Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-E-T-631: Preliminary Results for Analytical Investigation Into Effects of ArcCHECK Setup Errors

Purpose: As three-dimensional diode arrays increase in popularity for patient-specific quality assurance for intensity-modulated radiation therapy (IMRT), it is important to evaluate an array’s susceptibility to setup errors. The ArcCHECK phantom is set up by manually aligning its outside marks with the linear accelerator’s lasers and light-field. If done correctly, this aligns the ArcCHECK cylinder’s central axis (CAX) with the linear accelerator’s axis of rotation. However, this process is prone to error. This project has developed an analytical expression including a perturbation factor to quantify the effect of shifts. Methods: The ArcCHECK is set up by aligning its machine marks with either the sagittal room lasers or the light-field of the linear accelerator at gantry zero (IEC). ArcCHECK has sixty-six evenly-spaced SunPoint diodes aligned radially in a ring 14.4 cm from CAX. The detector response function (DRF) was measured and combined with inverse-square correction to develop an analytical expression for output. The output was calculated using shifts of 0 (perfect alignment), +/−1, +/−2 and +/−5 mm. The effect on a series of simple inputs was determined: unity, 1-D ramp, steps, and hat-function to represent uniform field, wedge, evenly-spaced modulation, and single sharp modulation, respectively. Results: Geometric expressions were developed with perturbation factor included to represent shifts. DRF was modeled using sixth-degree polynomials with correlation coefficient 0.9997. The output was calculated using simple inputs such as unity, 1-D ramp, steps, and hat-function, with perturbation factors of: 0, +/−1, +/−2 and +/−5 mm. Discrepancies have been observed, but large fluctuations have been somewhat mitigated by aliasing arising from discrete diode placement. Conclusion: An analytical expression with perturbation factors was developed to estimate the impact of setup errors on an ArcCHECK phantom. Presently, this has been applied to simple functions, but is being developed to handle more realistic clinical cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revisiting the HIP 41378 System with K2 and Spitzer

We present new observations of the multiplanet system HIP 41378, a bright star (V = 8.9, K {sub s} = 7.7) with five known transiting planets. Previous K2 observations showed multiple transits of two Neptune-sized bodies and single transits of three larger planets (R {sub P} = 0.33R {sub J}, 0.47R {sub J}, 0.88R {sub J}). K2 recently observed the system again in Campaign 18 (C18). We observe one new transit each of two of the larger planets d/f, giving maximal orbital periods of 1114/1084 days, as well as integer divisions of these values down to a lower limit of about 50 days. We use all available photometry to determine the eccentricity distributions of HIP 41378 d and f, finding that periods ≲300 days require non-zero eccentricity. We check for overlapping orbits of planets d and f to constrain their mutual periods, finding that short periods (P < 300 days) for planet f are disfavored. We also observe transits of planets b and c with Spitzer/Infrared Array Camera (IRAC), which we combine with the K2 observations to search for transit timing variations (TTVs). We find a linear ephemeris for planet b, but see a significant TTV signal for planet c. The ability to recover the two smaller planets with Spitzer shows that this fascinating system will continue to be detectable with Spitzer, CHEOPS, TESS, and other observatories, allowing us to precisely determine the periods of d and f, characterize the TTVs of planet c, recover the transits of planet e, and further enhance our view of this remarkable dynamical laboratory.

79 ASTRONOMY AND ASTROPHYSICS↗

Equipment

A discussion is presented on the problems encountered in designing and constructing a simulator to determine human vestibular response to a range of linear accelerations from 0 to 0.3 g's. Starting with a set of initial performance specifications, the designers combined an array of commercially available components into a system which, altough requiring further refinement before completion, shows considerable promise of fulfilling the initial requirements. The resulting system consists of a wheeled vehicle driven by a cable and drum arrangement, powered by a hydraulic-electric servo-valve. Technical design considerations are presented along with a discussion of the trade-offs between various component options. A description of the system characteristics as well as an analysis of preliminary test results and recommendations for future system improvements are included.

Source record↗

Linear digital imaging system fidelity analysis

The combined effects of imaging gathering, sampling and reconstruction are analyzed in terms of image fidelity. The analysis is based upon a standard end-to-end linear system model which is sufficiently general so that the results apply to most line-scan and sensor-array imaging systems. Shift-variant sampling effects are accounted for with an expected value analysis based upon the use of a fixed deterministic input scene which is randomly shifted (mathematically) relative to the sampling grid. This random sample-scene phase approach has been used successfully by the author and associates in several previous related papers.

Park, Stephen K.↗

An update on the development of a line-focus refractive concentrator array

Concentrator arrays offer a number of generic benefits for space (i.e. high array efficiency, protection from space radiation effects, minimized plasma interactions, etc.). The line-focus refractive concept, however, also offers two very important advantages: (1) relaxation of precise array tracking requirements to only a single axis and (2) low-cost mass production of the lens material. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal errors for satellites having only single-axis tracking capability. New panel designs emphasize light weight, high stiffness, storability, and ease of manufacturing and assembly. This paper addresses the current status of the concentrator program with special emphasis on the design implications, and flexibility, of using a linear refractive concentrator lens as well as details recent fabrication of prototype hardware.

Piszczor, Michael F.↗

An Update on the Development of a Line-Focus Refractive Concentrator Array

Concentrator arrays offer a number of generic benefits for space (i.e. high array efficiency, protection from space radiation effects, minimized plasma interactions, etc.). The line-focus refractive concentrator concept, however, also offers two very important advantages: (1) relaxation of precise array tracking requirements to only a single axis and (2) low-cost mass production of the lens material. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal errors for satellites having only single-axis tracking capability. New panel designs emphasize light weight, high stiffness, stowability and ease of manufacturing and assembly. This paper will address the current status of the concentrator program with special emphasis on the design implications, and flexibility, of using a linear refractive concentrator lens as well as detail the recent fabrication of prototype hardware.

Piszczor, Michael F.↗

Current Status of High Performance Large Format Si:As IBC Detectors for SOFIA-like Applications

Airborne and space telescope astronomical observations in the 5-25 micrometer wavelength region, are critical for understanding the physical conditions, composition, chemistry, and excitation of many environments in the interstellar medium, external galaxies, solar system objects, extra-solar systems, and stars. The scientific impact is particularly unique in the 5-8 micrometer and 14-25 micrometer regions which are inaccessible or poorly observed from ground-based observatories. Large-format area mid-infrared (MIR) detectors sensitive over these wavelengths and operable under moderate backgrounds (greater than 10(circumflex)6 e-/s at R=2000, 10(micrometers)) are essential for efficient large-area survey imaging and for taking moderate resolution spectra over a large spectral range. Both SOFIA and passively cooled Explorer observatories could benefit from this technology. Current first-light SOFIA instruments use small-format MIR FPA's of sizes 128x128 and 256x256, With the collaboration of Raytheon Infrared Operations (RIO), NASA-ARC has been testing the first device of this kind, a combination of 1) the ALADDIN III readout multiplexer, cryo-processed for 6K operation, with 2) SIRTF IRAC-like Sides IBC detector material. designed for higher QE and low dark current. Here we report requirements. design, and initial fabrication and testing of the first 1024x1024 Si:As IBC mid-IR detector array for these conditions. This device has exhibited low dark current, moderate noise levels, and greater than 200,000 electron linear well size at 6K operation. We conclude with suggestions for future device development for optimal performance under moderate background, SOFIA- and low Earth orbit observing conditions.

Ennico, Kimberly↗

Electromagnetic Design of Feedhorn-Coupled Transition-Edge Sensors for Cosmic Microwave Background Polarimetery

Observations of the cosmic microwave background (CMB) provide a powerful tool for probing the evolution of the early universe. Specifically, precision measurement of the polarization of the CMB enables a direct test for cosmic inflation. A key technological element on the path to the measurement of this faint signal is the capability to produce large format arrays of background-limited detectors. We describe the electromagnetic design of feedhorn-coupled, TES-based sensors. Each linear orthogonal polarization from the feed horn is coupled to a superconducting microstrip line via a symmetric planar orthomode transducer (OMT). The symmetric OMT design allows for highly-symmetric beams with low cross-polarization over a wide bandwidth. In addition, this architecture enables a single microstrip filter to define the passband for each polarization. Care has been taken in the design to eliminate stray coupling paths to the absorbers. These detectors will be fielded in the Cosmology Large Angular Scale Surveyor (CLASS).

Chuss, David T.↗

Fast Detection of Material Deformation through Structural Dissimilarity

Designing materials that are resistant to extreme temperatures and brittleness relies on assessing structural dynamics of samples. Algorithms are critically important to characterize material deformation under stress conditions. Here, we report on our design of coarse-grain parallel algorithms for image quality assessment based on structural information and on crack detection of gigabyte-scale experimental datasets. We show how key steps can be decomposed into distinct processing flows, one based on structural similarity (SSIM) quality measure, and another on spectral content. These algorithms act upon image blocks that fit into memory, and can execute independently. We discuss the scientific relevance of the problem, key developments, and decomposition of complementary tasks into separate executions. We show how to apply SSIM to detect material degradation, and illustrate how this metric can be allied to spectral analysis for structure probing, while using tiled multi-resolution pyramids stored in HDF5 chunked multi-dimensional arrays. Results show that the proposed experimental data representation supports an average compression rate of 10X, and data compression scales linearly with the data size. We also illustrate how to correlate SSIM to crack formation, and how to use our numerical schemes to enable fast detection of deformation from 3D datasets evolving in time.

Ushizima, Daniela↗

Regularization of soft-X-ray data in a tokamak application

An image inversion scheme for soft X-ray (SXR) diagnostics at the DIII-D tokamak is developed to obtain the local soft X-ray emission at a poloidal cross-section from the spatially line-integrated image taken by either a set of SXR arrays or a tangential camera. The scheme uses the Tikhonov regularization method since the inversion problem is generally ill-posed. The regularization technique uses the generalized singular value decomposition (GSVD) to determine a solution that depends on a free regularization parameter. The latter has to be chosen carefully, and the so called L -curve method to find the optimum regularization parameter is outlined. A representative test image is used to study the properties of the inversion scheme with respect to inversion accuracy, amount/strength of regularization and image resolution. The SXR arrays thereby represent an under-determined case while the tangential camera is an over-determined case of the linear inversion problem. In conclusion, it is found that the under-determined case suffers from lack of information but can still return a coarse, but fair image, while the camera data can be well inverted with high resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a {sup 153}Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/√(Hz) at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than 10{sup 3} elements and spectral resolving powers R=λ/Δλ>10{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Prediction of hemiwicking dynamics in micropillar arrays

Dynamic hemiwicking behavior is observable in both nature and a wide range of industrial applications ranging from biomedical devices to thermal management. We present a semi-analytical modeling framework (without empirical fitting coefficients) to predict transient capillary-driven hemiwicking behavior of a liquid through a nano/microstructured surface, specifically a micropillar array. In our model framework, the liquid domain is discretized into micropillar unit cells to enable the time marching of the hemiwicking front. A simplified linear pressure drop is assumed along the hemiwicking length such that the local meniscus curvature, contact angle, and effective liquid height are determined at each time step in our transient model. This semi-analytical model is validated with experimental data from our own experiments and from published literature for different fluids. Our model predicts hemiwicking dynamics with <20% error over a broad range of micropillar geometries with height-to-pitch ratio ranging between ≈0.34 and 6.7 and diameter-to-pitch ratio in the range of ≈0.25–0.7 and without any fitting parameters. For lower diameter-to-pitch ratio data points related to sparse micropillar array arrangements, we suggest modifications to the semi-analytical model. This work sheds light on complex and dynamic solid–liquid–vapor interfacial interactions which could serve as a guide for the design of textured surfaces for wicking enhancement in multi-phase thermal and mass transport technologies and applications.

Mechanics↗

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

Assessment of Anisotropic Semiconductor Nanorod and Nanoplatelet Heterostructures with Polarized Emission for Liquid Crystal Display Technology

Semiconductor nanorods can emit linear-polarized light at efficiencies over 80%. Polarization of light in these systems, confirmed through single-rod spectroscopy, can be explained on the basis of the anisotropy of the transition dipole moment and dielectric confinement effects. Here we report emission polarization in macroscopic semiconductor polymer composite films containing CdSe/CdS nanorods and colloidal CdSe nanoplatelets. Anisotropic nanocrystals dispersed in polymer films of poly butyl-co-isobutyl methacrylate (PBiBMA) can be stretched mechanically in order to obtain unidirectionally aligned arrays. A high degree of alignment, corresponding to an orientation factor of 0.87, was achieved and large areas demonstrated polarized emission, with the contrast ratio I-parallel to/I-perpendicular to= 5.6, making these films viable candidates for use in liquid crystal display (LCD) devices. To some surprise, we observed significant optical anisotropy and emission polarization for 2D CdSe nanoplatelets with the electronic structure of quantum wells. The aligned nanorod arrays serve as optical funnels, absorbing unpolarized light and re-emitting light from deep-green to red with quantum efficiencies over 90% and high degree of linear polarization. Our results conclusively demonstrate the benefits of anisotropic nanostructures for LCD backlighting. The polymer films with aligned CdSe/CdS dot-in-rod and rod-in-rod nanostructures show more than 2-fold enhancement of brightness compared to the emitter layers with randomly oriented nanostructures. This effect can be explained as the combination of linearly polarized luminescence and directional emission from individual nanostructures.

liquid crystal display↗

Comparisons Between Array Derived Dynamic Strain Rate (ADDS) and Fiber‐Optic Distributed Acoustic Sensing (DAS) Strain Rate

Abstract Distributed acoustic sensing (DAS) strain rate and particle velocity can be compared through approximate scaling with medium velocity. We instead performed a direct comparison between array derived dynamic strain (ADDS) rate and DAS strain rate for six frequency bands. The PoroTomo project at Brady's Hot Springs, Nevada, deployed a 240‐geophone 3C array co‐located with fiber‐optic DAS system and 8.7 km of buried cable. We selected subsets of the geophone array to create four smaller arrays and computed ADDS. The horizontal components of the ADDS were rotated into the direction of the fiber‐optic cable and then compared with the observed DAS strain rates. From three example regional earthquakes of local magnitudes 2.9, 4.1, and 4.3, the ADDS are found to be coherent with DAS for frequencies ≤1 Hz. For frequencies >1‐Hz, this correlation decays quickly. Small differences between linear and areal dynamic strains at 1‐Hz suggest poor signal‐to‐noise or localized strain that is perturbed by shallow heterogeneities compare to the average strain propagating across the geophone array. The implication is that around 1‐Hz, straight fiber DAS is measuring axial strain along the fiber and can provide good approximations to translational particle motions. However, above 1‐Hz, DAS becomes more sensitive to shallow velocity gradients that can be beneficial for geophysical imaging yet becomes a limitation for traditional seismic analysis methods depending on absolute amplitude and phase from translational particle motions.

58 GEOSCIENCES↗