Search NASA⌕ Search

SEARCH · Search NASA

Results for “Autonomous Reactivity Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tailoring the response of Autonomous Reactivity Control (ARC) systems

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety of Generation IV reactors while having a minimal impact on reactor performance and economic viability. In this study we present the transient response of fast reactor cores to postulated accident scenarios with and without ARC systems installed. Using a combination of analytical methods and numerical simulation, the principles of ARC system design that assure stability and avoids oscillatory behavior have been identified. A comprehensive transient analysis study for ARC-equipped cores, including a series of Unprotected Loss of Flow (ULOF) and Unprotected Loss of Heat Sink (ULOHS) simulations, were performed for Argonne National Laboratory (ANL) Advanced Burner Reactor (ABR) designs. With carefully designed ARC-systems installed in the fuel assemblies, the cores exhibit a smooth non-oscillatory transition to stabilization at acceptable temperatures following all postulated transients. To avoid oscillations in power and temperature, the reactivity introduced per degree of temperature change in the ARC system needs to be kept below a certain threshold the value of which is system dependent, the temperature span of actuation needs to be as large as possible.

ARC↗

Autonomous Reactivity Control (ARC) — Principles, geometry and design process

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety performance of Generation-IV reactors while having a minimal impact on reactor performance and economic viability. Here we present in detail the principles of how the ARC system operates, what materials should be used, what components make up the system and how they are interconnected. The relevant equations regarding how to design the system for a certain response are developed and defined, and the most important aspects determining the speed of actuation of the systems are analyzed. Thus, this study serves as the general reference material for all of the fundamental principles behind the ARC idea. Finally, we present a step-by-step guide to how a fast reactor fuel subassembly with an ARC system installed would be manufactured, using a full 3D-CAD model. For an ARC installation in a 1000 MWth sodium-cooled oxide-fueled fast reactor core, the system constitutes a relatively minor adjustment to a typical fuel assembly, increasing its total axial extent by ~5–10% and the total primary coolant pressure drop by ~1%. In conclusion, the main finding of this study is that it is possible to design, manufacture (using existing methods) and implement ARC systems in the fuel assemblies of fast reactor cores to provide inherent safety in all anticipated unprotected transients with only a modest increase in the length of the assembly and the pressure drop across the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutronic impact of Autonomous Reactivity Control system inclusion in a breed-and-burn core

This work examines the impacts induced in a large breed-and-burn core through the inclusion of Autonomous Reactivity Control (ARC) systems from the neutronics perspective. A combination of numerical and analytical techniques are used to conservatively quantify the reactivity penalty, amount of additional tritium production, and depletion of the system absorber fluid. The reactivity penalty is found to be negligibly small, with the largest impact resulting from the removal of fuel material to make room for the ARC system tubes. Similarly, the depletion of the absorber fluid is found to be negligible compared to the amount of fluid present. It is found that the production of tritium within the active core is also small in comparison to that which is nominally produced, while tritium production within the lower ARC system reservoir may be of concern if not adequately considered during the assembly design phase. This issue is explored and a mitigation technique is proposed. Ultimately this study concludes that there are no issues from the steady-state neutronics perspective preventing incorporation of ARC systems into typical breed-and-burn cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Performance Fast Reactors with Engineered Passive Safety Systems

This report summarizes the work and results of NEUP Project #15-8251, "Enhanced Performance Fast Reactors with Engineered Passive Safety System," performed from 2015-2018 at UC Berkeley and Argonne National Laboratory. This project concerns the incorporation of a novel engineered passive safety system, called the Autonomous Reactivity Control (ARC) system, into Sodium-cooled Fast Reactors (SFRs) to improve their transient and economic performance. The first part of this project consisted of fleshing out the basic principles and the manufacturing process for an SFR fuel assembly with the ARC system installed, with the details provided in high-quality, step-by-step CAD drawings. Once the detailed design is laid out, high-fidelity simulations were performed to optimize the dimensions of important ARC system components and to quantify the standalone time-response of ARC systems in a typical SFR environment. These high-fidelity simulations were used to create reduced-order models of ARC system response which could be incorporated into the SAS4A/SASSYS-1 whole-core transient models. In order to accurately account for the time-response of ARC systems in whole-core transient simulations, modifications were made to the SAS4A/SASSYS-1 transient code. These new capabilities were tested and incorporated into the production version of the code, and have been used extensively in this analysis. Before performing whole-core transient calculations, the two reference cores selected for this study to cover a wide design space were simulated and characterized. The two reference cores, (1) a medium-sized oxide-fueled Advanced Burner Reactor and (2) a large metal-fueled Breed-and-Burn core, challenge conventional means of achieving passive safety. Because the two cores vary substantially, simulating the ARC system in both allows for conclusions to be drawn about the applicability of ARC systems in different SFRs. Once both cores were fully characterized, transient calculations were performed to understand the complicated interplay between the ARC system and other inherent reactivity feedback mechanisms. By performing parametric studies of the transient behavior, ARC system designs that best improve transient performance in each core were identified. Once transient improvements were established, the transient calculations were extended to improve reactor economics through design modifications. Upon establishing the potential benefits of ARC system inclusion, the study examines the negative neutronic implications of incorporating ARC systems into the reference cores. The study concludes by discussing a number of knowledge gaps that exist which may have important implications for ARC system implementation. Ultimately, the results of this project indicate that ARC systems may provide an effective means to improve transient performance in certain types of systems. The transient simulations in the oxide Advanced Burner Reactor showed that significant margin to coolant boiling and fuel melting could be gained through the use of a properly designed ARC system, thus improving inherent safety. While oscillatory behavior was induced in the transient response for certain combinations of ARC system parameters, the oscillation-free design space that can be effectively used to improve performance was found to be large, and the additional margin was demonstrated to allow economical improvements to the core design. Conversely, difficulties were encountered in the Breed-and-Burn core due to fundamental aspects of the core design. The combination of a particularly strong positive coolant void feedback and the use of metallic fuel allowed for diverging oscillations to manifest in response to certain transient initiators, and in the end it was found that the current ARC system design could not simultaneously enable passive safety in all transients examined. In order for complete passive safety to be achieved, a mechanism for slowing the reverse actuation of ARC systems is necessary. Regardless, the standard ARC system was able to improve the performance of two out of the three examined transients by increasing the margin to boiling in Loss of Heat Sink transients and avoiding boiling in Transient Overpower accidents. Additionally, no significant barriers to implementation were found, although the issue of tritium production should be closely monitored in any core incorporating ARC systems. Still, a number of technology gaps exist, and these are discussed at the conclusion of the report to recommend directions for future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model-based Executive Control through Reactive Planning for Autonomous Rovers

This paper reports on the design and implementation of a real-time executive for a mobile rover that uses a model-based, declarative approach. The control system is based on the Intelligent Distributed Execution Architecture (IDEA), an approach to planning and execution that provides a unified representational and computational framework for an autonomous agent. The basic hypothesis of IDEA is that a large control system can be structured as a collection of interacting agents, each with the same fundamental structure. We show that planning and real-time response are compatible if the executive minimizes the size of the planning problem. We detail the implementation of this approach on an exploration rover (Gromit an RWI ATRV Junior at NASA Ames) presenting different IDEA controllers of the same domain and comparing them with more classical approaches. We demonstrate that the approach is scalable to complex coordination of functional modules needed for autonomous navigation and exploration.

Finzi, Alberto↗

Quantitative Trade-Off in Distributed Secondary Control for Autonomous AC Microgrids

In this paper, we propose to quantify the trade-off between voltage regulation and reactive power sharing in autonomous AC microgrids with distributed secondary control. It is known that voltage regulation and reactive power sharing in droop-controlled autonomous AC microgrids are two conflicting control objectives that present a natural trade-off between voltage regulation towards the voltage magnitude reference and reactive power sharing accuracy. This trade-off is commonly shown qualitatively without sufficient quantification. In this work, to quantify the trade-off between the two objectives, we focus on distributed secondary control and utilize regression and polynomial surface fitting to identify the requisite parameter area to satisfy the predefined error bands for voltage magnitude regulation and reactive power sharing. Extensive case studies are presented to validate the proposed method.

autonomous AC microgrids↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗

Integrating deliberative planning in a robot architecture

The role of planning and reactive control in an architecture for autonomous agents is discussed. The postulated architecture seperates the general robot intelligence problem into three interacting pieces: (1) robot reactive skills, i.e., grasping, object tracking, etc.; (2) a sequencing capability to differentially ativate the reactive skills; and (3) a delibrative planning capability to reason in depth about goals, preconditions, resources, and timing constraints. Within the sequencing module, caching techniques are used for handling routine activities. The planning system then builds on these cached solutions to routine tasks to build larger grain sized primitives. This eliminates large numbers of essentially linear planning problems. The architecture will be used in the future to incorporate in robots cognitive capabilites normally associated with intelligent behavior.

Elsaesser, Chris↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Impacts of Voltage-Based Grid-Support Functions on Energy Production of PV Customers: Preprint

This paper presents the impact of grid-support utility-interactive inverter functions, such as volt/volt-ampere reactive and volt/watt controls, on quasi-steady-state feeder voltages and on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, Hawai'i. These autonomous inverter controls provide an effective means to modulate active and reactive power based on local voltage measurements and therefore serve as good candidates for non-wire alternatives to increase PV hosting capacity. However, because the activation of these functions can result in PV energy curtailment, this study addresses the concerns about the impact of these advanced inverter controls on curtailment through detailed quasi-static time series (QSTS) simulations. This study proposes four metrics-maximum and average grid-support function curtailments, average increased generation, and average net generation change-to assess the impact of a given control on PV systems located on customer sites. For representative scenarios modeled in detail, it was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 ranges. A reliable relationship between curtailment and peak customer voltage is demonstrated, allowing peak voltage to be used as an indicator of curtailment without the need to measure curtailment directly.

14 SOLAR ENERGY↗

Automated Control for Nuclear Thermal Propulsion Start-Up using MOOSE-based Applications

This report presents a Griffin/Bison/RELAP-7 numerical model of a prototypical NTP system that features fuel assemblies arranged in rings, and which was designed to simulate rapid startup transients. The physics modeled include full-core neutronics, assembly-wise heat conduction, and conjugate heat transfer, with the balance of plant mainly imposed through boundary conditions. In addition, various forms of automated reactivity control were deployed by using the MOOSE to autonomously drive the model and simulate the reactor transitioning from assumed initial conditions to nominal power in a fraction of a minute. To generate the cross-sections of the neutronics model, and in an effort to simultaneously account for the tremendous axial temperature gradients in the reactor and to limit the number of state points required for cross-section generation, the average component temperatures and hydrogen densities in the cooling channels were correlated to the average fuel and moderator temperatures, and fixed axial profiles were derived for nominal conditions and then used during the transient. With this approximation, a tractable cross-section library tabulated with fuel/moderator temperatures and CD angles was generated using Serpent. The full-core SPH correction procedure and the CD decusping technology in Griffin, respectively, ensure preservation of the multiplication factor and reaction rates at state points, along with a reasonably accurate reactivity worth between tabulated CD angles, despite using a coarse mesh. Feedback from other physics was calculated by modeling one representative fuel assembly per ring, along with the corresponding fuel and moderator cooling channels. To limit power overshoots during startup, another layer of multiphysics coupling was added to the model in order to automatically control the drums. Two different technologies presented herein showed outstanding performance in this regard: (1) a novel hybrid PID controller based on both power and reactivity signals, and (2) a PGC that relies on kinetics parameters and reactivity coefficients to predict future behavior and adjust the desired signal accordingly. A challenging benchmark was devised, featuring a power demand curve that exponentially increases by a factor of 500 within 30 seconds, then levels out after that. Both control approaches create a simulated power curve that closely follows the power demand curve and limits power overshoots to 1% or less. While the former approach requires more tuning of the internal parameters, the latter requires additional knowledge of the reactivity feedback coefficients and rates of change of the corresponding variables, including fuel and moderator temperature, which could be difficult to dynamically measure for a real NTP system. Fortunately, some inaccuracy in these quantities will not drastically degrade the PGC performance. Subsequently, a more realistic startup sequence was considered, in which the mass flow rate and outlet pressures are ramped up to model bootstrap and thrust build-up phases prior to reaching steady-state conditions, demonstrating the ability of the hybrid PID and PGCs to handle such transients, with both types of controllers exhibiting very similar behavior. Nevertheless, a significant chamber temperature overshoot was observed, caused by the demanded power signal and assumed mass flow rate. This issue could be mitigated by deploying a reactor controller that follows the chamber temperature signal and actuates both the control valves and drums (rather than using a power signal based solely on the drums to control reactivity). Enhancement of the hydrogen fluid properties available in MOOSE, as well as a better understanding of prototypical initial conditions, are also needed to further enhance this startup model. Finally, a study was performed to model decay heat post-shutdown, and to prepare for extending this model to predict shutdown behavior and post-shutdown pulsed cooling requirements.

33 ADVANCED PROPULSION SYSTEMS↗

Interconnection and Interoperability Requirements of Hydrogen Assets to Enable Grid Integration

Traditionally, the inverters used for distributed energy resources (DERs) including solar, energy storage and hydrogen fuel cells are grid following assets. Grid following assets track real power and reactive power setpoints decided by either a local autonomous controller or a remote controller like a microgrid controller. In the past five years, multiple challenges have increased the need for grid forming inverters that can interface to a wide variety of energy resources. These grid forming inverters are becoming critical assets for power systems to enable the replacement of existing rotational machines and provide grid services such as grid resiliency services and black-start. Hydrogen assets (fuel cells) have the potential to successfully replace rotating machines and act as voltage and frequency master by leveraging the long-duration and seasonal energy storage capabilities of hydrogen technologies. This poster presents the progress made in budget period 1 of the proposed work. We will leverage an existing ARIES platform experimental setup to run power-hardware-in-the-loop and controller-hardware-in-the-loop experiments with grid forming fuel cell inverters to develop and document the standardization requirements.

electrolyzer↗

The NASA/Army Autonomous Rotorcraft Project

An overview of the NASA Ames Research Center Autonomous Rotorcraft Project (ARP) is presented. The project brings together several technologies to address NASA and US Army autonomous vehicle needs, including a reactive planner for mission planning and execution, control system design incorporating a detailed understanding of the platform dynamics, and health monitoring and diagnostics. A candidate reconnaissance and surveillance mission is described. The autonomous agent architecture and its application to the candidate mission are presented. Details of the vehicle hardware and software development are provided.

Whalley, M.↗

Experiments with a small behaviour controlled planetary rover

A series of experiments that were performed on the Rocky 3 robot is described. Rocky 3 is a small autonomous rover capable of navigating through rough outdoor terrain to a predesignated area, searching that area for soft soil, acquiring a soil sample, and depositing the sample in a container at its home base. The robot is programmed according to a reactive behavior control paradigm using the ALFA programming language. This style of programming produces robust autonomous performance while requiring significantly less computational resources than more traditional mobile robot control systems. The code for Rocky 3 runs on an eight bit processor and uses about ten k of memory.

Miller, David P.↗