Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Modelflow Estimates of Stroke Volume Do Not Correlate With Doppler Ultrasound Estimates During Upright Posture

Orthostatic intolerance affects 60‐80% of astronauts returning from long‐duration missions, representing a significant risk to completing mission‐critical tasks. While likely multifactorial, a reduction in stroke volume (SV) represents one factor contributing to orthostatic intolerance during stand and head up tilt (HUT) tests. Current measures of SV during stand or HUT tests use Doppler ultrasound and require a trained operator and specialized equipment, restricting its use in the field. BeatScope (Finapres Medical Systems BV, The Netherlands) uses a modelflow algorithm to estimate SV from continuous blood pressure waveforms in supine subjects; however, evidence supporting the use of Modelflow to estimate SV in subjects completing stand or HUT tests remain scarce. Furthermore, because the blood pressure device is held extended at heart level during HUT tests, but allowed to rest at the side during stand tests, changes in the finger arterial pressure waveform resulting from arm positioning could alter modelflow estimated SV. The purpose of this project was to compare Doppler ultrasound and BeatScope estimations of SV to determine if BeatScope can be used during stand or HUT tests. Finger photoplethysmography was used to acquire arterial pressure waveforms corrected for hydrostatic finger‐to‐heart height using the Finometer (FM) and Portapres (PP) arterial pressure devices in 10 subjects (5 men and 5 women) during a stand test while simultaneous estimates of SV were collected using Doppler ultrasound. Measures were made after 5 minutes of supine rest and while subjects stood for 5 minutes. Next, SV estimates were reacquired while each arm was independently raised to heart level, a position similar to tilt testing. Supine SV estimates were not significantly different between all three devices (FM: 68+/-20, PP: 71+/-21, US: 73+/-21 ml/beat). Upon standing, the change in SV estimated by FM (‐18+/-8 ml) was not different from PP (‐21+/-12), but both were significantly less than US (‐37+/-16 ml, p<.05). Raising finger BP devices to heart level caused no significant change in SV measured with any of the devices (FM: 1.5+/-19, PP: 1.7+/-26, US: 0.5+/-6), although variability was 3‐6x greater as assessed by both blood pressure devices compared to US. Retrospective analysis of blood pressure data to assess SV in 11 supine subjects revealed significantly different estimates between methods (FM: 95+/-17, US: 75+/-32, p<.05), but the change in SV resulting from HUT was similar between methods (FM: ‐37+/-9, US: ‐40+/-18 ml). However, the correlation coefficient determined from pairs of SV estimated by US and FM was weak (r2=0.03). These data suggest Modelflow cannot be used in lieu of Doppler ultrasound to estimate SV during stand or HUT tests. Further investigation should focus on identifying factors contributing to differences between these measurement techniques in order to make use of a simple method for assessing beat‐by‐beat changes in SV during postural changes, especially during field testing.

Ferguson, Connor R.↗

Hardness Assurance Techniques for New Generation COTS Devices

Hardness Assurance (HA) techniques and total dose radiation characterization data for new generation linear and COTS devices from various manufacturers are presented. A bipolar op amp showed significant degradation at HDR, not at low dose rate environment. New generation low-power op amps showed more degradation at low voltage applications. HA test techniques for COTS devices are presented in this paper.

New Millenium advanced technologies miniature spac↗

CALMOS: Innovative device for the measurement of nuclear heating in material testing reactors

An R and D program has been carried out since 2002 in order to improve gamma heating measurements in the 70 MWth OSIRIS Material Testing Reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. Throughout this program an innovative calorimetric probe associated to a specific handling system has been designed in order to make measurements both along the fissile height and on the upper part of the core, where nuclear heating rates still remain high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for the process validation, while a displacement system has been especially designed to move the probe axially. A final probe has been designed thanks to modeling results and to preliminary measurements obtained with mock-ups irradiated to a heating level of 2W/g, This paper gives an overview of the development, describes the calorimetric probe, and expected advantages such as the possibility to use complementary methods to get the nuclear heating measurement. Results obtained with mock-ups irradiated in ex-core area of the reactor are presented and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical scanning tests of complex CMOS microcircuits

The new test method was based on the use of a raster-scanned optical stimulus in combination with special electrical test procedures. The raster-scanned optical stimulus was provided by an optical spot scanner, an instrument that combines a scanning optical microscope with electronic instrumentation to process and display the electric photoresponse signal induced in a device that is being tested.

Levy, M. E.↗

Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

LaBel, Kenneth A.↗

Non-invasive, MRI-compatible fibreoptic device for functional near-IR reflectometry of human brain

A non-invasive device for measuring blood oxygen variations in human brain is designed, implemented, and tested for MRI compatibility. The device is based on principles of near-IR reflectometry; power LEDs serve as sources of probing radiation delivered to patient skin surface through optical fibres. Numerical Monte Carlo simulations of probing radiation propagation in a multilayer brain model are performed to evaluate signal levels at different source - detector separations at three operation wavelengths and an additional wavelength of 915 nm. It is shown that the device can be applied for brain activity studies using power LEDs operating at 830 and 915 nm, while employment of wavelength of 660 nm requires an increased probing power. Employment of the wavelength of 592 nm in the current configuration is unreasonable. (application of lasers and laser-optical methods in life sciences)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Water Blade Strain Measurements on a Vertical-Axis Tidal Turbine

Open-water testing of marine renewable energy devices represents a significant milestone and hurdle for research teams and companies that seek to reduce the levelized cost of energy to allow these devices to compete in the open electrical generation market. For open-water testing of tidal energy converters (TECs), accurate measurements of loading characteristics on the blades and other structural components correlated with power performance metrics can be invaluable to further refine design principles and models, allowing continued improvement and cost reductions of new turbine designs. This paper will describe the modifications and additions made to a TEC system to achieve time-correlated blade strain measurements during full turbine operation along with a discussion on the overall impacts the required modifications had on the unmodified turbine.

mechanical loads↗

Full-scale wind-tunnel tests of a small unpowered jet aircraft with a T-tail

The aerodynamic characteristics of a full scale executive type jet transport aircraft with a T-tail were investigated in a 40 x 80 ft (12.2 by 24.4 meter) wind tunnel (subsonic). Static, longitudinal, and lateral stability, and control characteristics were determined at angles of attack from -2 deg to +42 deg. The aircraft wing had 13 deg of sweep and an aspect ratio of 5.02. The aircraft was tested power off with various wing leading- and trailing-edge high lift devices. The basic configuration was tested with and without such components as engine nacelles, wing tip tanks, and empannage. Hinge-moment data were obtained and downwash angles in the horizontal-tail plane location were calculated. The data were obtained at Reynolds numbers of 4.1 million and 8.7 million based on mean aerodynamic chord. The model had static longitudinal stability through initial stall. Severe tail buffet occurred near the angle of attack for maximum lift. Above initial stall the aircraft had pronounced pitch-up, characteristic of T-tail configurations. A stable trim point was possible at angles of attack between 30 deg and 40 deg (depending on c.g. location and flap setting). Hinge-moment data showed no regions with adverse effects on stick force. Comparisons of wind-tunnel data and flight-test are presented.

Soderman, P. T.↗

Two-stage, low noise advanced technology fan. 4: Aerodynamic final report

A two-stage research fan was tested to provide technology for designing a turbofan engine for an advanced, long range commercial transport having a cruise Mach number of 0.85 -0.9 and a noise level 20 EPNdB below current requirements. The fan design tip speed was 365.8m/sec (1200ft/sec);the hub/tip ratio was 0.4; the design pressure ratio was 1.9; and the design specific flow was 209.2 kg/sec/sq m(42.85lbm/sec/sq ft). Two fan-versions were tested: a baseline configuration, and an acoustically treated configuration with a sonic inlet device. The baseline version was tested with uniform inlet flow and with tip-radial and hub-radial inlet flow distortions. The baseline fan with uniform inlet flow attained an efficiency of 86.4% at design speed, but the stall margin was low. Tip-radial distortion increased stall margin 4 percentage points at design speed and reduced peak efficiency one percentage point. Hub-radial distortion decreased stall margin 4 percentage points at all speeds and reduced peak efficiency at design speed 8 percentage points. At design speed, the sonic inlet in the cruise position reduced stall margin one percentage point and efficiency 1.5 to 4.5 percentage points. The sonic inlet in the approach position reduced stall margin 2 percentage points.

Harley, K. G.↗

Escort: A data acquisition and display system to support research testing

Primarily designed to acquire data at steady state test conditions, the system can also monitor slow transients such as those generated in moving to a new test condition. The system configuration makes use of a microcomputer at the test site which acts as a communications multiplexer between the measurement and display devices and a centrally located minicomputer. A variety of measurement and display devices are supported using a modular approach. This allows each system to be configured with the proper combination of devices to meet the specific test requirements, while still leaving the option to add special interfaces when needed. Centralization of the minicomputer improves utilization through sharing. The creation of a pool of minis to provide data acquisition and display services to a variable number of running tests also offers other important advantages.

Miller, R. L.↗

Superfluid Helium On-Orbit Transfer (SHOOT) operatons

The in-flight tests and the operational sequences of the Superfluid Helium On-Orbit Transfer (SHOOT) experiment are outlined. These tests include the transfer of superfluid helium at a variety of rates, the transfer into cold and warm receivers, the operation of an extravehicular activity coupling, and tests of a liquid acquisition device. A variety of different types of instrumentation will be required for these tests. These include pressure sensors and liquid flow meters that must operate in liquid helium, accurate thermometry, two types of quantity gauges, and liquid-vapor sensors.

Kittel, P.↗

Superfluid Helium On-Orbit Transfer (SHOOT) operations

The in-flight tests and the operational sequences of the Superfluid Helium On-Orbit Transfer (SHOOT) experiment are outlined. These tests include the transfer of superfluid helium at a variety of rates, the transfer into cold and warm receivers, the operation of an extravehicular activity coupling, and tests of a liquid acquisition device. A variety of different types of instrumentation will be required for these tests. These include pressure sensors and liquid flow meters that must operate in liquid helium, accurate thermometry, two types of quantity gauges, and liquid-vapor sensors.

Kittel, P.↗

Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

Kelley, Anthony R.↗