Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Wastewater Disposal Has Not Significantly Altered the Regional Stress State in Southern Kansas

Wastewater disposal is primarily responsible for the increased seismicity rate since ~2013 in southern Kansas. Previous work that used shear-wave splitting (SWS) in southern Kansas interpreted an ~90° temporal rotation in the fast polarization direction and attributed it to increased pore pressures resulting from fluid injection. However, this interpreted rotation coincided with a change in the stations used to make the SWS measurements. We investigate the temporal variability of fast azimuths in southern Kansas by making SWS measurements on earthquake families with similar source–receiver paths recorded on a stable local seismic network. We select high-quality SWS measurements by investigating the stability of results across 65 different frequency bands between 0.5 and 15 Hz. We find that the fast polarization direction in southern Kansas is relatively constant with an average east-northeast (~N79°E) orientation between 2014 and 2017. Our fast polarization measurements are primarily a reflection of the maximum principal horizontal stress direction (SHmax). We observe a slight spatial change in SHmax to the northeast (~N55°E) near the Nemaha ridge in Oklahoma. However, we do not observe any significant temporal rotation of SHmax or variation in delay time (i.e., crack density) in southern Kansas, contrary to the earlier study. The previously interpreted ~90° rotation may either be a reflection of a very local stress change or a misinterpretation of SWS results potentially due to the use of inconsistent source–receiver paths. Our SWS measurements cover the period of peak wastewater disposal and seismicity rates and suggest an absence of significant temporal rotations in the local anisotropy and stress orientations associated with wastewater disposal.

Geochemistry & Geophysics↗

Uncertainty Quantification in GADRAS Inverse Modeling

The Gamma Detector Response and Analysis Software (GADRAS) package includes an inverse modeling tool that is helpful in identifying characteristics of unknown radioactive materials. Traditionally, uncertainties in this analysis were derived solely from measurement data quality and the fit of synthetic spectra. This paper aims to rigorously quantify additional sources of uncertainty, focusing on uncertainties arising from measurements being analyzed, Detector Response Function (DRF) characterization, and DRF extrapolation. Applying these findings to the BeRPBall benchmark data set, we demonstrated the impact of these uncertainties on plutonium and polyethylene estimates. The results underscore the importance of incorporating diverse uncertainty sources to enhance the accuracy and reliability of GADRAS’s inverse modeling capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Addressing the dynamic nature of reference data: a new nucleotide database for robust metagenomic classification

Accurate metagenomic classification relies on comprehensive, up-to-date, and validated reference databases. While the NCBI BLAST Nucleotide (nt) database, encompassing a vast collection of sequences from all domains of life, represents an invaluable resource, its massive size—currently exceeding 10 12 nucleotides—and exponential growth pose significant challenges for researchers seeking to maintain current nt-based indices for metagenomic classification. Recognizing that no current nt-based indices exist for the widely used Centrifuge classifier, and the last public version currently available was released in 2018, we addressed this critical gap by leveraging advanced high-performance computing resources. We present new Centrifuge-compatible nt databases, meticulously constructed using a novel pipeline incorporating different quality control measures, including reference decontamination and filtering. These measures demonstrably reduce spurious classifications, as shown through our reanalysis of published metagenomic data where Plasmodium annotations were dramatically reduced using our decontaminated database, highlighting how database quality can significantly impact research conclusions. Through temporal comparisons, we also reveal how our approach minimizes inconsistencies in taxonomic assignments stemming from asynchronous updates between public sequence and taxonomy databases. These discrepancies are particularly evident in taxa such as Listeria monocytogenes and Naegleria fowleri, where classification accuracy varied significantly across database versions. These new databases, made available as pre-built Centrifuge indexes, respond to the need for an open, robust, nt-based pipeline for taxonomic classification in metagenomics. Applications such as environmental metagenomics, forensics, and clinical metagenomics, which require comprehensive taxonomic coverage, will benefit from this resource. Our work highlights the importance of treating reference databases as dynamic entities, subject to ongoing quality control and validation akin to software development best practices. This approach is crucial for ensuring accuracy and reliability of metagenomic analysis, especially as databases continue to expand in size and complexity.

59 BASIC BIOLOGICAL SCIENCES↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

Turbulence modeling to aid tidal energy resource characterization in the Western Passage, Maine, USA

Numerical models combined with field measurements are regularly used to characterize tidal energy resources at potential energetic sites. However, most existing works only focus on the tidal hydrodynamic characteristics, and turbulence parameters are often not reported because of the lack of high-quality turbulence measurements and the limitations of numerical models in resolving turbulent eddies. In this study, we used FVCOM - a hydrostatic primitive equation (HPE) model - to characterize the tidal energy resource in the Western Passage, Maine, USA, by taking care of the essential macro-scale turbulence properties. We observed an excellent model performance using the Mellor-Yamada Level 2.5 Turbulence Model; estimating the spatial and vertical distribution of the turbulent kinetic energy and intensity added a new perspective to the site ranking for tidal energy converter (TEC) deployments. In addition, we also examined the role of channel geometry and bathymetry, such as headlands and underwater sills, in enhancing turbulent eddies around potential TEC siting locations. Ultimately, the detailed analysis of the turbulent flow characteristics has changed the site-ranking results and demonstrated that the regional-scale HPE models could be used for the relative understanding of more or less turbulent sites for a refined resource assessment.

16 TIDAL AND WAVE POWER↗

Earthquake Nowcasting with Deep Learning

We review previous approaches to nowcasting earthquakes and introduce new approaches based on deep learning using three distinct models based on recurrent neural networks and transformers. We discuss different choices for observables and measures presenting promising initial results for a region of Southern California from 1950–2020. Earthquake activity is predicted as a function of 0.1-degree spatial bins for time periods varying from two weeks to four years. The overall quality is measured by the Nash Sutcliffe efficiency comparing the deviation of nowcast and observation with the variance over time in each spatial region. The software is available as open source together with the preprocessed data from the USGS.

Fox, Geoffrey Charles (ORCID:0000000310171391)↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Taxonomic and Functional Diversity of Aquatic Macroinvertebrate Assemblages and Water Quality in Rivers of the Dry Tropics of Costa Rica

One of Costa Rica’s driest areas is the province of Guanacaste, in the Pacific Northwest, with almost no rain during the dry season from November to April. Due to this marked seasonality, the area is covered by dry tropical deciduous forest, considered the most threatened and least known tropical ecosystem in this area. This study analyzes and characterizes the assemblages of aquatic macroinvertebrates in water bodies within the Tempisque basin. Biological water quality was measured using the BMWP′-CR index. Macroinvertebrate assemblages were analyzed using abundance, richness, and functional feeding group approaches (FFG). Partial least square (PLS) analyses were performed, and the relationships between environmental factors and macroinvertebrate assemblages are also discussed. Macroinvertebrate assemblages were dominated numerically by mayflies, caddisflies, flies, and beetles. The BWMP′-CR index showed varying biological water quality, ranging from “very bad” to “excellent,” depending on rainfall and site management. Results suggest that tropical Mesoamerican rivers contradict the “river continuum concept” because predators and scrapers displace shredders in numbers. On the other hand, the study area shows a notable high richness of the Coleoptera genera. The class Rhynchocoela (Nemertea) is reported for the first time in Central America. The results indicate that the dry forest river ecosystem shows staggering biodiversity despite the surrounding agricultural land use, probably because of their older origin concerning tropical rain forests in Central America.

54 ENVIRONMENTAL SCIENCES↗

RECON Label Quality Report

The final quality of any AI/ML system is directly related to the quality of the input data used to train the system. In this case, we are trying to build a reliable image classifier that can correctly identify electrical components in x-ray images. The classification confidence is directly related to the quality of the labels in the training data, which are used in developing the AI/ML classifier. Incorrect or incomplete labels can substantially hinder the performance of the system during the training process, as it tries to compensate for variations that should not exist. Image labels are entered by subject matter experts, and in general can be assumed to be correct. However, this is not a guarantee, so developing ways to measure label quality and help identify or reject bad labels is important, especially as the database continues to grow. Given the current size of the database, a full manual review of each component is not feasible. This report will highlight the current state of the “RECON” x-ray image database and summarize several recent developments to try to help ensure high quality labeling both now and in the future. Questions that we hope to answer with this development include: 1) Are there any components with incorrect labels? 2) Can we suggest labels for components that are marked “Unknown”? 3) What kind of overall confidence do we have in the quality of the existing labels? 4) What systems or procedures can we put in place to maximize label quality?

42 ENGINEERING↗

Environmentally Sound One-Step Solar Silicon From Natural Quartzite

This project aimed to demonstrate a new molten salt electrodeposition process to go straight from low-cost silica at $200/tonne ($40¢/kg Si basis) to polysilicon in a single step using less than 30 kWh/kg. This would eliminate the carbothermic reduction step and all direct greenhouse emissions, along with 90% of the energy. It would also eliminate the chemical hazards of chlorosilane handling which have resulted in multiple fatalities in the polysilicon industry – in Japan, the US and China. This project had the following major accomplishments: Stakeholder engagement indicated that the solar silicon market is very sensitive to price, provided quality is sufficient. The most important measure of silicon quality is not purity but carrier lifetime, as many impurities can reduce performance at concentrations too small to measure; Experiments set a baseline of current efficiency which is too low for commercial application (~3%), with electronic current ruled out as a mechanism for reduced current efficiency; A scale-up plant narrative narrative described a potential plant and formed the basis for the TEA components; TEA showed that current efficiency, large cell size, and zirconia membrane lifetime are key factors which determine capital and operating costs for the process.

14 SOLAR ENERGY↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic nondestructive evaluation of additively manufactured wear coatings

Here, this work pertains to the nondestructive evaluation of additively deposited coatings using ultrasound measurements. The specific objective was to evaluate using ultrasound surface wave measurements the quality of Stellite 21 coatings deposited on Inconel 718 substrates by the directed energy deposition (DED) additive manufacturing (AM) process. The surface wave speed and diffuse backscatter amplitude of the ultrasound waves were correlated with both cracking and warpage of the coating. This research is important, because, the integrity of DED-processed coatings currently requires a combination of destructive metallographic studies and X-ray computed tomography analysis, which are both expensive and time consuming. Instead of using a normal incidence configuration for the ultrasound measurements, the surface-wave approach allows the inspection of the near surface coating integrity. Three different frequencies were used to excite surface waves because each frequency has a different penetration depth. The signals obtained were used to quantify and compare the surface wave speed and surface wave-diffuse ultrasonic backscatter amplitude from five different DED-processed Stellite coated samples. Considering destructive metallurgical characterization as a reference, surface wave measurements were found to be effective for examining coating integrity. Further, the backscatter amplitude of the surface waves was correlated with the crack density and warpage. These flaws also change the stress state of the Stellite coating and consequently the surface wave propagation speed and its scattering behavior.

36 MATERIALS SCIENCE↗

Autonomous Tuning and Charge-State Detection of Gate-Defined Quantum Dots

Defining quantum dots in semiconductor-based heterostructures is an essential step in initializing solid-state qubits. With growing device complexity and increasing number of functional devices required for measurements, a manual approach to finding suitable gate voltages to confine electrons electrostatically is impractical. Here, we implement a two-stage device characterization and dot-tuning process, which first determines whether devices are functional and then attempts to tune the functional devices to the single or double quantum-dot regime. We show that automating well-established manual-tuning procedures and replacing the experimenter’s decisions by supervised machine learning is sufficient to tune double quantum dots in multiple devices without premeasured input or manual intervention. The quality of measurement results and charge states are assessed by four binary classifiers trained with experimental data, reflecting real device behavior. We compare and optimize eight models and different data preprocessing techniques for each of the classifiers to achieve reliable autonomous tuning, an essential step towards scalable quantum systems in quantum-dot-based qubit architectures.

Darulova, J↗