ESD Test Apparatus for Soldering Irons

ESDA (Electrostatic Discharge Association) ESD STM 13.1-2000 requires frequent testing of the voltage leakage from the tip of a soldering iron and the resistance from the tip of the soldering iron to the common point ground. Without this test apparatus, the process is time-consuming and requires several wires, alligator clips, or test probes, as well as additional equipment. Soldering iron tips must be tested for electrostatic discharge risks frequently, and this typically takes a lot of time in setup and testing. This device enables the operator to execute the full test in one minute or less. This innovation is a simple apparatus that plugs into a digital multimeter (DMM) and the Common Point Ground (CPG) reference. It enables the user to perform two of the electrostatic discharge tests required in ESD STM 13.1-2000. The device consists of a small black box with two prongs sticking out of one end, two inputs on the opposite end (one of the inputs is used to connect the reference CPG to the DMM), and a metal tab on one side. Inside the box are wires, several washers of various materials, and assembly hardware (nuts and screws/bolts). The device is a passive electronic component that is plugged into a DMM. The operator sets the DMM to read voltage. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The voltage is read and recorded. The operator switches the DMM to read resistance. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The resistance is recorded. If the recorded voltage and resistance are below a number stated in ESDA ESD STM 13.1-2000, the test is considered to pass. The device includes all the necessary wiring internal to its body so the operator does not need to do any independent wiring, except for grounding. It uses a stack of high-thermal-resistance washers to minimize the heat transfer from the soldering iron to the wiring used to measure the resistance and voltages. This minimizes thermal error. The device allows very rapid execution of a test that is performed frequently.

Sancho, Jose↗

Scaling Properties of Algorithms in Nanotechnology

At the present time, several technologies are pressing the limits of microminiature manufacturing. In semiconductor technology, for example, the Intel Pentium Pro (which is used in the Department of Energy's ASCI 'red' parallel supercomputer system) and the DEC Alpha 21164 (which is used in the CRAY T3E) both are fabricated using 0.35 micron process technology. Recently Texas Instruments (TI) announced the availability of 0.25 micron technology chips by the end of 1996 and plans to have 0.18 micron devices in production within two years. However, some significant challenges lie down the road. These include the skyrocketing cost of manufacturing plants, the 0.1 micron foreseeable limit of the photolithography process, quantum effects, data communication bandwidth limitations, heat dissipation, and others. Some related microminiature technologies include micro-electromechanical systems (MEMS), opto-electronic devices, quantum computing, biological computing, and others. All of these technologies require the fabrication of devices whose sizes are approaching the nanometer level. As such they are often collectively referred to with the name 'nanotechnology'. Clearly nanotechnology in this general sense is destined to be a very important technology of the 21st century. The ultimate dream in this arena is 'molecular nanotechnology', in other words the fabrication of devices and materials with most or all atoms and molecules in a pre-programmed position, possibly placed there by 'nano-robots'. This futuristic capability will probably not be achieved for at least two decades. However, it appears that somewhat less ambitious variations of molecular nanotechnology, such as devices and materials based on 'buckyballs' and 'nanotubes' may be realized significantly sooner, possibly within ten years or so. Even at the present time, semiconductor devices are approaching the regime where quantum chemical effects must be considered in design.

Saini, Subhash↗

Analyses of Transistor Punchthrough Failures

The failure of two transistors in the Altitude Switch Assembly for the Solid Rocket Booster followed by two additional failures a year later presented a challenge to failure analysts. These devices had successfully worked for many years on numerous missions. There was no history of failures with this type of device. Extensive checks of the test procedures gave no indication for a source of the cause. The devices were manufactured more than twenty years ago and failure information on this lot date code was not readily available. External visual exam, radiography, PEID, and leak testing were performed with nominal results Electrical testing indicated nearly identical base-emitter and base-collector characteristics (both forward and reverse) with a low resistance short emitter to collector. These characteristics are indicative of a classic failure mechanism called punchthrough. In failure analysis punchthrough refers to an condition where a relatively low voltage pulse causes the device to conduct very hard producing localized areas of thermal runaway or "hot spots". At one or more of these hot spots, the excessive currents melt the silicon. Heavily doped emitter material diffuses through the base region to the collector forming a diffusion pipe shorting the emitter to base to collector. Upon cooling, an alloy junction forms between the pipe and the base region. Generally, the hot spot (punch-through site) is under the bond and no surface artifact is visible. The devices were delidded and the internal structures were examined microscopically. The gold emitter lead was melted on one device, but others had anomalies in the metallization around the in-tact emitter bonds. The SEM examination confirmed some anomalies to be cosmetic defects while other anomalies were artifacts of the punchthrough site. Subsequent to these analyses, the contractor determined that some irregular testing procedures occurred at the time of the failures heretofore unreported. These testing irregularities involved the use of a breakout box and were the likely cause of the failures. There was no evidence to suggest a generic failure mechanism was responsible for the failure of these transistors.

Nicolas, David P.↗

Explosive component acceptance tester using laser interferometer technology

Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

Wickstrom, Richard D.↗

Derivation of a tangent function using an integrated circuit four-quadrant multiplier

A tangent function generator is provided which utilizes input signals proportionate to the sine and cosine of a given angle. The equipment accomplishes a trigonometric manipulation which forms an output signal substantially independent of the input reference voltage but proportional to the tangent of the angle. The device uses a multiplier and operational amplifier.

Bregman, B. J.↗

Real-time synthetic aperture radar processing

Real-time acousto-optic SAR processors are described and experimentally demonstrated. SAR imaging is performed in one of the architectures by applying the signal to an acousto-optic device and correlating it with chirp signals recorded on an optical transparency by time integration on a CCD detector. In a different implementation, the imaging is preformed by interfering the light beams diffracted from two separate acousto-optic devices, one modulated the radar signal and the second by the reference chirp waveform.

Psaltis, D.↗

Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

Regan, Timothy F.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Improvement in Rayleigh Scattering Measurement Accuracy

Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.

Fagan, Amy F.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗

Open-Pinned-Phase Charge-Coupled Device

Acceptable quantum efficiency obtained without back illumination and back-side thinning. NEW CCD technology referred to as "open-pinned-phase" (OPP) invented to unite best attributes of multiphase and virtual-phase technologies. Delivers high front-side sensitivity in conjunction with ultralow-signal-level performance.

Janesick, James R.↗

RH1021BMH-10 Precision 10 V Reference Total Ionizing Dose Test Report

The purpose of this test was to validate the Analog Devices (ADI) RH1021BMH-10 flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for this flight lot with wafer lot number 769658.1 and lot date code (LDC) 1430A. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Casey, Megan↗

Penetrating transmission zeros in the design of robust servomechanism systems

In the design of a robust servomechanism system, it is well known that the system cannot track a reference signal whose frequency coincides with the transmission zeros of the system. This paper proposes a new design method for overcoming this difficulty. The controller to be used employs a sampler and holding device with exponential decay. It is shown that the transmission zeros of the discretized system can be shifted by changing the rate of the exponential decay of the holding device. Thus, it is possible to design a robust controller for the discretized system to track any reference signal of given frequency, even if the given frequency coincides with the transmission zeros of the original continuous-time system.

Wang, S. H.↗

Comparison of Orion Flywheel to Commercially Available Flywheel Device

INTRODUCTION: The chosen exercise device for the Orion Multi-purpose Crew Vehicle (MPCV) for Artemis missions is the Orion Flywheel (OFW), which was selected in 2017 from a pool of exercise devices. The Orion Flywheel is to be installed in the MPCV for its first use during the Artemis II mission and will be utilized for subsequent Artemis missions. The OFW provides the capability to perform both resistive and aerobic exercises while taking up a small volume and not requiring power. Aerobic exercise consists of rowing while resistive exercise includes the deadlift, harness squat, and deadlift high pull among others. The efficacy of the OFW as an exercise countermeasure to spaceflight deconditioning has not yet been fully evaluated. A future HRP-funded study using head-down tilt bed rest is planned to evaluate the efficacy of the OFW to mitigate aerobic and muscular deconditioning. The OFW, made by KBR, is a specialized device that poses high costs for purchase and maintenance. The aim of the study is to determine if a commercially available alternative could be used as a backup for the OFW during the bed rest study or as an alternative in other studies. This study seeks to compare the loading profile and mechanics of a commercial flywheel device (kBox Pro) with the three resistance settings of the OFW using a controlled, instrumented setup to validate its acceptability as a backup. METHODS: An experimental setup was designed to simulate human use of the OFW. Flywheel devices can have varied actuated inertial mass and strap length. The inertial mass refers to the flywheel itself or the object that spins as the result of the movement of the strap. The OFW has three gears actuated with a lever, with the low gear used for aerobic rowing and the medium and high gears used for resistance exercises. These gears correspond to increasing flywheel inertia, which corresponds to a certain number and sizes of inertial plates on a commercial flywheel. The kBox Pro has varied sizes of inertial discs that are installed to the external shaft of the device and can be configured to roughly match the inertia seen in the OFW per gear setting. The strap length can be adjusted to allow for different ranges of motion. The experimental setup allows for the simulation of rowing, harness squats, and deadlift high pulls with corresponding exercise strap lengths. All three OFW gears are to be tested, as well as multiple combinations of kBox discs. The setup was created using a system of pulleys and cables to minimize friction loss. The system is actuated through the dropping of a connected mass which, through the pulley system, pulls the strap of the exercise device upwards as if a human was exercising. A string potentiometer and tensile force transducer are used to measure strap displacement and strap force, respectively. The masses dropped are exercise chains that simulate the decrease in force observed throughout a typical exercise. As the chains are lowered to the ground, they begin to spool and therefore are no longer subjecting the exercise device’s strap to their load. This setup was designed to provide realistic loads and protect the OFW from damage, an important precaution because it’s the only available unit for research and ground operations. Data is to be collected across simulated exercises and with different strap lengths, with the same conditions collected on both the OFW and the kBox Pro. RESULTS: Data collection is ongoing for the kBox and the Orion Flywheel. CONCLUSIONS: Study results will inform if the OFW and a kBox Pro device can be deemed mechanically similar. Depending on the results, additional data collection may be required to assess the user experience between the devices. A key result of this study is a mechanical characterization of the OFW device, demonstrating the load and force profile using a repeatable test method. This data will guide next steps on potential kBox Pro modifications needed to produce a comparable exercise experience to the OFW.

Exercise↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

To support the eventual development of a nuclear thermal rocket engine, a state-of-the-art experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The test device simulates the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner as to accurately reproduce the temperatures and heat fluxes normally expected to occur as a result of nuclear fission while at the same time being exposed to flowing hydrogen. This project is referred to as the Nuclear Thermal Rocket Element Environment Simulator or NTREES. The NTREES device is located at the Marshall Space flight Center in a laboratory which has been modified to accommodate the high powers required to heat the test articles to the required temperatures and to handle the gaseous hydrogen flow required for the tests. Other modifications to the laboratory include the installation of a nitrogen gas supply system and a cooling water supply system. During the design and construction of the facility, every effort was made to comply with all pertinent regulations to provide assurance that the facility could be operated in a safe and efficient manner. The NTREES system can currently supply up to 50 kW of inductive heating to the fuel test articles, although the facility has been sized to eventually allow test article heating levels of up to several megawatts.

Emrich, William J., Jr.↗

X-ray polarimeters

The paper presents the theory, design, performance parameters, and statistical limitations of dispersive-crystal and Thomson-scattering devices as X-ray polarimeters for solar and extrasolar observations. With reference to the Bragg crystal polarimeter, the instrument parameters of the OSO-8 polarimeter are reported along with estimates of the minimum detectable polarization for several sources as derived from measured values for the integral reflectivities, the known spectra for a number of X-ray sources, and crystal panel geometry. For the Thomson-scattering polarimeter, values are given for the scattering efficiency for hydrogen and lithium as a function of photon energy and for the spectra of the two brightest X-ray sources: Sco X-1 and the Crab Nebula.

Silver, E. H.↗