Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Attitude-referenced radiometer study. Part 2: Primary calibration system

A primary calibration system, PCS, for infrared radiometers has been developed, built, and tested. The system allows radiometers to be calibrated with less than 1 percent error for use in earth coverage horizon measurements, earth resources surveys, and synoptic meteorological measurement. The final design, fabrication and test of the PCS are reported. A detailed description of the PCS construction is presented, along with the results of a complete series of functional tests. Test to verify the source thermal characteristics, collimator reflectance, and output beam characteristics are described and their results presented.

Williamson, W. R.↗

Electronically Steered Thinned Array Radiometer (ESTAR) system design, calibration, and sensitivity

The ESTAR system, an imaging L-band radiometer designed to provide measurements of soil moisture from space, is described. The large aperture size dictated by the resolution requirement (10 km or less) suggests the use of aperture synthesis, and plans to have ESTAR operate in low earth orbit require that the synthesis be performed in the short data acquisition time permitted by satellite motion. Two forms of ESTAR are described. ESTAR-0 is to be an airborne prototype designed for proof of concept; it will image a line of eight adjacent pixels with 8 degree spatial resolution of 0.1 degree Kelvin temperature resolution, given 1 sec integration time. ESTAR-1 is the satellite version to operate from space. A tentative sensor design will image a line of 128 0.5 degree pixels with 2.0 degree K resolution assuming 0.7 sec integration at 700 km altitude.

Ruf, C.↗

Performance evaluation of the solar backscatter ultraviolet radiometer, model 2 (SBUV/2) inflight calibration system

The Solar Backscatter Ultraviolet Radiometer, Model 2 (SBUV/2) instruments, as part of their regular operation, deploy ground aluminum reflective diffusers to deflect solar irradiance into the instrument's field-of-view. Previous SBUV instrument diffusers have shown a tendency to degrade in their reflective efficiencies. This degradation will add a trend to the ozone measurements if left uncorrected. An extensive in-flight calibration system was designed into the SBUV/2 instruments to effectively measure the degradation of the solar diffuser (Ball Aerospace Systems Division 1981). Soon after launch, the NOAA-9 SBUV/2 calibration system was unable to track the diffuser's reflectivity changes due, in part, to design flows (Frederick et al. 1986). Subsequently, the NOAA-11 SBUV/2 calibration system was redesigned and an analysis of the first 2 years of data (Weiss et al. 1991) indicated the NOAA-11 SBUV/2 onboard calibration system's performance to be exceeding preflight expectations. This paper will describe the analysis of the first three years NOAA-11 SBUV/2 calibration system data.

Weiss, H.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

Effect of nonideal square-law detection on static calibration in noise-injection radiometers

The effect of nonideal square-law detection on the static calibration for a class of Dicke radiometers is examined. It is shown that fourth-order curvature in the detection characteristic adds a nonlinear term to the linear calibration relationship normally ascribed to noise-injection, balanced Dicke radiometers. The minimum error, based on an optimum straight-line fit to the calibration curve, is derived in terms of the power series coefficients describing the input-output characteristics of the detector. These coefficients can be determined by simple measurements, and detection nonlinearity is, therefore, quantitatively related to radiometric measurement error.

Hearn, C. P.↗

Inter-calibrating Brightness Temperatures of a Constellation of Radiometers

In 2010, the National Aeronautics and Space Agency (NASA) of the U.S.A. and the Japanese Exploration Agency (JAXA) of Japan in cooperation with other U.S. and international partners will launch the Global Precipitation Measurement (GPM) mission. The mission center-piece is a core U.S. provided satellite holding a scanning microwave imager provided by the U.S. A. and a dual-frequency precipitation radar provided by Japan. The core satellite is in a 65 deg inclination (the current Tropical Rainfall Measuring Mission -TRMM is in a 35 deg inclination). Joining the core satellite are a constellation of approximately 8 satellites containing scanning radiometers. The purpose of the constellation is to increase the global sampling capability of the mission. One constellation satellite will be provided by NASA. Some of the constellation radiometers will provided by other U.S. agencies with existing (e.g. SSMI/S) or planned (NPOESS) radiometer assets. International groups have also expressed interest in contributing to the GPM mission including providing radiometer data for the GPM constellation. The use of a heterogeneous group of scanning radiometers each with its own unique purpose, characteristics and calibration offers a significant challenge for combining brightness temperatures or rain retrievals to create meaningful combined global radiometer products. However, the availability of active dual precipitation radar on the GPM core in combination with a well-calibrated radiometer on the same platform offers the possibility of inter-calibrating the constellation radiometers using the core satellite as a calibrator. This paper describes a joint NASA/GSFC and Colorado State University prototype effort at inter-calibrating existing radiometers using such a core calibrator approach. In the prototype, existing radiometers (i.e. SSM/I and AMSR-E) are intercalibrated, as required, using the TRMM Precipitation Radar (PR) and TRMM Microwave Imager (TMI) as the calibration core. This prototype includes four basic steps: provide the data in a normalized-common logical radiometer format, convert all data to a granule that stops and starts at the southernmost latitude rather than at the equator, perform basic processing and finally inter-calibrate the radiometers with the TRMM core as appropriate. Basic processing includes quality control, cross-track bias correction as well as the core action of converting T(sub a), to T(sub b). The purpose of the inter-calibration step is to provide consistent brightness temperatures for the various SSMA sensors, TMI and AMSR-E. The C appended to the level of the product indicates common brightness temperature (T(sub c)). The paper provides a summary of each of these actions. The details of the processing as well as data format and tools can be obtained by connecting to the website at mrain.atmos.colostate.eduLEVEL1C .

Stocker, Erich Franz↗

Calibration target for temperature radiometer

Technique measures temperature/voltage drop characteristics of very thin filament. With constant current running through filament, voltage drop is recorded at various temperatures, as measured by calibrated thermocouple.

Edwards, S. F.↗

Heat Capacity Mapping Radiometer (HCMR) data processing algorithm, calibration, and flight performance evaluation

The rationale and procedures used in the radiometric calibration and correction of Heat Capacity Mapping Mission (HCMM) data are presented. Instrument-level testing and calibration of the Heat Capacity Mapping Radiometer (HCMR) were performed by the sensor contractor ITT Aerospace/Optical Division. The principal results are included. From the instrumental characteristics and calibration data obtained during ITT acceptance tests, an algorithm for post-launch processing was developed. Integrated spacecraft-level sensor calibration was performed at Goddard Space Flight Center (GSFC) approximately two months before launch. This calibration provided an opportunity to validate the data calibration algorithm. Instrumental parameters and results of the validation are presented and the performances of the instrument and the data system after launch are examined with respect to the radiometric results. Anomalies and their consequences are discussed. Flight data indicates a loss in sensor sensitivity with time. The loss was shown to be recoverable by an outgassing procedure performed approximately 65 days after the infrared channel was turned on. It is planned to repeat this procedure periodically.

Bohse, J. R.↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 ?m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Characterization of Clouds and the Anisotropy of Emitted and Reflected Radiances for the Purpose of Obtaining the Radiative Heating of the Atmosphere

The goal of the work supported through this grant was to assess the validity of the assumptions underlying the CERES Strategy for determining radiative fluxes. Specifically, the work focused on the determination of scene type and the use of anisotropic factors to derive radiative fluxes from observed broadband radiances. The work revealed a dependence of the anisotropy of reflected and emitted broadband radiances on the spatial resolution of the observations that had been overlooked in the formulation of the CERES strategy. This dependence on spatial resolution coupled with errors in scene identification led to view zenith angle dependent biases in the ERBE derived radiative fluxes. Scene identification will be greatly improved in CERES thereby alleviating somewhat the biases arising from the dependence of the anisotropy of the radiances on spatial resolution. Attention was then focused on the validity of plane-parallel radiative transfer theory which is relied on to characterize the scene types viewed by the CERES scanner. Again, viewing geometry dependent biases were found even for single-layered, overcast cloud systems. Such systems are taken to be the closest examples of plane-parallel clouds. At least some of the departures from plane-parallel behavior were evidently due to relatively small bumps on the tops of extensive stratus layers. The bumps cannot be resolved in the imagery that will be used to characterize the scenes viewed by the CERES scanner. As part of this investigation, the ice sheets of Greenland and Antarctica were shown to provide radiometrically stable targets for determining the visible and near infrared calibrations of radiometers. These targets were used to calibrate the reflected sunlight at visible wavelengths used in this study. Finally, the limitations of plane-parallel theory notwithstanding, the common practice of ignoring fractional cloud cover within the fields of view of imaging radiometers was shown to lead to biases in the retrieved cloud properties. The development of retrievals for pixel-scale cloud cover fraction is an attempt to reduce such bases. Work on these retrievals continues.

Coakley, James A., Jr.↗

TOPEX/Poseidon Microwave Radiometer (TMR): 1. Instrument Description and Antenna Temperature Calibration

The TOPEX/Poseidon Microwave Radiometer (TMR) is a 3-frequency radiometer flown on the TOPEX/Poseidon (T/P) satellite in low Earth orbit. It operates at 18, 21 and 37 GHz in a nadir only viewing direction which is co-aligned with the T/P radar altimeters. TMR monitors and corrects for the electrical path delay of the altimeter radar signal due to water vapor and non-precipitating liquid water in the atmosphere. This paper describes the TMR instrument and the radiometric instrument calibration required to derive antenna temperature (T_A) from the raw digital data. T_A precision of 0.4 K is predicted on orbit in all expected thermal environments. T_A accuracy of 0.5-0.6 K is expected following a post-launch field calibration campaign. When uncertainties related to antenna sidelobe corrections are included, this T_A accuracy yields a brightness temperature accuracy of 0.7- 0.8 K...

Ruf, C. S.↗

Visible infrared spin-scan radiometer atmospheric sounder radiometric calibration - An inflight evaluation from intercomparisons with HIRS and radiosonde measurements

The ability to conduct soundings from a geostationary platform has been demonstrated with the Visible IR spin-scan radiometer Atmospheric Sounder (VAS) aboard GOES-4. While a negative offset reaching 2.0-3.0 C for the upper atmospheric CO2 bands of VAS was observed in comparisons with High Resolution IR Radiation Sounder (HIRS) measurements and analyses of radiosonde data, VAS radiances are consistent with that material. After removing the offset, the temperature profiles derived from VAS radiances agree very well with those observed by radiosondes. Time variations in the atmospheric state are discernible from VAS soundings at three-hour intervals, and were confirmed by radiosonde observations.

Menzel, W. P.↗

L-Band Brightness Temperature Variations at Dome C and Snow Metamorphism at the Surface

The Antarctic Plateau is a promising site to monitor microwave radiometers' drift, and to inter-calibrate microwave radiometers, especially 1.4 GigaHertz (L-band) radiometers on board the Soil Moisture and Ocean Salinity (SMOS), and AquariusSAC-D missions. The Plateau is a thick ice cover, thermally stable in depth, with large dimensions, and relatively low heterogeneities. In addition, its high latitude location in the Southern Hemisphere enables frequent observations by polar-orbiting satellites, and no contaminations by radio frequency interference. At Dome C (75S, 123E), on the Antarctic Plateau, the substantial amount of in-situ snow measurements available allows us to interpret variations in space-borne microwave brightness temperature (TB) (e.g. Macelloni et al., 2007, 2013, Brucker et al., 2011, Champollion et al., 2013). However, to analyze the observations from the Aquarius radiometers, whose sensitivity is 0.15 K, the stability of the snow layers near the surface that are most susceptible to rapidly change needs to be precisely assessed. This study focuses on the spatial and temporal variations of the Aquarius TB over the Antarctic Plateau, and at Dome C in particular, to highlight the impact of snow surface metamorphism on the TB observations at L-band.

l-band↗