Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Molecular-Scale Structure of Electrode–Electrolyte Interfaces: The Case of Platinum in Aqueous Sulfuric Acid

Knowledge of the molecular composition and electronic structure of electrified solid-liquid interfaces is key to understanding elemental processes in heterogeneous reactions. Using X-ray absorption spectroscopy in the interface-sensitive electron yield mode (EY-XAS), first-principles electronic structure calculations, and multiscale simulations, we determined the chemical composition of the interfacial region of a polycrystalline platinum electrode in contact with aqueous sulfuric acid solution at potentials between the hydrogen and oxygen evolution reactions. We found that between 0.7 and 1.3 V vs Ag/AgCl the electrical double layer (EDL) region comprises adsorbed sulfate ions with hydrated hydronium ions in the next layer. No evidence was found for bisulfate or Pt-O/Pt-OH species, which have very distinctive spectral signatures. In addition to resolving the long-standing issue of the EDL structure, our work establishes interface- and element-sensitive EY-XAS as a powerful spectroscopic tool for studying condensed phase, buried solid-liquid interfaces relevant to various electrochemical processes and devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Guided conversion to enhance cation detection in water using laser-induced breakdown spectroscopy

A novel approach, named guided conversion enhancement, has been established to improve the laser-induced breakdown spectroscopy (LIBS) sensitivity of cation detection in water. Two processes were involved in this approach: the main part was replacement reaction that converted the cations in water to solid granules on the surface of an immersed metallic sheet; the other was electric assistance that increased local cation concentration and strengthened the reaction. With the aid of replacement reaction and an electric field, a detection limit of 16 ppb was achieved for copper cation (Cu{sup 2+}) detection in a water solution of CuSO4. The obtained results suggest that this approach has significant potential to be developed as an effective method for underwater cation detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improving on the interparticle connection for performance enhancement of flexible quantum dot sensitized solar cells

Highlights: • TiO{sub 2} slurries have been prepared by a three-step process for the photo-anode of flexible solar cells. • Interparticle connection of photo-anodes has been improved in flexible solar cells. • This flexible QDSSCs exhibits excellent photovoltaic performance and charge transfer property. • There has excellent curving stability on the photovoltaic performance of flexible QDSSCs. - Abstract: Flexible photovoltaic devices have wide applications in many unique areas. However, the interparticle connection of photo-electrode in flexible photovoltaic devices still needs to be improved. Here, TiO{sub 2} slurries have been prepared by a three-step process, which are employed to prepare the photo-anode for flexible CuInS{sub 2} quantum dot sensitized solar cells (QDSSCs). 5 nm-sized TiO{sub 2} nanoparticles and hydrochloric acid (HCl) have been introduced in 20 nm-sized TiO{sub 2} based photo-electrodes under TiO{sub 2}/HCl mass ratio of 3:1, which exhibits excellent photovoltaic performance and charge transfer property. Due to the interparticle connection enhancement by suitable content of 5 nm-sized TiO{sub 2} nanoparticles, photo-anodes with the 20/5-TiO{sub 2} nanoparticles mass ratio of 3:1 exhibits the better optical absorption property and photovoltaic performance of flexible QDSSCs. Moreover, there has maintained 98% photovoltaic conversion efficiency of flexible QDSSCs with the seriously curving condition, which can be considered the great foreground in future applications.

14 SOLAR ENERGY↗

Gamma Imaging Improvements for GrayQb™

SRNL’s Imaging, Robotics, and Radiation Systems Group has had several successful field deployments with the GrayQb™, a custom designed radiation mapping device. The GrayQb™ returned consistent radiation contour maps through its deployment and demonstrated its effectiveness in quickly and inexpensively capturing images of radiation hot spots. To process the images from the GrayQb™, the device must be recovered between each deployment. This is due to the GrayQb™’s use of Phosphor Storage Plates (PSPs), which are a standard X-ray imaging material in dentistry and oral applications. PSPs are highly sensitive to radiation; however, currently they must be processed through an external scanner. SRNL designed the GrayQb™ for radiation areas, and much effort is required to deploy and recover the GrayQb™. To reduce time and resources spent deploying and recovering the GrayQb™, SRNL is working to upgrade the device to read PSP images and transmit image data to an external location using an internal camera system eliminating the need to remove the PSP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Kinetics of Stable Isotopes (Final Report)

Stable isotopes are sensitive indicators to the mass transport and chemical reactions that occur during potentiostat-controlled electroplating of metals from aqueous (and some non-aqueous) metal-salt solutions. The goal of this research program is to measure the stable isotope fractionation during electrochemical processes, how the isotope-dependent rates are sensitive to chemistry, temperature, and electrochemical kinetics, and to use these measurements to develop a theoretical framework for a kinetic isotope effect that is able to predict kinetic isotope fractionation factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of heat input on the microstructure, residual stresses and corrosion resistance of 304L austenitic stainless steel weldments

Austenitic stainless steels are widely used in high performance pressure vessels, nuclear, chemical, process and medical industry due to their very good corrosion resistance and superior mechanical properties. However, austenitic stainless steels are prone to sensitization when subjected to higher temperatures (673 K to 1173 K) during the manufacturing process (e.g. welding) and/or certain applications (e.g. pressure vessels). During sensitization, chromium in the matrix precipitates out as carbides and intermetallic compounds (sigma, chi and Laves phases) decreasing the corrosion resistance and mechanical properties. In the present investigation, 304L austenitic stainless steel was subjected to different heat inputs by shielded metal arc welding process using a standard 308L electrode. The microstructural developments were characterized by using optical microscopy and electron backscattered diffraction, while the residual stresses were measured by X-ray diffraction using the sin{sup 2}ψ method. It was observed that even at the highest heat input, shielded metal arc welding process does not result in significant precipitation of carbides or intermetallic phases. The ferrite content and grain size increased with increase in heat input. The grain size variation in the fusion zone/heat affected zone was not effectively captured by optical microscopy. This study shows that electron backscattered diffraction is necessary to bring out changes in the grain size quantitatively in the fusion zone/heat affected zone as it can consider twin boundaries as a part of grain in the calculation of grain size. The residual stresses were compressive in nature for the lowest heat input, while they were tensile at the highest heat input near the weld bead. The significant feature of the welded region and the base metal was the presence of a very strong texture. The texture in the heat affected zone was almost random. - Highlights: • Effect of heat input on microstructure, residual stresses and corrosion is studied. • HAZ and width of dendrite in the welded region increase with heat input. • Residual stresses are tensile near the welded region after the highest heat input. • Welded region has the highest pit density after highest heat input. • Dendrites and δ-ferrite were highly oriented in the welded region.

36 MATERIALS SCIENCE↗

Measurements of proton capture in the A=100–110 mass region: Constraints on the In 111 (γ,p)/(γ,n) branching point relevant to the γ process

The γ process is an explosive astrophysical scenario, which is thought to be the primary source of the rare proton-rich stable p nuclei. However, current γ-process models remain insufficient in describing the observed p-nuclei abundances, with disagreements up to two orders of magnitude. A sensitivity study has identified 111 In as a model-sensitive (γ,p)/(γ,n) branching point within the γ process. Constraining the involved reaction rates may have a significant impact on the predicted p-nuclei abundances. Here we report on measurements of the cross sections for 102 Pd (p,γ) 103 Ag, 108 Cd (p,γ) 109 In, and 110 Cd (p,γ) 111 In reactions for proton laboratory energies 3–8 MeV using the high efficiency total absorption spectrometer and the γ-summing technique. These measurements were used to constrain Hauser-Feshbach parameters used in talys 1.9, which constrains the 111 In(γ,p) 110 Cd and 111 In(γ,n) 110 Ag reaction rates. The newly constrained reaction rates indicate that the 111 In(γ,p)/(γ,n) branching point occurs at a temperature of 2.71 ± 0.05 GK, well within the temperature range relevant to the γ process. These findings differ significantly from previous studies and may impact the calculated abundances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The NOL Gap Test: Past, present, and future

A brief history of the development of the gap test is presented with emphasis on accumulated knowledge of how best to use it as a tool to assess relative shock sensitivity of explosives and propellants. Present information about the detonation process in build-up, steady state, and failure is used to show that failure diameter cannot give the desired shock sensitivity assessment. Suggestions are made for improving the test to an experiment. The use of spherical donors, water as attenuator, and camera instrumentation are briefly discussed.

Jacobs, S. J.↗

Analysis of the Optical Design for the SAFIR Telescope

SAFIR, the Single Aperture Far Infra Red Observatory, is a very powerful space mission that will achieve background-limited sensitivity in the far infrared-submillimeter spectral region. Many processes of enormous interest to astronomers can best be studied in this wavelength range, but require the demanding combination of high sensitivity, good angular resolution, and spectroscopic capability. SAFIR is a 10m class telescope to offering good angular resolution, cooled to below 5 K in order to achieve background-limited sensitivity, and equipped with a complement of large-format cameras and broadband spectrometers. Successful operation of such a facility is critically dependent on achieving the level of sensitivity expected, but this is rendered difficult by potential pickup from unwanted sources of radiation. This problem is exacerbated by the fact that the emission from the optical system itself is minimal due to its low temperature, thus emphasizing the importance of minimizing pickup from unwanted astronomical sources of radiation, including the emission from dust in our solar system (analogous to the zodiacal light, hence 'zodi'), and the emission from warm dust in the Milky Way (Galactic 'cirrus').

antenna radiation patterns↗

Expected Power-Utility Maximization Under Incomplete Information and with Cox-Process Observations

We consider the problem of maximization of expected terminal power utility (risk sensitive criterion). The underlying market model is a regime-switching diffusion model where the regime is determined by an unobservable factor process forming a finite state Markov process. The main novelty is due to the fact that prices are observed and the portfolio is rebalanced only at random times corresponding to a Cox process where the intensity is driven by the unobserved Markovian factor process as well. This leads to a more realistic modeling for many practical situations, like in markets with liquidity restrictions; on the other hand it considerably complicates the problem to the point that traditional methodologies cannot be directly applied. The approach presented here is specific to the power-utility. For log-utilities a different approach is presented in Fujimoto et al. (Preprint, 2012).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Molten Salt Electrochemical Reactors Outside of a Glovebox

Molten salt electrochemical reduction (MSER) offers an electrified method for the reduction, refining, and recycling of metals such as iron and metallurgical grade silicon at high efficiency and lower temperatures than traditional methods, which use temperatures >1000C and carbon-based reductants. However, salts appropriate for MSER are moisture and air sensitive, necessitating air-free methods of processing and testing which is often acomplished with a glovebox. Glovebox operations are cumbersome and difficult to troubleshoot reactor issues. We have developed a robust method of testing chloride and carbonate salts in molten salt reactors outside of a glovebox for silicon and carbon production and steel carburization. We highlight a practical guide for glovebox-free testing of molten salt electrochemical reactors to reduce the barriers to performing this type of work. Our aim is to enable other research groups to step into this field with simple and repeatable reactor configurations.

47 OTHER INSTRUMENTATION↗

Spacelab user implementation assessment study. Volume 1: Concept development and evaluation

The total matrix of alternate Spacelab processing concepts and the rejection rationale utilized to reduce the matrix of 243 alternates to the final candidate processing concepts are developed. The work breakdown structure used for the systematic estimation and compilation of integration and checkout resources is presented along with descriptors of each element. Program models are provided of the space transportation system, the Spacelab, the orbiter, and the ATL that were used as the basis for the study trades, analyses, and optimizations. Resource requirements for all processing concepts are summarized along with the optimizations of the processing concepts. Concept evaluations including flight-rate sensitivities of the GSE, facilities, Spacelab hardware elements, and personnel are delineated. An analysis is presented of the applicability of the candidate concepts to potential spacelab users. The impact of the use of the western test range as an orbiter/spacelab launch site on the candidate processing concepts is evaluated. An assessment of the geographical co-location of experiment, Spacelab, and orbiter-cargo integration is included. Ownership options of the support module/system igloo are discussed.

Source record↗

Solution processed metal-doped NiS/PEDOT:PSS composite thin films as an efficient electrode for quantum-dot sensitized solar cells

Highlights: • Metal-doped NiS/PEDOT:PSS chrysanthemum flower like structure was fabricated. • Deposition of PEDOT: PSS into Cu-NiS enhances the V{sub oc} and PCE. • Introduction of PEDOT: PSS acts as a passivation layer for reducing charge recombination. • Cu-NiS/PEDOT:PSS shows higher onset potential with higher limiting current density. - Abstract: Cu-doped NiS with PEDOT:PSS chrysanthemum flower-like structures, which were composed of many nanopetal bunches in a radial fashion, were synthesized using a modest, eco-friendly and cost effective method. The 5 wt.% Cuph/PEDOT:PSS produced a minute amount of PEDOT:PSS, which exhibiting outstanding electrochemical performance in QDSSCs. The synergetic effects of the composite were investigated and a PCE of 4.87%, fill factor of 0.51, J{sub sc} of 13.75 mA cm{sup −2}, and V{sub oc} of 0.549 V in a polysulfide electrolyte were obtained. The electrode exhibited great electrocatalytic activities and lower charge transfer resistance than that of the bare NiS and Cu-doped NiS, making it a promising material for both fuel cells and QDSSCs. The improved performance of the 5 wt.% Cuph/PEDOT:PSS electrode was attributed mainly to the large surface area, greater electrical conductivity and high electrocatalytic activity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combining X-ray Absorption and X-ray Diffraction Techniques for in Situ Studies of Chemical Transformations in Heterogeneous Catalysis:Advantages and Limitations

Recent advances in catalysis instrumentations include synchrotron-based facilities where time-resolved X-ray scattering and absorption techniques are combined in the same in situ or operando experiment to study catalysts at work. To evaluate the advances and limitations of this method, we performed a series of experiments at the new XAFS/XRD instrument in the National Synchrotron Light Source. Nearly simultaneous X-ray diffraction (XRD) and X-ray absorption fine-structure (XAFS) measurements of structure and kinetics of several catalysts under reducing or oxidizing conditions have been performed and carefully analyzed. For CuFe{sub 2}O{sub 4} under reducing conditions, the combined use of the two techniques allowed us to obtain accurate data on kinetics of nucleation and growth of metallic Cu. For the inverse catalyst CuO/CeO{sub 2} that underwent isothermal reduction (with CO) and oxidation (with O{sub 2}), the XAFS data measured in the same experiment with XRD revealed strongly disordered Cu species that went undetected by diffraction. These and other examples emphasize the unique sensitivity of these two complementary methods to follow catalytic processes in the broad ranges of length and time scales.

43 PARTICLE ACCELERATORS↗

Using support vector machines to improve elemental ion identification in macromolecular crystal structures

A method to automatically identify possible elemental ions in X-ray crystal structures has been extended to use support vector machine (SVM) classifiers trained on selected structures in the PDB, with significantly improved sensitivity over manually encoded heuristics. In the process of macromolecular model building, crystallographers must examine electron density for isolated atoms and differentiate sites containing structured solvent molecules from those containing elemental ions. This task requires specific knowledge of metal-binding chemistry and scattering properties and is prone to error. A method has previously been described to identify ions based on manually chosen criteria for a number of elements. Here, the use of support vector machines (SVMs) to automatically classify isolated atoms as either solvent or one of various ions is described. Two data sets of protein crystal structures, one containing manually curated structures deposited with anomalous diffraction data and another with automatically filtered, high-resolution structures, were constructed. On the manually curated data set, an SVM classifier was able to distinguish calcium from manganese, zinc, iron and nickel, as well as all five of these ions from water molecules, with a high degree of accuracy. Additionally, SVMs trained on the automatically curated set of high-resolution structures were able to successfully classify most common elemental ions in an independent validation test set. This method is readily extensible to other elemental ions and can also be used in conjunction with previous methods based on a priori expectations of the chemical environment and X-ray scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗