Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution X-ray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell↗

Nature and origin of interstellar diamond from the Allende CV3 meteorite

Data and experimental evidence which support the contention that the C delta diamonds may result from grain-grain collisions in supernova shocks in the interstellar medium are presented. Fragments of the Allende CV3 chondrite were acid-treated. A whitish powder was obtained. For the Analytical Electron Microscopy (AEM) a small drop of ethanol suspension was transferred onto holey carbon support films on 3 mm EM grids. The AEM was performed on transmission-thin fragments of the material which overlay holes in the film, to eliminate interference from the substrate. Electron Spectroscopy for Chemical Analysis (ESCA) was performed on a large aliquot of C. Diamond was identified by selected area electron diffraction. Scanning Transmission Electron Microscope / Energy Dispersive X-ray (STEM-EDS) microanalyses of the C delta diamond, using a light-element detector, show that oxygen and possibly nitrogen are the only impurities consistently present. ESCA spectra from bulk C delta material confirm the presence of N at a level of 0.35 percent or less. Under UV irradiation a yellow-red fluorescence is observed, consistent with that of natural diamonds containing substitutional N. Electron Energy Loss Spectra (EELS) were recorded at 2 eV resolution from the C delta diamond, high pressure synthetic diamond, a diamond film produced in a low pressure plasma by chemical vapor deposition (CVD) on a heated silicon substrate (Roy, 1987), graphite, and amorphous arc sputtered carbon. Comparison of the carbon K edge shape and fine structure shows the Allende C delta phase to be largely diamond, but with a significant pre-edge absorption feature indicative of transitions of C 1s electrons into pi asterisk orbitals which are absent in the purely sp(3)-bonded diamond but present in graphite and amorphous carbon.

Blake, David↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.↗

Magnetoelastic-coupling-assisted first-order antiferromagnetic transitions in the corrugated honeycomb-lattice compounds (Ca, Sr) ⁢Mn 2 ⁢ P 2

Understanding the origin of unconventional magnetic order is a central theme in the research field of functional quantum materials for spin-dependent applications. In general, a paramagnetic (PM) to antiferromagnetic (AFM) transition is of thermodynamically second order in nature in the absence of a magnetic field. In the magnetically frustrated corrugated-honeycomb lattice compounds (Ca, Sr) ⁢Mn 2 ⁢ P 2 , electrical resistivity 𝜌 measurements in the 𝑎⁢𝑏 plane are reported to exhibit sharp discontinuities at the respective PM to AFM ordering temperatures 𝑇 N = 69.5 and 53 K, respectively, signifying the unusual first-order nature of the AFM transition. To reveal the origin of such anomalous transitions, high-resolution linear thermal-expansion measurements are reported for both CaMn 2 ⁢P 2 and SrMn 2 ⁢ P 2 in the 𝑎⁢𝑏 plane and along the 𝑐 axis using capacitance dilatometry. The thermal expansion measurements show a sharp discontinuity in Δ⁢𝐿/𝐿 at 𝑇 N , yielding a diverging behavior in the thermal expansion coefficient 𝛼⁡(𝑇) associated with strong magnetoelastic coupling, driving the first-order AFM transition in CaMn 2 ⁢P 2 . However, this effect is weaker in SrMn 2 ⁢P 2 , consistent with the magnetic entropy changes 𝑆⁡(𝑇) obtained from the heat-capacity measurements. Temperature-dependent 𝑎⁢𝑏-plane x-ray diffraction measurements for CaMn 2 ⁢ P 2 near its 𝑇 N yield a volume thermal expansion coefficient consistent with literature data for other materials. The uniaxial pressure derivatives of 𝑇 N in the two compounds are found to be respectively opposite in sign, presumably due to the different magnetic structures.

Pakhira, Santanu [Maulana Azad National Institute ↗

Learning neural representations for X-ray ptychography reconstruction with unknown probes

X-ray ptychography provides exceptional nanoscale resolution and is widely applied in materials science, biology, and nanotechnology. However, its full potential is constrained by the critical challenge of accurately reconstructing images when the illuminating probe is unknown. Conventional iterative methods and deep learning approaches are often suboptimal, particularly under the low-signal conditions inherent to low-dose and high-speed experiments. These limitations compromise reconstruction fidelity and restrict the broader adoption of the technique. In this work, we introduce the Ptychographic Implicit Neural Representation (PtyINR), a self-supervised framework that simultaneously addresses the object- and probe-recovery problem. By parameterizing both as continuous neural representations, PtyINR performs end-to-end reconstruction directly from raw diffraction patterns without requiring any pre-characterization of the probe. Extensive evaluations demonstrate that PtyINR achieves superior reconstruction quality on both simulated and experimental data, with remarkable robustness under challenging low-signal conditions. Furthermore, PtyINR offers a generalizable, physics-informed framework for addressing probe-dependent inverse problems, making it applicable to a wide range of computational microscopy problems.

36 MATERIALS SCIENCE↗

Convective flow effects on protein crystal growth

A high-resolution microscopic interferometric setup for the monitoring of protein morphologies has been developed. Growth or dissolution of a crystal can be resolved with a long-term depth resolution of 200 A and a lateral resolution of 2 microns. This capability of simultaneously monitoring the interfacial displacement with high local depth resolution has yielded several novel results. We have found with lysozyme that (1) the normal growth rate is oscillatory, and (2) depending on the impurity content of the solution, the growth step density is either greater or lower at the periphery of a facet than in its center. The repartitioning of Na plus and Cl minus ions between lysozyme solutions and crystals was studied for a wide range of crystallization conditions. A nucleation-growth-repartitioning model was developed, to interpret the large body of data in unified way. The results strongly suggest that (1) the ion to lysozyne ratio in the crystal depends mostly on kinetic rather than crystallographic parameters, and (2) lysozyme crystals possess a salt-rich core with a diameter electron microscopy results appear to confirm this finding, which could have far-reaching consequences for x-ray diffraction studies. A computational model for diffusive-convective transport in protein crystallization has been applied to a realistic growth cell geometry, taking into account the findings of the above repartitioning studies and our kinetics data for the growth of lysozyme. The results show that even in the small cell employed, protein concentration nonuniformities and gravity-driven solutal convection can be significant. The calculated convection velocities are of the same order to magnitude as those found in earlier experiments. As expected, convective transport, i.e., at Og, lysozyme crystal growth remains kinetically limited. The salt distribution in the crystal is predicted to be non-uniform at both 1g and 0g, as a consequence of protein depletion in the solution. Static and dynamic light scattering studies in undersaturated and supersaturated solutions have been performed. Diffusivities in undersaturated solutions, were found to vary with lysozyme concentrations. Depending on the salt concentration, the diffusivities either increase or decrease. Interestingly, the corresponding static scattering intensities behave oppositely, Our current analysis indicates that these changes are inconsistent with aggregation in undersaturated solutions. However, the data are compatible with concentration-dependent changes of the interactions between protein and salt.

Rosenberger, Franz↗

Large scale crystallization of protein pharmaceuticals in microgravity via temperature change

The major objective of this research effort is the temperature driven growth of protein crystals in large batches in the microgravity environment of space. Pharmaceutical houses are developing protein products for patient care, for example, human insulin, human growth hormone, interferons, and tissue plasminogen activator or TPA, the clot buster for heart attack victims. Except for insulin, these are very high value products; they are extremely potent in small quantities and have a great value per gram of material. It is feasible that microgravity crystallization can be a cost recoverable, economically sound final processing step in their manufacture. Large scale protein crystal growth in microgravity has significant advantages from the basic science and the applied science standpoints. Crystal growth can proceed unhindered due to lack of surface effects. Dynamic control is possible and relatively easy. The method has the potential to yield large quantities of pure crystalline product. Crystallization is a time honored procedure for purifying organic materials and microgravity crystallization could be the final step to remove trace impurities from high value protein pharmaceuticals. In addition, microgravity grown crystals could be the final formulation for those medicines that need to be administered in a timed release fashion. Long lasting insulin, insulin lente, is such a product. Also crystalline protein pharmaceuticals are more stable for long-term storage. Temperature, as the initiation step, has certain advantages. Again, dynamic control of the crystallization process is possible and easy. A temperature step is non-invasive and is the most subtle way to control protein solubility and therefore crystallization. Seeding is not necessary. Changes in protein and precipitant concentrations and pH are not necessary. Finally, this method represents a new way to crystallize proteins in space that takes advantage of the unique microgravity environment. The results from two flights showed that the hardware performed perfectly, many crystals were produced, and they were much larger than their ground grown controls. Morphometric analysis was done on over 4,000 crystals to establish crystal size, size distribution, and relative size. Space grown crystals were remarkably larger than their earth grown counterparts and crystal size was a function of PCF volume. That size distribution for the space grown crystals was a function of PCF volume may indicate that ultimate size was a function of temperature gradient. Since the insulin protein concentration was very low, 0.4 mg/ml, the size distribution could also be following the total amount of protein in each of the PCF's. X-ray analysis showed that the bigger space grown insulin crystals diffracted to higher resolution than their ground grown controls. When the data were normalized for size, they still indicated that the space crystals were better than the ground crystals.

Long, Marianna M.↗

Dynamic compression effects of H 2 ⁡O in a dynamic diamond anvil cell: Origin of metastable ice VII and its crystal growth kinetics

We report on the structural verification of metastable ice VII solidifying in the phase space of ice VI at 1.80 GPa at room temperature. Using time-resolved (TR) x-ray diffraction and TR ruby luminescence paired with high-speed microphotography utilizing a dynamic diamond anvil cell, an initial compression rate range from 0.12 to 95.84 GPa/s was explored. The solidification pressure of metastable ice VII has a potential sigmoidal dependence upon compression rate with a turnover compression rate of ∼80 GPa/s. The preferred crystallization of ice VII in the stability field of ice VI is due to the increased nucleation rate of ice VII over ice VI at 1.77 GPa that is driven by the surface energy difference between the liquid and solid phases along with the change in Gibbs free energy of solidification. The dynamic pressure-volume–compression behaviors of ice phases (VI and VII) show a lattice stiffening in both phases, especially during the compression loading. It is also found that the compression rate greatly affects the solid-solid phase transition between ice VI and VII but does not affect the liquid-solid transition between water and ice VI as much. Lastly, a third phase transition was found to occur after metastable ice VII transforms into high-density amorphous (HDA) ice, which could be a disordered hydrogen-bonded network configuration of ice VII forming out of HDA ice facilitated by the decoupling of the oxygen movement and reorientation of the H 2⁡ O molecule. These results demonstrate the complexity of a seemingly simple molecule H 2⁡ O, how it can readily change its static properties with the modification of (de)compression rate, and highlight the need to use multiple TR structural and spectroscopic probes at higher time resolutions to realize the most comprehensive understanding.

Chemical bonding↗

Informed unsupervised machine learning analysis of dislocation microstructure from high-resolution differential aperture X-ray structural microscopy data

This study leverages high-resolution differential-aperture X-ray structural microscopy (DAXM) to probe the local dislocation structure in deformed 304L-stainless steel at small strain, by measuring the lattice rotation and deviatoric elastic strain with a sub-micron resolution. For a single grain in a polycrystalline specimen, the measured lattice rotation field over the measured volume exhibited a multimodal distribution while the deviatoric elastic strain showed a single-mode distribution. An unsupervised Cauchy mixture machine learning model was developed to resolve the multimodal distribution of the lattice rotation. By mapping the lattice rotation data associated with each Cauchy peak in the model back onto the measured volume, we identify contiguous regions of the crystal rotated near the average values corresponding to the peaks of the overall rotation distribution. These regions represent the grain subdivision in the microstructure. Finally, the dislocation density tensor was also computed and its norm was laid over the rotation field to detect the subgrain boundaries. This step provided a validation of the Cauchy mixture model for the analysis of the lattice rotation distribution. The current study highlights the integration of advanced X-ray microscopy techniques with data-driven analysis methods to uncover detailed microstructure scales in deformed crystals.

Machine learning; Lattice rotation; High-energy X-↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

A liquid radiation detector with high spatial resolution

Detector, using point anode, minimizes problem of oblique tracks by permitting construction of very thin counter. Detector is useful in cosmic ray and high energy physics research and X-ray and neutron diffraction technology.

Alvarez, L.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

High efficiency spectrographs for the EUV and soft X-rays

The use of grazing incidence optics and reflection grating designs is shown to be a method that improves the performance of spectrographs at wavelengths shorter than 1200 A. Emphasis is laid on spectroscopic designs for X ray and EUV astronomy, with sample designs for an objective reflection grating spectrograph (ORGS) and an echelle spectrograph for wavelengths longer than 100 A. Conical diffraction allows operations at grazing incidence in the echelle spectrograph. In ORGS, the extreme distance of X ray objects aids in collimating the source radiation, which encounters conical diffraction within the instrument, proceeds parallel to the optical axis, and arrives at the detector. A series of gratings is used to achieve the effect. A grazing echelle is employed for EUV observations, and offers a resolution of 20,000 over a 300 A bandpass.

Cash, W.↗