Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamline optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗

A versatile pressure-cell design for studying ultrafast molecular-dynamics in supercritical fluids using coherent multi-pulse x-ray scattering

Supercritical fluids (SCFs) can be found in a variety of environmental and industrial processes. They exhibit an anomalous thermodynamic behavior, which originates from their fluctuating heterogeneous micro-structure. Characterizing the dynamics of these fluids at high temperature and high pressure with nanometer spatial and picosecond temporal resolution has been very challenging. The advent of hard x-ray free electron lasers has enabled the development of novel multi-pulse ultrafast x-ray scattering techniques, such as x-ray photon correlation spectroscopy (XPCS) and x-ray pump x-ray probe (XPXP). These techniques offer new opportunities for resolving the ultrafast microscopic behavior in SCFs at unprecedented spatiotemporal resolution, unraveling the dynamics of their micro-structure. However, harnessing these capabilities requires a bespoke high-pressure and high-temperature sample system that is optimized to maximize signal intensity and address instrument-specific challenges, such as drift in beamline components, x-ray scattering background, and multi-x-ray-beam overlap. We present a pressure cell compatible with a wide range of SCFs with built-in optical access for XPCS and XPXP and discuss critical aspects of the pressure cell design, with a particular focus on the design optimization for XPCS.

47 OTHER INSTRUMENTATION↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-GeV FFA beam transport test at CEBAF

Jefferson National Lab plans an upgrade project to reach 22 GeV high polarization electron beam by using Fixed Field Alternating-gradient (FFA) magnets. The utilization of the FFA magnets for 10-22 GeV beam energy range is unexampled, therefore those magnets need an experimental validation before their full installation to form an arc in the Continuous Electron Beam Accelerator Facility (CEBAF). For this reason, JLAB is also considering the design of an FFA magnet test bench, i.e. a half or full FFA cell, that would be deployed in the current CEBAF in order to serve as the highest energy demonstration for the FFA field uniformity, permanent magnet resiliency with the beam as well as enabling beam optics measurements with the 5-11 GeV range highly polarized beams which closely resembles the full energy range of the 22 GeV upgrade. In this report, we present the status of the planned beamline for the FFA beam transport test at CEBAF.

Accelerator Physics↗

Phase Trombone Design in the Beam Transfer line for the Project PIP-II at Fermilab

PIP-II beam transfer line (BTL) to transport the beam from PIP-II Linac to the Booster ring at Fermilab. One crucial aspect of the BTL design involved the implementation of collimators. These collimators play a vital role in removing large amplitude particles from the beamline that might otherwise miss the horizontal and vertical edge of the foil at the point of the Booster injection. To ensure the effectiveness of these collimators, simulation was conducted to determine their optical placement within the BTL. The simulation revealed that the precise control of accumulated phase advances between the collimators and the foil was crucial. To achieve this control, a phase trombone is needed within the BTL. The phase trombone serves as an adjustment mechanism, allowing for the fine-tuning of the phase advance between the collimators and the foil, thus optimizing the performance of the collimation process. This paper discusses and presents the details of the design and implementation of the phase trombone within the PIP-II BTL.

43 PARTICLE ACCELERATORS↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Commissioning of the IOTA Proton Injector

The IOTA Proton Injector (IPI) at the Fermilab Accelerator Science and Technology facility (FAST) is a machine capable of delivering up to 14 mA pulses of protons at 2.5 MeV to the Integrable Optics Test Accelerator (IOTA) ring. Its construction was completed in the fall of 2025, followed by a successful commissioning run scheduled to conclude at the end of May 2026. It operates alongside the existing electron injector beamline to facilitate further beam physics research and continued development of novel accelerator technologies at the IOTA ring. This report details the current operational profile, known challenges, and future plans for the proton program development at FAST.

Romanov, A. [Fermilab] (ORCID:0000000287065709)↗

Simulations of coherent scattering experiments at storage ring synchrotron radiation sources in the hard x-ray range

Detailed simulations of experiments carried out at modern light sources are directly related to the most efficient and productive use of these facilities for research in multiple branches of science and technology. The “Synchrotron Radiation Workshop” computer code with its Python interface, and Sirepo web-browser-based graphical user interface, currently supports physical optics simulations of coherent X-ray scattering and imaging experiments on user-defined virtual samples. We present examples of simulations of coherent scattering experiments that are typically performed at the Coherent Hard X-ray beamline at Brookhaven National Laboratory’s (BNL) National Synchrotron Light Source II. We also present several comparisons of the simulations with the results of actual coherent X-ray scattering experiments with nano-fabricated test samples produced at BNL’s Center for Functional Nanomaterials.

36 MATERIALS SCIENCE↗

Lattice Design of the EIC Electron Storage Ring for Energies Down to 5 GeV

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory will feature an electron storage ring that will circulate polarized beams with energies up to 18 GeV. Recently a study has been undertaken to extend the minimum energy from 6 GeV to 5 GeV. As the solenoid-based spin rotators around the interaction point require specific bending angles that depend on the energy range, this change results in major changes to the geometry. Moreover, avoiding interference of the electron beamline with the other beamlines in the tunnel, as well as with the tunnel walls, is a formidable challenge, especially at the location of the large-diameter superconducting solenoids. In this contribution, the details of the modified spin rotators, geometrical layout, and optics of the revised lattice are presented.

43 PARTICLE ACCELERATORS↗

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature Control of Crystal Optics for Ultrahigh-Resolution Applications

The temperature control of crystal optics is critical for ultrahigh resolution applications such as those used in meV-resolved Inelastic Scattering. Due to the low count rate and long acquisition time of these experiments, for 1-meV energy resolution, the absolute temperature stability of the crystal optics must be maintained below 4 mK to ensure the required stability of lattice constant, thereby ensuring the energy stability of the optics. Furthermore, the temperature control with sub-mK precision enables setting the absolute temperature of individual crystal, making it possible to align the reflection energy of each crystal’s rocking curve in sub-meV resolution thereby maximizing the combined efficiency of the crystal optics. In this contribution, we report the details of an EPICS control system using PT1000 sensors, Keithley 3706A 7.5 digits sensor scanner, and Wiener MPOD LV power supply for the analyzer crystals of the Inelastic X-ray Scattering (IXS) beamline 10-ID at NSLS-II**. We were able to achieve absolute temperature stability below 1 mK and sub-meV energy alignment for several asymmetrically cut analyzer crystals. The EPICS ePID record was used for the control of the power supplies based on the PT1000 sensor input that was read with 7.5 digits accuracy from the Keithley 3706A scanner. The system enhances the performance of the meV-resolved IXS spectrometer with currently a 1.4 meV total energy resolution and unprecedented spectral sharpness for studies of atomic dynamics in a broad range of materials.

Gofron, Kaz↗

In situ observation of short- and long-timescale material property evolution under extreme conditions

Directly observing the evolution of material performance in-situ under extreme conditions remains a great challenge. Emergent behavior, such as the transition from incubation to steady state void swelling, is often difficult to capture in these conditions. To fill this gap, transient grating spectroscopy (TGS) has been used to collect multi-property information in-situ under high temperature exposure to ion beam irradiation. This all-optical method returns elastic and thermal transport properties with second-scale time resolution. Here, recent work using this methodology to track the evolution of Ni-based solid-solution alloys using the in situ ion irradiation TGS (I3TGS) beamline will be described. Tracking material property evolution during long exposure times (hours) provides a clear indication of when void swelling has occurred. On short timescales (seconds to minutes), observing rapid changes in thermoelastic properties as defect generation is initiated allows a unique window into bulk transient defect populations which are otherwise difficult to observe.

36 MATERIALS SCIENCE↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Analysis of the NGXO Telescope X-Ray Hartmann Data

Next Generation X-Ray Optics (NGXO) team at the Goddard Space Flight Center (GSFC) has been developing a new silicon-based grazing incidence mirror technology for future high resolution x-ray astronomical missions. Recently, the GSFC team completed the construction of first few mirror modules that contain one pair of mirrors. One of the mirror pairs was tested in GSFC 600-m long beamline facility and Panter (Neuried, Germay) 120-m long x-ray beamline facility. Both full aperture x-ray tests, Hartmann tests, and focal plane sweeps were completed. In this paper we present the data analysis process and compare the results from our models to measured x-ray centroid data, x-ray performance data, and out of focus images of the mirror pair.

Spaceborne telescopes↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

A mid-scale plasma-electrode Pockels cell for the FLUX laser

A mid-scale (270 x 270-mm aperture) plasma-electrode Pockels cell (PEPC) has been developed for the pump laser system in FLUX (the fourth-generation laser for ultrabroadband experiments). The FLUX mid-scale PEPC is adapted from the PEPC used in the OMEGA EP beamlines (410 x 410-mm aperture), with certain dimensions scaled to reduce capacitance while maintaining key plasma characteristics. After experimental optimization of operating parameters, particularly the plasma current, <70-ns switching time with excellent (>1000:1) contrast has been demonstrated. Dependence of optical switching performance on operating conditions is explained by a plasma model.

AMICA↗