Evaluation of an Accelerated ELDRS Test Using Molecular Hydrogen

An accelerated total ionizing dose (TID) hardness assurance test for enhanced low dose rate sensitive (ELDRS) bipolar linear circuits, using high dose rate tests on parts that have been exposed to molecular hydrogen, has been proposed and demonstrated on several ELDRS part types. In this study several radiation-hardened "ELDRS-free" part types have been tested using this same approach to see if the test is overly conservative.

radiation effects↗

NASA Goddard Space Flight Center’s Recent Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single-Event Effects (SEE)↗

Thermal Radiometer Signal Processing Using Radiation Hard CMOS Application Specific Integrated Circuits for Use in Harsh Planetary Environments

Thermal radiometers such as proposed for the Europa Clipper flyby mission require low noise signal processing for thermal imaging with immunity to Total Ionizing Dose (TID) and Single Event Latchup (SEL). Described is a second generation Multi- Channel Digitizer (MCD2G) Application Specific Integrated Circuit (ASIC) that accurately digitizes up to 40 thermopile pixels with greater than 50 Mrad (Si) immunity TID and 174 MeV-sq cm/mg SEL. The MCD2G ASIC uses Radiation Hardened By Design (RHBD) techniques with a 180 nm CMOS process node.

Focal Plane Assembly↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

A TID and SEE Characterization of Multi-Terabit COTS 3D NAND Flash

Single-event effects and total ionizing dose testing are described for a 32-layer NAND flash memory, in both SLC and MLC configurations, with special considerations for unique three-dimensional test results. Extraction of three-dimensional heavy-ion test data presents a unique visualization of angular effects in NAND flash. Pattern dependence differences between SLC and MLC mode are noted, along with slightly non-uniform angular cross-section results due to the complex volume. Finally, TID data under different operating and bias conditions shows that the failure point remains the higher-voltage erasure circuitry.

Flash Memory↗

Resources for Radiation Test Data

The performance of electronic devices in a space radiation environment is often limited by susceptibility to single-event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Interpreting the results of SEE, TID, and DD testing of complex devices is quite difficult given the rapidly changing nature of both technology and the related radiation issues. Radiation testing is performed to establish the sensitivities of candidate spacecraft electronics to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transients (SETs), TID, and DD effects. Knowing where to search for these test results is a valuable resource for the aerospace engineer or spacecraft design engineer. This poster is intended to be a resource tool for finding radiation test data.

Single Event Effects (SEE)↗

Radiation Response of Ga 2 O 3 MOSFETs Probed via Focused Particle Beams

Gallium Oxide (Ga 2 O 3 ), particularly in its β-phase, is attracting lots of interest for high-power and high-voltage electronics due to its wide bandgap, high breakdown field, and thermal stability. This study investigates the radiation response of Ga 2 O 3 Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) under Total Ionizing Dose (TID) and Displacement Damage (DD) conditions, which are critical for applications in radiation environments. Utilizing a dual-beam Focused Ion Beam and Scanning Electron Microscope setup, microscale analysis of radiation effects on individual devices is performed. The findings reveal distinct behaviors under TID and DD + TID conditions, with TID leading to threshold voltage shifts due to trapped charges, while DD results in decreased drive current attributed to increased carrier scattering from lattice defects. Notably, it is demonstrated that the TID effect can be mitigated through dynamic threshold voltage adjustments and that the predicted TID from ions calculated by Monte Carlo simulations overestimates actual TID due to unaccounted charge yield effects. In conclusion, this research enhances the understanding of Ga2O3 MOSFETs' performance in harsh radiation environments, providing insights for the design of robust electronic devices for space and nuclear applications.

MOSFET↗

Proton Effects and Test Issues for Satellite Designers

Microelectronic and photonic systems in the natural space environment are bombarded by a variety of charged particles including electrons, trapped protons, cosmic rays, and solar particles (protons and other heavy ions). These incident particles cause both ionizing and non-ionizing effects when traversing a device, and the effects can be either transient or permanent. The vast majority of the kinetic energy of an incident proton is lost to ionization, creating the single event effects (SEES) and total ionizing dose (TID) effects. However, the small portion of energy lost in non-ionizing processes causes atoms to be removed from their lattice sites and form permanent electrically active defects in semiconductor materials. These defects, i.e., "displacement damage," can significantly degrade device performance. In general, most of the displacement damage effects in the natural space environment can be attributed to protons since they are plentiful and extremely energetic (and therefore not readily shielded against). For this reason, we consider only proton induced displacement damage in this course. (Nevertheless, we identify solar cells as an important example of a case where both electron and proton damage can be important since only very light shielding is feasible.) The interested reader is encouraged to explore the three previous NSREC and RADECS short courses which also treat displacement damage issues for satellite applications. Part A of this segment of the short course introduces the space environment, proton shielding issues, and requirements specifications for proton-rich environments. In order to exercise the displacement damage analysis tools for on-orbit performance predictions, the requirements document must provide the relevant proton spectra in addition to the usual total ionizing dose-depth curves. Ion-solid interactions and the nature of the displacement damage they generate have been studied extensively for over half a century, yet they still remain a subject of investigation. In this section, a description of the mechanisms by which displacement damage is produced will be followed by a summary of the major consequences for device performance in a space environment. Often the degradation of a device parameter can be characterized by a damage factor (measured in a laboratory using monoenergetic protons) that is simply the change in a particular electrical or optical parameter per unit proton fluence. In addition, we will describe the concept of a non-ionizing energy loss rate (NIEL) which quantifies that portion of the energy lost by an incident ion that goes into displacements. It has been calculated as a function of proton energy, and is analogous to (and has the same units as) the linear energy transfer (LET) for ionizing energy. We will discover that, to first order, the calculated NIEL describes the energy dependence of the measured device damage factors. This observation provides the basis for predicting proton induced device degradation in a space environment based on both the calculated NIEL and relatively few laboratory test measurements. The methodology of such on-orbit device performance predictions will be described, as well as the limitations. Several classes of devices for which displacement damage is a significant (if not the dominant) mode of radiation induced degradation will be presented.

Marshall, Cheryl J.↗

Proton Effects and Test Issues for Satellite Designers: Displacement Effects - Section 4

Microelectronic and photonic systems in the natural space environment are bombarded by a variety of charged particles including electrons, trapped protons, cosmic rays, and solar particles (protons and other heavy ions). These incident particles cause both ionizing and non-ionizing effects when traversing a device, and the effects can be either transient or permanent. The vast majority of the kinetic energy of an incident proton is lost to ionization, creating the single event effects (SEES) and total ionizing dose (TID) effects described in section IVA. However, the small portion of energy lost in non-ionizing processes causes atoms to be removed from their lattice sites and form permanent electrically active defects in semiconductor materials. These defects, i.e., "displacement damage," can significantly degrade device performance. In general, most of the displacement damage effects in the natural space environment can be attributed to protons since they are plentiful and extremely energetic (and therefore not readily shielded against). For this reason, we consider only proton induced displacement damage in this course. (Nevertheless, we identify solar cells as an important example of a case where both electron and proton damage can be important since only very light shielding is feasible.) The interested reader is encouraged to explore the three previous NSREC and RADECS short courses [Srou88a, Summ92, Hopk97] which also treat displacement damage issues for satellite applications. Part A of this segment of the short course introduces the space environment, proton shielding issues, and requirements specifications for proton-rich environments. In order to exercise the displacement damage analysis tools for on-orbit performance predictions, the requirements document must provide the relevant proton spectra in addition to the usual total ionizing dose-depth curves.

Marshall, Cheryl J.↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

Impact of 12-nm FinFET Technology Variations on TID Effects: A Comparative Study of GF 12LP and 12LP+ at the Transistor Level

Here, this article presents a comparative analysis of total ionizing dose (TID) response in GlobalFoundries’ (GF) 12 low-power (LP) and 12LP+12-nm bulk fin field effect transistor (FinFET) technologies using 10-keV X-rays. Our findings show that 12LP+ n-type transistors demonstrate higher sensitivity to TID degradation of the off-state leakage drain current compared to 12LP. Data indicate that for both 12LP and 12LP+, transistors with higher threshold voltages (VTs) exhibit lower off-state drain-source leakage postirradiation compared to transistors with lower VTs. Data consistently show that transistors with fewer fins per transistor show superior TID tolerance, in both 12LP and 12LP+ technologies. Lower VT transistors in both technologies display similar preirradiation leakage currents. On the other hand, higher VT transistors in 12LP+ show lower preirradiation leakage currents than those in 12LP, highlighting that the front-end-of-line of 12LP+ technology has been modified compared to 12LP. p-type devices in 12LP+ presented negligible degradation. Larger TID sensitivity in 12LP+ might be attributed to the implementation of dual-metal gate work functions, reduced halo doping, deeper source/drain (S/D) doping profiles, and/or 12LP+ having narrower fins compared to 12LP.

Dual-metal gate work functions↗

Total Dose Effects on Single Event Transients in Digital CMOS and Linear Bipolar Circuits

This presentation discusses the effects of ionizing radiation on single event transients (SETs) in circuits. The exposure of integrated circuits to ionizing radiation changes electrical parameters. The total ionizing dose effect is observed in both complementary metal-oxide-semiconductor (CMOS) and bipolar circuits. In bipolar circuits, transistors exhibit grain degradation, while in CMOS circuits, transistors exhibit threshold voltage shifts. Changes in electrical parameters can cause changes in single event upset(SEU)/SET rates. Depending on the effect, the rates may increase or decrease. Therefore, measures taken for SEU/SET mitigation might work at the beginning of a mission but not at the end following TID exposure. The effect of TID on SET rates should be considered if SETs cannot be tolerated.

Buchner, S.↗

Memory Technologies and Data Recorder Design

Missions, both near Earth and deep space, are under consideration that will require data recorder capacities of such magnitude as to be unthinkable just a few years ago. Concepts requiring well over 16,000 GB of storage are being studied. To achieve this capacity via "normal means" was considered incredible as recently as 2004. This paper is presented in two parts. Part I describes the analysis of data recorder capacities for missions as far back as 35 years and provides a projection of data capacities required 20 years from now based upon missions either nearing launch, or in the planning stage. The paper presents a similar projection of memory device capacities as baselined in the ITRS - the International Technology Roadmap for Semiconductors. Using known Total Ionizing Dose tolerance going back as far as a decade, a projection of total dose tolerance is made for two prime technologies out to the year 2028.

Strauss, Karl F↗

BioSentinel/Mars: Interplanetary Space Radiation Biosensor Experiment in Martian Transit on Mars 2020

Despite significant progress understanding biological radiation effects via terrestrial studies, no terrestrial source duplicates space’s unique radiation environment. Furthermore, no biological experiments have been conducted beyond low Earth orbit since Apollo. Understanding space’s fundamental biological effects requires overcoming these limitations. The BioSentinel 4U payload, under development for flight aboard Exploration Mission-1, measures biological responses to deep space radiation. Traveling to more than 1AU from Earth, BioSentinel/EM-1 will record DNA double-strand breaks (DSBs) repaired using a pathway common to humans and BioSentinel’s bioengineered yeast model organism, responding to as few as one biologically repaired DSB. The BioSentinel/Mars 4U instrument (6-8kg; 5-8W; 0.2-1MB/week) would include eighteen 16-well biosensor fluidic cards, activated biweekly during Mars 2020’s cruise phase, to provide a dose-dependent rate of DSB/repair. The instrument, which includes solid-state sensors for total ionizing dose and linear-energy-transfer spectra, addresses MEPAG SKG-B3 by simultaneously measuring both spectra and biological effects of space radiation. Biological measurements are rendered reliable by independent replicate experiments. The spatio-temporal uniformity of interplanetary galactic cosmic radiation makes BioSentinel/EM1 and BioSentinel/Mars approximate replicates, except for any major differences in solar particle events. Results will be compared to Earth and ISS controls to characterize the radiation/reduced-gravity parameter space by its biological impact.

BioSentinel↗

SRAM-based FPGA: high dose test methods using evaluation boards

We present low-cost and effective methods and results for high levels of Total Ionizing Dose testing performed on the Xilinx Kintex UltraScale (20nm) Field-Programmable Gate Array evaluation board using 60Co and 2 MeV electron sources.

Thorbourn, Dennis↗

The Effects of Low Dose-Rate Ionizing Radiation on the Shapes of Transients in the LM124 Operational Amplifier

Shapes of single event transients (SETs) in a linear bipolar circuit (LM124) change with exposure to total ionizing dose (TID) radiation. SETs shape changes are a direct consequence of TID-induced degradation of bipolar transistor gain. A reduction in transistor gain causes a reduction in the drive current of the current sources in the circuit, and it is the lower drive current that most affects the shapes of large amplitude SETs.

Buchner, Stephen↗