Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Solid Mechanics Code Verification: Contrasting Classical and Manufactured Reference Solutions

Verification results for Sierra/SM using inexact reference solutions have often exhibited unsatisfactory convergence behavior. With an understanding of the convergence behavior for these types of tests, one can avoid falsely attributing pathologies of the test with incorrectness of the code. Simple theoretical results highlight that for an inexact reference solution two conditions must be met to observe asymptotic convergence. These conditions, and the resulting types of convergence behaviors, are further illustrated with graphical examples depicting the exact, inexact reference, and sequence of numerical solutions as vectors (in a function space). A stress concentration problem is adopted to contrast convergence behaviors when using inexact (classical linear elastic) and exact (manufactured) reference solutions. Convergence is not initially attained with the classical solution. Convergence with the manufactured solution indicates the convergence failure with the classical reference did not result from code error and provides insight on how for this problem asymptotic convergence could be attained with the classical reference solution by modifying the computational models.

42 ENGINEERING↗

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Phase retrieval in x-ray lensless holography by reference beam tuning

We show the ability to determine the relative phase between the object and a reference scatterer by tuning the overall intensity and phase of the reference wave. The proposed reference-guided phase retrieval algorithm uses the relative phase as a constraint to iteratively reconstruct the object and the reference simultaneously, and thus does not require precisely defined reference structures. The algorithm also features rapid and reliable convergence and overcomes the uniqueness problem. The method is demonstrated by a soft-x-ray coherent imaging experiment that utilizes a large micrometer-sized reference structure that can be turned on and off, yielding an object image with resolution close to the reconstruction pixel size of 21 nm.

47 OTHER INSTRUMENTATION↗

Reference Model 4 Full Scale Geometry (RM4: Ocean Current Turbine)

Contains the Reference Model 4 (RM4) full scale geometry files of the Ocean Current Turbine, developed by the Reference Model Project (RMP). These full scale geometry files are saved as SolidWorks assembly, IGS, X_T, and STEP files, and require a CAD program to view. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 4 (RM4) is a "flying-wing" ocean current turbine concept intended for deployment in the Gulf Stream off the southeast coast of Florida. The RM4 device has four rotors, with a rotorless center nacelle housing the power electronics, attached on a straight wing 120 m long. The device is designed to be submerged ~50 m below the surface and is moored to the seabed. The RM4 uses buoyancy within the wing and the five nacelles to maintain its position in the water column. Each rotor has a diameter of 33 m and has a 1-MW power rating, yielding a total device rated power of 4 MW. The rotors on the left and right side of the wing rotate in opposite directions in order to balance the torque applied to the device. The rotorless center nacelle housing the power electronics serves to condition the power generated by the rotors before it is delivered to the grid.

16 TIDAL AND WAVE POWER↗

Introducing the Baseline Performance Reference (BPR) for Irradiance in PV System Applications

Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).

baseline performance reference↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements

Output from a reference solar cell mounted on a one-axis tracking surface is investigated using 350 nm to 1650 nm spectral irradiance measurements on selected days throughout the year. Comparisons are made to a Class-A pyranometer also mounted on the tracking surface. The ratio of the reference cell's measurements to reference pyranometer measurements exhibit systematic biases over the day and year. Most of this bias is linked to spectral, temperature, and angle-of-incident effects that differ for the reference cell and the pyranometer. The comparison is done for selected clear and totally cloudy days to determine the magnitude of the effects and to characterize they influence the measurements made with reference cells.

14 SOLAR ENERGY↗

Provision for Guaranteed Inertial Response in Diesel-Wind Systems via Model Reference Control

Frequency performance has been a crucial issue for islanded microgrids. On one hand, most distributed energy resources (DER) are converter-interfaced and do not inherently respond to frequency variations. On the other hand, current inertia emulation approach cannot provide guaranteed response. In this paper, a model reference control based inertia emulation strategy is proposed for the diesel-wind systems. Desired inertia can be precisely emulated through the proposed strategy. A typical frequency response model with parametric inertia is set to be the reference model. A measurement at a specific location delivers the information about the disturbance acting on the diesel-wind system to the reference model. The objective is for the speed of the diesel generator to track the reference so that the desired inertial response is realized. In addition, polytopic parameter uncertainty will be considered. The control strategy is configured in different ways according to different operating points. The parameters of the reference model are scheduled to ensure adequate frequency response under a pre-defined worst case. The controller is implemented in a nonlinear three-phase diesel-wind system fed microgrid using the Simulink software platform. Lastly, the results show exact synthetic inertia is emulated and adequate frequency response is achieved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural variant analysis of a cancer reference cell line sample using multiple sequencing technologies

The cancer genome is commonly altered with thousands of structural rearrangements including insertions, deletions, translocation, inversions, duplications, and copy number variations. Thus, structural variant (SV) characterization plays a paramount role in cancer target identification, oncology diagnostics, and personalized medicine. As part of the SEQC2 Consortium effort, the present study established and evaluated a consensus SV call set using a breast cancer reference cell line and matched normal control derived from the same donor, which were used in our companion benchmarking studies as reference samples. We systematically investigated somatic SVs in the reference cancer cell line by comparing to a matched normal cell line using multiple NGS platforms including Illumina short-read, 10X Genomics linked reads, PacBio long reads, Oxford Nanopore long reads, and high-throughput chromosome conformation capture (Hi-C). We established a consensus SV call set of a total of 1788 SVs including 717 deletions, 230 duplications, 551 insertions, 133 inversions, 146 translocations, and 11 breakends for the reference cancer cell line. To independently evaluate and cross-validate the accuracy of our consensus SV call set, we used orthogonal methods including PCR-based validation, Affymetrix arrays, Bionano optical mapping, and identification of fusion genes detected from RNA-seq. We evaluated the strengths and weaknesses of each NGS technology for SV determination, and our findings provide an actionable guide to improve cancer genome SV detection sensitivity and accuracy. A high-confidence consensus SV call set was established for the reference cancer cell line. A large subset of the variants identified was validated by multiple orthogonal methods.

59 BASIC BIOLOGICAL SCIENCES↗

Reference Model 1 Full Scale Geometry (RM1: Tidal Current Turbine)

Contains the Reference Model 1 (RM1) full scale geometry files of the Tidal Current Turbine, developed by the Reference Model Project (RMP). These full scale geometry files are saved as SolidWorks assembly, X_T, IGS, and STEP files, and require a CAD program to view. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 1 (RM1) is a dual variable-speed variable-pitch (VSVP) axial-flow tidal turbine device, designed for the Tacoma Narrows tidal current energy resource site in Puget Sound, Washington. RM1 comprises a monopile foundation and a crossarm assembly to mount the two rotors. The cross-arm assembly is nearly neutrally buoyant so the attached rotors can be recovered and redeployed with a minimal amount of lifting crane capacity; therefore, the design minimizes the handling requirements during deployment and recovery, which reduces overall cost in all O&M activities including access to the power conversion chain (PCC).

16 TIDAL AND WAVE POWER↗

Reference Model 4 Cost Breakdown (RM4: Ocean Current Turbine)

Contains the Reference Model 4 (RM4) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM4 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 4 (RM4) is a flying-wing ocean current turbine concept intended for deployment in the Gulf Stream off the southeast coast of Florida. The RM4 device has four rotors, with a rotorless center nacelle housing the power electronics, attached on a straight wing 120 m long. The device is designed to be submerged ~50 m below the surface and is moored to the seabed. The RM4 uses buoyancy within the wing and the five nacelles to maintain its position in the water column. Each rotor has a diameter of 33 m and has a 1-MW power rating, yielding a total device rated power of 4 MW. The rotors on the left and right side of the wing rotate in opposite directions in order to balance the torque applied to the device. The rotorless center nacelle housing the power electronics serves to condition the power generated by the rotors before it is delivered to the grid.

16 TIDAL AND WAVE POWER↗

Reference Model 1 Cost Breakdown (RM1: Tidal Current Turbine)

Contains the Reference Model 1 (RM1) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM1 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 1 (RM1) is a dual variable-speed variable-pitch (VSVP) axial-flow tidal turbine device, designed for the Tacoma Narrows tidal current energy resource site in Puget Sound, Washington. RM1 comprises a monopile foundation and a crossarm assembly to mount the two rotors. The cross-arm assembly is nearly neutrally buoyant so the attached rotors can be recovered and redeployed with a minimal amount of lifting crane capacity; therefore, the design minimizes the handling requirements during deployment and recovery, which reduces overall cost in all O&M activities including access to the power conversion chain (PCC).

16 TIDAL AND WAVE POWER↗

Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model

Purpose The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three‐dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such a way that only a few reference skeletal models have been developed to date, and which are based upon microimaging of a limited number of cadaveric bone spongiosa cores. The question then arises as to what degree of accuracy is achievable from reference skeletal dose models when applied to individual patients or specific exposed populations? Methods Patient variability in marrow dosimetry were quantified for three skeletal sites — the ribs, lumbar vertebrae, and cranium — for the beta‐emitters 45 Ca, 153 Sm, and 90 Y, and the alpha‐particle emitters 223 Ra, 219 Rn, and 215 Po, the latter two being the immediate progeny of the former. For each radionuclide and bone site, three patient parameters were altered from their values in the reference model: (1) bone size as a surrogate for patient stature, (2) marrow cellularity as a surrogate for age‐ or disease‐related changes in marrow adiposity, and (3) the trabecular bone volume fraction as a surrogate for bone mineral density. Marrow dose variability is expressed as percent differences in the radionuclide S value given by the reference model and the patient‐parameterized model. The impact of radionuclide biokinetics on marrow dosimetry was not considered. Results Variations in overall bone size play a very minor role in active marrow dose variability. Marrow cellularity is a significant factor in dose variability for active marrow self‐irradiation, but it plays no role for radionuclides localized to the trabecular bone matrix. Variations in trabecular bone volume fractions impact the active marrow dose variability for short‐range particle emitters 45 Ca, 223 Ra, 219 Rn, and 215 Po in the vertebrae and ribs, skeletal sites with small spongiosa proportions of trabecular bone. In the cranium, with its relative high proportion of trabecular bone, significant differences in marrow dosimetry from the reference model were noted for all radionuclides. Conclusions Skeletal models of active marrow dosimetry should be more fully parameterized to permit closer matching to patient bone density and marrow cellularity, particularly when considering short‐range particle emitters localized to either the bone trabeculae or active marrow, respectively.

Geyer, Amy M.↗

A reference high-pressure CH4 adsorption isotherm for zeolite Y: results of an interlaboratory study

Abstract This paper reports the results of an international interlaboratory study led by the National Institute of Standards and Technology (NIST) on the measurement of high-pressure surface excess methane adsorption isotherms on NIST Reference Material RM 8850 (Zeolite Y), at 25 °C up to 7.5 MPa. Twenty laboratories participated in the study and contributed over one-hundred adsorption isotherms of methane on Zeolite Y. From these data, an empirical reference equation was determined, along with a 95% uncertainty interval ( U k =2 ). By requiring participants to replicate a high-pressure reference isotherm for carbon dioxide adsorption on NIST Reference Material RM 8852 (ZSM-5), this interlaboratory study also demonstrated the usefulness of reference isotherms in evaluating the performance of high-pressure adsorption experiments.

Nguyen, H. G. T. (ORCID:0000000210527565)↗

Reference surface excess isotherms for carbon dioxide adsorption on ammonium ZSM-5 at various temperatures

Abstract This work is part of the effort at the Facility for Adsorbent Characterization and Testing (FACT lab) at the National Institute of Standards and Technology (NIST) to develop reference materials, reference data, and measurement best practices for adsorption metrology. High-pressure surface excess isotherms for CO 2 adsorption on NIST Reference Material 8852 (ammonium ZSM-5) at 15 °C, 25 °C, and 35 °C are reported, expanding on a FACT Lab-organized international interlaboratory study on this sorbent/sorbate pair at 20 °C. The range of temperatures of the present study is of interest for many CO 2 adsorption measurements and applications. Measurements were made using five different adsorption instruments, both manometric and gravimetric. Excellent agreement in the measured isotherms among the instruments was found. An empirical reference equation of the form, $${n}_{ex,ref}({P}_{eq})=\frac{c}{\{{1+\mathrm{exp}[\left(-\mathrm{ln}\left(P\right)+a\right)/b ]\}}^{b }} ,$$ n e x , r e f ( P eq ) = c { 1 + exp [ - ln P + a / b ] } b , [ n ex,ref is surface excess uptake (mmol/g); P eq is equilibrium pressure (MPa); P is ( P eq )/(1 MPa)]; a , b , c are constants] and the 95% uncertainty interval were determined for the isotherms at each of the temperatures. Lastly, the isosteric heat of adsorption is estimated from absolute isotherms derived from the surface excess reference data.

Nguyen, Huong Giang T. (ORCID:0000000210527565)↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum mechanics in non-inertial reference frames: Time-dependent rotations and loop prolongations

This is the fourth in a series of papers on developing a formulation of quantum mechanics in non-inertial reference frames. This formulation is grounded in a class of unitary cocycle representations of what we have called the Galilean line group, the generalization of the Galilei group to include transformations amongst non-inertial reference frames. These representations show that in quantum mechanics, just as the case in classical mechanics, the transformations to accelerating reference frames give rise to fictitious forces. In previous work, we have shown that there exist representations of the Galilean line group that uphold the non-relativistic equivalence principle as well as representations that violate the equivalence principle. In these previous studies, the focus was on linear accelerations. In this paper, we undertake an extension of the formulation to include rotational accelerations. We show that the incorporation of rotational accelerations requires a class of loop prolongations of the Galilean line group and their unitary cocycle representations. We recover the centrifugal and Coriolis force effects from these loop representations. Loops are more general than groups in that their multiplication law need not be associative. Hence, our broad theoretical claim is that a Galilean quantum theory that holds in arbitrary non-inertial reference frames requires going beyond groups and group representations, the well-established framework for implementing symmetry transformations in quantum mechanics. -- Highlights: •A formulation of Galilean quantum mechanics in non-inertial reference frames is presented. •The Galilei group is generalized to infinite dimensional Galilean line group. •Loop prolongations of Galilean line group contain central extensions of Galilei group. •Unitary representations of the loops are constructed. •These representations lead to terms in the Hamiltonian corresponding to fictitious forces, including centrifugal and Coriolis forces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed Chemical Kinetic Reaction Mechanisms for Primary Reference Fuels for Diesel Cetane Number and Spark-Ignition Octane Number

For the first time, a detailed chemical kinetic reaction mechanism is developed for primary reference fuel mixtures of n-hexadecane and 2,2,4,4,6,8,8-heptamethyl nonane for diesel cetane ratings. The mechanisms are constructed using existing rules for reaction pathways and rate expressions developed previously for the primary reference fuels for gasoline octane ratings, n-heptane and iso-octane. These reaction mechanisms are validated by comparisons between computed and experimental results for shock tube ignition and for oxidation under jet-stirred reactor conditions. The combined kinetic reaction mechanism contains the submechanisms for the primary reference fuels for diesel cetane ratings and submechanisms for the primary reference fuels for gasoline octane ratings, all in one integrated large kinetic reaction mechanism. Representative applications of this mechanism to two test problems are presented, one describing fuel/air autoignition variations with changes in fuel cetane numbers, and the other describing fuel combustion in a jet-stirred reactor environment with the fuel varying from pure 2,2,4,4,6,8,8-heptamethyl nonane (Cetane number of 15) to pure n-hexadecane (Cetane number of 100). The final reaction mechanism for the primary reference fuels for diesel fuel and gasoline is available on the web.

30 DIRECT ENERGY CONVERSION↗