Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Radiation Aging of Cable Insulation Systems to Support Extension of Cable Electrical Assessment Techniques - CRADA 562 (Final Report)

Radiation aging (primarily gamma radiation) affects a small subset of the LV cable population based on a 40-year operation. Increasing plant operating life to 60 or 80 years will result in additional cables experiencing degradation, either from radiation or from combined thermal and radiation effects. Previous research work done by EPRI and other researchers focuses on electrical diagnostics of thermal effects. However, the electrical diagnostic response of the cable system to radiation aging is minimally understood. In order to study the electrical responses from XLPE and EPR cabling and correlate these responses with radiation dose and level of thermal exposure, gamma radiation testing was performed at Pacific Northwest National Laboratory (PNNL). This report covers the radiation testing performed at PNNL, which involved irradiation of 30-foot long cables and short witness samples. The cabling was irradiated, at room temperature, using cobalt-60 gamma-rays to intervals of 10 million rads (10 Mrads), for a maximum of 70 Mrads. The results can be used to determine cable conditions (extent of damage) more accurately and localize where the degradation exists along the length of the cable (axial location). These insights can provide operators with the options to focus repair, mitigation, or replacement efforts locally.

36 MATERIALS SCIENCE↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Report on RIA Relevant Modified Burst Testing of ATF Cladding Materials

The mechanical performance of accident-tolerant fuel (ATF) cladding candidates in light-water reactors (LWRs) must be similar to or better than that of current conventional nuclear fuel claddings to reduce dose to the public and ensure a that the core coolable geometry is maintained during a postulated reactivity-initiated accident (RIA) in light-water reactors (LWRs). During an RIA event, the rapid thermal expansion of nuclear fuel can deform the cladding once the fuel–cladding gap closes. In some cases, the pellet–cladding mechanical interaction (PCMI) can induce mechanical failure in ATF candidates. Thus, the mechanical response of ATF cladding must be investigated by mimicking the conditions of RIA and potentially performing Transient Reactor Test (TREAT) experiments to establish or verify the safety envelope. The work presented in this report investigated the failure behavior of as-received, hydrided, and chromium-coated (Cr-coated) Zircaloy-4 (Zry-4) cladding tube under strain-driven mechanical conditions, mimicking postulated RIA loading conditions. Mechanical testing was performed at 300°C via modified burst test (MBT) equipment with pulse width control previously developed under the Department of Energy’s (DOE’s) Advanced Fuel Campaign (AFC). The mechanical strains were determined using 2D digital image correlation (DIC) techniques. The base Zry-4 acquired by Cameco Inc. was in stress-relieved annealed (SRA) condition. Because of the observed large deformation of the cladding tubes, the failure strain definition was updated for the MBT, which can also be applied to other tube tests where significant bulging (out-of-plane deformation) is present. The failure strain was determined to be affected by the speed of the test or the RIA event. As the RIA-like event duration decreased from 75 to 15 ms, the failure strain decreased 5, 7 and 1% for as-received, hydrided, and Cr-coated specimens, respectively. Fractography on the Cr-coated specimens indicated the presence of two failure mechanisms: (i) crenulation at the outer surface of the coating due to the tensile tractional forces along with coatings grain microstructure and (ii) formation of critical defect at the coating/cladding interface that initiated coating rupture after severe plastic deformation of the Zry- 4 substrate. Based on the MBT results and fractography observations, performing mechanical property testing at high strain rates—in particular on Cr-coated tubes—and semi-integral TREAT experiments are required future efforts to ensure ATF cladding performance during transients. The testing recommended would also inform the development of long-term generalized cladding technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication of yeast engineered porous 13X adsorbent layers for CO 2 capture

This study investigates a novel environmentally friendly coating technique using yeast fermentation to obtain super porous Zeolite 13X adsorbent layers through freeze-drying technique for CO 2 capture applications. Several mass ratios of sugar to yeast were used to control the porosity and pore sizes in the adsorbent layer. A unique peeling process was integrated to obtain foamy, hollow structures to have deeper layer accessibility of adsorbent for adsorption applications. These coated adsorbent layers were experimentally characterized as a function of the mass ratio of sugar to yeast and adsorbent solid fraction. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and Fourier-transform infrared spectroscopy (FT-IR) are used to analyze the coated layers. Here, the void fraction for coated samples is found to vary between 0.48 and 0.56, making the samples applicable for adsorption applications. Adsorption performance experiments are performed to test the coated samples' performance compared to 13X powder. Due to their simplistic fabrication, cost-effectiveness, rapid pore formation, and high adsorption capacity, these porous 13X layers hold potential for large-scale fabrication and CO 2 capture applications.

Adsorbent coating↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Copper and bismuth-based sorbent characterization in simulated iodine off-gas streams

The effective capture of volatile radioiodine, a fission product present in used nuclear fuel (UNF), is of paramount importance for development of used fuel reprocessing schemes to prevent release of radioiodine during unit operations and to meet regulatory standards for air emissions. A well-studied method for iodine capture in off-gas streams is the use of silver-functionalized zeolite phases (AgZ), which exploit chemisorption of I to Ag. Advances into other Ag-functionalized materials, including aerogels and metal organic frameworks (MOFs), are underway [1]. Additional metals with the capability to chemisorb iodine, including Cu, Bi, and Sn, [1] are being evaluated as alternatives to Ag for potential applicability to iodine management in off-gas systems. The design of novel functionalized sorbents with Cu and Bi, including composites with metal particles embedded in PAN substrates [2] and composites with metal sulfides embedded in PAN [3], is an ongoing area of study for improved iodine capture. Previously reported work on novel PAN-based metal sorbents has provided the synthesis, characterization, and iodine capture efficiency of this new class of sorbent. Specifically, the metal sulfide PAN composites are found to be easy to produce and reproduce, as well as having a high iodine loading potential under static conditions [3]. Due to the favorable testing previously performed with metal sulfide PAN composites, further testing into the performance of these composites under gas streams containing I2(g) in combination with NO2(g) and H2O(g) is needed. Humid streams of NO2(g) may arise from dissolver off-gas streams, when used fuel is dissolved in HNO3(aq) [4]. NO2(g) has been found to reduce AgZ sorption capacity for I because of oxidation of Ag, the chemisorbing agent, to Ag2O [5]. It follows that performance evaluation of novel sorbents under highly oxidizing conditions such as NO2(g) streams is critical. Therefore, the objective of this study is to determine the effect of flowing NO2(g) and H2O(g) streams on iodine sorption capacity and sorbent performance. This work utilizes custom-built gas handling capabilities for sorbent exposure along with solid-state characterization techniques to assess the physical and chemical properties of sorbents before and after exposure.

copper, bismuth, iodine capture, iodine sorbent, p↗

Analytical and Performance-Based Evaluation Alternatives to Full-Scope, High-Fidelity Testbeds

One consequence the design and operational differences of advanced reactors is that integrated system validation (ISV) using full-scope, high-fidelity testbed might not be cost-justified or practical. The absence of traditional ISV may pose an issue for the conduct of safety evaluations since it may leave regulators without the information derived from this performance-based testing. The purpose of this research is to identify analytical and performance-based test and evaluation methods that are alternatives to full-scope, high-fidelity testbeds that have traditionally been used for ISV. We developed a method to test validation based on a multi-stage validation (MSV) framework. MSV is an approach to meeting validation objectives through incremental, successive validation activities beginning in the early stages of the design process and continuing through the later stages. MSV doesn't rely solely on late stage validation, rather it accommodates the use of a broad spectrum of analytical and performance-based information and a diversity of testbeds. In addition, MSV embraces the use of information from other types of evaluations and analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion Testing of Bubbler Materials for LAW Vitrification (Rev. 0)

This work involved crucible-scale corrosion tests using coupons of selected materials in the baseline glass formulations for the seven LAW Sub-Envelopes. The tests were performed with Inconel 690 and MA 758; per the Test Plan, selected tests were also performed with a proprietary high temperature alloy supplied by SRTC. Coupons of these materials were tested for their corrosion resistance to LAW baseline glasses in two test series: the first series was with a baseline glass only, the second series was with a baseline glass and an added salt layer.

36 MATERIALS SCIENCE↗

Composite coatings from polycarbosilane derived SiC and Al/SiC cermet active fillers as protective barriers against steel corrosion

Stainless steel is used throughout the world as a structural material. However, it undergoes corrosion damage when exposed to extremely corrosive media, such as the marine environment. An alternative to solve this problem lies in the development of coatings that can withstand extreme conditions but also be easily deposited with inherently corrosion-resistant materials such as silicon carbide (SiC). The present study shows a simple method to produce Al/SiC cermet powders by attrition milling. The resulting cermet powders with a metallic matrix and hemispherical morphology, were employed as fillers in polycarbosilane (PCS) solutions that were sprayed on A304 stainless steel substrates. Al/SiC composite coatings were produced after heating the sprayed suspensions at 700 °C for 1 h in Ar atmosphere. The resulting composite coatings exhibited low surface energies (< 35 mN/m), water contact angles of 53°, and adhesion strength of up to 30 MPa. Finally, corrosion tests were performed in a cyclic corrosion test chamber, showing that these coatings effectively reduced the corrosion rate of stainless steel by 87%, reaching corrosion rate values of 0.007 g/cm 2 year.

36 MATERIALS SCIENCE↗

Blind QC trend presentation

Blind testing is used to evaluate performance of the radiobioassay laboratory. DOE-STD-1112-2019 requires a radiobioassay program to perform blind testing at a documented frequency including accuracy, false positive, false negative, and sensitivity evaluations. INL trends accuracy determinations over time for bias, agreement, and precision. Trends have been identified for certain isotopes in urine and feces that have not been fully explained. This presentation will review those identified trends and discuss possible causes and solutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Excellent performance of 650 MHz single-cell niobium cavity after electropolishing

Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.

43 PARTICLE ACCELERATORS↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

Investigation of the Mechanical Degradation of Zinc-Based Cold Spray Coatings for Steel Pipelines

Internal corrosion in wet natural gas is a big challenge in the oil and gas industry due to corrosive constituents such as carbon dioxide (CO2), hydrogen sulfide (H2S), other forms of sulfur, and water in the gas stream. To mitigate internal corrosion, zinc-based cold spray coatings were designed for use in natural gas pipelines to increase the lifespan of the pipeline network. However, one of the requirements in designing internal coatings is the resistance of the coatings to mechanical forces applied on the pipeline's internal wall during pigging operations. These forces are primarily compressive and shear/friction forces. This study examines material properties that must be considered when evaluating mechanical considerations. To determine the viability of the developed coatings with respect to the shear/friction forces, the shear adhesion and wear resistance of the materials have been evaluated. Shear adhesion testing was performed with modified clevises to determine the shear stress required to cause adhesion failure at the coating/substrate interface. Scanning electron microscopy was utilized to characterize the interfaces after failure. Wear testing was performed on coatings and pipeline materials utilizing pin-on-drum testing. These tests display the stress limitations and wear that the coatings can tolerate from pigging.

mechanical degradation↗

Irradiation of UC1+x kernels using the MiniFuel vehicle: Microstructure, phase analysis, and initial post-irradiation examination

Uranium carbide is a candidate fuel form for a wide range of advanced reactors, including larger Generation IV reactors as well as small modular reactors and microreactors. However, its commercial deployment timeline faces challenges via traditional qualification approaches. To address this issue, an accelerated fission rate irradiation test was performed to collect basic fuel performance data to inform fuel performance models and potential future integral tests. Hyperstoichiometric UC (UC1+x) kernels were irradiated in the High Flux Isotope Reactor using the MiniFuel irradiation vehicle. The test matrix spanned two temperature regimes (700 °C and 800 °C) and burnup levels (1.8 % FIMA and 2.8 % FIMA). Between 21 and 63 kernels were tested at each unique temperature and burnup condition. As-fabricated microstructural analysis revealed a multiphase composition with UC, UC2, UC2−y, and U-C-O bearing phases for the irradiated kernels. Following irradiation, fission gas release, swelling, and microstructures were analyzed. Measured fission gas release was below 5 % for all irradiation conditions, reaching a maximum at the highest temperature and burnup condition. A binary swelling response was observed; the lower burnup and temperature conditions resulted in negligible swelling, but the higher burnup and temperature conditions produced significant anisotropic swelling and densification in a subset of kernels. The basic microstructural exams of kernels following irradiation were not capable of showing a correlation between kernels that exhibited excessive swelling and those that did not. Characterization of a subset of samples using the Advanced Photon Source and more detailed microstructural examination of unirradiated kernels revealed that a subset of kernels contained very high UC2 phase fractions. The anomalous swelling response is hypothesized to have been driven by this chemical variation. The results of this irradiation highlight the potential of accelerated fission rate irradiation testing to explore such behaviors and inform the development of fuel specifications.

Adorno Lopes, Denise [ORNL] (ORCID:000900023705987↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗