Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAILURE MODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Diode step stress testing program for JANTX1N759A

The effect of power/temperature step stress when applied to a variety of voltage regulating diodes manufactured by Texas Instruments and Siemens was investigated. Test requirements are described and results are tabulated. Failure modes are discussed.

Source record↗

Effort of the Jet Propulsion Laboratory

A discussion is presented which gives an overview of the research and technological areas on nickel cadmium batteries at the Jet Propulsion Laboratory. Some of the topics covered include: goals; failure modes and mechanisms; factors of degradation and some possible solutions; energy density; and accomplishments for FY 77 and FY 78.

Bogner, S.↗

Correlation study between vibrational environmental and failure rates of civil helicopter components

An investigation of two selected helicopter types, namely, the Models 206A/B and 212, is reported. An analysis of the available vibration and reliability data for these two helicopter types resulted in the selection of ten components located in five different areas of the helicopter and consisting primarily of instruments, electrical components, and other noncritical flight hardware. The potential for advanced technology in suppressing vibration in helicopters was assessed. The are still several unknowns concerning both the vibration environment and the reliability of helicopter noncritical flight components. Vibration data for the selected components were either insufficient or inappropriate. The maintenance data examined for the selected components were inappropriate due to variations in failure mode identification, inconsistent reporting, or inaccurate informaton.

Alaniz, O.↗

Design fabrication and test of graphite/polyimide composite joints and attachments for advanced aerospace vehicles

Graphite/polyimide (Gr/PI) bolted and bonded joints were investigated. Possible failure modes and the design loads for the four generic joint types are discussed. Preliminary sizing of a type 1 joint, bonded and bolted configuration is described, including assumptions regarding material properties and sizing methodology. A general purpose finite element computer code is described that was formulated to analyze single and double lap joints, with and without tapered adherends, and with user-controlled variable element size arrangements. An initial order of Celion 6000/PMR-15 prepreg was received and characterized.

Source record↗

Effects of moisture on torsion and flexure properties of graphite-epoxy composites

The effects of moisture and temperature on unidirectional and multi-ply laminates of T300/934 and AS/3501 graphite-epoxy systems were investigated. Properties studied were static flexure strength, and flexure and torsion fatigue strengths at room temperature and at 74 C. Specimens with increased moisture content showed a reduced static flexure strength; water as the test environment had only a negligible influence. In flexure fatigue and torsion fatigue, the water environment caused somewhat reduced fatigue strengths at room temperature and significantly greater degradation in 74 C water. The failure mode in all cases was interlaminar delamination.

Sumsion, H. T.↗

Configuration analysis of nickel hydrogen cell

The significance of various stack configurations and components on the cycle life for nickel hydrogen cells for synchronous orbit used was evaluated. Failure modes of electrolyte management and 02 management were solved by modifications in the reservoir, the wick, and/or the stack configuration.

Holleck, G.↗

Safety considerations in the design and operation of large wind turbines

The engineering and safety techniques used to assure the reliable and safe operation of large wind turbine generators utilizing the Mod 2 Wind Turbine System Program as an example is described. The techniques involve a careful definition of the wind turbine's natural and operating environments, use of proven structural design criteria and analysis techniques, an evaluation of potential failure modes and hazards, and use of a fail safe and redundant component engineering philosophy. The role of an effective quality assurance program, tailored to specific hardware criticality, and the checkout and validation program developed to assure system integrity are described.

Reilly, D. H.↗

User experience with on-road electric vehicles in the U.S.A. and Canada

Approximately 3000 on-road electric passenger cars and delivery vans are now in use in the U.S.A. and Canada. The owners and operators of almost one-third of these vehicles have been surveyed directly in an attempt to determine the suitability of commercially sold electric vehicles for real on-road jobs. This paper is primarily concerned with the analysis of the engineering aspects of the user experience with electric vehicles, i.e., mileage and application, failure modes and rates, energy economy, maintenance requirements, life cycle costs, and vehicle performance characteristics. It is concluded that existing electric vehicles can perform satisfactorily in applications that have limited performance requirements, particularly in terms of range.

Sandberg, J. J.↗

An engineering approach to the prediction of fatigue behavior of unnotched/notched fiber reinforced composite laminates

An engineering approach is proposed for predicting unnotched/notched laminate fatigue behavior from basic lamina fatigue data. The fatigue analysis procedure was used to determine the laminate property (strength/stiffness) degradation as a function of fatigue cycles in uniaxial tension and in plane shear. These properties were then introduced into the failure model for a notched laminate to obtain damage growth, residual strength, and failure mode. The approach is thus essentially a combination of the cumulative damage accumulation (akin to the Miner-Palmgren hypothesis and its derivatives) and the damage growth rate (similar to the fracture mechanics approach) philosophies. An analysis/experiment correlation appears to confirm the basic postulates of material wearout and the predictability of laminate fatigue properties from lamina fatigue data.

Kulkarni, S. V.↗

An analysis of delamination in angle-ply fiber reinforced composites

An analytical investigation of the mechanics and failure modes of delamination initiated from a service-induced surface flaw in angle-ply fiber reinforced composites is presented. The analysis employs a hybrid-stress finite element method including a crack-tip singular element with its field variables expressed by Muskhelishvili's complex stress functions. Solutions are obtained for delaminated composites with various laminate parameters. The results elucidate unique and important characteristics of delamination crack-tip response and interlaminar stress transfer mechanisms. Of particular interest are the mixed-mode stress intensity factors associated with the delamination crack. The influence of ply orientation on KI and KII and their effects on subsequent crack extension are discussed.

Wang, S. S.↗

Impact behavior of filament-wound graphite/epoxy fan blades

The fabrication and impact tests of graphite/epoxy filament wound fan blades are discussed. Blades which were spin tested at tip speeds up to 305 m/sec retained their structural integrity. Two blades were each impacted with a 454-g slice of a 908-g simulated bird at a tip speed of 263 deg and impact angles of 22 deg and 32 deg. The impact tests were recorded with high-speed movie film. The blade which was impacted at 22 deg sustained some root delamination but remained intact. The 32 deg impact separated the blade from the root. No local damage other than leading-edge debonding was observed for either blade. The results of a failure mode analysis are also discussed.

Bowles, K. J.↗

Filtration effects on ball bearing life and condition in a contaminated lubricant

Ball bearings were fatigue tested with a noncontaminated MIL-L-23699 lubricant and with a contaminated MIL-L-23699 lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3- and 30-micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49-micron bearings were statistically lower. The 105-micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗

A life prediction methodology for encapsulated solar cells

This paper presents an approach to the development of a life prediction methodology for encapsulated solar cells which are intended to operate for twenty years or more in a terrestrial environment. Such a methodology, or solar cell life prediction model, requires the development of quantitative intermediate relationships between local environmental stress parameters and the basic chemical mechanisms of encapsulant aging leading to solar cell failures. The use of accelerated/abbreviated testing to develop these intermediate relationships and in revealing failure modes is discussed. Current field and demonstration tests of solar cell arrays and the present laboratory tests to qualify solar module designs provide very little data applicable to predicting the long-term performance of encapsulated solar cells. An approach to enhancing the value of such field tests to provide data for life prediction is described.

Coulbert, C. D.↗

Environmental requirements for flat plate photovoltaic modules for terrestrial applications

The environmental test requirements that have been developed for flat plate modules purchased through Department of Energy funding are described. Concurrent with the selection of the initial qualification tests from space program experience - temperature cycling and humidity - surveys of existing photovoltaic systems in the field revealed that arrays were experiencing the following failure modes: interconnect breakage, delamination, and electrical termination corrosion. These coupled with application-dependent considerations led to the development of additional qualification tests, such as cyclic pressure loading, warped mounting surface, and hail. Rationale for the selection of tests, their levels and durations is described. Comparisons between field-observed degradation and test-induced degradation show a positive correlation with some of the observed field effects. Also, the tests are proving useful for detecting design, process, and workmanship deficiencies. The status of study efforts for the development of environmental requirements for field-related problems is reviewed.

Hoffman, A. R.↗

JANTX1N2970B zener diode

Report evaluates effects of power and temperature overstress on General Semi-conductor and Siemens devices. Excessive failure rates limited testing. Failure modes are described.

Source record↗

JANTX2N2060 dual transistor

Report describes effects of power and temperature overstress on Motorola and Raytheon devices. Motorola devices were weak in power overstress. Raytheon devices succumbed to 160 hour temperature stress. Failure modes are detailed.

Source record↗

JANTX2N2219A dual transistor

Report describes effects of power and temperature overstress on Texas Instruments and National Semiconductor devices. Texas Instruments devices had only two failures in 2500 hours of testing. National Semiconductor devices reached 50% failure limit. No consistent failure mode was detected.

Source record↗

JANTX2N2432A transistor

Report evaluates effects of power and temperature overstress on Crystalonics and Texas Instruments devices. Crystalonics devices survived better, as Texas Instruments lot exceeded 50 percent failure at 225 deg C. Failure modes are evaluated.

Source record↗