At least 127 records · Page 7

A novel flow cell for optical particle analyzers—application to measurements of Malvern Insitec under high pressure and temperature

A flow cell is a necessary measurement interface for some important optical analyzers. In our application of the flow cell, we utilize a state-of-the-art optical analyzer (Malvern Insitec) to measure particle size distribution and concentration in-situ in a sampled flow from a novel pressurized oxygen-fuel combustion process. However, since this sampling flow is a flow of moist flue gas under high temperature and pressure, and the flow contains particles and corrosive acid gases, it is an extreme challenge to obtain a flow cell with a high optical quality that does not perturb the measurement. To address this challenge, we propose a new design for an optical flow cell. By using a unique flow field in the proposed flow cell, the measurement zone can be well defined by the sampling flow, minimizing the influence of purge flow. To demonstrate this flow cell, we have built a test system, and conduct measurements utilizing polydisperse-particle standards (10-100 µm and 1-10 µm). The results reveal that the optical windows are well protected by the purge flow field, without risk of deposition from the sampling flow, and the Malvern Insitec can measure the particle size distribution by using this flow cell, without generating sample bias.

Cheng, Mao↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

Isotope effects on the high pressure viscosity of liquid water measured by differential dynamic microscopy

In this paper, differential dynamic microscopy is performed in diamond anvil cells to measure the viscosity of water along the 24 °C isotherm to high-pressure by determination of the tracer diffusion coefficient of monodisperse silica spheres of known diameter and application of the Stokes-Einstein-Sutherland equation. This technique allows liquid samples to be compressed to greater pressure prior to freezing than with other viscometry methods. The highest-pressure measurement was made at 1.67 GPa, considerably deeper into the supercompressed regime than previously reported. The effect of isotopic composition is investigated with samples of normal water, heavy water, and partially deuterated water. When data below 0.25 GPa are excluded a free volume model fits the observed viscosities well yielding a theoretical glass transition density close to that observed in very-high-density amorphous ice. The improved fit above 0.25 GPa coincides with the loss of other anomalous behaviors in liquid water caused by hydrogen bonding and represents a transition to properties closer to those of a simple liquid.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermodynamic properties of Ca–Pb electrodes determined by electromotive force measurements

Thermodynamic properties of Ca–Pb alloys are investigated by electromotive force (emf) measurements to determine equilibrium cell potentials and phase properties for their application in energy storage systems such as liquid metal batteries. Using the electrochemical cell Ca(s) | CaF 2 (s) | Ca(in Pb) at 700–1060 K, cell emf is measured for thirteen Ca–Pb alloys at mole fractions, x Ca = 0.06–0.80. At 873 K, the equilibrium potentials of liquid Ca–Pb alloys are 0.57–0.62 V versus Ca and the activity values are as low as a Ca = 6.2 × 10 -8 at x Ca = 0.06. In addition, the emf values as a function of temperature provide partial molar quantities (entropy and enthalpy) as well as phase transitions which are corroborated by determining transition temperatures and phase constituents using differential scanning calorimetry (DSC) and powder X-ray diffraction (XRD). This study establishes the fundamental data necessary for the design of Pb-containing liquid metal electrodes through the integration of electrochemical, thermal, and structural properties of Ca–Pb electrodes.

25 ENERGY STORAGE↗

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy storage cell qualification and related systems, methods, and devices

Energy storage cell qualification and related systems, methods, and devices are disclosed. A method of qualifying rechargeable battery cells includes taking measurements on the rechargeable battery cells, determining specific capacity distributions of the rechargeable battery cells as a function of a number of discharge cycles based on the measurements, determining one or more specific capacity thresholds to separate the specific capacity distributions of the rechargeable battery cells into two or more classifications, and qualifying the rechargeable battery cells into the two or more classifications based, at least in part, on the specific capacity distributions and the one or more specific capacity thresholds. A method of implementing rechargeable battery cells into product manufacturing and qualifying the rechargeable battery cells, and deploying those of the rechargeable battery cells qualified into a first classification of the two or more classifications into the product.

Liaw, Boryann↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PV module spectral response measurements - Data and Resources

"This dataset includes spectral response curves for 12 commercial silicon module types that are deployed at SNL in Albuquerque. The modules chosen for evaluation were originally purchased by SNL for the PV Lifetime project (renamed to Systems Long-Term Evaluation [SLTE]). The majority of those modules are deployed outdoors for long-term evaluation, but several modules of each type were placed in storage for future comparison purposes. One stored module of each type was sent to NREL for the spectral response measurements. NREL used the recently developed Module Quantum Efficiency (QE) test bed. What makes this system unique is that it scans the entire module automatically, taking one or more measurements on each cell. Using the mean of these measurements at each wavelength leads to improvements in spectral mismatch correction and module power measurements but having the individual measurements also makes it possible to identify outlier cells, which could be useful for investigating underperforming modules. All measurements were performed nominally at 25°C"

14 SOLAR ENERGY↗

Electron and proton conductivity of Fe-N-C cathodes for PEM fuel cells: A model-based electrochemical impedance spectroscopy measurement

Impedance spectra of a PEM fuel cell with three Fe-N-C cathodes have been measured under the H 2 /N 2 testing regime. The spectra have been fitted using a recently developed physics-based impedance model, which takes into account finite proton ($σ_p$) and electron ($σ_e$) conductivity of the oxygen-free cathode catalyst layer. Fitting allowed to extract numerical data for $σ_p$, $σ_e$, the double layer capacitance, and the inductance of cables used for measuring impedance spectra. The values of σp and σe are close to what previously found for standard Pt/C electrodes, which is found for the first time using PGM-free catalysts. The method enables simultaneous measurement of reference proton and electron conductivity of PEMFC cathode.

25 ENERGY STORAGE↗

Controlling Interfacial Energetics and Charge Transfer Rates in 2D Semiconductors: Fundamental Studies en Route to Photoelectrochemical Energy Conversion Beyond the Shockley-Queisser Limit (Final Scientific/Technical Report)

Current photovoltaic and solar-to-fuel technologies do not fully utilize the energy of sunlight because excess photon energy above the semiconductor band gap is rapidly lost as heat through hot-carrier thermalization. Overcoming this loss mechanism is critical, as hot-carrier-based energy conversion systems are predicted to exceed the conventional efficiency limit of ~33%. This project advanced fundamental understanding of hot-carrier energy conversion in two-dimensional (2D) semiconductors, with a focus on monolayer MoS 2 . Using a combination of electrochemical microscopy and in situ ultrafast spectroscopic measurements, this research directly demonstrated hot-carrier extraction from monolayer MoS 2 photoelectrodes in proof-of-concept liquid junction solar cells. These measurements established that hot-carrier transfer can compete with ultrafast carrier cooling at solid–liquid interfaces, providing unambiguous experimental evidence that hot-carrier extraction is feasible in atomically thin semiconductors under operating photoelectrochemical conditions. Beyond demonstration, the project identified design rules for tuning hot-carrier extraction rates relative to cooling rates in 2D semiconductor photoelectrodes. The outcomes of this research provide foundational thermodynamic and kinetic insights for the rational design of next-generation hot-carrier-enabled solar energy conversion systems. These findings have broad implications for photoelectrochemical solar fuels production, electrocatalysis, and emerging energy conversion architectures that seek to harness nonequilibrium charge carriers for enhanced efficiency.

14 SOLAR ENERGY↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of rhenium as a function of pressure in a diamond anvil cell

We have measured the reflectance of rhenium in the visible region to pressures up to 100 GPa in a diamond anvil cell (DAC). By photographing the reflecting surface, we visually show that there are challenges to obtaining accurate values in a DAC for several reasons, including cupping of the diamonds and roughening of the surface with the increase in pressure. We propose some useful procedures, such as careful alignment of the incident light and using thin gaskets to minimize cupping of the diamonds as well as measurement in the central region of the diamond culet. We also show that knowledge of the reflectance of rhenium can overcome the problem of absorption of light by diamonds when studying the reflectance of materials at high pressure in a DAC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in mass spectrometry-enabled multiomics at single-cell resolution

We report biological organisms are multifaceted, intricate systems where slight perturbations can result in extensive changes in gene expression, protein abundance and/or activity, and metabolic flux. These changes occur at different timescales, spatially across cells of heterogeneous origins, and within single-cells. Hence, multimodal measurements at the smallest biological scales are necessary to capture dynamic changes in heterogeneous biological systems. Of the analytical techniques used to measure biomolecules, mass spectrometry (MS) has proven to be a powerful option due to its sensitivity, robustness, and flexibility with regard to the breadth of biomolecules that can be analyzed. Recently, many studies have coupled MS to other analytical techniques with the goal of measuring multiple modalities from the same single-cell. It is with these concepts in mind that we focus this review on MS-enabled multiomic measurements at single-cell or near-single- cell resolution.

47 OTHER INSTRUMENTATION↗

A New Analytical Expression for Estimating the Adiabatic Temperature Rise in Lithium-Ion Batteries During High-Power Pulses

A coupled, thermal-electrochemical model is used to explain why the Joule heating assumption (i.e., I 2 R) does not provide a good representation of the temperature rise during high power pulses in lithium-ion batteries, even in cases where the reversible heat generation can be neglected. The poor agreement occurs because the internal resistance changes during the pulse due to the opposing effects of mass transport in the electrolyte, which raises the resistance, and heat generation (temperature rise), which lowers the resistance. These insights are used to propose a new analytical expression for predicting the temperature rise during adiabatic pulses with limited experimental and physical data. The expression accounts for thermal effects using a Taylor series expansion of an Arrhenius-type equation. It accounts for transport effects using an approximate solution to the one-dimensional diffusion equation. The new expression is shown to accurately estimate the simulated, adiabatic temperature rise across a range of loadings (1 to 4 mAh cm -2 ) and C-rates (1C to 10C) for cells containing LiNi 0.5 Mn 0.3 Co 0.2 O 2 positive electrodes and graphite negative electrodes. In conclusion, it is also shown to accurately estimate the experimental, adiabatic temperature rise measured for cells with LiFePO 4 positive electrodes and mesocarbon negative electrodes with minimal changes to the fitted parameters.

25 ENERGY STORAGE↗

Implications of Electron Transport Layer and Back Metal Contact Variations in Tin–Lead Perovskite Solar Cells Assessed by Spectroscopic Ellipsometry and External Quantum Efficiency

The structural and optical properties of hybrid organic–inorganic metal halide perovskite solar cells are measured by spectroscopic ellipsometry to reveal an optically distinct interfacial layer among the back contact metal, charge transport, and absorber layers. Understanding how this interfacial layer impacts performance is essential for developing higher performing solar cells. Here, this interfacial layer is modeled by Bruggeman effective medium approximations (EMAs) to contain perovskite, C 60 , BCP, and metal. External quantum efficiency (EQE) simulations that consider scattering, electronic losses, and the formation of nonparallel interfaces are created with input derived from ellipsometry structural-optical models and compared with experimental EQE to estimate optical losses. This nonplanar interface causes optical losses in short circuit current density (JSC) of up to 1.2 mA cm –2 . A study of glass/C 60 /SnO 2 /Ag or Cu and glass/C 60 /BCP/Ag film stacks shows that C 60 and BCP mix, but replacing BCP with SnO 2 can prevent mixing between the ETLs to prevent contact between C 60 and back contact metal and enable the formation of a planar interface between ETLs and back contact metals.

14 SOLAR ENERGY↗

Characterization of the pressure coefficient of manganin and temperature evolution of pressure in piston-cylinder cells

Here, we report measurements of the temperature- and pressure-dependent resistance, R ( T , p ), of a manganin manometer in a 4 He-gas pressure setup from room temperature down to the solidification temperature of 4 He ( T solid ~ 50 K at 0.8 GPa) for pressures, p , between 0 GPa and ~0.8 GPa. The same manganin wire manometer was also measured in a piston-cylinder cell (PCC) from 300 K down to 1.8 K and for pressures between 0 GPa and ~2 GPa. From these data, we infer the temperature and pressure dependence of the pressure coefficient of manganin, α ( T , p ), defined by the equation R p = (1 + αp ) R 0 , where R 0 and R p are the resistances of manganin at ambient pressure and finite pressure, respectively. Our results indicate that upon cooling, α first decreases, then goes through a broad minimum at ~120 K, and increases again toward lower temperatures. In addition, we find that α is almost pressure-independent at T ≳ 60 K up to p ~ 2 GPa, but shows a pronounced p dependence at T ≲ 60 K. Using this manganin manometer, we demonstrate that p overall decreases with decreasing temperature in the PCC for the full pressure range and that the size of the pressure difference between room temperature and low temperatures ( T = 1.8 K), Δ p , decreases with increasing pressure. We also compare the pressure values inferred from the manganin manometer with the low-temperature pressure, determined from the superconducting transition temperature of elemental lead (Pb). As a result of these data and analysis, we propose a practical algorithm to infer the evolution of pressure with temperature in a PCC.

47 OTHER INSTRUMENTATION↗

Automated Bacterial Identification and Morphological Feature Analysis in Low‐Dose Cryo‐EM Using YOLOv11

Bacteria rapidly adapt to environmental cues through morphological and ultrastructural changes that correlate with physiology and behavior. Cryogenic transmission electron microscopy (cryo‐TEM) can capture these phenotypic changes in near‐native, vitrified states, but manual analysis of low‐dose micrographs is labor intensive and limits throughput. Here, we present an end‐to‐end workflow that combines low‐dose cryo‐TEM imaging with a YOLOv11‐based instance‐segmentation model to automatically identify bacteria and quantify key structural features directly from the micrographs. This workflow enables (i) robust bacterial localization and counting from low‐magnification atlas/montage images, (ii) automated measurements of cell‐envelope (outer–inner membrane) thickness and anisotropy from higher‐magnification views, and (iii) detection and quantification of bacteria–flagella interactions, including overlap length and curvature metrics for interacting versus noninteracting flagella. Using Pantoea sp. YR343 grown under distinct media conditions, we show that the automated measurements agree with manual annotations while substantially reducing analysis time. Together, these tools provide a practical framework for scalable bacterial identification and quantitative phenotyping in low‐dose cryo‐TEM datasets and establish a foundation for extending cryo‐TEM image analysis toward higher‐throughput studies of microbial heterogeneity and biointerfaces.

YOLOv11↗