Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High efficiency Al/Sc-based multilayer coatings in the EUV wavelength range above 40 nanometers

In this Letter, we have developed new and highly efficient periodic multilayer mirrors Al/Sc, Al/Sc/SiC, and Mo/Al/Sc with optimized reflectance at wavelengths between 40 and 65 nm. We have reached record values in measured peak reflectance: 57.5% at 44.7 nm and 46.5% at 51 nm, with Al/Sc/SiC at near-normal incidence. Furthermore, to the best of our knowledge, we have achieved the largest reported bandwidth with Mo/Al/Sc at 57 nm and the narrowest bandwidth with Al/Sc at a 60 nm wavelength. These new and promising results demonstrate that Al/Sc-based multilayer coatings are excellent candidates for future generations of extreme ultraviolet (EUV) instruments for solar physics, EUV lasers, and attosecond science, in a wavelength range that has not been fully explored.

36 MATERIALS SCIENCE↗

Optimize electron beam energy toward in-situ imaging of large thick bio-samples with nanometer resolution

To optimize electron energy toward in-situ imaging large bio-samples up to 10-μm thickness with nanoscale resolution, we implemented an analytical model based on elastic and inelastic characteristic angles 1. This model can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As result, the optimal choice of the electron beam energy can be realized. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV, and the ultimate resolution could become worse with the increase of the sample thickness.

43 PARTICLE ACCELERATORS↗

Effect of Pore Connectivity on the Behavior of Fluids Confined in Sub-Nanometer Pores: Ethane and CO2 Confined in ZSM-22

The behavior of fluids under nano-confinement varies from that in bulk due to an interplay of several factors including pore connectivity. In this work, we use molecular dynamics simulations to study the behavior of two fluids—ethane and CO2 confined in ZSM-22, a zeolite with channel-like pores of diameter 0.55 nm isolated from each other. By comparing the behavior of the two fluids in ZSM-22 with that reported earlier in ZSM-5, a zeolite with pores of similar shape and size connected to each other via sinusoidal pores running perpendicular to them, we reveal the important role of pore connectivity. Further, by artificially imposing pore connectivity in ZSM-22 via inserting a 2-dimensional slab-like inter-crystalline space of thickness 0.5 nm, we also studied the effect of the dimensionality and geometry of pore connectivity. While the translational motion of both ethane and CO2 in ZSM-22 is suppressed as a result of connecting the pores by perpendicular quasi-one-dimensional pores of similar dimensions, the effect of connecting the pores by inserting the inter-crystalline space is different on the translational motion of the two fluids. For ethane, pores connected via inter-crystalline space facilitate translational motion but suppress rotational motion, whereas in the case of CO2, both types of motion are suppressed by pore connection due to the strong interaction of CO2 with the surface of the substrate.

Kummali, Mohammed Musthafa (ORCID:000000028082555X↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Effects of space vacuum and solar ultraviolet irradiation (254 nanometers) on the colony forming ability of Bacillus subtilis spores

Bacillus subtilis spores are highly resistant to harsh environments. Therefore, in the Apollo 16 Microbial Response to Space Environment Experiment (M191), these spores were exposed to space vacuum or solar ultraviolet irradiation, or both, to estimate the change of survival for terrestrial organisms in space. The survival of the spores was determined in terms of colony-forming ability. Comparison of the flight results with results of simulation experiments on earth applying high vacuum or ultraviolet irradiation, or both, revealed no remarkable difference. Simultaneous exposure to both these space factors resulted in a synergistic effect (that is, an ultraviolet supersensitivity). Therefore, the change of survival in space is assumed to depend on the degree of protection against solar ultraviolet irradiation.

Buecker, H.↗

Solar spectral radiance and irradiance at 225.2-319.6 nanometers

Mean absolute intensities (spectral radiance) over 0.1 nm intervals between 225.2 nm and 319.6 nm at disk center and near the limb of the sun (mu = 0.23 + or - 0.04) are derived from the high spectral resolution measurements published by Kohl, Parkinson, and Kurucz. The corresponding limb-to-center ratios and spectral irradiance values are provided. A comparison with existing measurements of solar spectral radiance and spectral irradiance for the most part shows agreement within the estimated error limits, although some narrow band variations may be outside experimental errors. The contribution to the solar constant of the 230-305 nm band is derived to be 19.7 W/square m + or - 12%.

Kohl, J. L.↗

Absolute oscillator strengths for 108 lines of Si I between 163 and 410 nanometers

Measurements of neutral silicon oscillator strengths (f-values) obtained by absorption and emission techniques have been combined using the numerical procedure of Cardon et al. (1979) to produce 108 f-values for the Si I lines between 163 and 410 nm. Beam-foil-lifetime measurements were employed to determine the absolute scale. The present measurements have uncertainties of about 0.07 dex (+ or - 16 percent) at the 1-sigma level of confidence. Good agreement is obtained between the results and previous data. The data also provide upper limits for the f-values of 22 other lines and information on the lifetimes for 36 levels in Si I.

Smith, Peter L.↗

Solar Spectrum (SOLSPEC) measurement from 180 to 3000 nanometers

The SOLSPEC experiment, planned for the Atmospheric Laboratory for Applications and Science (ATLAS 1) NASA mission, is described. The purpose of this experiment is the measurement of the absolute solar irradiances in the wavelength range from 180 to 3000 nm and the variabilities of the solar irradiances in this wavelength range. Measurements of the irradiances and variabilities are used in: (1) solar-terrestrial/planetary relationships, in particular aeronomy of the stratosphere and mesosphere; (2) climatoglogy; and (3) solar physics.

Thuiller, G.↗

Image processing enhancement of high-resolution TEM micrographs of nanometer-size metal particles

The high-resolution TEM detectability of lattice fringes from metal particles supported on substrates is impeded by the substrate itself. Single value decomposition (SVD) and Fourier filtering (FFT) methods were applied to standard high resolution micrographs to enhance lattice resolution from particles as well as from crystalline substrates. SVD produced good results for one direction of fringes, and it can be implemented as a real-time process. Fourier methods are independent of azimuthal directions and allow separation of particle lattice planes from those pertaining to the substrate, which makes it feasible to detect possible substrate distortions produced by the supported particle. This method, on the other hand, is more elaborate, requires more computer time than SVD and is, therefore, less likely to be used in real-time image processing applications.

Artal, P.↗

Formation of ozone by irradiation of oxygen at 248 nanometers

While Slanger et al. (1988) have reported that the 248-nm KrF laser radiation generates ozone from oxygen, despite this wavelength's exceeding of the conventionally accepted photodissociation threshold of 242.4 for the ground electronic state, the initiating mechanism for this ozone formation remains obscure. It is presently suggested that the initiating step is the absorption of the 248-nm radiation by O2. In a reply to the present authors, Slanger et al. indicate that their original experiment should have been performed by introducing pure O2 into a baked cell, with the start time defined by the unblocking of the 248-nm laser.

Freeman, D. E.↗

High-resolution absorption cross sections of carbon monoxide bands at 295 K between 91.7 and 100.4 nanometers

Theoretical descriptions of the abundance and excitation of carbon monoxide in interstellar clouds require accurate data on the vacuum-ultraviolet absorption spectrum of the molecule. The 6.65 m spectrometer at the Photon Factory synchrotron light source was used to measure photoabsorption cross sections of CO features between 91.2 and 100.4 nm. These data were recorded at a resolving power of 170,000, more than 20 times greater than that used in previous work.

Stark, G.↗

Fabrication of nanometer single crystal metallic CoSi2 structures on Si

Amorphous Co:Si (1:2 ratio) films are electron gun-evaporated on clean Si(111), such as in a molecular beam epitaxy system. These layers are then crystallized selectively with a focused electron beam to form very small crystalline Co/Si2 regions in an amorphous matrix. Finally, the amorphous regions are etched away selectively using plasma or chemical techniques.

Nieh, Kai-Wei↗