Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Data enhancement and analysis through mathematical deconvolution of signals from scientific measuring instruments

Mathematical deconvolution of digitized analog signals from scientific measuring instruments is shown to be a means of extracting important information which is otherwise hidden due to time-constant and other broadening or distortion effects caused by the experiment. Three different approaches to deconvolution and their subsequent application to recorded data from three analytical instruments are considered. To demonstrate the efficacy of deconvolution, the use of these approaches to solve the convolution integral for the gas chromatograph, magnetic mass spectrometer, and the time-of-flight mass spectrometer are described. Other possible applications of these types of numerical treatment of data to yield superior results from analog signals of the physical parameters normally measured in aerospace simulation facilities are suggested and briefly discussed.

Wood, G. M.↗

Attaching Copper Wires to Magnetic-Reed-Switch Leads

Bonding method reliably joins copper wires to short iron-alloy leads from glass-encased dry magnetic-reed switch without disturbing integrity of glass-to-metal seal. Joint resistant to high temperatures and has low electrical resistance.

Kamila, Rudolf↗

The Gravity-Probe-B relativity gyroscope experiment - Development of the prototype flight instrument

The Gravity-Probe-B relativity gyroscope experiment (GP-B) will measure the geodetic and frame-dragging precession rates of gyroscopes in a 650 km high polar orbit about the earth. The goal is to measure these two effects, which are predicted by Einstein's General Theory of Relativity, to 0.01 percent (geodetic) and 1 percent (frame-dragging). This paper presents the development progress for full-size prototype flight hardware including the gyroscopes, gyro readout and magnetic shielding system, and an integrated ground test instrument.

Turneaure, J. P.↗

Chaos in driven Alfven systems

The chaos in a one-dimensional system, which would be nonlinear stationary Alfven waves in the absence of an external driver, is characterized. The evolution equations are numerically integrated for the transverse wave magnetic field amplitude and phase using the derivative nonlinear Schroedinger equation (DNLS), including resistive wave damping and a long-wavelength monochromatic, circularly polarized driver. A Poincare map analysis shows that, for the nondissipative (Hamiltonian) case, the solutions near the phase space (soliton) separatrices of this system become chaotic as the driver amplitude increases, and 'strong' chaos appears when the driver amplitude is large. The dissipative system exhibits a wealth of dynamical behavior, including quasiperiodic orbits, period-doubling bifurcations leading to chaos, sudden transitions to chaos, and several types of strange attractors.

Hada, T.↗

Electromagnetic scattering from arbitrary shaped conducting bodies coated with lossy materials of arbitrary thickness

A simple and efficient numerical technique is presented to solve the electromagnetic scattering problem of coated conducting bodies of arbitrary shape. The surface equivalence principle is used to formulate the problem in terms of a set of coupled integral equations involving equivalent electric and magnetic surface currents which represent boundary fields. The conducting structures and the dielectric materials are modeled by planar triangular patches, and the method of moments is used to solve the integral equations. Numerical results for scattering cross sections are given for various structures and compared with other available data. These results are proved accurate by a number of representative examples.

Rao, Sadasiva M.↗

Analysis of a slot loaded microstrip disk antenna for circular polarisation

A method is presented to analyze a circular microstrip disk antenna loaded with a narrow, inclined slot at its center and fed by a coaxial probe. Making use of the exact dyadic Green's functions for a grounded dielectric slab due to electric and magnetic currents, Richmond's reaction integral equation in conjunction with the method of moments (Galerkin), a generalized h-parameter equivalent network for the loaded patch is obtained. An expression for the input impedance of a slot loaded microstrip patch is obtained from the equivalent parameters. The theoretical results are compared with the experiment.

Rao, Y. R.↗

Vertical-Bloch-Line Memory

Vertical-Bloch-line memory is developmental very-large-scale integrated-circuit block-access magnetic memory. Stores data in form of localized pairs of twists (VBL pairs) in magnetic field at edge of ferromagnetic domain in each stripe. Presence or absence of VBL pair at bit position denotes one or zero, respectively. Offers advantages of resistance to ionizing radiation, potential areal storage density approximately less than 1 Gb/cm squared, data rates approximately less than 1 Gb/s, and average access times of order of milliseconds. Furthermore, mass, volume, and demand for power less than other magnetic and electronic memories.

Katti, Romney R.↗

Rotary blood pump

A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J.↗

Full-Wave Analysis Of MMICs Using A Generalized Yee Algorithm

Improved method of temporal analysis of propagation of electro-magnetic waves in monolithic microwave integrated circuits (MMICs) implemented by generalized version of traditional Yee algorithm. Provides more accurate mathematical modeling for analysis and design of MMICs. Based on unstructured and otherwise irregular grids. Grids readily fitted to conductive and dielectric circuit elements having realistically complex three-dimensional shapes. Better for modeling important and geometrically complex phenomena like fringing fields.

Lansing, Faiza S.↗

Rotary Blood Pump

A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J., Jr.↗

Axial Pump

A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J., Jr.↗

Polar Hydra Data Analysis

The science activities are: 1) Hydra is still operating successfully on orbit. 2) A large amount of analysis and discovery has occurred with the Hydra ground data processing this past year. 3) Full interdetector calibration has been implemented and documented. This intercalibration was necessitated by the incorrect installation of bias resistors in the pre-acceleration stage to the electron channeltrons. This had the effect of making the counting efficiency for electrons energy dependent as well as channeltron specific. The nature of the error had no impact on the ion detection efficiency since they have a different bias arrangement. This intercalibration is so effective, that the electron and ion moment densities are routinely produced with a level of agreement better than 20%. 4) The data processing routinely removes glint in the sensors and produces public energy time spectrograms on the web overnight. 6) Routine, but more intensive computer processing codes are operational that determine for electrons and ions, the density, the flow vector, the pressure tensor and the heat flux by numerical integration. These codes use the magnetic field to sustain the quality of their output. To gain access to this high quality magnetic field within our data stream we have monitored Russell's web page for zero levels and timing files (since his data acquisition is not telemetry synchronous) and have a local reconstruction of B for our use. We have also detected a routine anomaly in the magnetometer data stream that we have documented to Chris Russell and developed an editing algorithm to intercept these "hits" and remove them from the geophysical analysis.

Scudder, J. D.↗

Relativistic Electron Response to the Combined Magnetospheric Impact of a Coronal Mass Ejection Overlapping with a High-Speed Stream: Van Allen Probes Observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. We present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. The energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

Magnetosphere↗

Design, Development, Implementation, and On-Orbit Performance of the Dynamic Ionosphere CubeSat Experiment Mission

Funded by the NSF CubeSat and NASA ELaNa programs, the Dynamic Ionosphere CubeSat Experiment (DICE) mission consists of two 1.5U (1.5 Unit) CubeSats which were launched into an eccentric low Earth orbit on October 28, 2011. Each identical spacecraft carries two Langmuir probes to measure ionospheric in-situ plasma densities, electric field probes to measure in-situ DC and AC electric fields, and a science grade magnetometer to measure in-situ DC and AC magnetic fields. Given the tight integration of these multiple sensors with the CubeSat platforms, each of the DICE spacecraft is effectively a sensor-sat capable of comprehensive ionospheric diagnostics. The use of two identical sensor-sats at slightly different orbiting velocities in nearly identical orbits permits the deconvolution of spatial and temporal ambiguities in the observations of the ionosphere from a moving platform. In addition to demonstrating nanosat-based constellation science, the DICE mission is advancing a number of groundbreaking CubeSat technologies including miniaturized mechanisms and high-speed downlink communications.

DICE↗

Net field-aligned currents observed by Triad

From the Triad magnetometer observation of a step-like level shift in the east-west component of the magnetic field at 800 km altitude, the existence of a net current flowing into or away from the ionosphere in a current layer was inferred. The current direction is toward the ionosphere on the morning side and away from it on the afternoon side. The field aligned currents observed by Triad are considered as being an important element in the electro-dynamical coupling between the distant magnetosphere and the ionosphere. The current density integrated over the thickness of the layer increases with increasing magnetic activity, but the relation between the current density and Kp in individual cases is not a simple linear relation. An extrapolation of the statistical relation to Kp = 0 indicates existence of a sheet current of order 0.1 amp/m even at extremely quiet times. During periods of higher magnetic activity an integrated current of approximately 1 amp/m and average current density of order 0.000001 amp/sq m are observed. The location and the latitudinal width of the field aligned current layer carrying the net current very roughly agree with those of the region of high electron intensities in the trapping boundary.

Sugiura, M.↗

Improved Writing-Conductor Designs For Magnetic Memory

Writing currents reduced to practical levels. Improved conceptual designs for writing conductors in micromagnet/Hall-effect random-access integrated-circuit memory reduces electrical current needed to magnetize micromagnet in each memory cell. Basic concept of micromagnet/Hall-effect random-access memory presented in "Magnetic Analog Random-Access Memory" (NPO-17999).

Wu, Jiin-Chuan↗

Toroidal-Core Microinductors Biased by Permanent Magnets

The designs of microscopic toroidal-core inductors in integrated circuits of DC-to-DC voltage converters would be modified, according to a proposal, by filling the gaps in the cores with permanent magnets that would apply bias fluxes (see figure). The magnitudes and polarities of the bias fluxes would be tailored to counteract the DC fluxes generated by the DC components of the currents in the inductor windings, such that it would be possible to either reduce the sizes of the cores or increase the AC components of the currents in the cores without incurring adverse effects. Reducing the sizes of the cores could save significant amounts of space on integrated circuits because relative to other integrated-circuit components, microinductors occupy large areas - of the order of a square millimeter each. An important consideration in the design of such an inductor is preventing magnetic saturation of the core at current levels up to the maximum anticipated operating current. The requirement to prevent saturation, as well as other requirements and constraints upon the design of the core are expressed by several equations based on the traditional magnetic-circuit approximation. The equations involve the core and gap dimensions and the magnetic-property parameters of the core and magnet materials. The equations show that, other things remaining equal, as the maximum current is increased, one must increase the size of the core to prevent the flux density from rising to the saturation level. By using a permanent bias flux to oppose the flux generated by the DC component of the current, one would reduce the net DC component of flux in the core, making it possible to reduce the core size needed to prevent the total flux density (sum of DC and AC components) from rising to the saturation level. Alternatively, one could take advantage of the reduction of the net DC component of flux by increasing the allowable AC component of flux and the corresponding AC component of current. In either case, permanent-magnet material and the slant (if any) and thickness of the gap must be chosen according to the equations to obtain the required bias flux. In modifying the design of the inductor, one must ensure that the inductance is not altered. The simplest way to preserve the original value of inductance would be to leave the gap dimensions unchanged and fill the gap with a permanent- magnet material that, fortuitously, would produce just the required bias flux. A more generally applicable alternative would be to partly fill either the original gap or a slightly enlarged gap with a suitable permanent-magnet material (thereby leaving a small residual gap) so that the reluctance of the resulting magnetic circuit would yield the desired inductance.

Lieneweg, Udo↗