Search NASASearch

SEARCH · Search NASA

Results for “National Criticality Experiments Research Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,690 records · Page 94

Wyoming Trails Carbon Hub (WyoTCH)

The Wyoming Trails Carbon Hub (WyoTCH) project completed a front-end engineering and design (FEED) study for a commercial-scale, open-access carbon dioxide (CO 2 ) transport pipeline in Wyoming under U.S. Department of Energy (DOE) Award DEFE0032347, funded through the Bipartisan Infrastructure Law Carbon Capture Technology Program and administered by the National Energy Technology Laboratory. The project’s approach of designing a multi-source, multi-destination pipeline, rather than a dedicated line serving a single project, would lower the barrier to entry for individual CO 2 projects. The projects would leverage Wyoming's concentrated industrial and power generation CO 2 sources, its existing CO 2 pipeline infrastructure, and its extensive CO 2 storage and utilization capacity. This is the project's final technical report.

01 COAL, LIGNITE, AND PEAT

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States

Natural Fiber Simulations and Analysis for Composites

As the U.S. government and the aviation industry strive to achieve net-zero carbon emissions by 2050, the Sustainable Manufacturing of Aircraft (SUMAC) project, supported by the Convergent Aeronautics Solutions (CAS) program of the National Aeronautics and Space Administration (NASA), aims to develop sustainably derived thermoplastic composites and manufacturing technologies for future aviation. A multidisciplinary team of experts drives this initiative through a collective effort. The team’s key focus areas are sustainably derived thermoplastic resins, natural fiber reinforcement, composite manufacturing, structural health monitoring, computational materials modeling, and systems analysis. This presentation will give an overview of the SUMAC project. Fiber-scale microscopy analysis characterized fiber cross sections finding that hemp and flax fibers are very deformable and non-circular (circularities of 0.2 were observed), and diameters range from submicron to 20 μm. Fiber shapes range from flattened, with aspect ratios Rlong/Rshort up to 5, to round, Rlong/Rshort =1. And Fiber core perimeters, which likely drives deformability, were calculated Pcore=7 μm. Explicit-fiber yarn simulations, parameterized from single-fiber measurements, resolved and identified slack as a cause for yarn strain-hardening tensile behavior. The bonded network model of PLA, PHA and PA11 resins captures tensile behavior, and can model an infused weave. Computational models of the weave unit cells matched the pattern (including plain, twill and triaxial braid), yarn ply (1to 2), and yarn twist from optical microscopy.

thermoplastic

Natural Fiber Simulations and Analysis for Composites

As the U.S. government and the aviation industry strive to achieve net-zero carbon emissions by 2050, the Sustainable Manufacturing of Aircraft (SUMAC) project, supported by the Convergent Aeronautics Solutions (CAS) program of the National Aeronautics and Space Administration (NASA), aims to develop sustainably derived thermoplastic composites and manufacturing technologies for future aviation. A multidisciplinary team of experts drives this initiative through a collective effort. The team’s key focus areas are sustainably derived thermoplastic resins, natural fiber reinforcement, composite manufacturing, structural health monitoring, computational materials modeling, and systems analysis. This presentation will give an overview of the SUMAC project. Fiber-scale microscopy analysis characterized fiber cross sections finding that hemp and flax fibers are very deformable and non-circular (circularities of 0.2 were observed), and diameters range from submicron to 20 μm. Fiber shapes range from flattened, with aspect ratios Rlong/Rshort up to 5, to round, Rlong/Rshort =1. And Fiber core perimeters, which likely drives deformability, were calculated Pcore=7 μm. Explicit-fiber yarn simulations, parameterized from single-fiber measurements, resolved and identified slack as a cause for yarn strain-hardening tensile behavior. The bonded network model of PLA, PHA and PA11 resins captures tensile behavior, and can model an infused weave. Computational models of the weave unit cells matched the pattern (including plain, twill and triaxial braid), yarn ply (1to 2), and yarn twist from optical microscopy.

thermoplastic

Machine Learning for Predicting Team Functioning in HERA Missions

Team functioning is integral to success in future long term space exploration missions. Proactively detecting declines in team functioning can mitigate conflict and ensure mission success. This project developed a speech-based artificial intelligence (AI) system that unobtrusively predicts degradation in team functioning, including performance and cohesion, in the Human Exploration Research Analog (HERA) Campaigns 4 and 5. The AI system conducted automated analysis of the prosodic (tone of voice) and linguistic (language content) components of speech, modeling interpersonal dynamics at both the turn-taking and day-wide levels. We investigated team functioning via observing structured interactions (i.e., multi-mission space exploration vehicle-extra vehicular activity [MMSEV-EVA], team interaction battery [TIB]) and unstructured interactions before the MMSEV-EVA task. We developed machine learning models to predict team functioning (objective task accuracy, self reported team efficacy and self reported team cohesion) by analyzing OpenSmile acoustic features, linguistic descriptors extracted via the linguistic inquiry and word count (LIWC) dictionary, and semantic embeddings. In the TIB, static models using logistic regression and random forests were not able to predict task accuracy, but predicted team efficacy and cohesion during both the decision making and relational tasks to a moderate level (60-70%). Majority voting on the individual turns to predict day long team efficacy further increased accuracies (70-80%). Finally, long short-term memory (LSTM) models showed the best performance across all variables (80-91%), including task performance. In the MMSEV-EVA, static models achieved an accuracy of 60% with majority voting, which increased to 80% through the incorporation of mission day as a variable, accounting for the learning effect. A key finding across both tasks was the "team-dependent" nature of these interactions; models achieved much higher accuracy when trained on prior days of the same team's data rather than attempting to generalize across entirely different teams, with even 1-2 days of prior data per team achieving 5-15% improvement over team-independent models. In addition, the incorporation of pre-task data from the same team also improves model performance, e.g., incorporating data from the decision-making task of the TIB, which preceded the relational task, improved the prediction of team efficacy and cohesion during the latter. We compared model performance when trained on machine-generated data compared to data that had been further corrected by human annotators. Overall, models trained on human-corrected data exhibited a modest improvement in performance, particularly when acoustic features were used. We found no significant correlation between word error rate (WER) and model accuracy (r(55) = -0.08, p = 0.51), but model’s accuracy was significantly higher for medium/high quality transcription (0.74 (SD = 0.48)) compared to the low-quality group (0.64 (SD = 0.36)) (t(63)=2.82, p = 0.006). Based on these, several design recommendation emerge, that could inform Standards at NASA. Models predicting team functioning should incorporate at least one to two days of historical interaction data, include brief pre-task discussions, and explicitly model temporal learning effects, especially for longer operational tasks. Minimum quality standards for automated speech-processing pipelines are needed, given the performance gains observed with manually corrected acoustic data. Finally, systems should leverage both acoustic features and language embeddings in complementary ways, with modality choices and fusion strategies tailored to mission context, task demands, and data quality requirements.

Shrivatsa Mishra

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

xEMU

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis

Trajectory Engineering with Modular Patched Conics for Entry Systems and TPS (TEMPEST)

Brief Presenter Biography (35 word limit): Bohdan Wesely is an Aerospace Engineer in the Entry Systems and Technology Division at Ames. He has worked on a variety of projects for NASA including integrated TPS (thermal protection system) flight hardware deliveries and testing services for commercial partners. Introduction: TEMPEST is a new trajectory analysis framework that is designed to fill the gap between dedicated flight mechanics tools and aerothermal and TPS sizing tools. The project started as an SJSU master’s thesis and has since evolved into a general conceptual design tool capable of studying a wide variety of entry problems. Development is ongoing in the Entry Systems and Technology Division at NASA ARC. Why TEMPEST: Space missions involving entry into a planetary atmosphere involve a series of unique requirements across multiple disciplines. Whether it is traditional entry descent and landing (EDL), or aerocapture, the vehicle must navigate to its target landing location or orbit state, and the TPS must protect the payload during entry. The design process typically involves iterative handoffs between various flight mechanics, flow solver, and material response level tools. During the early conceptual phase, a wide variety of feasible trajectories are simulated in a Monte Carlo scenario which broadly satisfy the mission or landing requirements. Next, computational fluid dynamics (CFD), direct simulation Monte Carlo (DSMC), and other flow solver analyses are performed at various key trajectory points to generate an aero-database, heating and TPS design requirements also emerge at this stage. At this point, with updated aerodynamics from the various flow solvers, trajectories can be re-run, this in turn can change the required freestream conditions for the CFD tools, and as a project progresses, these analyses converge, and uncertainty is reduced. However, there is always a “hand-off” occurring between two inherently coupled phenomena. Analysis Description: One of the goals with TEMPEST is to use a variety of first principles estimation methods coupled with an atmosphere model to predict vehicle aerothermodynamics across the entire flight regime while propagating a 3 or 6 degree of freedom (DoF) trajectory. Aerodynamics methods include modified Newtonian, Maxwell and Cercignani- Lampis-Lord (CLL) for continuum, transitional, and free molecular flow regimes. Aerothermodynamics include boundary layer and reference enthalpy methods, and Mutation++ for non-equilibrium chemistry modeling. TEMPEST is also capable of stitching multiple trajectory segments together to study mission scenarios like multi-pass aerocapture and aero-gravity assists. Most of the program is implemented in MATLAB using modern system objects, it relies on several C++ shared libraries for supporting tools like Gmsh, the Global Reference Atmospheric Model (GRAM), and Mutation++. The various first principles aerothermal estimation methods are discretized across either a structured axisymmetric panel mesh or an unstructured tri-mesh generated from an open-source tool such as Gmsh, this allows solutions on the same mesh to be compared across tools such as CB-Aero. CFD Coupling. A physics-aware, gaussian process CFD anchoring scheme is proposed to adjust the various first principles methods as a CFD database is populated. One goal for this anchoring module is to inform the project where CFD should be run. Full knowledge of the entire trajectory, atmosphere, and aerothermodynamics allows for easier identification of high sensitivity areas and uncertainty quantification. While the first principles effects are well known and proven accurate in existing tools such as CB- Aero and Cart3D, a physics aware CFD anchoring scheme increases tool credibility across a project lifecycle. Material Response Modeling. Correct TPS sizing is critical for optimizing mass for science payloads and ensuring mission success. The process typically involves a thermal analysis along the trajectory with surface heating environments as a boundary condition. Several design constraints are maximum bondline temperature and maximum recession with various margining techniques. The material response tool FIAT, developed out of NASA Ames, is currently being integrated into the TEMPEST environment. TPS recession, shape change, mass loss, and mass property alteration are all factors that can perturb an entry trajectory. For missions like Mars 2020, recession was minimal and was safely handled separately as a post process. For missions such as Jupiter Galileo with a high TPS mass fraction or asteroid entries, recession plays a major role. The proposed fully coupled scheme is to use an epoch-based approach where the trajectory integration is halted after a recession threshold, the energy balance and FIAT are solved at each panel, the mesh, aerodynamics, and mass properties are updated, and the trajectory continues. Several computational tradeoffs have been made during the development of TEMPEST to limit the cost of a single trajectory and preserve its utility as a conceptual, rapid iteration tool. Conclusion: Development of TEMPEST is ongoing and the project is still in its infancy. This talk aims to showcase its unique capabilities to support future NASA entry systems missions.

Bohdan O Wesely

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Draft ASME Code Case to qualify L-PBF 316H material for Section III, Division 5 applications

This report documents the AMMT program’s development and submission of a draft ASME Code Case to qualify Laser Powder Bed Fusion (L PBF) Type 316H stainless steel for Section III, Divi-sion 5 Class A and SM high temperature nuclear applications. It summarizes the technical basis, the comprehensive high temperature mechanical test database assembled between 2023–2026, and the proposed code language and qualification framework submitted to ASME. The work was co-ordinated across multiple national laboratories and leverages prior ASME efforts to integrate additive manufacturing into the Boiler & Pressure Vessel Code. The body of the report describes the experimental database and analysis supporting the Code Case: tensile, creep, fatigue, creep fatigue, and thermal aging tests collected from multiple additive manufacturing sites, machine types, and powder lots, with material processed by a solution anneal heat treatment. The dataset — including both full size and subsized specimens and tests oriented parallel and perpendicular to build direction — shows limited tensile anisotropy, tensile properties comparable to wrought 316H, creep strength within the scatter of wrought material, but markedly reduced creep ductility above about 650 °C associated with rapid σ phase formation in L PBF microstructures. The draft Code Case itself prescribes a staged qualification model (manufacturing process qualification, component qualification, and per build witness testing), treats L PBF components as equivalent to Type 316 weld metal for design and inspection, and requires mechanical, chemical, and metallographic controls tied to ASTM/ISO 52946. Key acceptance criteria include tensile tests within a 90% prediction interval of the AMMT dataset, a creep fatigue screening test adapted from ASME Section III, Division 5, Subsection HB, HBB 2800 but with the cycle acceptance reduced to 100 for L PBF material, and double volumetric inspection of production components. The report concludes that the present data support treating L PBF 316H as analogous to conventional fusion weld metal for Division 5 design and inspection, while highlighting important caveats: the σ phase driven loss of creep ductility above ~650 °C, preliminary indications of enhanced creep fatigue sensitivity in some lots, and remaining gaps in long term aging and additional cyclic testing. Recommended next actions include completing outstanding cyclic and long duration creep/aging tests on the solution annealed condition, supporting inclusion of the 316H chemistry and heat treatment in ASTM/ISO 52946, and continuing engagement with ASME and NRC during balloting and review to enable industry adoption.

Messner, Mark C. (ORCID:0000000200404385)

Preliminary Assessment of the Impact on the V-Band Oxygen Channels From Satellite Communication Uplinks

We calculate the percentage of time that an ATMS-like instrument [1] will be illuminated by the uplink beam of one of the proposed V-band communication system and estimate the damage resulting from such exposure. Using a combination of openly available information and educated guesses about the location and characteristics of the up/down link terminals, we constructed the ground segment of a hypothetical high-speed communication network. The space segment of the network was constructed from the orbital data of the existing Starlink constellation [2] of 6223 communication satellites (comsats) which is used as strawman to represent any other possible constellation of communication satellites. It is shown that without a very delicate balance of frequency allocations (science vs telecommunications), coupled with extremely steep and deep bandpass-defining filters, and strict adherence to the agreed limits (i.e. no out-of-band transmissions) the deployment of the telecommunication network leads to almost-complete loss of some important geophysical data. For the analysis we use the spectral characteristics of the ATMS instrument with the ephemeris for the NOAA-21 satellite [3]. The analysis is conducted for the USA and the simulation covers 8 consecutive days in July 2024. Effective and accurate microwave remote sensing of the atmosphere depends on the availability of interference-free spectrum windows at frequencies which are prescribed by physical processes [e.g. 4]. The family of resonant lines of the oxygen molecule near 60 GHz provides a unique opportunity to sample the vertical distribution of temperature and density from space, and it has been exploited for weather and climate studies from polar-orbiting satellites since 1978 (MSU on TIROS-N [5]). It remains a staple in the payloads operated by Russia, China, USA, Japan, France, India, UK, Ukraine [6] which are built around a common blueprint: a few wide-band (hundreds of MHz) channels around 50 GHz to sample the atmosphere and the surface while several more channels with high spectral resolution (few MHz) sample the individual resonant lines. Accurate retrieval of the environmental parameters depends upon the data provided by both sets of channels, and the their location in frequency space is not arbitrary and cannot be altered at will [7, 8]. The introduction of 5G technology in 2019 has driven telecommunication companies to request more bandwidth to be dedicated to their devices. This additional bandwidth is only available in spectral regions traditionally reserved for environmental and astrophysical research, such as the V-band between 50 and 60 GHz for up/downlink between satellites in low-earth orbits and terminals connected to fiberoptics network for distribution to high-speed local internet services. The power broadcast by the uplink communication leg is many orders of magnitude greater than the natural thermal signal emitted from the Earth scene. If the ground antenna were to perfectly align with the passive instrument’s antenna, the spaceborne receiver would suffer permanent, irreparable damage. While a direct boresight-to-boresight conjunction is extremely unlikely (even with a large constellation of satellites the fraction of the celestial sphere occupied by the satellites remains minuscule) the finite size of the ground station’s antenna beam in the sky suggests that the ATMS will be in the near background (as seen from the ground station) of one of the communication satellites and will be illuminated by either the main lobe or the near sidelobes of the uplink antenna more often than it is desirable. For our analysis we first calculate the position of the ATMS with respect to each of the ground stations at a resolution of 0.2 sec, then calculate the position of each of the comsats which are at least 25 deg above the station’s local horizon; finally we calculate the angle between the line-of-sight of the ATMS and the line-of-sight of the comsat. We assume that the gain pattern of the ground station is circularly symmetric; the angle-off-station-boresight then provides an attenuation of the uplink power which we use to assess the likely effect upon the passive instrument’s operations. We assume that each ground station can communicate with all the comsats in its field of view; this implies that, on average, a ground station can engage with 46 comsats simultaneously. The analysis is repeated for the case when the uplink broadcast within the ATMS passive channels (in-band scenario) and for the case when the uplink is limited to frequencies adjacent to the ATMS channels (out-of-band scenario). The antenna of the ground station is modelled as having a HPBW (Half-Power Beam Width) of 0.16 deg and EIRP (Equivalent Isotropic Radiated Power) of 70 dBW. We account for the geometric dissipation of the signal caused by the satellite orbital altitude, the attenuation induced by atmospheric gasses at 51 GHz and the mismatch between the circular polarization of the ground-based transmitting antenna and the linear polarization of the satellite-borne receiving antenna. The damages on ATMS are estimated from bench-level measurement conducted at the ATMS’ manufacturer facilities [unpublished].

passive microwave

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI