Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks

The Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks program (DE-FC26-04NT42189), commonly referred to as the AES program, focused on areas that will primarily benefit fuel economy and improve heat rejection while driving over the road. The AES program objectives were to: (1) Analyze, design, build, and test a cooling system that provided a minimum of 10 percent greater heat rejection in the same frontal area with no increase in parasitic fan load. (2) Realize fuel savings with advanced power management and acceleration assist by utilizing an integrated starter/generator (ISG) and energy storage devices. (3) Quantify the effect of aerodynamic drag due to the frontal shape mandated by the area required for the cooling system. The program effort consisted of modeling and designing components for optimum fuel efficiency, completing fabrication of necessary components, integrating these components into the chassis test bed, completing controls programming, and performance testing the system both on a chassis dynamometer and on the road. Emission control measures for heavy-duty engines have resulted in increased engine heat loads, thus introducing added parasitic engine cooling loads. Truck electrification, in the form of thermal management, offers technological solutions to mitigate or even neutralize the effects of this trend. Thermal control offers opportunities to avoid increases in cooling system frontal area and forestall reduced fuel economy brought about by additional aerodynamic vehicle drag. This project explored such thermal concepts by installing a 2007 engine that is compliant with current regulations and bears additional heat rejection associated with meeting these regulations. This newer engine replaced the 2002 engine from a previous project that generated less heat rejection. Advanced power management, utilizing a continuously optimized and controlled power flow between electric components, can offer additional fuel economy benefits to the heavy-duty trucking industry. Control software for power management brings added value to the power distribution and energy storage architecture on board a truck with electric accessories and an ISG. The research team has built upon a previous truck electrification project, formally, 'Parasitic Energy Loss Reduction and Enabling Technologies for Class 7/8 Trucks', DE-FC04-2000AL6701, where the fundamental concept of electrically-driven accessories replacing belt/gear-driven accessories was demonstrated on a Kenworth T2000 truck chassis. The electrical accessories, shown in Figure 1, were controlled to provide 'flow on demand' variable-speed operation and reduced parasitic engine loads for increased fuel economy. These accessories also provided solutions for main engine idle reduction in long haul trucks. The components and systems of the current project have been integrated into the same Kenworth T2000 truck platform. Reducing parasitic engine loading by decoupling accessory loads from the engine and driving them electrically has been a central concept of this project. Belt or gear-driven engine accessories, such as water pump, air conditioning compressor, or air compressor, are necessarily tied to the engine speed dictated by the current vehicle operating conditions. These conventional accessory pumps are sized to provide adequate flow or pressure at low idle or peak torque speeds, resulting in excess flow or pressure at cruising or rated speeds. The excess flow is diverted through a pressure-minimizing device such as a relief valve thereby expending energy to drive unnecessary and inefficient pump operation. This inefficiency causes an increased parasitic load to the engine, which leads to a loss of usable output power and decreased fuel economy. Controlling variable-speed electric motors to provide only the required flow or pressure of a particular accessory system can yield significant increases in fuel economy for a commercial vehicle. Motor loads at relatively high power levels (1-5 kW, or higher) can be efficiently provided current from high-efficiency generators or batteries with system voltages in the range of 250 to 360 volts DC (VDC). In the previous project, the electric accessories could be powered from one of three sources: an AC voltage source ('shore power'), an on-board diesel generator (auxiliary power unit), or an ISG located in the flywheel housing and driven by the main engine. The electric accessories and power sources, including the ISG, have remained in place for the current upgrade of the research platform vehicle. In this project, more emphasis has been placed on determining the best way to use the ISG to power the vehicle and accessories, thereby yielding additional value from existing hardware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fidelity Requirements with Fast Transients from VSC-HVdc

Fast control afforded by power electronics in highvoltage direct current (HVde) systems, especially voltage-source converter (VSC) based HVde systems, needs to be carefully assessed to identify stability boundaries. While there are several averaged models of VSC-HVdc systems that have been studied with low bandwidth alternating current (ac) system models, there have been limited studies to show the need for high-fidelity models to understand the control interactions between different VSC-HVdc systems as well as with other grid components. In this paper, the fidelity of power electronics and connected grid components like transmission lines are identified based on defined use-cases to understand the stability and impact of the fast control afforded by VSC-HVdc systems. These results will be useful to understand the methods required to study control in VSC-HVdc systems.

Debnath, Suman↗

OLED Luminaire with Panel Integrated Drivers and Advanced Controls

For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecture has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.

47 OTHER INSTRUMENTATION↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier: Preprint

As inverter controls have become increasingly complex, power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves the desired inverter, a power amplifier, and a digital real-time simulator (DRTS) to control the simulated power system. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. The interface design for PHIL test beds has been previously examined in the literature, but many existing methods use older power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS rather than one preexisting in hardware. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and validated in hardware with a single 30-kW grid-following inverter.

DRTS↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Networked Control and Optimization for Widescale Integration of Power Electronic Devices in Residential Homes

Power electronics devices are emerging at residential houses, including electric vehicles, energy storage systems, solar photovoltaic systems, and variable-speed air conditioners. Little work has been done on scalable and end-to-end architectures for integrating and engaging large number of residential behind-the-meter assets to provide grid services. In this paper, a framework for integration of a demand management system, home energy management system, and residential smart inverters is presented. Full measured results of inverter response to control signals is also presented.

Starke, Michael↗

Dependability Assessment of Software for Safety Instrumentation and Control Systems

In its 2013 recommendations to the International Atomic Energy Agency (IAEA), the Technical Working Group on Nuclear Power Plant Instrumentation and Control (TWG-NPPIC) identified assessment and evaluation of software dependability as a topic of interest for IAEA Member States. To implement the recommendation of the TWG-NPPIC, the IAEA Scientific Secretary for the TWG initiated a consultancy activity in 2014 to develop a technical report describing a dependability assessment framework suitable for safety instrumentation and control (I and C) systems in nuclear power plants (NPPs). The development of the software dependability assessment report has involved three consultancy meetings at IAEA headquarters in Vienna, Austria. The conduct of these meetings allowed consultation among subject matter experts to generate consensus technical information that serves as the content of the report. The technical contributors consist of international experts from academia, industry, regulatory bodies and research organizations. In September 2014, a technical meeting was held in Daejeon, Republic of Korea, to present interim findings of the consultancy effort and to solicit input from representatives of IAEA Member States. The information and technical comments contributed during the technical meeting were addressed in subsequent development of the report. This paper gives an overview of key technical elements of the IAEA report. The IAEA report presents a framework by which a dependability assessment of safety software can be performed. The specified guiding principles provide the basis for establishing an assessment strategy and implementing the assessment process. The assessment framework provides a systematic, coherent structure within which to organize technical and process evidence to satisfy arguments in support of claims about software dependability properties. During the consultancy activity, the participating subject matter experts focused on high level principles, a structured approach, and identification of suitable methods and techniques. However, it was recognized that what remains is to concretize the framework through specific examples and usage experience. Thus, following publication of the report, it is recommended that case studies be performed to illustrate and more precisely define specific phases and elements of the assessment framework. For example, current national assessment approaches could be mapped into the assessment framework to serve as case studies and help to identify any aspects of the assessment framework that needs further definition or adjustment. Additionally, a challenge problem could be defined to engage stakeholders to apply the assessment framework with a common focus. This could help to better illustrate strategic options and approaches to the assessment phases. It also could serve to suggest other considerations and potential sources of evidence not fully covered in the report. Based on findings from case studies, challenge problems and country experience, it should be possible to develop generalized templates to support application of the assessment framework. These findings can be collected to serve as the basis for a User's Guide on dependability assessment of safety software. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗

Fast DR: Controlling Small Loads over the Internet

Current state-of-the-art demand response systems are expensive due to extreme reliability constraints in telemetry, control, and metering. The typical cost of enabling a site for regulation services is between $50k and $80k. These costs are orders of magnitude too high for small loads to participate in high-value grid services. Traditional demand response (DR) schedules events in advance and provides basic on/off control. We developed fast DR measurement and communication technologies, which are scalable cost-effective demand response systems with sufficient reliability for real-time control and monitoring of loads over the internet, and we demonstrated an example system for under $100. We installed FastDR systems for lighting, motor, and thermostat control along with power metering at a total of 10 sites, including 6 commercial buildings and 4 residential buildings. This demonstration addressed the following important methodological questions: 1) Can we reliably control loads simultaneously and with low latency across multiple sites within a specified response time; 2) How reliable is using the internet or 4G cellular network as the mode of control and metering; and 3) Can existing Smart Meters provide data for real-time telemetry services. Testing shows fast DR is capable of control to response in 4 seconds and loads complete transition in seconds to less than one minute depending on load type. We demonstrated 4s regulation services and synchronized load control, and we successfully met specifications for ancillary services across the US. Telemetry via the 4G cellular network demonstrated 94.5% success rate, and residential Internet demonstrated a 98% success rate.

Kiliccote, Sila↗

Privacy-Preserving Aggregation of Controllable Loads to Compensate Fluctuations in Solar Power

Cybersecurity and privacy are of the utmost importance for safe, reliable operation of the electric grid. It is well known that the increased connectivity/interoperability between all stakeholders (e.g., utilities, suppliers, and consumers) will enable personal information collection. Significant advanced metering infrastructure (AMI) deployment and demand response (DR) programs across the country, while enable enhanced automation, also generate energy data on individual consumers that can potentially be used for exploiting privacy. Inspired by existing works which consider DR, battery-based perturbation, and differential privacy noise adding, we novelly consider the aggregator (cluster) level privacy issue in the DR framework of solar photovoltaic (PV) generation following. Different from most of the existing works which mainly rely on the charging/discharging scheduling of rechargeable batteries, we utilize controllable building loads to serve as virtual storage devices to absorb a large portion of the PV genertaion while delicately keeping desired noisy terms to satisfy the differential privacy for the raw load profiles at the aggregator level. This not only ensures differential privacy, but also improves the DR efficiency in load following since part of the noisy signal in solar PV generation has been filtered out. In particular, a mixed integer quadratic optimization problem is formulated to optimally dispatch a population of on/off controllable loads to achieve this privacy-preserving DR service.

Dong, Jin↗

Power quality of service optimization for microgrids

Various examples are provided for power quality of service optimization for microgrids. In one example, among others, a microgrid includes a smart meter configured to control supply of electric power to loads based at least in part upon energy consumption scheduling of the loads, which is based at least in part upon an effective electric generation capacity associated with the microgrid. The energy consumption scheduling can be based at least in part upon estimated power output of a sustainable energy resource of the microgrid and a load demand characterization of the loads. In another example, a system comprises a plurality of microgrids and an advanced metering infrastructure (AMI) configured to monitor operations of the microgrids and to control supply of electric power from sustainable energy resources and energy storage systems to loads of the microgrids via smart meters based at least in part upon energy consumption scheduling of the loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Muons Inc Master CRADA with Annex A for Magnetron Development

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time.

43 PARTICLE ACCELERATORS↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Optimal Power Flow Pursuit

This paper considers distribution networks featuring inverter-interfaced distributed energy resources, and develops distributed feedback controllers that continuously drive the inverter output powers to solutions of AC optimal power flow (OPF) problems. Particularly, the controllers update the power setpoints based on voltage measurements as well as given (time-varying) OPF targets, and entail elementary operations implementable onto low-cost microcontrollers that accompany power-electronics interfaces of gateways and inverters. The design of the control framework is based on suitable linear approximations of the AC power-flow equations as well as Lagrangian regularization methods. Convergence and OPF-target tracking capabilities of the controllers are analytically established. Overall, the proposed method allows to bypass traditional hierarchical setups where feedback control and optimization operate at distinct time scales, and to enable real-time optimization of distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Strategies for Continuous Balancing in Future Power Systems with High Wind and Solar Shares

The use of wind power has grown strongly in recent years and is expected to continue to increase in the coming decades. Solar power is also expected to increase significantly. In a power system, a continuous balance is maintained between total production and demand. This balancing is currently mainly managed with conventional power plants, but with larger amounts of wind and solar power, other sources will also be needed. Interesting possibilities include continuous control of wind and solar power, battery storage, electric vehicles, hydrogen production, and other demand resources with flexibility potential. The aim of this article is to describe and compare the different challenges and future possibilities in six systems concerning how to keep a continuous balance in the future with significantly larger amounts of variable renewable power production. A realistic understanding of how these systems plan to handle continuous balancing is central to effectively develop a carbon-dioxide-free electricity system of the future. The systems included in the overview are the Nordic synchronous area, the island of Ireland, the Iberian Peninsula, Texas (ERCOT), the central European system, and Great Britain.

14 SOLAR ENERGY↗