Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Microstructure and defect engineering of graphite anodes by pulsed laser annealing for enhanced performance of lithium-ion batteries

We report nanosecond pulsed laser annealing significantly improves cyclability and current carrying capacity of lithium-ion batteries (LIBs). This improvement is achieved by engineering of microstructure and defect contents present in graphite in a controlled way by using pulsed laser annealing (PLA) to increase the number density of Li + ion trapping sites. The PLA treatment causes the following changes: (1) creates surface steps and grooves between the grains to improve Li + ion charging and intercalation rates; (2) removes inactive polyvinylidene difluoride (PVDF) binder from the top of graphite grains and between the grains which otherwise tends to block the Li + migration; and (3) produces carbon vacancies in (0001) planes which can provide Li + charging sites. From X-ray diffraction data, we find upshift in diffraction peak or reduction in planar spacing, from which vacancy concentration was estimated to be about 1.0%, which is higher than the thermodynamic equilibrium concentration of vacancies. The laser treatment creates single and multiple C vacancies which provide sites for Li + ions, and it also produces steps and grooves for Li + ions to enter the intercalating sites. It is envisaged that the formation of these sites enhances Li+ ion absorption during charge and discharge cycles. The current capacity increases from an average 360 mAh/g to 430 mAh/g, and C–V shows significant reduction in SEI layer formation after the laser treatment. If the vacancy concentration is too high and charge-discharge cycles are long, then trapping of electrons by Li + may occur, which can lead to Li 0 formation and Li plating causing reduction in current capacity.

25 ENERGY STORAGE↗

Near fifty percent sodium substituted lanthanum manganites—A potential magnetic refrigerant for room temperature applications

Nearly half of lanthanum sites in lanthanum manganites were substituted with monovalent ion-sodium and the compound possessed distorted orthorhombic structure. Ferromagnetic ordering at 300 K and the magnetic isotherms at different temperature ranges were analyzed for estimating magnetic entropy variation. Magnetic entropy change of 1.5 J·kg{sup −1}·K{sup −1} was observed near 300 K. An appreciable magnetocaloric effect was also observed for a wide range of temperatures near 300 K for small magnetic field variation. Heat capacity was measured for temperatures lower than 300 K and the adiabatic temperature change increases with increase in temperature with a maximum of 0.62 K at 280 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source

An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.

43 PARTICLE ACCELERATORS↗

Hyperspectral reflectance as a tool to measure biochemical and physiological traits in wheat

Improving photosynthesis to raise wheat yield potential has emerged as a major target for wheat physiologists. Photosynthesis-related traits, such as nitrogen per unit leaf area (N area ) and leaf dry mass per area (LMA), require laborious, destructive, laboratory-based methods, while physiological traits underpinning photosynthetic capacity, such as maximum Rubisco activity normalized to 25 °C (V cmax25 ) and electron transport rate (J), require time-consuming gas exchange measurements. The aim of this study was to assess whether hyperspectral reflectance (350–2500 nm) can be used to rapidly estimate these traits on intact wheat leaves. Predictive models were constructed using gas exchange and hyperspectral reflectance data from 76 genotypes grown in glasshouses with different nitrogen levels and/or in the field under yield potential conditions. Models were developed using half of the observed data with the remainder used for validation, yielding correlation coefficients (R 2 values) of 0.62 for V cmax25 , 0.7 for J, 0.81 for SPAD, 0.89 for LMA, and 0.93 for N area , with bias <0.7%. The models were tested on elite lines and landraces that had not been used to create the models. The bias varied between -2.3% and -5.5% while relative error of prediction was similar for SPAD but slightly greater for LMA and N area .

59 BASIC BIOLOGICAL SCIENCES↗

Wind Resource Assessment of Gujarat (India)

India is one of the largest wind energy markets in the world. In 1986 Gujarat was the first Indian state to install a wind power project. In February 2013, the installed wind capacity in Gujarat was 3,093 MW. Due to the uncertainty around existing wind energy assessments in India, this analysis uses the Weather Research and Forecasting (WRF) model to simulate the wind at current hub heights for one year to provide more precise estimates of wind resources in Gujarat. The WRF model allows for accurate simulations of winds near the surface and at heights important for wind energy purposes. While previous resource assessments published wind power density, we focus on average wind speeds, which can be converted to wind power densities by the user with methods of their choice. The wind resource estimates in this study show regions with average annual wind speeds of more than 8 m/s.

17 WIND ENERGY↗

Analysis of the Cost and Value of Concentrating Solar Power in China

As an emerging technology in China, the cost and value of CSP is not very well understood. This study is an attempt to provide the context of CSP development in China, as well as the basic data and methods for analyzing CSP in the power system. Because China does not have established power markets in the region we analyze, our value analysis focus on the impact to system operation cost, even though CSP bring a range of values including capacity and ancillary services. The report is divided into five parts. Following the introduction, we provide an overview of CSP technologies and potentials in China, and the policy and regulatory environment for CSP development. Then we dive into a literature review of LCOE estimations for CSP and uses the System Advisor Model to analyze the LCOEs for CSPs in China with different configurations of solar multiples and hours of storage. We also build an economic dispatch model to analyze the hourly system operations with different configurations of CSP. Finally, we conclude the report with areas for further research.

14 SOLAR ENERGY↗

Biopower: Impact of Biofuels Deployment to Replace Petroleum Liquids in Stationary Power Applications

Petroleum-based liquids are used in a portion of power generation applications in the United States, predominantly in the New England, Middle Atlantic, South Atlantic, and Pacific-Noncontiguous regions. Power plants that burn petroleum liquids, such as distillate or residual fuel oils, are generally used for short periods to accommodate peak electricity demands. The Energy Information Administration (EIA) estimated the U.S. consumption of petroleum liquids for electricity generation at 27 million barrels in 2018, representing a cost of $2.4 billion annually. This study assesses the potential to displace all or part of the petroleum liquids in U.S. power generation with biofuels. The biofuels for this application are assumed to be derived from terrestrial feedstocks, with conversion routes of both fast pyrolysis (bio-oil) and hydrothermal liquefaction (bio-crude). Regional models were used to assess the availability and cost of three different base materials: clean wood, forest residues, and corn stover; each was evaluated in the laboratory at small or experimental scales for conversion to bio-oil or bio-crude. The estimated biofuel production quantities depend on equivalent heating versus the current heavy fuel. In this report, the availability of each type of biomass for each section of the U.S. Census division is estimated using a conservative broker price (in each case) of $ 80 per dry tonne. The results show that the petroleum-liquid power generation in each of the Census Divisions could be supplied by one or more of the feedstocks evaluated. For all regions, clean wood supplies (only) could provide ample supply. For all but two regions (Middle Atlantic and New England), forest residues alone are sufficient. Finally, for all regions but three (Middle Atlantic, New England, and South Atlantic), corn stover alone is adequate. The Minimum Fuel Selling Price (MFSP) of bio-oil and bio-crude were also estimated for each feedstock type and Census Division. This analysis showed that fast pyrolysis bio-oil projections to be lower (14% on average) than current wholesale petroleum-based heating oil prices in each of the regions, assuming 100 dry tonnes/day processing capacity. However, bio-crude predictions were significantly higher (2X) in all cases. The effect of biorefinery size was also quantified. Based on the preliminary results in this study, it is apparent the biofuels could be an economical alternative for current petroleum liquids in U.S. power generation. However, additional research is needed to determine the necessary biofuel characteristics to support existing generation equipment. It is recommended that both power generation and biofuel production stakeholders to be engaged to outline the research and testing needed to identify the technical hurdles to enable the opportunity.

02 PETROLEUM↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grout long radius flow testing to support Saltstone disposal Unit 5 design

The Saltstone Facility, located within the Savannah River Site (SRS) near Aiken, South Carolina, consists of two facility segments: The Saltstone Production Facility (SPF) and the Saltstone Disposal Facility (SDF). The SPF receives decontaminated legacy low level sodium salt waste solution that is a byproduct of prior nuclear material processing. The salt solution is mixed with cementitious materials to form a grout slurry known as “Saltstone”. The grout is pumped to the SDF where it is placed in a Saltstone Disposal Unit (SDU) to solidify. SDU 6 is referred to as a “mega vault” and is currently in the design stage. The conceptual design for SDU 6 is a single cell, cylindrical geometry approximately 114.3 meters in diameter by 13.1 meter high and is larger than previous cylindrical SDU designs, 45.7 meters in diameter by 7.01 meters high (30 million gallons versus 2.9 million gallons of capacity). Saltstone slurry will be pumped into the new waste disposal unit through roof openings at a projected flow rate of about 34.1 cubic meters per hour. Nine roof openings are included in the design to discharge material into the SDU with an estimated grout pour radius of 22.9 to 24.4 meters and initial drop height of 13.1 meters. The conceptual design for the new SDU does not include partitions to limit the pour radius of the grout slurry during placement other than introducing material from different pour points. This paper addresses two technical issues associated with the larger diameter of SDU 6; saltstone flow distance in a tank 114.3 meters in diameter and quality of the grout. A long-radius flow test scaled to match the velocity of an advancing grout front was designed to address these technology gaps. The emphasis of the test was to quantify the flow distance and to collect samples to evaluate cured properties including compressive strength, porosity, density, and saturated hydraulic conductivity. Two clean cap surrogate mixes (saltstone premix plus water) were designed to simulate slurry with the reference saltstone rheology and a saltstone with extra water from the process flushing operation. Long-radius flow tests were run using approximately 4.6 cubic meters of each of these mixes. In both tests the pump rate was 0.063 liters/second (1 gpm). A higher pump rate, 0.19 liters/second (3 gpm), was used in a third long-radius flow test. The angle of repose of the grout wedges increased as a function of time in all three tests. The final angles of repose were measured at 3.0º, 2.4º, and 0.72º. The pump rate had the largest effect on the radial flow distance and slope of the grout surface. The slope on the pour placed at 0.19 liters/second (3 gpm) was most representative of the slope on the grout currently being pumped into SDU 2 which is estimated to be 0.7º to 0.9º. The final grout heights at 1/3 of a meter from the discharge point were 115, 105, and 38 cm. Entrapped air (≥ 0.25 cm bubbles) was also observed in all of the mixes. The entrapped air appeared to be released from the flows within about 3.1 meters (10 feet) of the discharge point. The bleed water was clear but had a thin layer of floating particulates. The bleed water should be retrievable by a drain water collection system in SDU 6 assuming the system does not get clogged. Layering was observed and was attributed to intervals when the hopper was being cleaned. Heat from the hydration reactions was noticeable to the touch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grout Long Radius Flow Testing to Support Saltstone Disposal Unit 6 Design - 13352

The Saltstone Facility, located within the Savannah River Site (SRS) near Aiken, South Carolina, consists of two facility segments: The Saltstone Production Facility (SPF) and the Saltstone Disposal Facility (SDF). The SPF receives decontaminated legacy low level sodium salt waste solution that is a byproduct of prior nuclear material processing. The salt solution is mixed with cementitious materials to form a grout slurry known as 'Saltstone'. The grout is pumped to the SDF where it is placed in a Saltstone Disposal Unit (SDU) to solidify. SDU 6 is referred to as a 'mega vault' and is currently in the design stage. The conceptual design for SDU 6 is a single cell, cylindrical geometry approximately 114.3 meters in diameter by 13.1 meter high and is larger than previous cylindrical SDU designs, 45.7 meters in diameter by 7.01 meters high (30 million gallons versus 2.9 million gallons of capacity). Saltstone slurry will be pumped into the new waste disposal unit through roof openings at a projected flow rate of about 34.1 cubic meters per hour. Nine roof openings are included in the design to discharge material into the SDU with an estimated grout pour radius of 22.9 to 24.4 meters and initial drop height of 13.1 meters. The conceptual design for the new SDU does not include partitions to limit the pour radius of the grout slurry during placement other than introducing material from different pour points. This paper addresses two technical issues associated with the larger diameter of SDU 6; Saltstone flow distance in a tank 114.3 meters in diameter and quality of the grout. A long-radius flow test scaled to match the velocity of an advancing grout front was designed to address these technology gaps. The emphasis of the test was to quantify the flow distance and to collect samples to evaluate cured properties including compressive strength, porosity, density, and saturated hydraulic conductivity. Two clean cap surrogate mixes (Saltstone premix plus water) were designed to simulate slurry with the reference Saltstone rheology and a Saltstone with extra water from the process flushing operation. Long-radius flow tests were run using approximately 4.6 cubic meters of each of these mixes. In both tests the pump rate was 0.063 liters/second (1 gpm). A higher pump rate, 0.19 liters/second (3 gpm), was used in a third long-radius flow test. The angle of repose of the grout wedges increased as a function of time in all three tests. The final angles of repose were measured at 3.0 deg., 2.4 deg., and 0.72 deg.. The pump rate had the largest effect on the radial flow distance and slope of the grout surface. The slope on the pour placed at 0.19 liters/second (3 gpm) was most representative of the slope on the grout currently being pumped into SDU 2 which is estimated to be 0.7 deg. to 0.9 deg. The final grout heights at 1/3 of a meter from the discharge point were 115, 105, and 38 cm. Entrapped air (≥ 0.25 cm bubbles) was also observed in all of the mixes. The entrapped air appeared to be released from the flows within about 3.1 meters (10 feet) of the discharge point. The bleed water was clear but had a thin layer of floating particulates. The bleed water should be retrievable by a drain water collection system in SDU 6 assuming the system does not get clogged. Layering was observed and was attributed to intervals when the hopper was being cleaned. Heat from the hydration reactions was noticeable to the touch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Definition of Capabilities Needed for a Single Event Effects Test Facility

The Federal Aviation Administration (FAA) is contemplating new regulations mandating testing of the vulnerability of flight-critical avionics to single event effects (SEE). A limited number of high-energy neutron test facilities currently serve the SEE industrial and institutional research community. The FAA recognizes that existing facilities have insufficient test capacity to meet new demand from such mandates; it desires more flexible irradiation capabilities to test complete, large systems and would like capabilities to address greater concerns for thermal neutrons. For this reason, the FAA funded this study by Spallation Neutron Source (SNS) staff with the ultimate aim of developing options for SEE test facilities using high-energy neutrons at the SNS complex. After an investigation of current SEE test practices and assessment of future testing requirements, three concepts were identified covering a range of test functionality, neutron flux levels, and fidelity to the atmospheric neutron spectrum. The costs and times required to complete each facility were also estimated. SEE testing is generally performed by accelerating the event rate to a point where the effects are still dominated by single events and double event causes of failures are negligible. In practice, acceleration factors of as high as 10 6 are applicable for component testing, whereas for systems testing acceleration factors of 10 4 seem to be the upper limit. It is strongly desirable that the irradiation facility be tunable over a large range of high-energy neutron fluxes of 10 2 - 10 4 n/cm²/s for systems testing and from 10 4 - 10 7 n/cm²/s for components testing. The most capable, most flexible, and highest-test-capacity option is a new stand-alone target station named the High-Energy neutron Test Station (HETS). It is also the most expensive option, with a cost to complete of approximately $100 million. Dual test enclosures would allow for simultaneous testing activity effectively doubling overall test capacity per HETS operating hour. Using about 1 kilowatt (kW) of proton power extracted from the accelerator before injection in the accumulator ring, its operation would be unnoticeable by neutron scattering users at the SNS target station. The H beam laser stripping technique would allow for control of beam power on the HETS target independent from power delivered to the SNS. Large systems with frontal areas of up to 1 x 2 m² could be accommodated with integral high-energy flux values (above 10 megaelectron-volt, or MeV) to at most 10 4 n/cm²/s; components could also be tested with flux levels to at most 10 7 n/cm²/s on beam sizes of up to 0.2 x 0.2 m². Selectable moderating material and neutron filters would allow tailoring of the neutron spectrum to user demands; charged particle deflectors could be switched to allow or deflect protons, pions, and muons. It is estimated that HETS would take 5 years to complete after award of contract, including engineering design and construction. Commissioning would take at least another 6 months. Interference with SNS principal operations was not considered in the construction time estimate; connection of the proton transport line and tunnel from the accelerator high energy beam transport (HEBT) and construction around existing site utilities would require careful planning and coordination with beam operations at the SNS. A high-energy (HE) neutron test facility using an available beam line on the SNS target station is a technically and financially attractive option. Inspired by the new ChipIR instrument on the ISIS TS 2 spallation source in the UK, a similar facility could be placed on an unused beam line in the SNS instrument hall [e.g., on beam line 8 (both A and B channels would be needed) or on beam line 10]. The performance would approach that of an HETS (~80%), but it would be operationally more limited, with only a single user at a time. Space is more limited, so the maximum system size would be about half of that in an HETS. Flexibility to tailor the spectrum would be somewhat more limited. While this concept was not as fully developed and characterized, preliminary work indicates very high HE flux levels should be possible, with ample thermal neutrons as well. Flux control would be more difficult than at HETS because proton power on target be whatever the SNS was operating at for neutron scattering. Neutron attenuation devices would have to be employed with as-yet undetermined control resolution. However, no new buildings would be needed, and the necessary utilities are already present in the SNS Experiment Hall. The estimated cost for a beam line option is around $15 million; the time to complete would be 3 years after award of contract, plus at least 6 months for commissioning. Interference of construction activities with SNS operations should be negligible. This option would require negotiation with the Department of Energy Basic Energy Sciences (BES) office -- the primary stakeholder of SNS -- for an application outside the usual scope of neutron scattering sciences. Furthermore, these presently open beam lines are highly desirable locations for proposed neutron scattering instruments and obtaining one of them for an SEE test facility will come only with persuasive and timely arguments to SNS leadership and the DOE BES. The third option is a tunnel extension/target cave facility providing the most basic system-level irradiation capability with minimal flexibility. Again not as well developed a concept as HETS, it would use a laser-stripping technique like an HETS, redirecting protons to a tunnel similar to the initial HETS proton transport tunnel. Indeed, this concept is intended to be upgradable to a full HETS facility. Only a small fraction of a watt of proton power would be used in this basic configuration, though. An uncooled target and primitive shielding arrangement would provide beam on modestly sized systems that must be placed in close proximity to the target. The neutron fluence would be less uniform over the system than with the HETS or the beam line option. A data acquisition room and support area would be located on the ground level; access to the target cave would be via elevator and/or stairway. As a result of the required excavation, new tunnel construction, shielding, data acquisition building, utilities, and other items, the estimated cost is $30 million. The time to complete is expected be more than 3 years; here again construction interference with SNS operations has not been accounted for, but it could have a significant impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mapping foliar photosynthetic capacity in sub-tropical and tropical forests with UAS-based imaging spectroscopy: Scaling from leaf to canopy

Accurate understanding of the variability in foliar physiological traits across landscapes is critical to improve parameterization and evaluation of terrestrial biosphere models (TBMs) that seek to represent the response of terrestrial ecosystems to a changing climate. Numerous studies suggest imaging spectroscopy can characterize foliar biochemical and morphological traits at the canopy scale, but there is only limited evidence for retrieving canopy photosynthetic capacity (e.g., maximum carboxylation rate, V c,max and maximum electron transport rate, J max ). Moreover, the effect of canopy structure within forest communities on scaling up spectra-trait relationships from leaf to canopy level is not well known. To advance the spectra-trait approach and enable the estimation of key traits using remote sensing, we collected imaging spectroscopy data from an Unoccupied Aerial System (UAS) platform over two forest sites in China (a subtropical forest in Mt. Dinghu and a tropical rainforest in Xishuangbanna). At these sites, we also collected ground measurements of leaf spectra and traits, including biochemical (leaf nitrogen, phosphorus, chlorophyll, and water content), morphological (leaf mass per area, LMA) and physiological (V c,max25 and J max25 ) traits (n=135 tree-crowns from 42 species across two sites). Using a partial least-squares regression (PLSR) approach, we built and tested spectra-trait models with repeated cross-validation. The spectral models developed with leaf spectra were directly transferred to canopy spectra to evaluate the effect of canopy structure. Here we further applied canopy spectral models to map these traits at individual tree-crown scale. The results demonstrate that (1) UAS-based canopy spectra can be used to estimate V c,max (R 2 =0.55, nRMSE=11.79%), Jmax (R 2 =0.54, nRMSE=12.34%), and five additional foliar traits (R 2 =0.38-0.60, nRMSE=10.11-13.56%) at the tree-crown scale with demonstrated generalizability across two sites; (2) canopy structure strongly affects the spectratrait relationships from leaf to canopy level, but the effects vary considerably across foliar traits and cannot be well captured by the 4SAIL canopy radiative transfer model. UAS-based imaging spectroscopy maps large variability in all foliar traits (including physiological traits) with spatially explicit information, reproducing the field-observed inter- and intra-specific variations. These results demonstrate the capability of using UAS-based imaging spectroscopy for characterizing the variability of foliar physiological traits at individual tree-crown scale over forest landscapes and highlight the similar generalizability but different biophysical mechanisms underlying spectra-trait relationships at leaf and canopy levels.

54 ENVIRONMENTAL SCIENCES↗

Reservoir Thermal Energy Storage Benchmarking (Rev. 3)

A benchmarking analysis of RTES research funded by GTO through the Beyond Batteries projects was conducted against the ESGC to see where they fit within the identified ESGC Use Cases. The projects were found to advance knowledge in multiple ESGC use cases, either directly or in some cases, indirectly as enabling technologies. This analysis is helpful to understand where RTES and associated research fits into the larger discussion around energy storage technologies. Also, a retrospective analysis of the Beyond Batteries projects was conducted to evaluate what the projects learned and how the results can be applied to advance the value of RTES. Major results of each of the studies are summarized in Table 2. Additionally, a comparative metrics analysis for RTES was completed to understand where RTES lies within the energy storage industry. Metrics for evaluation of RTES and its comparison to other storage technologies were selected and ranges of their values compiled. The selected metrics – LCOE (levelized cost of energy), capital costs, roundtrip efficiency, energy storage capacity, and storage time – were chosen based on data availability and have a particularly strong influence on the potential deployment of a storage technology. Charts which compare the metrics are presented in section 4.3 and show ranges for each of the 10 selected technologies. However, due to a lack of domestic operational facilities, values for RTES and for portions of the remaining technologies are based on theoretical modeling and studies of best-case scenarios. LCOE estimates for RTES fall within the lower reaches of Figure 15, but nevertheless amount to 2 – 5 times the ESGC Roadmap goal for LCOE, for example in the Facilitating and Evolving Grid Use Case. Capital costs for RTES sit on the higher end (Figure 16) but are expected to decrease as new projects are developed and the technology is refined. The theoretical roundtrip efficiency reported for RTES varies from mid to high percentages (Figure 17) with efficiencies upwards of 93% in modeled scenarios in the Portland Basin (Bershaw et al.,2020). RTES is also expected to have the largest energy storage capacities and longest storage times, likely matched only by lower efficiency hydrogen storage. To better assess the role that RTES could play in energy storage we examined it’s potential in the U.S. The potential depends on many factors. Recently, many researchers have started looking at deep sedimentary basins, depleted oil and gas fields, and basalt formations as potential targets for RTES development. The United States Geological Survey (USGS) has analyzed various cities and shown substantial RTES potential in the cooling sector (Pepin et al., 2021). By modeling RTES in low-quality groundwater (e.g., brackish), it is shown to be favorable across the U.S. with particular suitability in the Illinois Basin, Coastal Plains, and Basin and Range regions. Seasonal RTES operations have also been modeled in the Portland Basin by those at the USGS and Portland State University to simulate an RTES system supplying heating loads needed for the Oregon Health and Science University. Simulations suggest that high conductive heat loss in the initial years exists but tends to decrease with increasing time and development of the resource due to self-insulating nature of the basalts (Burns et al., 2020). Other national laboratory efforts are taking a close look at many of the technical issues involved with RTES (McLing et al., 2019, McLing et al., 2022). These include difficulties in understanding geochemical, hydrogeological, mechanical, and microbiological changes at such elevated temperatures and operational scenarios. Major gaps in research are identified and suggested for future work. With this increased focus to understand how to make RTES successful in the U.S., this technology could be a potential solution to many of the nation’s energy storage problems. For the energy independence of this country, the DOE should prioritize de-risking this technology by making future investments in pilot-scale demonstrations to attract potential investors.

15 GEOTHERMAL ENERGY↗

Probability of Pinching Failure in PWR SNF after Long-Term Storage

A probabilistic assessment was performed on pinching failure of PWR SNF rod cladding under accidental SNF cask transport conditions. a set of 3,000 rod pinching scenarios was analyzed, with different geometrical, material, and loading parameters, using a Latin Hypercube Sampling (LHS). The investigated accidents include train derailments leading to cask collisions or cask drops. Pinching failure was related to cladding offset strain, defined as the plastic deformation interval in radial cladding direction normalized with respect to the outer cladding diameter. Finite element (FE) models were used to compute SNF rod deformations and the offset strain demand OSD in each of the assessed pinching scenarios. The numerical models account for the contribution of the degraded fuel pellets to rod pinching stiffness. The offset strain capacity OSC was computed using regression and interpolation models based on ring compression (RCT) test results, and account for hydride-related effects on cladding ductility. The results show a low probability of pinching failure. Hydride-related cladding embrittlement affects the structural integrity of PWR SNF rods after long-term dry storage of up to 300 years. Radial hydride patterns or large amounts of circumferentially oriented hydrides reduce the cladding ductile deformation capability when pinched at low material temperatures. The probability of hydride-related pinching failure of PWR cladding is estimated after long-term dry storage to address: How do PWR SNF rod conditions like hydrogen content, vacuum drying peak cladding hoop stress σ{sub θ}, and cladding material temperature affect cladding ductility? Is hydride-related cladding embrittlement a material degradation mechanism that affects the structural integrity of PWR SNF rods under pinching loading? What are the controlling parameters for deformation demands in PWR SNF rods under pinching loading? Is the pinching load amplitude an important parameter that controls the probability of pinching failure? How do parameters like pellet-cladding gap or fuel pellet degradation affect the pinching loading capacity of PWR SNF rods? Statistical modelling of PWR SNF rod conditions in U.S. inventory: A pseudo rod database was generated based on EIA database. Analysis of train accident scenarios: a probability density function (pdf) of a pinching load distribution P{sub 9m} of a 9-m cask drop is linearly scaled to generate a more representative: distribution P{sub AS}. The new distribution considers train collision velocities, cask drops for on- and off-bridge accidents, and cask impact orientation. LHS generates 3,000 rod pinching scenarios based on nine independent geometrical, material, and loading parameters. Probabilistic FE Analysis: The LHS realizations are used to generate 3,000 FE models. The FE analysis is conducted for P{sub 9m}, and P{sub AS}. The workflow is automatized. The OSC is computed with regression and interpolation models, as a function of the hydrogen content C{sub H}, vacuum drying peak σ{sub θ}, and SNF temperature T{sub FR}: The regression data was obtained in RCTs on PWR cladding. The OSD is derived from the cladding deformations in the FE models. Cladding failure was identified via a comparison of OSC and OSD. A 300 and a 30 years-of-dry-storage duration is investigated: The dry-storage period affects the expected SNF temperature and consequently, the OSC and the OSD. The material temperature LHS population is adapted to account for a SNF temperature variation. The probability of hydride-related, ductile cladding failure during a severe transportation accident is not significantly affected by the pinching load amplitude: The probability is slightly reduced from a range of less than 0.0333% to 0.1667% for P{sub 9m}, to a range of less than 0.0333% to 0.1333% for P{sub AS}, depending on the vacuum drying peak cladding hoop stress modelling assumptions. Further, the SNF dry-storage duration does not significantly affect the probability of ductile pinching failure. Based on available train accidents data, the pinching failure probability for a 5,000 km long transportation route ranges from less than 1.62 E-7 to a value of 6.47 E-7, depending on the vacuum drying peak cladding hoop stress modelling assumptions. The pinching load amplitude is not a controlling parameter for the probability of ductile cladding pinching failure, and does not control the cladding deformations once pellet-cladding contact is established, The pellet-cladding gap width, however, plays a key role. Fuel pellet degradation only affects the deformation capacity, if the pellet stiffness is significantly reduced (more than 90%). Only highly embrittled cladding is likely to fail. The deformation demands on the cladding under pinching loading are small.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary Waste Form Screening Test Results—THOR® Fluidized Bed Steam Reforming Product in a Geopolymer Matrix

Screening tests are being conducted to evaluate waste forms for immobilizing secondary liquid wastes from the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Plans are underway to add a stabilization treatment unit to the Effluent Treatment Facility to provide the needed capacity for treating these wastes from WTP. The current baseline is to use a Cast Stone cementitious waste form to solidify the wastes. Through a literature survey, DuraLith alkali-aluminosilicate geopolymer, fluidized-bed steam reformation (FBSR) granular product encapsulated in a geopolymer matrix, and a Ceramicrete phosphate-bonded ceramic were identified both as candidate waste forms and alternatives to the baseline. These waste forms have been shown to meet waste disposal acceptance criteria, including compressive strength and universal treatment standards for Resource Conservation and Recovery Act (RCRA) metals (as measured by the toxicity characteristic leaching procedure [TCLP]). Thus, these non-cementitious waste forms should also be acceptable for land disposal. Information is needed on all four waste forms with respect to their capability to minimize the release of technetium. Technetium is a radionuclide predicted to be in the secondary liquid wastes in small quantities, but the Integrated Disposal Facility (IDF) risk assessment analyses show that technetium, even at low mass, produces the largest contribution to the estimated IDF disposal impacts to groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗

Radiation-Chemical Synthesis of Crosslinked Films Based on N-Vinylcaprolactam Copolymers

Water-soluble copolymers were obtained by graft copolymerization of N-vinylcaprolactam and 2-hydroxyethyl acrylate on polyvinyl alcohol. The chemical composition of the obtained graft copolymers was determined by IR spectroscopy. Cross-linked films were obtained by radiation treatment of water-soluble copolymers. To estimate the efficiency of the radiation crosslinking of films, the dependence of the yield of gel fraction on the absorbed dose was studied at different proportions of the initial components. It was established that the yield of the crosslinked fraction increases and the swelling capacity of polymer mesh decreases with increasing 2-hydroxyethyl acrylate content in graft copolymer and absorbed dose.

60 APPLIED LIFE SCIENCES↗