At least 145 records · Page 8

MO-DE-BRA-01: Flipped Physics Courses Within a Radiologic Technologist Program: Video Production and Long Term Outcomes

Purpose: To determine if the flipped class format has an effect on examination results for a radiologic technologist (RT) program and discuss benefits from creating video resources. Methods: From 2001–2015, students had taken both a radiological physics and quality control (QC) class as a part of their didactic training. In 2005/2006, the creation of videos of didactic lectures and QC test demonstrations allowed for a flip where content was studied at home while exercises and reviews were done in-class. Final examinations were retrospectively reviewed from this timeframe. 12 multiple choice physics questions (MCP) and 5 short answer QC questions (SAQC) were common to pre and post flip exams. The RT program’s ARRT exam scores were also obtained and compared to national averages. Results: In total, 36 lecture videos and 65 quality control videos were created for the flipped content. Data was ∼2.4GB and distributed to students via USB or CD media. For MCP questions, scores improved by 7.9% with the flipped format and significance (Student’s t-test, p<0.05) was found for 3 of the 12 questions. SAQC questions showed improvement by 14.6% and significance was found for 2 of the 5 questions. Student enrollment increased from ∼14 (2001–2004) to ∼23 students (2005–15). Content was continuously added post-flip due to the efficiency of delivery. The QC class in 2003 covered 45 test setups in-class while 65 were covered with video segments in 2014. Flipped materials are currently being repurposed. In 2015, this video content was restructured into an ARRT exam review guide and in 2016, the content was reorganized for fluoroscopy training for physicians. Conclusion: We believe that flipped classes can improve efficiency of content delivery and improve student performance even with an increase in class size. This format allows for flexibility in learning as well as re-use in multiple applications.

07 ISOTOPE AND RADIATION SOURCES↗

RCT: Module 2.10, Access Control and Work Area Setup, Course 8776

This course presents information on radiological work permits (RWPs), various types of postings used in radiological areas, radiological area setups, access controls, and releases of material from radiological areas. All of these are fundamental duties of RCTs. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

DETECTION OF NUCLEAR OR OTHER RADIOLOGICAL MATERIALS OUT OF REGULATORY CONTROL AS CRIMINAL/UNAUTHORIZED THREATS TO MAJOR PUBLIC EVENTS

Major Public Events (MPEs), by their nature, draw great public interest and receive intense media attention. They can be anything from sporting events (e.g., Olympics, World Cups) to political summits to large festivals. The threat of nuclear or other radiological materials out of regulatory control during these events is of particular concern. A terrorist could use this material as a dirty bomb to disperse radioactive material in a stadium, or hide dangerous radioactive sources in a garbage can to expose people to harmful radiation, leading to fear and uncertainty. The requirements for nuclear security, preparedness, and operational capabilities for nuclear/radiological detection at MPEs have steadily increased in recent years. Many countries have gained considerable experience in recent years in nuclear security operations at MPEs when hosting these events. Dozens of MPEs hosted around the world each year now provide some level of nuclear security as part of their overall security plan. Several training workshops and courses, co-sponsored by the U.S. Department of Energy / National Nuclear Security Administration and the International Atomic Energy Agency, and conducted through bilateral agreements, are offered each year. These workshops and courses provide the opportunity to share best practices and lessons learned and aid countries to build capacity for nuclear security at their MPEs. Additionally, the International Atomic Energy Agency provides guidance for the detection of radiological threat materials out of regulatory control through the Nuclear Security Systems and Measures for Major Public Events, IAEA Nuclear Security Series No. 18.

61 RADIATION PROTECTION AND DOSIMETRY↗

National and International Assistance in the Technical Assessment of Nuclear and other Radiological Materials out of Regulatory Control

Considerable resources are dedicated worldwide to detect illicit materials of all types amid the concern of their potential use in criminal acts or acts of terrorism. Of particular concern are illicit nuclear and radiological materials as they have potential to cause serious harm to the general public if not maintained under regulatory control. As such, the international community has developed recommendations and guidance for States and their Competent Authorities to establish, implement, maintain, and strengthen their nuclear security regimes. The International Atomic Energy Agency (IAEA) provides recommendations for the security of nuclear and other radioactive material out of regulatory control through the publication Nuclear Security Recommendations on Nuclear and Other Radioactive Material out of Regulatory Control, Nuclear Security Series No.15. Based on this guidance and national/international practical experience and best practices, the international community has made considerable advances in the detection, interdiction, and adjudication of nuclear and other radiological materials out of regulatory control. The United States Department of Energy, National Nuclear Security Administration (DOE/NNSA), Office of Nuclear Incident Policy and Cooperation has national/international experience to share on providing emergency responders and front line officers assistance in the technical assessment of interdicted nuclear and other radioactive Materials Out of Regulatory Control (MORC).

61 RADIATION PROTECTION AND DOSIMETRY↗

Pilot Scale Advanced Fogging Demonstration

Radiological contamination control is crucial during decommissioning and demolition (D&D) activities, as well as during modifications to existing radiological systems. It is well known that contamination, in some cases substantial contamination, is present throughout the exhaust ductwork in several older processing facilities within the Department of Energy (DOE) complex, due to years of processing radioactive materials in areas served by closed ventilation systems. Accumulations of radioactive dust and lint – commonly found in laundry facilities, exhaust ventilation ducting, and exhaust stacks – present a specific contamination control issue. Particle suspension is more likely to occur during cleaning, modification, or demolition of these systems and during disposal site exhumation. In a recent demolition of large ventilation ducting (~10’ × 10’ cross section, ~100’ long) at Brookhaven National Laboratory, a spray coating was manually applied to the inside of the duct – requiring painters, dressed in anti-contamination clothing and an airline respirator system, to enter the duct.1 The advanced fogging technique offers an alternative method to mitigate these airborne contamination hazards with minimal personnel entry. Experiments in 2006 developed a useful fog solution using three different chemical constituents. Optimization of the fog recipe and use of commercially available equipment were identified as needs that had not been addressed. During 2012 development work it was noted that low concentrations of the components hampered coverage and drying in the United Kingdom’s National Nuclear Laboratory’s testing much more so than was evident in the 2006 tests. In fiscal year 2014 the Idaho National Laboratory undertook a systematic optimization of the fogging formulation and conducted a non-radioactive, pilot scale demonstration using commercially available fogging equipment. While not as sophisticated as the equipment used in earlier testing, the new approach is much less expensive and readily available for smaller scale operations. Pilot scale testing was important to validate new equipment of an appropriate scale, optimize the chemistry of the fogging solution, and to realize the conceptual approach.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-I-61: Assessment and Characterization of the Built-in Internal Photometer of Primary Diagnostic Monitors

Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barco MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.

60 APPLIED LIFE SCIENCES↗

Analysis of Nuclear Materials on Both Sides of Regulatory Control: from IAEA Safeguards to Global Counter-Nuclear Smuggling

Global nuclear security is dependent upon the sustained and verifiable control of radiological and nuclear (R/N) materials within nuclear facilities, under the administrative purview of national governments. It is the responsibility of each country to account for their R/N materials holdings and to ensure that they do not escape regulatory control and fall into the wrong hands. The Office of Nuclear Smuggling Detection and Deterrence (NSDD) is tasked with providing support to foreign partners in developing the tools and expertise to detect, disrupt, and investigate R/N materials encountered out of regulatory control, in such circumstances as at border crossings and other checkpoints, or in the course of routine policework. Thankfully, such incidents are infrequent, and NSDD continues to work bilaterally with partner countries to strengthen their capabilities to combat nuclear smuggling and trafficking incidents in their countries. For the vast majority of R/N materials that remain under regulatory control, however, it is critical that their safe storage and use be independently verified. Even a single loss incident of R/N materials, particularly of special nuclear materials (highly-enriched uranium and plutonium) has the potential to cause a catastrophe. How can the international community be assured that R/N materials currently under national regulatory control remain there?

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants

Control room modernization in the commercial nuclear power industry often takes the form of phased system-by-system upgrades that result in hybrid control rooms with digital and analog equipment. Ensuring that these upgrades results in enhanced human performance and more intuitive interfaces, researchers at INL have been supporting the design of upgraded systems in coordination with a large scale modernization effort at a partner utility. This report describes the experimental evaluation of a liquid radiological waste control room concept which investigated the use of color in system overview screens. The results indicated that maintaining existing color conventions to indicate component status yielded no benefit and in some cases caused a detriment to performance. The researchers recommended using a minimal muted color in overview screens, but advocated using color to enhance understanding of different flow paths and using saturated color to highlight abnormal operating states.

99 GENERAL AND MISCELLANEOUS↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.2 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.2 (RSAC-7) is the newest version of the RSAC legacy code. It calculates the consequences of a release of radionuclides to the atmosphere. A user can generate a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 can be used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events and to evaluate safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program was designed for users who are familiar with radiological dose assessment methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RCT Continuing Training: RCT Job Coverage and CONOPS

RCT Continuing Training covering all of the necessary steps associated with RCT, and how conduct of operations ties in with this process. The terminal objective of this training is: Given the need to perform radiological job coverage, recognize the requirements to maintain radiological work control in accordance with P121, Radiation Protection, RP-PROG-TP-200, Radiation Protection Manual, and P315, Conduct of Operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Shielding Analysis for the 1012 400 MeV Linac Building

EIC is planning to purchase a 400 MeV turnkey pre-injector linear accelerator (Linac) which will be in a new building at the end of an existing RHIC tunnel at 12 o’clock. The building will contain the Linac Tunnel and associated accelerating structures, Klystron Gallery and waveguides, laser, utility, and control rooms. This report only examines the radiation source term produced by operating the Linac and not supplemental shielding that may be required to shield the Klystrons or solid state amplifiers in the Klystron Gallery from the x rays they emit. Normal Portland concrete blocks are planned to provide shielding between the Linac vault and the occupiable portions of the building per the attached drawing. It is expected that this facility will not be routinely occupied during operations (post commissioning). The shielding design considers EIC’s draft Shielding Policy that states shielding and other controls for areas where access is controlled for radiological purposes will be designed so that an ambient dose of 100 mrem per year to a worker is not likely.

43 PARTICLE ACCELERATORS↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.4 (RSAC-7) is the newest version of the RSAC legacy code. RSAC-7 calculates the consequences of a release of radionuclides to the atmosphere. Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program is designed for users who are familiar with radiological dose assessment methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.0 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.0 (RSAC-7) is the newest version of the RSAC legacy code. It calculates the consequences of a release of radionuclides to the atmosphere. A user can generate a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 can be used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events and to evaluate safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program was designed for users who are familiar with radiological dose assessment methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗