Search NASA⌕ Search

SEARCH · Search NASA

Results for “mask parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Designer Metasurfaces for Antireflective Applications Enabled by Advanced Nanoparticle Technology

Optic processing advances have shifted system limitations, with current constraints consisting of antireflective (AR) coatings applied to optics and the inability to reduce size, weight, and price. Metasurfaces, and more broadly metaoptics, provide an avenue to overcome these limitations. The ability to generate substrate-engraved metasurfaces that can be tailored is demonstrated within a broad design space to satisfy large-area AR applications for bandpass or broadband needs, demonstrating an optically equivalent surface roughness standard deviation of only 5 Å. Using an advanced nanoparticle masking approach, two metasurfaces are fabricated: 1) vertical sidewall nanofeature metasurface (MS) for AR applications at 351 nm, and 2) sloped sidewall MS designed for broadband AR applications. For the 351 nm MS, the reflectance is measured to be 0.127%. In the case of the sloped sidewall MS, the reflectance is measured to be <0.25% over 400–700 nm and <1% over 400–1100 nm. To the best of the authors’ knowledge, this is the first demonstration of a broadband AR capable of this performance. The tunability of these structures, with a parameter space spanning even more remarkable designs such as broader bands and acceptance angles, coupled with high laser-induced damage durability and mechanical robustness, displays the strength of metasurfaces for AR applications.

36 MATERIALS SCIENCE↗

Reviving sub-keV warm dark matter: a UVLF-based analysis

Thermal warm dark matter (WDM) particles with m WDM ≤ 1 keV are ruled out at more than 4σ by multiple observational probes, owing to the strong suppression of small-scale structure induced by early-time free-streaming. Recently, it was highlighted that a small admixture of ∼ 1% (f CDM ∼ 0.01) cold dark matter (CDM) endowed with a blue-tilted isocurvature spectrum could offset the WDM-induced suppression and relax the WDM mass bound by a factor of 𝒪(10). If viable, this “warm + cold-isocurvature” scenario would allow sub-keV WDM particles to constitute nearly the full dark matter abundance while potentially alleviating some small-scale tensions. In this work, we test this mechanism by constraining the WDM mass mWDM while marginalizing over CDM isocurvature parameters. We combine ultraviolet luminosity function measurements from the Hubble Space Telescope and James Webb Space Telescope over redshift 4 ≤ z ≤ 11 with CMB, BAO, and SNe data. For a pure WDM model, our joint analysis yields a lower bound m WDM > 1.8 keV (95% credible intervals). When CDM isocurvature is introduced at f CDM = 0.01, the limit relaxes to m WDM > 0.27 keV (95% credible intervals), reflecting a shallow degeneracy in which blue-tilted isocurvature fluctuations partially compensate for WDM suppression. These results provide new constraints on thermal WDM in the presence of CDM isocurvature fluctuations and quantify the extent to which such fluctuations can mask the small-scale signatures of light relics.

cosmological parameters from CMBR↗

Monitoring Digital Closed-Loop Feedback Systems

A technique of monitoring digital closed-loop feedback systems has been conceived. The basic idea is to obtain information on the performances of closed-loop feedback circuits in such systems to aid in the determination of the functionality and integrity of the circuits and of performance margins. The need for this technique arises as follows: Some modern digital systems include feedback circuits that enable other circuits to perform with precision and are tolerant of changes in environment and the device s parameters. For example, in a precision timing circuit, it is desirable to make the circuit insensitive to variability as a result of the manufacture of circuit components and to the effects of temperature, voltage, radiation, and aging. However, such a design can also result in masking the indications of damaged and/or deteriorating components. The present technique incorporates test circuitry and associated engineering-telemetry circuitry into an embedded system to monitor the closed-loop feedback circuits, using spare gates that are often available in field programmable gate arrays (FPGAs). This technique enables a test engineer to determine the amount of performance margin in the system, detect out of family circuit performance, and determine one or more trend(s) in the performance of the system. In one system to which the technique has been applied, an ultra-stable oscillator is used as a reference for internal adjustment of 12 time-to-digital converters (TDCs). The feedback circuit produces a pulse-width-modulated signal that is fed as a control input into an amplifier, which controls the circuit s operating voltage. If the circuit s gates are determined to be operating too slowly or rapidly when their timing is compared with that of the reference signal, then the pulse width increases or decreases, respectively, thereby commanding the amplifier to increase or reduce, respectively, its output level, and "adjust" the speed of the circuits. The nominal frequency of the TDC s pulse width modulated outputs is approximately 40 kHz. In this system, the technique is implemented by means of a monitoring circuit that includes a 20-MHz sampling circuit and a 24-bit accumulator with a gate time of 10 ms. The monitoring circuit measures the duty cycle of each of the 12 TDCs at a repetition rate of 28 Hz. The accumulator content is reset to all zeroes at the beginning of each measurement period and is then incremented or decremented based of the value of the state of the pulse width modulated signal. Positive or negative values in the accumulator correspond to duty cycles greater or less, respectively, than 50 percent.

Katz, Richard↗

Differences in Pre and Post Vascular Patterning Within Retinas from ISS Crew Members and Head-Down Tilt (HDT) Subjects by VESGEN Analysis

Accelerated research by NASA has investigated the significant risks incurred during long-duration missions in microgravity for Space Flight-Associated Neuro-ocular Syndrome (SANS, formerly known as Visual Impairments associated with Increased Intracranial Pressure, VIIP) [1]. For our study, NASA's VESsel GENeration Analysis (VESGEN) was used to investigate the role of retinal blood vessels in the etiology of SANS/VIIP. The response of retinal vessels to microgravity was evaluated in astronaut crew members pre and post flight to the International Space Station (ISS), and compared to the response of retinal vessels in healthy volunteers to 6deg head-down tilt during 70 days of bed rest (HDTBR). For the study, we are testing the hypothesis that long-term cephalad fluid shifts resulting in ocular and visual impairments are necessarily mediated in part by retinal blood vessels, and therefore are accompanied by structural adaptations of the vessels. METHODS: Vascular patterns in the retinas of crew members and HDTBR subjects extracted from 30deg infrared (IR) Heidelberg Spectralis images collected pre/postflight and pre/post HDTBR, respectively, were analyzed by VESGEN (patent pending). VESGEN is a mature, automated software developed as a research discovery tool for progressive vascular diseases in the retina and other tissues. The multi-parametric VESGEN analysis generates maps of branching arterial and venous trees quantified by parameters such as the fractal dimension (Df, a modern measure of vascular space-filling capacity), vessel diameters, and densities of vessel length and number classified into specific branching generations according to vascular physiological branching rules. The retrospective study approved by NASA's Institutional Review Board included the analysis of bilateral retinas in eight ISS crew members monitored by routine occupational surveillance and six HDTBR subjects (NASA FARU Campaign 11, for example). The VESGEN analysis was conducted in a blinded fashion, with IR retinal images masked to the subject's identity, ophthalmic and clinical characteristics, and to the temporal sequence of image collection. To complete our study, VESGEN results will be analyzed statistically and correlated with other ophthalmic and medical findings. RESULTS: Preliminary results for changes in the pre to post status of vascular patterning in the retinas of crew members and HDTBR subjects are interestingly opposite. By Df and other vascular branching measures, the space-filling capacity of arterial and venous trees decreased in the majority of crew members (11/16 retinas). In contrast, vascular densities increased in HDTBR subjects by the same parameters (6/10 retinas). To conclude the study, biostatistics and medical analyses will be conducted to quantify and draw conclusions about how the changes associated with flight compare to those associated with HDTBR. CONCLUSIONS: Vascular densities appeared to decrease in the retinas of ISS crew members and increase in HDTBR subjects. Differences in arterial and venous response to cephalad fluid shifts induced by ISS and HDTBR may have resulted from a long-duration conditioning phenomenon (for example, 6-month ISS missions compared to 70 days HDTBR), or the presence of gravity in HDTBR compared to microgravity on the ISS. In addition, increased and decreased vessel diameters for Crew Members and HDTBR, respectively, are subject to limits of im

Vascular↗

Atmospheric Correction at AERONET Locations: A New Science and Validation Data Set

This paper describes an AERONET-based Surface Reflectance Validation Network (ASRVN) and its dataset of spectral surface bidirectional reflectance and albedo based on MODIS TERRA and AQUA data. The ASRVN is an operational data collection and processing system. It receives 50x50 square kilometer subsets of MODIS L1B data from MODAPS and AERONET aerosol and water vapor information. Then it performs an accurate atmospheric correction for about 100 AERONET sites based on accurate radiative transfer theory with high quality control of the input data. The ASRVN processing software consists of L1B data gridding algorithm, a new cloud mask algorithm based on a time series analysis, and an atmospheric correction algorithm. The atmospheric correction is achieved by fitting the MODIS top of atmosphere measurements, accumulated for 16-day interval, with theoretical reflectance parameterized in terms of coefficients of the LSRT BRF model. The ASRVN takes several steps to ensure high quality of results: 1) cloud mask algorithm filters opaque clouds; 2) an aerosol filter has been developed to filter residual semi-transparent and sub-pixel clouds, as well as cases with high inhomogeneity of aerosols in the processing area; 3) imposing requirement of consistency of the new solution with previously retrieved BRF and albedo; 4) rapid adjustment of the 16-day retrieval to the surface changes using the last day of measurements; and 5) development of seasonal back-up spectral BRF database to increase data coverage. The ASRVN provides a gapless or near-gapless coverage for the processing area. The gaps, caused by clouds, are filled most naturally with the latest solution for a given pixels. The ASRVN products include three parameters of LSRT model (k(sup L), k(sup G), k(sup V)), surface albedo, NBRF (a normalized BRF computed for a standard viewing geometry, VZA=0 deg., SZA=45 deg.), and IBRF (instantaneous, or one angle, BRF value derived from the last day of MODIS measurement for specific viewing geometry) for MODIS 500m bands 1-7. The results are produced daily at resolution of 1 km in gridded format. We also provide cloud mask, quality flag and a browse bitmap image. The new dataset can be used for a wide range of applications including validation analysis and science research.

Wang, Yujie↗

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Improved Phase-Mask Fabrication of Fiber Bragg Gratings

An improved method of fabrication of Bragg gratings in optical fibers combines the best features of two prior methods: one that involves the use of a phase mask and one that involves interference between the two coherent laser beams. The improved method affords flexibility for tailoring Bragg wavelengths and bandwidths over wide ranges. A Bragg grating in an optical fiber is a periodic longitudinal variation in the index of refraction of the fiber core. The spatial period (Bragg wavelength) is chosen to obtain enhanced reflection of light of a given wavelength that would otherwise propagate relatively unimpeded along the core. Optionally, the spatial period of the index modulation can be made to vary gradually along the grating (such a grating is said to be chirped ) in order to obtain enhanced reflection across a wavelength band, the width of which is determined by the difference between the maximum and minimum Bragg wavelengths. In the present method as in both prior methods, a Bragg grating is formed by exposing an optical fiber to an ultraviolet-light interference field. The Bragg grating coincides with the pattern of exposure of the fiber core to ultraviolet light; in other words, the Bragg grating coincides with the interference fringes. Hence, the problem of tailoring the Bragg wavelength and bandwidth is largely one of tailoring the interference pattern and the placement of the fiber in the interference pattern. In the prior two-beam interferometric method, a single laser beam is split into two beams, which are subsequently recombined to produce an interference pattern at the location of an optical fiber. In the prior phase-mask method, a phase mask is used to diffract a laser beam mainly into two first orders, the interference between which creates the pattern to which an optical fiber is exposed. The prior two-beam interferometric method offers the advantage that the period of the interference pattern can be adjusted to produce gratings over a wide range of Bragg wavelengths, but offers the disadvantage that success depends on precise alignment and high mechanical stability. The prior phase-mask method affords the advantages of compactness of equipment and relative insensitivity to both misalignment and vibration, but does not afford adjustability of the Bragg wavelength. The present method affords both the flexibility of the prior two-beam interferometric method and the compactness and stability of the prior phase-mask method. In this method (see figure), a laser beam propagating along the x axis is normally incident on a phase mask that lies in the (y,z) plane. The phase of light propagating through the mask is modulated with a spatial periodicity, p, along the y axis chosen to diffract the laser light primarily to first order at the angle . (The zero-order laser light propagating along the x axis can be used for alignment and thereafter suppressed during exposure of the fiber.) The diffracted light passes through a concave cylindrical lens, which converts the flat diffracted wave fronts to cylindrical ones, as though the light emanated from a line source. Then two parallel flat mirrors recombine the diffracted beams to form an interference field equivalent to that of two coherent line sources at positions A and B (virtual sources). The interference pattern is a known function of the parameters of the apparatus and of position (x,y) in the interference field. Hence, the tilt, wavelength, and chirp of the Bragg grating can be chosen through suitable adjustments of the apparatus and/or of the position and orientation of the optical fiber. In particular, the Bragg wavelength can be adjusted by moving the fiber along the x axis, and the bandwidth can be modified over a wide range by changing the fiber tilt angle or by moving the phase mask and/or the fiber. Alignment is easy because the zero-order beam defines the x axis. The interference is relatively stable and insensitive to the mechanical vibration because of the gh symmetry and compactness of the apparatus, the fixed positions of the mirrors and lens, and the consequent fixed positions of the two virtual line sources, which are independent of the translations of the phase mask and the laser relative to the lens.

Grant, Joseph↗

Fabrication of model ultrafiltration membranes with uniform, high aspect ratio pores

Here, in this manuscript, we report the facile fabrication of large-area model membranes with highly uniform and high aspect ratio pores with diameters <20 nm. These membranes are useful for fundamental investigations of separation by size exclusion in the ultrafiltration regime, where species to be separated from solution have dimensions of 1–100 nm. Such investigations require membranes with narrow pores and high aspect ratios such that the Hagen–Poiseuille equation is followed, enabling well-known models such as the hindered transport model to be evaluated and other affecting factors to be ignored. We demonstrate that the sub-20 nm pores in the membrane are of sufficiently high aspect ratio such that water flux through the membrane is consistent with the Hagen–Poiseuille equation. The fabrication relies on self-assembling block copolymers to form uniform, densely packed patterns with sub-20 nm resolution, sequential infiltration synthesis to convert the block copolymer in situ into a mask with adequate contrast to etch pores with an aspect ratio >5, and low-resolution photolithography to transfer the pattern over a large area into a silicon nitride membrane. Model membranes with narrow pore-size distribution fabricated in this way provide the means to investigate parameters that impact size-selective ultrafiltration separations such as the relationships between solute or particle size and pore size, their distributions, and rejection profiles, and, therefore, test the validity or limits of separation models.

Chen, Wen↗

Octofitter: Fast, Flexible, and Accurate Orbit Modeling to Detect Exoplanets

As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images can be freely combined with the radial velocity and proper motion anomaly, even without a confirmed detection in any single epoch. In this paper, we present a fast and differentiable multimethod orbit-modeling and planet detection code called Octofitter. This code is designed to be highly modular and allows users to easily adjust priors, change parameterizations, and specify arbitrary function relations between the parameters of one or more planets. Octofitter further supplies tools for examining model outputs including prior and posterior predictive checks and simulation-based calibration. We demonstrate the capabilities of Octofitter on real and simulated data from different instruments and methods, including HD 91312, simulated JWST/NIRISS aperture masking interferometry observations, radial velocity curves, and grids of images from the Gemini Planet Imager. We show that Octofitter can reliably recover faint planets in long sequences of images with arbitrary orbital motion. This publicly available tool will enable the broad application of multiepoch and multimethod exoplanet detection, which could improve how future targeted ground- and space-based surveys are performed. Finally, its rapid convergence makes it a useful addition to the existing ecosystem of tools for modeling the orbits of directly imaged planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-sensor Cloud Retrieval Simulator and Remote Sensing from Model Parameters : Synthetic Sensor Radiance Formulation - Pt. 1

In this paper we describe a general procedure for calculating synthetic sensor radiances from variable output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint, the algorithm takes explicit account of the model subgrid variability, in particular its description of the probability density function of total water (vapor and cloud condensate.) The simulated sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies.We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products). We focus on clouds because they are very important to model development and improvement.

Simulations↗

The development and application of the stirred‐reactor coupon analysis (SRCA) test method

A new technique, termed the stirred‐reactor coupon analysis (SRCA) method, has been developed to measure the rate of glass dissolution in forward‐rate conditions. Monolithic glass coupons are partially masked with an inert material before placement in a large volume of well‐mixed solution with known chemistry and temperature for a predetermined duration. After the test, the mask is removed, and the difference in step height between the protected area and the exposed corroded portions of the sample coupon is measured to determine the extent of glass dissolution. The step height is converted to a rate measurement using the test duration and glass density. Test parameters such as sample surface preparation and test duration were evaluated to determine their effects on the measured rates. Additionally, results from an interlaboratory study (ILS) consisting of 12 laboratories from 11 different institutions are presented, where each laboratory performed 12 independent tests. When removing experimental outlier data, the 95% reproducibility limits for the SRCA method has no statistical difference with previously published standardized test methods used to determine the forward rate of glass dissolution. Overall, this paper describes steps necessary to perform the test method and provides the statistical calculations to evaluate test accuracy.

chemical durability↗

Software reliability through fault-avoidance and fault-tolerance

The use of back-to-back, or comparison, testing for regression test or porting is examined. The efficiency and the cost of the strategy is compared with manual and table-driven single version testing. Some of the key parameters that influence the efficiency and the cost of the approach are the failure identification effort during single version program testing, the extent of implemented changes, the nature of the regression test data (e.g., random), and the nature of the inter-version failure correlation and fault-masking. The advantages and disadvantages of the technique are discussed, together with some suggestions concerning its practical use.

Vouk, Mladen A.↗

Materials Processing in Space: Model Experiments aboard the International Space Station

Direct observation of fluid flow, bubble movement and solidification during controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus in the glovebox facility (GBX) on board the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. Real time visualization of the controlled directional melt back and resolidification reveals a number of microgravity dependent phenomena otherwise masked by Earth s gravity. These and some initial analysis of the observed events is presented.

Grugel, Richard↗

Equivalent Sensor Radiance Generation and Remote Sensing from Model Parameters: Equivalent Sensor Radiance Formulation - Part 1

In this paper we describe a general procedure for calculating equivalent sensor radiances from variables output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint the algorithm takes explicit account of the model subgrid variability, in particular its description of the probably density function of total water (vapor and cloud condensate.) The equivalent sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies. We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products.) We focus on clouds and cloud/aerosol interactions, because they are very important to model development and improvement.

Simulations↗

ARM Data as A Resource for Validation of NASA PACE Cloud Retrievals

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission will launch in January 2024 and continue and improve upon satellite data records in its eponymous domains. PACE will carry a broad-swath hyperspectral imager, OCI, which will provide MODIS/VIIRS-type cloud data products (i.e. a cloud mask, top height, visible optical thickness, droplet effective radius, phase, and derived water path). It will also carry two multi-angle polarimeters (HARP2 and SPEXone) which will not only provide the above but also enable retrievals of additional cloud properties (e.g. droplet effective variance, ice crystal asymmetry parameter). Validating satellite-based cloud retrievals is challenging. We plan to use several ARM data streams to evaluate PACE cloud data products and are prototyping our analyses using retrievals from MODIS on the Aqua satellite and OLCI on the Sentinel-3A satellite. This poster shows how we plan to use ARM data to evaluate liquid water path (via MWRRET) and cloud top height retrievals (via KARZASRCL), with example results from these proxy sensors and ARM data from the SGP, ENA, and NSA sites. We seek comments from and collaborations with the ARM community to get the most out of our respective data streams.

ARM↗

Radar-Enabled Recovery of the Sutters Mill Meteorite, a Carbonaceous Chondrite Regolith Breccia

Doppler weather radar imaging enabled the rapid recovery of the Sutter's Mill meteorite after a rare 4-kiloton of TNT-equivalent asteroid impact over the foothills of the Sierra Nevada in northern California. The recovered meteorites survived a record high-speed entry of 28.6 kilometers per second from an orbit close to that of Jupiter-family comets (Tisserand's parameter = 2.8 +/- 0.3). Sutter's Mill is a regolith breccia composed of CM (Mighei)-type carbonaceous chondrite and highly reduced xenolithic materials. It exhibits considerable diversity of mineralogy, petrography, and isotope and organic chemistry, resulting from a complex formation history of the parent body surface. That diversity is quickly masked by alteration once in the terrestrial environment but will need to be considered when samples returned by missions to C-class asteroids are interpreted.

Radar↗