even under near optimum conditions, the fuel cell power demand will exceed the tested operating capacity of 16 kw, and that various electrical components may experience voltages below 24 VDC.

Pipher, M. D.↗

Effects of plasma sheath on solar power satellite array

The structure of the plasma sheath and equilibrium voltage distribution of a high-power solar array governs various kinds of plasma-interaction phenomena and array losses. Sheath effects of a linearly-connected array are investigated for GEO. Although the array may be large, the thin-sheath-limit analysis may be invalid, necessitating numerical methods. Three-dimensional computer calculations show that potential barriers and over-lapping sheaths can occur, i.e., structures not predictable under the thin-sheath-limit analysis, but nevertheless controlling the distribution of plasma currents impacting on the array.

Parker, L. W.↗

A general numerical analysis program for the superconducting quasiparticle mixer

A user-oriented computer program SISCAP (SIS Computer Analysis Program) for analyzing SIS mixers is described. The program allows arbitrary impedance terminations to be specified at all LO harmonics and sideband frequencies. It is therefore able to treat a much more general class of SIS mixers than the widely used three-frequency analysis, for which the harmonics are assumed to be short-circuited. An additional program, GETCHI, provides the necessary input data to program SISCAP. The SISCAP program performs a nonlinear analysis to determine the SIS junction voltage waveform produced by the local oscillator. The quantum theory of mixing is used in its most general form, treating the large signal properties of the mixer in the time domain. A small signal linear analysis is then used to find the conversion loss and port impedances. The noise analysis includes thermal noise from the termination resistances and shot noise from the periodic LO current. Quantum noise is not considered. Many aspects of the program have been adequately verified and found accurate.

Hicks, R. G.↗

Reversible solid oxide cells: Early performance and microstructural evolution during electrolysis and switched mode operation

Incorporating more renewables into our energy mix will require a diversity of technological solutions. Reversible solid oxide cell systems (RSOCs) operating reversibly between fuel cell and electrolysis modes with high round-trip efficiencies offer one such solution. However, questions remain about the stability of the oxygen and fuel electrodes under reversible operation. Here, in this study, single cells with the configuration Ni-YSZ|YSZ|GDC10|NNO-NDC50|NNO are operated by reversible cycling under potentiostatic conditions. Test conditions are chosen to be representative of average stack conditions that are likely to be encountered during operation of a stack constructed of such cells. The results of reversible cycling over 500 h (21 cycles) are compared with operating the cells under potentiostatic conditions in the electrolysis-only mode (i.e., without cycling). Voltage-current density (DC), AC complex impedance spectroscopy, distribution of relaxation times (DRT) analysis, and scanning electron microscopy (SEM) indicate excellent reversibility and stability of the neodymium nickelate-based oxygen electrodes in both electrolysis and reversible cycling modes. Degradation behavior is attributed to the loss and coarsening of connected Ni particles in the fuel electrode, particularly in the active layer. However, reversible operation mitigates this degradation compared to operation in the electrolysis-only (SOEC-only) mode.

25 ENERGY STORAGE↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust PCA-Deep Belief Network Surrogate Model for Distribution System Topology Identification with DERs

With the expansion of distribution networks and increased penetration of distributed energy resources (DERs), it is becoming increasingly important to obtain accurate distribution network topology in real-time. In this paper, a robust principal component analysis coupled deep belief network (PCA-DBN) surrogate model is proposed for distribution system topology identification. It integrates the benefits of robust feature extraction from PCA to deal with data quality issues and filter out noise, and the strength of DBN in capturing the nonlinear relationship between voltage amplitudes and the binary states of switchable connections. This also significantly reduces the DBN training complexity without loss of accuracy. It is shown that the widely used standard deviation of voltage drop and the voltage covariance matrix features yield less accuracy as compared to that of the voltage amplitudes in presence of high penetration of DERs and ZIP loads. Comparison results with other alternatives, such as the random forest (RF), multi-output regression (MOR) and the traditional DBN methods demonstrate that the proposed method can achieve a much higher topology identification accuracy while maintaining robustness to missing data and measurement noise under various penetration levels of DERs.

deep belief network↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

Utilization of Machine Learning Techniques for Managing the Tracking and Data Relay Satellite Constellation

National Aeronautics and Space Administration’s (NASA) Goddard Space Flight Center (GSFC) operates a constellation of ten geosynchronous Tracking and Data Relay Satellites (TDRS). The TDRS constellation consists of multiple geosynchronous communication relay satellites located around the equator so they can provide continual coverage of any mission in low earth orbit. The TDRS are located primarily in three oceanic regions around the earth. NASA’s White Sands Complex provides the ground communication support for TDRS located over the Atlantic and Pacific Oceans. Another TDRS ground station in Guam supports the TDRS over the Indian Ocean. With these satellites the TDRS network can provide continuous coverage of satellites in low-earth orbit. The NASA Space Network (SN) project office at GSFC manages the constellation of spacecraft. Major customers of the TDRS constellation include, but are not limited to, the International Space Station and the Hubble Space Telescope. The TDRS constellation has three generations of satellites and has been active for over 30 years providing reliable communication links between customer satellites and corresponding ground stations. However, one of the major concerns for TDRS, and in any space mission, is to ensure the health and safety of the spacecraft. Generally, engineers use telemetry data to monitor and analyze the performance and state of health of the spacecraft. Telemetry data contains hundreds of parameters that monitor each important component in the spacecraft, which can be utilized to recognize and characterize the behavior of the spacecraft. Each parameter contains considerable information to represent time-dependent properties of each spacecraft subsystem and component. During the entire life of a TDRS spacecraft, thousands of gigabytes of telemetry data are transmitted in real-time from the spacecraft to the ground station at the White Sands Complex in Las Cruces, New Mexico, and recorded as historical data sets for engineers to process and analyze the events that occurred on-orbit. These parameters contain the function of multiple spacecraft subsystems, such as the attitude control system (ACS), Thermal, Electrical Power Subsystem (EPS), etc. . The first and second generations have exceeded their required lifetime and NASA is keen to manage these spacecrafts carefully in order to maximize the remaining life using the spacecraft telemetry. The challenge is to know when the risk of losing a spacecraft in geosynchronous orbit exceeds the benefit of continued operations for customer support. In the TDRS fleet, the EPS is the most critical subsystem related to spacecraft operations. Failure of the EPS would strand a spacecraft in geosynchronous orbit. Since EPS provides power to the spacecraft, component failures ultimately lead to the inability to support the spacecraft loads and the communications payload. For instance, TDRS-8 has several anomalies in EPS including the Bus Voltage Limiter (BVL) shunt current, solar array loss of circuits, and failed battery cells. Any of these anomalies can cause critical issues to the spacecraft. Therefore, developing a system to analyze and perform early detection of a potential anomaly is an important issue in telemetry data analysis. In recent years, Telemetry Mining (TM) has been proposed to process telemetry data by using Data Mining (DM) techniques such as classification, clustering, regression and anomaly detection. Anomaly detection, also known as outlier detection, has been widely used in many data mining areas such as remote sensing, medical data processing and digital image processing. The goal of anomaly detection is to detect abnormal data, which contains a relatively low probability of occurrence among the entire data set. Early detection of anomalies is one of the most significant issues in managing the spacecraft configuration. If anomalies can be detected early enough, then the redundant resources can be used to extend the life of the operational spacecraft. We present an unsupervised anomaly detection method to process the EPS data extracted from TDRS-8. This is different from traditional analytical methods, which use telemetry data to illustrate behavior and physical meaning of each spacecraft component. TM connects multiple parameters as a vector and then conducts data analysis on this high dimension telemetry vector. This method is looking at the properties of a high dimensional vector that is able to consider the relationship between different parameters in the anomaly detection problem. This kind of method performs much better than the traditional limit checking method. In addition, we propose a new approach of real-time anomaly detection to process telemetry data in real-time, which can then be applied to spacecraft monitoring with high reliability, low cost and high accuracy.

Machine Learning (ML)↗

Unraveling Na and F coupling effects in stabilizing Li, Mn-rich layered oxide cathodes via local ordering modification

Regardless of the prevailing capacity and energy density of lithium, manganese-rich layered oxide (LMR-NMC) cathodes, continuous decay of voltage and overall energy density during cycling hinders this material from commercialization in Li-ion batteries. Although significant work focuses on single doping of Na and F, analysis in portraying the benefit of these ions in diminishing the structural distortion during activation cycle is in doubt. In this study, the effects of co-doping Na and F into the LMR-NMC structure in stabilizing the structure and mitigating oxygen loss during the first cycle are closely examined via in situ x-ray measurements. Na and F co-doping shows a 30% lower degree of Li + /Ni 2+ mixing in the Li layer (C2/m structure), 50% reduced Debye-Waller factor of Mn-O bonding, increase reversible TM migration, and faster Li diffusion relative to the pristine material. Due to the utilization of Ni redox chemistry below 4.4 V, less oxygen redox is required for charge compensation at high voltage. This study offers the first instance to quantitatively evaluate the effects of co-doping Na and F in LMR-NMC cathode in order to minimize voltage degradation by altering the local ordering of O3-type structure, which may rationalize strategies to overcome the issues of the material.

25 ENERGY STORAGE↗

Capacity Management and Walkdown During LEO Cycling of Nickel-Hydrogen Cells and Batteries

This viewgraph presentation discusses the following topics: 1) Capacity walkdown defined and illustrated; 2) Importance of capacity walkdown: 3) Four approaches to understanding the phenomenon - Pressure Trend, Charging Curve, Electrochemical Voltage Spectroscopy, and Destructive Physical Analysis Studies; 4) Results of the interrelated studies; 5) Suggested mechanism for capacity walkdown; and 6) Charging protocols to avoid the problem. In summary: 1) capacity walkdown is a consequence of the inability to maintain a high state of charge; 2) Capacity loss is typically 35% which would be expected by the valence difference between gamma and beta nickel oxyhydroxide; 3) Cycling at -5 degrees facilitates the formation of the gamma phase; 4) Excessive overcharge can also facilitate gamma phase formation at the expense of cycle life; and 5) Conditions can now be suggested to help minimize capacity walkdown.

Thaller, Lawrence H.↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗