At least 145 records · Page 8

Integrating Electromagnetic Acoustic Transducers in a Modular Robotic Gripper for Inspecting Tubular Components

Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.

Materials Science↗

A Lizard-inspired Tube Inspector (LTI) Robot

This final report summarizes the research findings of the current project. This project is a collaboration between New Mexico State University (NMSU) as a lead (Recipient) and Arizona State University (ASU) as a Co-Recipient. Tubular structures are common components of boilers and heat exchangers in power plants. Over time, these components may suffer corrosion, cracks, and stress-corrosion cracks in either the body or the welded connections. A single tube leakage can cause an outage of several weeks. Regular inspection is a key safety factor when ensuring that power plants are maintained in reliable, operational condition. This inspection, however, is challenging, time-consuming, and in many cases impossible due to accessibility issues and safety concerns. Recent developments in robotic-based inspection can offer a great solution. Hard-to-reach places can be inspected without overhauling the unit, saving time and cost. Although several robots have been designed and implemented successfully for inspecting power plant components, in particular tubular structures, their mobility and flexibility are limited. Most of these robots use wheels for mobility which reduces their maneuverability of these robots. Moreover, they usually use magnets to attach to tubes which will not work on tubes with non-ferromagnetic materials. These robots usually carry measurement tools for a particular non-destructive testing (NDT) method such as ultrasound testing (UT) that requires a couplant to perform a point-by-point (scanning) inspection of the tubular structure. In this project, we developed a versatile lizard-inspired tube inspector (LTI) robot with embedded inspection sensing components for tube inspection which removes the need for point-by-point scanning of tube surface for crack and corrosion detection. Inspired by a “lizard”, the novelty of the current project is the integration of couplant-free ultrasound sensing and transmission, advanced data-driven defect detection and imaging, and friction-based mechanical mobility components in a single robot to eliminate a need for smooth surfaces and simple geometry for mobility and scanning. The LTI robot could replace the wheel-based approach with friction-based mobility to significantly increase the flexibility and maneuverability of the robot. The LTI robot can get into a power plant unit, such as a boiler, from a small area allowing it to access a component of interest for inspection (e.g., move on OD, curved and flat surfaces, non-ferromagnetic or ferromagnetic materials, and tubes with rough surfaces and complex geometries). Additionally, an advanced data-driven method using ultrasound data was pioneered to allow the robot to detect defects in the entire area between the robot’s multi-functional mobility system (grippers). Integrating a couplant-free ultrasound sensing in the robot’s grippers as well as using advanced data-driven methods allowed the LTI to detect defects in the entire cross-section of a tube using its grippers when stationary and when mobile.

20 FOSSIL-FUELED POWER PLANTS↗

Quantitative Analysis of Origin of Lithium Inventory Loss and Interface Evolution over Extended Fast Charge Aging in Li Ion Batteries

During the extreme fast charging (XFC) of lithium-ion batteries, lithium inventory loss (LLI) and reaction mechanisms at the anode/electrolyte interface are crucial factors in performance and safety. Determining the causes of LLI and quantifying them remain an essential challenge. We present mechanistic research on the evolution and interactions of aging mechanisms at the anode/electrolyte interface. We used NMC 532 /graphite pouch cells charged at rates of 1, 6, and 9 C up to 1000 cycles for our investigation. The cell components were characterized after cycling using electrochemical measurements, inductively coupled plasma optical emission spectroscopy, 7 Li solid-state nuclear magnetic resonance spectroscopy, and high-performance liquid chromatography/mass spectrometry. The results indicate that cells charged at 1 C exhibit no Li plating, and the increase of SEI thickness is the dominant source of the Li loss. In contrast, Li loss in cells charged at 9 C is related to the formation of the metallic plating layers (42%) the SEI layer (38.1%) and irreversible intercalation into the bulk graphite (19%). XPS analysis suggests that the charging rate has little influence on the evolution of SEI composition. The interactions between competing aging mechanisms were evaluated by a correlation analysis. In conclusion, the quantitative method established in this work provides a comprehensive analytical framework for understanding the synergistic coupling of anodic degradation mechanisms, forecasting SEI failure scenarios, and assessing the XFC lithium-ion battery capacity fade.

25 ENERGY STORAGE↗

Linear simulation of magnetohydrodynamic plasma response to three-dimensional magnetic perturbations in high-β P plasmas

In this work, we report the numerical analyses of linear magnetohydrodynamics (MHD) plasma response to applied three-dimensional magnetic perturbations (MPs) in a joint DIII-D/EAST collaboration on high-β P (poloidal beta) plasmas, utilizing the extended-MHD code M3D-C1, with the purpose of realizing a better understanding of the existing experiment in which the n=3 MPs were applied to such high-β P plasmas attempting to control large amplitude type-I ELMs. Such high-β P plasmas obtained at the DIII-D tokamak feature an upper-biased double null configuration, a high edge safety factor q 95 ~6.4, and a stable internal transport barrier (ITB) leading to relatively high core pressures. Single-fluid simulations show that the plasma response to n=3 MPs, including both non-resonant/kinking and resonant components, is significantly weaker than that to n=1 or 2 MPs. To survey the impact of q 95 on plasma response to applied MPs, the SEGWAY (Self-consistent Equilibrium Generating Workflow for AnalYsis) module, developed in the OMFIT integrated modelling framework, is employed to generate a series of equilibria with a wide range of q 95 while other key parameters including the normalized beta, electron density at pedestal top, and plasma shape are kept fixed. Compared to the vacuum response, single-fluid M3D-C1 simulations predict a much more significant decrease of resonant plasma response to the applied n=3 MPs at the maximum penetration radii as q 95 increases. In contrast to single-fluid simulation results showing resonant penetration occurs only near the pedestal top where the E×B toroidal rotation frequency is zero, two-fluid simulations show two comparable resonant penetrations locating near the pedestal top and the ITB foot, where the perpendicular electron rotation frequency is zero. Such resonant field penetration near the ITB foot may be responsible for the observed formation of a staircase structure in both electron density and temperature profiles and thereby a considerable deterioration of global plasma performance when MPs are applied in high-β P plasmas. Motivated by this numerical work, we provide some ideas for the future research, with the purpose of realizing effective ELM control in such high-β P plasmas on the DIII-D and EAST devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LDRD poster - Identifying the speciation of salt-based actinides in the presence of contaminants

Molten salt reactors (MSRs) are among the most promising Generation IV nuclear reactors. The salts used in these reactors exhibit a high affinity for moisture and oxygen, and heating does not eliminate the oxides that are formed. Additionally, due to the high operating temperatures, reactor parts experience pronounced corrosion, and the resulting corrosion products integrate into the fuel salt system. It is hypothesized that the speciation of f-elements in molten salts would change in the presence of oxides and corrosion products. These changes in local structure can alter the rheological properties, which are critical to the operational and safety parameters of the reactors. Therefore, an in-depth understanding of how corrosion products influence lanthanide/actinide speciation is crucial. To test this hypothesis, lanthanides (as surrogates for actinides) and actinide chlorides were mixed with oxides (such as nickel oxide and lithium oxide) and/or corrosion products (e.g., nickel chloride) and reacted in molten salts. The resulting phases were analyzed using techniques such as powder X-ray diffraction, Raman spectroscopy, UV-Visible spectroscopy, and nuclear magnetic resonance spectroscopy. In the presence of oxides, due to the high oxophilicity of f-elements, these elements capture oxygen from the oxides, forming lanthanide/actinide oxide or oxychloride phases. Specifically, with cerium chloride, the introduction of lithium oxide to the formation of various final products depending on the oxide concentration. At lower oxide concentrations, cerium oxychloride (CeOCl) in the +3 oxidation state was observed, while an increase in the oxide concentration led to the formation of cerium dioxide (CeO2), where cerium is in the +4 oxidation state. In contrast, with nickel oxide, CeOCl formation was consistently observed, regardless of the oxide concentration. This project successfully determined that the speciation of f-elements change in the presence of oxides and different oxides in molten salts result in different final products. When the influence of nickel chloride was examined, changes in f-element speciation were not observed. However, it reacted with lithium chloride to generate a lithium-nickel-chloride (Li6NiCl8) phase, which was also observed when nickel oxide was reacted. Computational models were developed to simulate the phases anticipated under experimental conditions.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

X-point effects on the ideal MHD modes in tokamaks in the description of dual-poloidal-region safety factor

The flux coordinates with dual-region safety factor (q) in the poloidal direction are developed in this work. The X-point effects on the ideal MHD modes in tokamaks are then analyzed using this coordinate system. Since the X-point effects mainly affect the edge region, the modes localized at the tokamak edge are particularly examined. Two types of modes are studied. The first is related to the conventional peeling or peeling-ballooning modes. The mode existence aligned with the local magnetic field in the poloidally core region as observed experimentally is confirmed. The X points are shown to contribute to a stabilizing effect for the conventionally treated modes with the surface-averaged q and with the tokamak edge portion truncated. The other is the axisymmetric modes localized in the vicinity of X points, which can affect the cross-field-line transport near the X points. The existence of axisymmetric modes points to the possibility of applying a toroidally axisymmetric resonant magnetic perturbation (RMP) in the X-point area for mitigating the edge localized modes, which can be an alternative to the current RMP design. The dual q description also has important implications for the existing non-axisymmetric RMP concept. It helps to understand why the RMP suppression of edge localized modes is difficult to achieve in the double-null tokamak configurations and points to the possibility of further improving the current RMP concept by considering the alignment to the local q.

Fourier analysis↗

Concept Design of Active Shielding for Dynamic Wireless Charging of Light-duty EV

Dynamic wireless charging of electric vehicles is a flexible and state of the art charging technology with the potential capability of enabling fully automated in-motion charging. With charging power increasing to more than 100 kW for light duty vehicles, electromagnetic field (EMF) emission becomes a critical challenge. Due to the high costs of ferrite materials, this paper proposes an active shielding solution with multiple canceling coils installed on the ground side to supplement ferrite passive shielding to ensure electromagnetic safety. Two canceling coils are designed on two sides of the ground side coil. The canceling coils are small in size and 180 degree opposite in phase to the ground coil. Simulation and modeling shows that the canceling coils can reduce EMF emission from 37.2 µT to 18.2 µT at 0.8 m during 100 kW operation with only 2.5% of ground side current flowing in the canceling coils. These results have been preliminarily verified by inductance measurements and magnetic field measurement at 1.1 m distance without canceling coils. By further increasing the canceling coils’ currents to 4%, EMF emission can also be mitigated at 200 kW, although the canceling coils’ shape, position, and phase angle can be further optimized to improve the three-dimensional field distribution.

25 ENERGY STORAGE↗

Stability of a tokamak plasma with diffuse toroidal rotation

The present work considers the stability of a high- $\beta$ , large aspect ratio, circular plasma with diffuse profiles for the safety factor and the angular toroidal frequency (López & Guazzotto, Phys. Plasmas , vol. 24, 032501). An application of the Frieman–Rotenberg formalism results in a system of scalar eigenmode equations whose coupling is retained at the plasma–vacuum transition but is disregarded across the plasma column, which is a standard practice. The solution technique consists of a multidimensional shooting method for the poloidal harmonics; robust initial guesses are constructed by solving the dispersion relation in the static scenario with vanishing magnetic shear. Flow shear appears as a high- $\beta$ toroidal contribution, and we illustrate its destabilizing influence on $n=1$ external kink modes in the presence of ideal and resistive walls. Internal resonances are avoided by means of the selection of appropriate equilibrium parameters. The stabilizing influence of a finite positive average magnetic shear is also exemplified.

Physics↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Measurements of the polarization of several instabilities in the DIII-D tokamak

Recently, a method to infer the polarization of modes with frequencies much less than the ion cyclotron frequency was published [X.D. Du et al., Phys. Rev. Lett. 132 (2024) 215101]. The method uses measurements of electron temperature and density fluctuations δTₑ and δnₑ at the same spatial position to infer the local ratio of “acoustic polarization,” |δϕ ∥ |/(|δϕ ∥ |+|δψ|), where δϕ ∥ is the effective parallel potential and δψ is related to the parallel magnetic vector potential A ∥ . This paper summarizes key formulas, with emphasis on their range of validity, and elaborates on the workflow required to infer the acoustic polarization from experimental data. The drift-acoustic polarization of ellipticity-induced, toroidicity-induced, and reversed shear Alfvén eigenmodes is nearly zero, as expected for modes with predominately shear-Alfvénic polarization. The polarization of beta-induced Alfvén eigenmodes contains an acoustic component that increases with poloidal wave number. “Low frequency modes,” (instabilities that appear transiently when the minimum of the safety factor qₘᵢₙ passes through rational values) have large and highly variable acoustic polarization. In both experiment and simulation, fishbones have non-zero acoustic polarization that increases as the mode chirps down in frequency.

Alfven eigenmode↗

Variable-spectrum mode control of high poloidal beta discharges

DIII-D experiments demonstrate that high pressure, broad current profile equilibria can be accessed in the high poloidal beta regime by optimizing the MHD mode control poloidal spectrum. A novel, variable spectrum (VS) magnetic feedback scheme implemented using the DIII-D internal non-axisymmetric coils (I-coils) facilitated access to reduced internal inductance $l$ i operation above the no-wall beta limit compared with both no feedback and fixed spectrum feedback. In addition, the VS feedback helped avoid beta collapses caused by marginally unstable resistive wall mode activity. The lower and upper I-coil rows were configured in two independent feedback loops, allowing the feedback field's poloidal spectrum to vary and track changes in the plasma mode structure as the edge safety factor q 95 varied from 11 to 6 during the discharges. The q 95 dependence of the measured phase difference between the lower and upper I-coil rows during VS feedback is qualitatively compatible with ideal MHD simulations of the least-stable plasma kink mode and with plasma response simulations that included kinetic modifications to ideal MHD. The VS feedback approach is a straightforward way to improve resilience to variations in mode structure that occur as plasma parameters change. The demonstrated expansion of the operating space to lower $l$ i is expected to improve the coupling of the plasma kink mode to external fields and beneficial wall eddy currents, and is compatible with high bootstrap fraction operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results from the Alfven Eigenmode Active Diagnostic during the 2019-2020 JET deuterium campaign

This paper presents results of extensive analysis of mode excitation observed during the operation of the Alfven Eigenmode Active Diagnostic (AEAD) in the JET tokamak during the 2019-2020 deuterium campaign. Six of eight toroidally spaced antennas, each with independent power and phasing, were successful in actively exciting stable MHD modes in 479 plasmas. In total, 4768 magnetic resonances were detected with up to fourteen fast magnetic probes. In this work, we present the calculations of resonant frequencies f0, damping rates \gamma < 0, and toroidal mode numbers n, spanning the parameter range f0 = 30 - 250 kHz, -\gamma = 0 - 13 kHz, and |n| < 30. In general, good agreement is seen between the resonant and the calculated toroidal Alfven Eigenmode frequencies, and between the toroidal mode numbers applied by the AEAD and estimated of the excited resonances. We note several trends in the database: the probability of resonance detection decreases with plasma current and external heating power; the normalized damping rate increases with edge safety factor but decreases with external heating. These results provide key information to prepare future experimental campaigns and to better understand the physics of excitation and damping of Alfven Eigenmodes in the presence of alpha particles during the upcoming DT campaign, thereby extrapolating with confidence to future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffusion behavior of lanthanide fission products in bcc Fe cladding: A first-principles study

Fuel-cladding chemical interaction poses significant challenges in nuclear reactors, where fission products generated from nuclear fuel interact with Fe-based cladding materials, potentially compromising their structural integrity. This study investigates the diffusion behavior of lanthanide fission products, Lanthanum (La), Cerium (Ce), Praseodymium (Pr), and Neodymium (Nd), within body-centered cubic (bcc) Fe cladding using the density functional theory, nudged elastic band method, and self-consistent mean field theory. Our results reveal significant vacancy binding energies, particularly with the 1st and 2nd nearest neighbors, which diminish beyond the 5th nearest neighbor, with La exhibiting the strongest binding affinity, followed by Nd, Ce, and Pr. The nudged elastic band calculations indicate significant high barriers for the dissociation of 1st nearest neighbor vacancy-solute pairs for all fission products. The tracer diffusion coefficients of these fission products were derived in an Arrhenius form, with a magnetic correction that accounts for the high-temperature paramagnetic state. The significant trapping effect of vacancies caused by a very dilute concentration of fission products reduces vacancy mobility, potentially leading to modifications in point defect supersaturation, void nucleation, and swelling under irradiation. These represent critical challenges for irradiated cladding materials. The tracer diffusion coefficients indicate that Nd diffuses the fastest, followed by La, Ce, and Pr. Furthermore, this study provides essential insights for understanding fission product transport in cladding materials and informs future design strategies to mitigate fuel-cladding chemical interaction, ultimately enhancing nuclear reactor safety and performance.

Diffusion↗

AI-Enabled Robotic NDE for Structural Damage Assessment and Repair

The aim of this paper is to develop the concept and a prototype of an intelligent mobile robotic platform that is integrated with nondestructive evaluation (NDE) capabilities for autonomous live inspection and repair. In many industrial environments, such as the application of power plant boiler inspection, human inspectors often have to perform hazardous and challenging tasks. There is a significant chance of injury, considering the confined spaces and limited visibility of the inspection environment and hazards such as pressurization and improper water levels. In order to provide a solution to eliminate these dangers, the concept of a new robotic system was developed and prototyped that is capable of autonomously sweeping the region to be inspected. The robot design contains systematic integration of components from robotics, NDE, and artificial intelligence (AI). A magnetic track system is used to navigate over the vertical steel structures required for examination. While moving across the inspection area, the robot uses an NDE sensor to acquire data for inspection and repair. This paper presents a design of a portable NDE scanning system based on eddy current array probes, which can be customized and installed on various mobile robot platforms. Machine learning methods are applied for semantic segmentation that will simultaneously localize and recognize defects without the need of human intervention. Experiments were conducted that show the NDE and repair capabilities of the system. Improvements in human safety and structural damage prevention, as well as lowering the overall costs of maintenance, are possible through the implementation of this robotic NDE system.

Materials Science↗

Turbulence suppression at extreme plasma densities on DIII-D and EAST

Recent high-poloidal-beta (high-βP) experiments on DIII-D and EAST have made coordinated breakthroughs for high confinement quality at high density near the Greenwald limit. Density gradient amplification of turbulence suppression at high βP can explain both of these achievements. Experiments on DIII-D have achieved Greenwald fraction (fGr = line-averaged density/Greenwald density) above 1 simultaneously with normalized energy confinement (H98y2) around 1.5, as required in fusion reactor designs but never before verified in tokamak experiments with the divertor configuration. A synergy between increased H98y2 and fGr is observed with strong gas puffing, due to the build-up of an internal transport barrier at large radius in the temperature and density channels. Transport simulations reveal that the favorable trend of reduced turbulent energy transport at higher density is only expected when increasing the density gradient at high local safety factor and high β, thus at high βP to ensure strong α-stabilization. These conditions are crucial to many conceptual designs for steady-state reactors. New experiments on EAST have nearly doubled the ion temperature at fGr ∼ 0.9, consistent with predict-first modeling results based on the same physics revealed from the DIII-D analysis. All previous EAST long-pulse H-modes have Ti ≪ Te near plasma axis. Transport modeling indicates that the profiles are limited by ion-temperature-gradient modes at mid-radius. The modeling also suggested potential solutions, including reducing magnetic shear, enhancing density gradients, and higher impurity concentration. Following this guidance, EAST experiments directly show a strong enhancement of Ti achieved with a combination of a second plasma current ramp-up, a density gradient increase, and a Zeff perturbation by a short pulse (100 ms) of impurity injection, as predicted by the earlier modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis

Modern microelectronics life-cycle and supply chain ecosystem bring multiple untrusted entities, which can compromise their integrity. A major integrity issue of microelectronics stems from piracy of intellectual properties (IP) and counterfeiting, which causes significant revenue loss to the semiconductor manufacturers. Further, these components often lead to compromised functionality, reliability, security, and safety of an electronic system. This paper presents secure information transmission and probing methods for verifying the integrity of digital integrated circuit (ICs) based on their electromagnetic (EM) near-field emissions and thereby protecting systems against counterfeit components. The proposed method has been tested on both high-level instructions executed by microprocessors or Systems-on-Chip (serving as examples of software), and also logic circuits within FPGA fabrics and ASICs (serving as examples of hardware). The authentication information required by each digital system is generated using a pseudo-random number generator circuit and securely transmitted via near-field magnetic emissions. The authorized party can probe these emissions using a near-field probe, process the acquired signals to improve the signal-to-noise ratio (SNR), and then recover the secure information through matched filtering. Experimental results from commercial SoCs are used to demonstrate the proposed technique. Methods for reducing EM interference during integrity verification of both FPGAs and ASICs are also described.

47 OTHER INSTRUMENTATION↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

Overview of the MAST Upgrade physics programme: testing novel concepts at low aspect ratio to inform future devices

The research programme performed on the Mega Amp Spherical Tokamak (MAST) Upgrade experiment has made significant advances in developing the physics understanding of low aspect ratio tokamaks in support of the operation of ITER and design of fusion powerplants. High performance plasma scenarios have been developed to facilitate a broad programme of experiments, in which confinement is constrained by the presence of m/n = 2/1 modes that cause substantial losses of fast ions. The onset of these modes coincides with the q = 2 surface residing in a local minimum in the toroidal current density profile. The maximum electron temperature at the pedestal top, T e,ped is limited with gas fuelling to ∼350 eV to maintain regular ELMs; higher T e,ped results in a transition to a non-stationary ELM-free regime. The operational space of spherical tokamaks has been expanded into small and ELM-free regimes. Strong shaping of the last closed flux surface can induce a transition from large to small ELMs, and ELM suppression with resonant magnetic perturbations has been observed for the first time in a low aspect ratio tokamak. Negative triangularity shaping has induced a transition from ELMy H-mode to a high-performance L-mode regime for the first time in a low aspect ratio tokamak. In studies of fast ion confinement, losses of fast particles due to Global Alfvén Eigenmodes have been identified. Interactions between fast ions generated by off-axis neutral beam injection and thermal neutrals can result in significant losses of fast ions. Experiments with on- and off-axis neutral beam injection exhibit a flux pumping mechanism, where the central safety factor is held to ∼1 in the absence of sawteeth. In studies of pedestal physics, it has been found that elevated main chamber neutral pressures result in an increase in the electron density and reduction in the temperature at the pedestal top. Advances in understanding plasma exhaust include the integration of a high-performance plasma core with detached outer divertors in the X-point target configuration. A newly commissioned lower divertor cryopump reduces the lower divertor neutral pressure by up to 50%, with minimal effect on the main chamber or upper divertor. New measurements and SOLPS-ITER simulations emphasise the importance of plasma–neutral interactions on divertor detachment in the conditions accessible in experiments. Real-time control of the ionisation front location in both divertor chambers independently has been demonstrated in double null experiments, enabled by the tightly baffled divertor chambers.