Search NASA⌕ Search

SEARCH · Search NASA

Results for “under voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Critical Insights into Solvent Choice for High-Voltage Organosulfur Electrolytes

Organosulfur electrolytes are promising candidates for enabling high-voltage cathodes due to their superior oxidative stability compared to conventional carbonate-based systems. However, their viscous nature and inability to passivate the anode necessitate the use of passivating agents and diluents to achieve meaningful charge/discharge rates. In this study, we investigate the use of cyclic fluorinated carbonates (CFCs) to form passivating interphases on electrode surfaces, aiming to optimize electrolyte performance in high-voltage systems. Electrolyte formulations containing 1.2 M LiPF 6 in a CFC:sulfone:1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropylether (TTE) mixture (2/5/3 V/V/V) were assessed in full-cell configurations with a LiNi 0.8 Mn 0.1 Co 0.1 O 2 (FCG-NMC) cathode and a 4.5 V upper cutoff potential. The results reveal that 3-3-3-trifluoropropylene carbonate (TFPC) combined with ethyl methyl sulfone (EMS) optimizes electrolyte performance, resulting in lower resistance buildup and reduced capacity loss compared to commercial electrolytes. We also explore the failure mechanisms of several carbonate/sulfone mixtures and identify key considerations for electrolyte compatibility in high-voltage systems. TFPC enhances cycling stability and lowers overall cell resistance, while fluoroethylene carbonate (FEC) formulations, despite higher ionic conductivity, fail to form adequate passivation layers, leading to rapid capacity loss. Additionally, EMS provides superior physical properties that avoid common failure modes seen with other sulfone solvents like methyl isopropyl sulfone and tetramethylene sulfone. Furthermore, this study underscores the importance of carefully selecting passivating carbonates and sulfone solvents to improve electrolyte performance and expand the viability of high-voltage electrolyte systems.

LiNi0.8Mn0.1Co0.1O2 cathode↗

Distributed Coordination of Networked Microgrids for Voltage Support in Bulk Power Grids

The increasing deployment of distributed energy resources (DERs) and microgrids (MGs) in power distribution systems has enabled the adjustment of reactive power consumption as seen at the substation, which can be used to provide voltage support for the bulk power system (BPS). Leveraging this new capability will provide greater resiliency to the power system as a whole. Here, the goal of this paper is to develop and compare three different algorithms, namely distributed optimal power flow, distributed consensus algorithm, and fully decentralized collaborative autonomy for unbalanced distribution systems for microgrid coordination. These algorithms use networked MGs to support the BPS voltage when a contingency at the bulk grid results in abnormally low voltages, which may be a precursor to voltage collapse. Our comparative analysis includes both qualitative and quantitative assessments of the three algorithms and a discussion of the trade-offs between the decentralized and distributed methods in normal and disrupted conditions. Each algorithm was evaluated on the modified IEEE 13-bus system and a real power distribution system at Chattanooga, Tennessee, that encompasses more than 4500 buses. Each algorithms excels differently and may be suited for different scenarios depending on the condition, operations, and priorities of the power and communication systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical Models of Frequency and Voltage in Large-Scale All-Inverter Power Systems

Low-order frequency response models for power systems have a decades-long history in optimization and control problems such as unit commitment, economic dispatch, and wide-area control. With a few exceptions, these models are built upon the Newtonian mechanics of synchronous generators, assuming that the frequency dynamics across a system are approximately homogeneous, and assume the dynamics of nodal voltages for most operating conditions are negligible, and thus are not directly computed at all buses. As a result, the use of system frequency models results in the systematic underestimation of frequency minimum nadir and maximum RoCoF, and provides no insight into the reactive power-voltage dynamics. This paper proposes a low-order model of both frequency and voltage response in grid-forming inverter-dominated power systems. The proposed model accounts for spatial-temporal variations in frequency and voltage behavior across a system and as a result, demonstrates the heterogeneity of frequency response in future renewable power systems. Electromagnetic transient (EMT) simulations are used to validate the utility, accuracy, and computational efficiency of these models, setting the basis for them to serve as fast, scalable alternatives to EMT simulation, especially when dealing with very large-scale systems, for both planning and operational studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Calculations in Secondary Distribution Networks via Physics-Inspired Neural Network Using Smart Meter Data

The increasing penetration of distributed energy resources (DERs) leads to voltage issues across distribution networks, necessitating voltage calculations by utilities. Electric model-free voltage calculation offers an enticing solution. However, most researches mainly focus on primary distribution networks ignoring secondary distribution networks and commonly overlook extreme voltage case calculations, which require the model’s extrapolation abilities. Here, in addressing the gaps, this paper presents a customized physics-inspired neural network (PINN) model, the structure of which is inspired by the derived coupled power flow model of primary-secondary distribution networks. To ensure precision and rapid convergence, a crafted training framework for the PINN model is proposed. The PINN’s “structure-mimetic” design enables superior extrapolation for unseen scenarios and enhances physical information awareness. We demonstrate this through two applications: hosting capacity analysis and customer-transformer connectivity. The effectiveness and advantages of the proposed PINN model are validated on two public testing systems and one utility distribution feeder model.

Distribution network↗

Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation↗

On Possible Arc Inception on Low Voltage Solar Array

Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 of all registered failures and anomalies, and comprised the most costly losses (25) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over coverglass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in coverglass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.

plasma interaction↗

On Possible Arc Inception on Low Voltage Solar Array

Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 percent of all registered failures and anomalies, and comprised the most costly losses (25 percent) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over cover-glass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in cover-glass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.

low voltage solar array↗

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE↗

Unveiling the High‐Voltage Reactivity and Gas Evolution With Aluminum‐Based Chloride and Oxychloride Catholytes in Solid‐State Sodium Batteries

All-solid-state sodium batteries (ASSBs) employing halide solid electrolytes (SEs) offer a cost-effective and energy-dense alternative to conventional liquid electrolyte systems. However, their high voltage (>4 V vs. Na/Na + ) performance remains limited by interfacial instability between the cathode active material (CAM) and the SE. We present here the electrochemical and interfacial behaviors of crystalline NaAlCl 4 and amorphous sodium–aluminum–oxychloride (NACO) SEs when combined with NaNi 0.5 Mn 0.5 O 2 cathode. While oxygen incorporation in NACO enhances ionic conductivity by nearly three orders of magnitude relative to NaAlCl 4 , it does not improve high-voltage cycling stability. Cells employing NACO exhibit accelerated capacity fade, increased cell impedance growth, and intrinsic oxygen evolution above 4.5 V vs. Na 3 Sn, as revealed by operando electrochemical mass spectrometry. In contrast, the NaAlCl 4 -based cells show no detectable gas release, underscoring their superior high-voltage stability and safety. Time-of-flight secondary-ion mass spectrometry confirms the formation of Al─O and Ni/Mn─Cl species, respectively, in the SE and CAM, indicating redox-driven anion exchange that contributes to kinetic hindrance of high-voltage phase transitions. The findings establish that while oxygen incorporation enhances ionic transport, it can compromise interfacial stability, suggesting pure chloride SEs may offer a more robust and intrinsically safer pathway for developing high-energy ASSBs.

25 ENERGY STORAGE↗

Hypochlorite Redox Chemistry Enables High-Voltage and High-Power Saltwater Batteries

Saltwater batteries (SWBs) are promising alternatives to lithium-ion batteries for large-scale stationary energy storage. However, the performance of conventional oxygen redox-based saltwater battery systems is often constrained by sluggish oxygen evolution and reduction reactions (OER/ORR) at the cathode, leading to low voltage efficiency and limited power density. Here, OER and ORR are replaced by hypochlorite-based redox reactions through the introduction of sodium hypochlorite into saltwater. Operando pH and dissolved oxygen measurements confirm that OER and ORR are minimized and that hypochlorite redox reactions dominate the cathode behavior. Owing to the higher operating potential and faster reaction kinetics, the hypochlorite-redox-based SWBs delivers a higher discharge voltage of 3.3 V and reduced charge-discharge voltage polarization to 0.66 V. Further improvement is achieved by adjusting the saltwater pH to near-neutral conditions, increasing the discharge voltage to 3.5 V and more than doubling the peak power. The hypochlorite redox environment also exhibits chemical stability with key cell components, including the solid electrolyte and cathode current collectors. Operation of series-connected cells and cells employing hard carbon anodes demonstrates scalability and compatibility with alternative anode materials. These results provide a strong foundation for next-generation SWBs targeting large-scale stationary energy storage applications.

Go, Wooseok [ORNL]↗

A Simplified Method for Predicting Shaker Voltage in IMMATs

Impedance Matched Multi-Axis Tests (IMMATs) can replicate in-service vibration induced stress more accurately than single axis shaker table tests as they can better match a part’s operational boundary conditions and excite it in multiple degrees of freedom simultaneously. Here, the shakers used in IMMATs are less powerful than shaker tables, so shaker force limits can be exceeded during tests if they are not placed adequately for the desired environment. The ability to predict shaker voltage and force before performing a test is, therefore, helpful in selecting shaker locations so that their limits are not exceeded. In this study, electrodynamic shakers were modeled as discrete electromechanical systems, and the shaker parameters were chosen to match experimentally obtained acceleration/voltage frequency response functions (FRFs). These models were coupled to a finite element model of the device under test (DUT) via dynamic substructuring, and the substructured model was demonstrated to accurately predict shaker voltage as well as the error in reproducing the environment at multiple accelerometer locations. A simple method called the FRF Multiplication method, in which the FRF of the substructured system is approximated as the product of two separate FRFs of the shaker and DUT respectively, was proposed and applied to the same system, yielding similar voltage and error predictions to those obtained using substructuring. Simple case studies were presented to explore the applicability of the proposed method, and it was demonstrated to have similar accuracy to the substructuring method in a range of cases. Additionally, we showed that while it was not possible to derive a unique model of the shakers from acceleration/voltage FRFs alone, the models that could be obtained were sufficient to predict test error almost perfectly and shaker voltage with less than 40 percent error.

42 ENGINEERING↗

Single-crystal NMC622 from combustion-assisted solid-state synthesis: Tunable particle size, voltage-dependent stability, and Li-ion diffusion

Cost-effective and scalable synthesis of single-crystal lithium–metal-oxide cathodes with controlled size and morphology remains challenging for advancing high-performance lithium-ion batteries. Here, we demonstrate a solution combustion–assisted solid-state method for producing single-crystal NMC622 with tunable particle size at various lithium stoichiometries. Structural and electronic characteristics were probed using synchrotron-XANES, EXAFS, XRD and XPS, confirming well-defined coordination environments and phase purity up to Li ≈ 1.3. The electrochemical behavior of LixNMC (x = 1.0 and 1.3) single crystals was evaluated across 2.8–4.3 V and 2.8–4.7 V windows to elucidate the effects of lithium content and operating voltage. At 2.8–4.3V, Li1.3NMC exhibits higher initial capacity due to its larger lithium inventory, while Li1.0NMC shows superior long-term retention driven by its larger crystal size and reduced structural distortion. Increasing the cutoff voltage to 4.7 V enhances the initial capacity of both compositions by 17–25%, but long-term capacity retention ultimately converges to values comparable to those at 4.3 V due to voltage-induced degradation, where Li+ diffusion constant remains lying ranging from 10−12 –10−11 cm2s−1. Overall, this study establishes a scalable combustion-assisted route for synthesizing tunable single-crystal NMC622 and highlights the interplay between lithium stoichiometry, particle size, and voltage window in governing cathode stability.

Roy, Subrata C [Jackson State University]↗

Mechanistic Study of Functional Electrolyte Solvents for High-Voltage Lithium Batteries

The pervasive use of Ni-rich cathode active materials, e.g., LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811), for high-energy-density Li-ion batteries (LIBs) has been hindered by rapid battery capacity decay when cycled with high charge cutoff voltages due to electrolyte decomposition in the conventional carbonate solvent-based electrolytes, oxidative parasitic side reactions at the electrolyte/cathode interface, and irreversible phase changes in the cathode active materials leading to dissolution of transition metals into the electrolytes. Various functional electrolyte solvents have been studied to tackle the above technical challenges, yet the roles of individual solvents in the performance of LIBs remain poorly understood. Here, in this study, we systematically investigate electrochemical performance mechanisms of fluorinated and organosilicon single solvents and cosolvents, for the first time, in high-voltage Li/NMC811 batteries, using electrochemical and analytical characterizations and density functional theory modeling. We observe that some unique combinations of the functional solvents can lead to exceptionally stable high-voltage cycle performance in the Ni-rich cathode-based LIBs. Our mechanistic study reveals that the synergistic effect of solvents plays a vital role in enabling electrochemical stability at both the Ni-rich cathode and the Li metal anode. Understanding the electrochemical performance mechanisms of functional solvents can greatly help in designing and formulating advanced electrolytes that enable the development of high-voltage, high-energy-density, long-cycle-life lithium batteries.

density functional theory modeling↗

Deciphering Chemical/Electrochemical Compatibility of Li 3 InCl 6 in 5.2 V High-Voltage LiCoO 2 All-Solid-State Batteries

Large interfacial resistance is a widely recognized impediment to the advancement of high-voltage, all-solid-state batteries. However, a comprehensive understanding of the fundamental cause behind the interfacial resistance between solid electrolytes and typical layered oxide cathodes has not yet been achieved. Here, we investigated the high-voltage stability of Li 3 InCl 6 and elucidated the underlying interfacial electrochemical reactions between LiCoO 2 and Li 3 InCl 6 . Further, the pairing of Li 3 InCl 6 with LiCoO 2 exhibited a superior capacity retention of 73.6% even at 5.2 V, much higher than 28.2% charged at 4.6 V in lithium-ion batteries after 70 cycles. The enhanced high-voltage stability of ASSBs is attributed to the stable interface formed between LiCoO 2 and Li 3 InCl 6 and the reinforced surface and bulk structure stability. On the other hand, the ultrahigh voltage still causes the partial decomposition of Li 3 InCl 6 and generates interfacial compounds such as InClO and cobalt and indium chlorides/oxides.

25 ENERGY STORAGE↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)↗