Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

CCD Detects Two Images In Quick Succession

Prototype special-purpose charge-coupled device (CCD) designed to detect two 1,024 x 1,024-pixel images in rapid succession. Readout performed slowly to minimize noise. CCD operated in synchronism with pulsed laser, stroboscope, or other pulsed source of light to form pairs of images of rapidly moving objects.

Janesick, James R.↗

New Research by CCD Scanning for Comets and Asteroids

Spacewatch was begun in 1980; its purpose is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDS) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 pm (approximately V+R+I with peak sensitivity at 0.7 pm). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. The area covered by each scan is 32 arcminutes in declination by about 28 minutes of time in right ascension. The image scale is 1.05 arcseconds per pixel. Three passes take about 1.5 hours to complete and show motions of individual objects over a one hour time baseline. The limiting magnitude is about 21.5 in single scans. CCD scanning was developed by Spacewatch in the early 1980s, with improvements still being made - particularly by bringing a new 1.8-m Spacewatch Telescope on line. In the meantime, we have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. Spacewatch had found a total of 150 Near-Earth Asteroids (NEAS) and 8 new comets, and had recovered one lost comet (P/Spitaler in 1993). Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 10,882 asteroids designated by the Minor Planet Center (MPC).

Gehrels, Tom↗

Test of CCD Precision Limits for Differential Photometry

Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 10(exp 5). Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

Robinson, L. B.↗

Test of CCD Precision Limits for Differential Photometry

Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 105. Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

Borucki, W. J.↗

Simulations of the STIS CCD clear imaging mode PSF

Detailed understanding of the properties of the point-spread function (PSF) of Space Telescope Imaging Spectrograph (STIS) imaging modes is necessary to separate real effects of geometrically complex astronomical sources, such as protoplanetary disks surrounding bright stars, from instrumental effects, such as scattering and diffraction. In order to investigate STIS imaging properties we have numerically simulated broadband stellar PSFs generated by STIS in CCD clear imaging mode, including the effects of the Lyot stop and the coronagraphic wedges. The input spectrum is a stellar model atmosphere of the appropriate spectral type, convolved with the pre-flight STIS CCD response function. The PSF modeler generates broadband PSFs by co-adding weighted monochromatic PSFs across the waveband.

Cornett, R. H.↗

Event Pileup in AXAF's ACIS CCD Camera

AXAF's high resolution mirrors will focus a point source near the optical axis to a spot that is contained within a radius of about two pixels on the ACIS Charge Coupled Devices (CCD) camera. Because of the small spot size, the accuracy to which fluxes and spectral energy distributions of bright point sources can be measured will be degrad3ed by event pileup. Event pileup occurs when two or more X-ray photons arrive simultaneously in a single detection cell on a CCD readout frame. When pileup occurs, ACIS's event detection algorithm registers the photons as a single X-ray event. The pulse height channel of the event will correspond to an energy E approximately E-1 + E-2...E-n, where n is the number of photons registered per detection cell per readout frame. As a result, pileup artificially hardens the observed spectral energy distribution. I will discuss the effort at the AXAF Science Center Lo calibrate pileup in ACIS using focused, nearly monochromatic X-ray source. I will discuss techniques for modeling and correcting pileup effects in polychromatic spectra.

McNamara, Brian R.↗

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Testing of a Commercial CCD Camera

The results are presented of the examination and testing of a commercial CCD camera designed for use by amateur astronomers and university astronomy laboratory courses. The characteristics of the CCD chip are presented in graphical and tabular form. Individual and averaged bias frames are discussed. Dark frames were taken and counts are presented as a function of time. Flat field and other images were used to identify and locate bad pixel columns as well as pixels which vary significantly from the mean pixel sensitivity.

Tulsee, Taran↗

The STIS CCD Spectroscopic Line Spread Functions

We characterize the spectroscopic line spread functions of the spectroscopic CCD modes for high contrast objects. Our long range goal is to develop tools that accurately extract spectroscopic information of faint, point or extended sources in the vicinity of bright, point sources at separations approaching the realizable angular limits of HST with STIS. Diffracted and scattered light due to the HST optics, and scattered light effects within the STIS are addressed. Filter fringing, CCD fringing, window reflections, and scattering within the detector and other effects are noted. We have obtained spectra of several reference stars, used for flux calibration or for coronagraphic standards, that have spectral distributions ranging from very red to very blue. Spectra of each star were recorded with the star in the aperture and with the star blocked by either the F1 or F2 fiducial. Plots of the detected starlight along the spatial axis of the aperture are provided for four stars. With the star in the aperture, the line spread function is quite noticeable. Placing the star behind one of the fiducials cuts the scattered light and the diffracted light, is detectable even out to 1OOOOA. When the star is placed behind either fiducial, the scattered and diffracted light components, at three arcseconds displacement from the star, are below lop6 the peak of the star at wavelengths below 6000A; at the same angular distance, scattered light does contaminate the background longward of 6000A up to a level of 10(exp -5).

Gull, T.↗

Modeling of Proton-Induced CCD Degradation in the Chandra X-Ray Observatory

Modeling results are presented for proton-induced degradation of charge-coupled devices (CCDs) used in the Advanced CCD Imaging Spectrometer instrument on the Chandra X-Ray Observatory. A methodology is described that provides insights regarding degradation mechanism and on-orbit performance for front-illuminated and back-illuminated CCDs Proton-induced changes in charge transfer inefficiency are modeled. The observed amount of on-orbit degradation can be accounted for using a proton spectrum at the CCD location that is reduced in magnitude by a factor of approx. 1E5 compared to the spectrum incident on the spacecraft.

Lo, D. H.↗

Deflection Measurements of a Thermally Simulated Nuclear Core Using a High-Resolution CCD-Camera

Space fission systems under consideration for near-term missions all use compact. fast-spectrum reactor cores. Reactor dimensional change with increasing temperature, which affects neutron leakage. is the dominant source of reactivity feedback in these systems. Accurately measuring core dimensional changes during realistic non-nuclear testing is therefore necessary in predicting the system nuclear equivalent behavior. This paper discusses one key technique being evaluated for measuring such changes. The proposed technique is to use a Charged Couple Device (CCD) sensor to obtain deformation readings of electrically heated prototypic reactor core geometry. This paper introduces a technique by which a single high spatial resolution CCD camera is used to measure core deformation in Real-Time (RT). Initial system checkout results are presented along with a discussion on how additional cameras could be used to achieve a three- dimensional deformation profile of the core during test.

Stanojev, B. J.↗

Failure Analysis of CCD Image Sensors Using SQUID and GMR Magnetic Current Imaging

During electrical testing of a Full Field CCD Image Senor, electrical shorts were detected on three of six devices. These failures occurred after the parts were soldered to the PCB. Failure analysis was performed to determine the cause and locations of these failures on the devices. After removing the fiber optic faceplate, optical inspection was performed on the CCDs to understand the design and package layout. Optical inspection revealed that the device had a light shield ringing the CCD array. This structure complicated the failure analysis. Alternate methods of analysis were considered, including liquid crystal, light and thermal emission, LT/A, TT/A SQUID, and MP. Of these, SQUID and MP techniques were pursued for further analysis. Also magnetoresistive current imaging technology is discussed and compared to SQUID.

Felt, Frederick S.↗

An Overview of the CBERS-2 Satellite and Comparison of the CBERS-2 CCD Data with the L5 TM Data

CBERS satellite carries on-board a multi sensor payload with different spatial resolutions and collection frequencies. HRCCD (High Resolution CCD Camera), IRMSS (Infrared Multispectral Scanner), and WFI (Wide-Field Imager). The CCD and the WFI camera operate in the VNIR regions, while the IRMSS operates in SWIR and thermal region. In addition to the imaging payload, the satellite carries a Data Collection System (DCS) and Space Environment Monitor (SEM).

Chandler, Gyanesh↗

Producing CCD imaging sensor with flashed backside metal film

A backside illuminated CCD imaging sensor for reading out image charges from wells of the array of pixels is significantly improved for blue, UV, far UV and low energy x-ray wavelengths (1-5000.ANG.) by so overthinning the backside as to place the depletion edge at the surface and depositing a thin transparent metal film of about 10.ANG. on a native-quality oxide film of less than about 30.ANG. grown on the thinned backside. The metal is selected to have a higher work function than that of the semiconductor to so bend the energy bands (at the interface of the semiconductor material and the oxide film) as to eliminate wells that would otherwise trap minority carriers. A bias voltage may be applied to extend the frontside depletion edge to the interface of the semiconductor material with the oxide film in the event there is not sufficient thinning. This metal film (flash gate), which improves and stabilizes the quantum efficiency of a CCD imaging sensor, will also improve the QE of any p-n junction photodetector.

Janesick, James R.↗

Front-illuminated CCD with open pinned-phase region and two-phase transfer gate regions

A front-illuminated CCD of relative high quantum efficiency (QE) and high charge transfer efficiency (CTE) utilizes an open-phase region for receiving photons and two-phase gate regions (.phi..sub.1 and .phi..sub.2) for transferring electrons collected in one pixel to the next. The open-phase region is implanted with additional n-type elements (phosphorus) in order to increase the potential of the CCD channel in the open-phase region for collection of electrons and additionally implanted with concentrated and very shallow p-type elements (boron) to pin the surface of the n-channel in the open-phase region to OV, while gate region .phi..sub.1 and .phi..sub.2 are biased to -3.5V and driven to +10V by a two-phase transfer clock. The open pinned-phase (OPP) region thus permits two-phase transfer clocking and optimum reception of photons during the integration periods between transfer clock pulses.

Janesick, James R.↗

CCD imaging sensor with flashed backside metal film

A backside illuminated CCD imaging sensor for reading out image charges from wells of the array of pixels is significantly improved for blue, UV, far UV and low energy x-ray wavelengths (1-5000.ANG.) by so overthinning the backside as to place the depletion edge at the surface and depositing a thin transparent metal film of about 10.ANG. on a native-quality oxide film of less than about 30.ANG. grown on the thinned backside. The metal is selected to have a higher work function than that of the semiconductor to so bend the energy bands (at the interface of the semiconductor material and the oxide film) as to eliminate wells that would otherwise trap minority carriers. A bias voltage may be applied to extend the frontside depletion edge to the interface of the semiconductor material with the oxide film in the event there is not sufficient thinning. This metal film (flash gate), which improves and stabilizes the quantum efficiency of a CCD imaging sensor, will also improve the QE of any p-n junction photodetector.

Janesick, James R.↗

CCD imaging sensors

A method for promoting quantum efficiency (QE) of a CCD imaging sensor for UV, far UV and low energy x-ray wavelengths by overthinning the back side beyond the interface between the substrate and the photosensitive semiconductor material, and flooding the back side with UV prior to using the sensor for imaging. This UV flooding promotes an accumulation layer of positive states in the oxide film over the thinned sensor to greatly increase QE for either frontside or backside illumination. A permanent or semipermanent image (analog information) may be stored in a frontside SiO.sub.2 layer over the photosensitive semiconductor material using implanted ions for a permanent storage and intense photon radiation for a semipermanent storage. To read out this stored information, the gate potential of the CCD is biased more negative than that used for normal imaging, and excess charge current thus produced through the oxide is integrated in the pixel wells for subsequent readout by charge transfer from well to well in the usual manner.

Janesick, James R.↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗