Design of Graded Cathode Catalyst Layers with Various Ionomers for Fuel Cell Application

Proton exchange membrane fuel cells (PEMFCs) powered by green hydrogen (H2) have become a promising alternative to conventional hydrocarbon-fueled power generators. Despite technological advancements, further improvements in efficiency, durability, and low-cost production are required for the widespread adoption of PEMFCs. Though numerous approaches to improve PEMFC electrodes have been reported, most strategies utilize a single material set (e.g., one combination of catalyst and ionomer) to improve performance. Alternatively, anisotropic (graded) electrode structures with locally tunable properties may yield superior electrode performance due to improved ionic and gas phase transport. In this work, graded cathode catalyst layers (CCLs) incorporating different ionomers (Nafion D2020, Aquivion D79-25BS, and HOPI) were designed and prepared. Performance screening shows that some of these graded electrode structures have comparable performance to optimized single-ionomer electrode structures (D2020) suggesting some synergistic benefit. Additionally, we show that electrodes with lower equivalent weight (EW) D79 ionomer near the membrane and D2020 ionomer near the gas diffusion media outperformed electrodes with the inverted configuration. Finally, EIS analysis shows some graded ionomer structures (e.g. D79/D2020) have better than expected H+ conductivity, generally leading to better electrode performance. However, further optimization of ionomer content and catalyst ink formulations is needed to improve overall PEMFC performance.

DIRECT ENERGY CONVERSION↗

Design of PGM-free cathodic catalyst layers for advanced PEM fuel cells

Here, the design of cathodic catalysts layer (CCL) consisted of Platinum Group Metal-free (PGM-free) electrocatalysts was done by catalyst coated membrane approach. Three different Fe-Mn-N-C compounds were synthesized with Fe:Mn ratio of 1:1, 2:1 and 2:1 with modified heat treatment profile. The catalysts were characterized by X-ray photoelectron spectroscopy, X-ray powder diffraction, pore and particle size distribution, zeta potential and transmission electron microscopy. Electrocatalysts were integrated into membrane electrode assembly and evaluated by electrochemical methods. Electrochemical impedance spectroscopy in combination with modeling were used for estimation of proton conductivity of CCL and its oxygen diffusivity. It was found that all CCLs possess extremely high proton conductivity, which was demonstrated for the first time for these types of PGM-free catalysts. The observed ORR mechanism was predominantly 4e- due to peroxide/radicals scavenging effect of Mn.

impedance↗

Physically Based Modeling of PEMFC Cathode Catalyst Layers: Effective Microstructure and Ionomer Structure–Property Relationship Impacts

Abstract This work presents a pseudo-two-dimensional proton exchange membrane fuel cell (PEMFC) model incorporating Nafion ionomer structure–property relationships in the cathode catalyst layer (CL) to capture and explain losses at low Pt loading. Structural data from neutron reflectometry and thin film Nafion conductivity measurements predict variations in the oxygen diffusion coefficient and ionic conductivity with changing CL ionomer thickness and Pt loading. By including these structure–property relationships, predicted polarization curves agree closely with previously published experimental data from cells with Pt loadings between 0.025 and 0.2 mg/cm2. Results demonstrate that structure–property relationships based on physically measurable ionomer and CL properties provide a feasible interpretation of PEMFC CL phenomena for a range of Pt loadings and help explain previously unaccounted-for losses at low Pt. Results also show that simulations must account for surface species coverage variations in order to properly capture the kinetic losses. Finally, results suggest that an increase in ionomer thickness surrounding the C/Pt surfaces may lead to improved cell performance due to improved ionic conductivity.

Electrochemistry↗

Slot-die-coating operability windows for polymer electrolyte membrane fuel cell cathode catalyst layers

Roll-to-roll (R2R) slot-die coating of polymer electrolyte membrane fuel cell (PEMFC) catalyst layers represents a scalable deposition method for producing 10–20 m 2 ·min -1 of catalyst-coated gas diffusion layers (GDLs). This high-throughput production technique will help lower the cost of PEMFC catalyst layers. The uniformity of the wet layer applied by slot die deposition is affected by process parameters such as substrate speed, vacuum pressure applied at the upstream meniscus, gap between the slot die lips and substrate, ink rheology, and other ink and substrate properties. The set of conditions for producing a defect-free coating with a dilute ink typically requires little to no upstream vacuum pressure, so suitable operating conditions can be found easily through trial and error and operator intuition. However, the higher viscosity of more concentrated inks dramatically shifts the range of settings that result in a homogeneous coating to higher vacuum levels, which are harder to find through hit or miss. A predictive model showing the range of operable conditions decreases material wastage inherent in experimentally searching for suitable parameters. In this study, the defect-free coating parameter window is explored experimentally and theoretically for two concentrations of PEFC cathode inks. Both a full capillary hydrodynamic model and a computationally cheaper viscocapillary model successfully predict the experimentally determined coating window within the experimental and model uncertainty limits for inks with 5.3 wt% and 12.0 wt% solids ink while maintaining the 0.1 mg Pt ·cm -2 Pt areal loading target. Here, this paper demonstrates a viable pathway for meeting the $30/kW net ultimate cost target of the United States Department of Energy (U.S. DOE) Hydrogen Fuel Cells Technologies Office (HFTO). The concentrated ink lowers the thermal energy and capital expenditure (CapEx) budget of the coating process by decreasing the amount of time, energy, and floorspace required for drying the coating.

25 ENERGY STORAGE↗

Impact of polymer additives on crack mitigation of rod-coated fuel cell cathode catalyst layers

Cracks in catalyst layers (CLs) are a potential source of long-term failure in a fuel cell membrane electrode assembly (MEA). While modifications to the CL ink formulation can affect the degree of cracking, these changes may lead to lower initial performance than their cracked analogues due to the established link between formulation and performance. In this work, we explored the use of polymeric additives to mitigate CL cracks. Small quantities of poly (acrylic acid), poly (ethylene oxide), poly (methyl methacrylate), or poly (vinyl alcohol) - 5 wt% relative to ionomer mass - were added to the ink prior to its final mixing. Poly (vinyl alcohol) resulted in crack-free CLs, whereas the other polymers resulted in CLs with similar crack percentages as the control CL. Through a combination of transmission electron microscopy, X-ray computed tomography, and infrared spectroscopy, we ascribed the crack-mitigating mechanism of poly (vinyl alcohol) to its ability to hydrogen-bond with Nafion, the ion conducting polymer binder in the catalyst ink. Initial performance of this non-cracked electrode exhibited nearly identical electrochemical behavior to its cracked counterpart, demonstrating that PVA additives successfully reduce cracks while maintaining cell initial performance.

30 DIRECT ENERGY CONVERSION↗

A Numerical Study on the Impact of Cathode Catalyst Layer Loading on the Open Circuit Voltage

The open-circuit voltage (OCV) is the measured potential when no current is drawn from a cell. Additionally, theoretically this potential is given by the equilibrium potential, which is determined from thermodynamics based on the operating conditions. In practice, the actual potential at zero current is measured to be approximately 300 mV lower than the theoretical value.

42 ENGINEERING↗

Membrane‐electrode assembly design parameters for optimal CO 2 reduction

Commercial-scale generation of carbon-containing chemicals and fuels by means of electrochemical CO 2 reduction (CO 2 R) requires electrolyzers operating at high current densities and product selectivities. Membrane-electrode assemblies (MEAs) have been shown to be suitable for this purpose. In such devices, the cathode catalyst layer controls both the rate of CO 2 R and the distribution of products. In this study, we investigate how the ionomer-to-catalyst ratio (I:Cat), catalyst loading, and catalyst-layer thickness influence the performance of a cathode catalyst layer containing Ag nanoparticles supported on carbon. In this paper, we explore how these parameters affect the cell performance and establish the role of the exchange solution (water vs. CsHCO 3 ) behind the anode catalyst layer in cell performance. We show that a high total current density is best achieved using an I:Cat ratio of 3 at a Ag loading of 0.01–0.1 mg Ag /cm 2 and with a 1.0 M solution of CsHCO 3 circulated behind the anode catalyst layer. For these conditions, the optimal CO partial current density depends on the voltage applied to the MEA. The work also reveals that the performance of the cathode catalyst layer is limited by a combination of the electrochemically active surface area and the degree to which mass transfer of CO 2 to the surface of the Ag nanoparticles and the transport of OH – anions away from it limit the overall catalyst activity. Hydration of the ionomer in the cathode catalyst layer is found not to be an issue when using an exchange solution. The insights gained allowed for a Ag CO 2 R MEA that operates between 200 mA/cm 2 and 1 A/cm 2 with CO faradaic efficiencies of 78–91%, and the findings and understanding gained herein should be applicable to a broad range of CO 2 R MEA-based devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus and method associated with reformer-less fuel cell

An electrolyte membrane for a reformer-less fuel cell is provided. The electrolyte membrane is assembled with fuel and air manifolds to form the fuel cell. The fuel manifold receives an oxidizable fuel from a fuel supply in a gaseous, liquid, or slurry form. The air manifold receives air from an air supply. The electrolyte membrane conducts oxygen in an ionic superoxide form when the fuel cell is exposed to operating temperatures above the boiling point of water to electrochemically combine the oxygen with the fuel to produce electricity. The electrolyte membrane includes a porous electrically non-conductive substrate, an anode catalyst layer deposited along a fuel manifold side of the substrate, a cathode catalyst layer deposited along an air manifold side of the substrate, and an ionic liquid filling the substrate between the anode and cathode catalyst layers. Methods for manufacturing and operating the electrolyte membrane are also provided.

Sahu, Saroj Kumar↗

Effect of Commercial Gas Diffusion Layers on Catalyst Durability of Polymer Electrolyte Fuel Cells in Varied Cathode Gas Environment

Gas diffusion layers (GDLs) play a crucial role in heat transfer and water management of cathode catalyst layers in polymer electrolyte fuel cells (PEFCs). Thermal and water gradients can accelerate electrocatalyst degradation and therefore the selection of GDLs can have a major influence on PEFC durability. Currently, the role of GDLs in electrocatalyst degradation is poorly studied. Here, we perform electrocatalyst accelerated stress test studies on membrane electrode assemblies (MEAs) prepared using three most commonly used GDLs. The effect of GDLs on electrocatalyst degradation is evaluated in both nitrogen (non-reactive) and air (reactive) gas environments at 100% relative humidity. In situ electrochemical characterization and extensive physical characterization is performed to understand the subtle differences in electrocatalyst degradation and correlated to the use of different GDLs. Overall, no difference is observed in the electrocatalyst degradation due to GDLs based on polarization curves at the end of life. But interestingly, MEA with a cracked microporous layer (MPL) in the GDL exhibited a higher electrocatalyst loading loss, which resulted in a lower and more heterogeneous increase in the average electrocatalyst nanoparticle size.

25 ENERGY STORAGE↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Elucidating the Role of Ionomer in the Performance of Platinum Group Metal-free Catalyst Layer via in situ Electrochemical Diagnostics

The ionomer content in platinum group metal (PGM)-free polymer electrolyte fuel cell (PEFC) cathode catalyst layer (CCL) plays an important role in the electrode gas transport properties, proton conductivity, and hence, membrane electrode assembly (MEA) performance. In this work, the ionomer content in the CCL is varied, influencing electrode microstructure by altering porosity, tortuosity, as well as ionomer distribution and coverage of the catalyst particles. A novel technique consisting of a H 2 pump, combined with a Pt black sensor layer, is used to measure the bulk mass transport resistance of a series of PGM-free CCL prepared with different ionomer contents. The values for bulk electrode mass transport resistance are contrasted with electrode proton transport resistance in the cathode catalyst layer, establishing a clearly defined trade-off between two key performance limiting phenomena and identifying a need for novel PGM-free electrode fabrication strategies.

25 ENERGY STORAGE↗

Mechanistic and Mitigation-Strategy Insights into NaCl and CaCl 2 Contamination of Proton-Exchange-Membrane Water Electrolysis Using Continuum Modeling

Cationic contaminants are detrimental to proton-exchange-membrane water electrolyzers (PEMWEs). To obtain insight, a 1-D, nonisothermal, multiphase continuum cell model including cationic contamination is developed. Simulations of steady-state cell performance predict decreased performance due to an increase in kinetic overpotential associated with the hydrogen-evolution reaction, which was attributed to decreased protonic-activity within the cathode catalyst layer from proton supplantation with contaminant cations. The accumulation and extent of cation exchange in the cathode catalyst layer depends on the operating current density due to migration. Simulations of cell recovery of potential suggest that a contaminated cell can recover approximately 78% (450 mV) with 24 h of constant current density operation at 2 A cm –2 , with higher current densities accelerating reduced recovery times. Parametric studies show that anode-side acidification at lower current densities inhibit cation contaminant adsorption, and cathode-side acidification at larger current densities facilitate the expulsion of adsorbed cations; for a cathode-side pH of 6 and 5, the cell can recover an additional 10% and 100% performance, respectively. Overall, the model serves as a framework for modeling other aspects of PEMWE systems to address durability and performance aspects, which can assist in improving the viability of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Performance PEFC Electrode Structures

Raytheon Technologies Research Center (RTRC) in collaboration with Ion Power Inc. and the University of Arkansas at Little Rock and the FC-PAD consortium executed a project that: (1) developed comprehensive models of oxygen and proton transport in cathode catalyst layers that provided new insights about losses associated with reducing platinum loading to 0.1 mg/cm 2 , (2) designed, fabricated, characterized, and tested cells featuring carbon-supported catalyst layers with low platinum loadings that met efficiency and power density targets set forth by the Hydrogen and Fuel Cells Technology Office, and (3) designed, fabricated, characterized, and tested novel catalyst structures. The modeling efforts produced eight scientific publications that shared new descriptions of oxygen and proton transport in catalyst layers with the broader technical community. The key physical insights from the models are expressed in straightforward algebraic expressions, facilitating easy adoption by other researchers. The models developed during the project explain why resistance to oxygen transport is inversely proportional to interfacial area of platinum – an observation that eluded quantitative explanation for a decade. The models quantitatively predict polarization when measured morphological parameters and transport properties are input. Membrane-electrode assemblies made during the project met stated goals for current at high voltage and power density at rated voltage for transportation fuel cells at the end of budget period 2. High performance was achieved by developing a diffusion layer with low resistance to oxygen transport and a PtCo/C cathode catalyst layer capable of supporting rapid proton and oxygen transport. The project was subsequently directed to curtail experimental work and focus on modeling during budget period 3. Ion Power Inc. developed new expertise in fabricating catalyst layers containing platinum-cobalt catalysts, and processing very thin membranes. The University of Arkansas at Little Rock developed novel nanocolumnar self-supported thin film electrocatalysts that can be grown on carbon supports using a simple high pressure sputter deposition method. The nanocolumnar microstructure provides adequate surface-to-volume ratio for efficient platinum utilization, and the conformal platinum shell with larger crystal grain sizes covering the carbon support surface may eliminate durability issues associated with catalyst dissolution, agglomeration, and carbon corrosion.

08 HYDROGEN↗

Revealing in-plane movement of platinum in polymer electrolyte fuel cells after heavy-duty vehicle lifetime

Fuel cell heavy-duty vehicles (HDVs) require increased durability of oxygen-reduction-reaction electrocatalysts, making knowledge of realistic degradation mechanisms critical. Here identical-location micro-X-ray fluorescence spectroscopy was performed on membrane electrode assemblies. The results exposed heavy in-plane movement of electrocatalyst after HDV lifetime, suggesting that electrochemical Ostwald ripening may not be a local effect. Development of local loading hotspots and preferential movement of electrocatalyst away from cathode catalyst layer cracks was observed. The heterogeneous degradation exhibited by a modified cathode gas diffusion layer membrane electrode assembly after HDV lifetime was successfully quantified by the identical-location approach. Further synchrotron micro-X-ray diffraction and micro-X-ray fluorescence experiments were performed to obtain the currently unknown correlation between electrocatalyst nanoparticle size increase and loading change. A direct correlation was discovered which developed only after HDV lifetime. Finally, the work provides a route to engineer immediate system-level mitigation strategies and to develop structured cathode catalyst layers with durable electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled continuum and network model framework to study catalyst layers of polymer electrolyte fuel cells

The nanostructured thin film (NSTF) catalyst layers which have demonstrated high power densities, mass activities, and exceptional metal and support stability can have limited operational robustness due to their thin thickness and the hydrophilicity of the metal-coated nano whiskers. The dispersed nanostructured thin film (dNSTF) catalyst layers have been developed by dispersing the NSTF Pt whiskers with ionomer and carbon support to increase the thickness and hydrophobicity. Continuum and network models (NM) are coupled through boundary conditions to study the polymer electrolyte fuel cell with a dNSTF cathode catalyst layer. The coupled model combines the computational efficiency of the continuum model with the pore-scale information in the dNSTF cathode catalyst layer of the NM. It captures the special morphology of the partially ionomer/water covered cylindrical whiskers, as well as water percolation through the pore structures and their impact on the cell performance. Here we observe optimal ionomer coverage on whiskers to be 0.5, ionomer to carbon ratio to be 0.9 and higher whisker to carbon ratios to be desired.

08 HYDROGEN↗

Designing the Platinum Catalyst Layer for Improved Performance and Durability in Anion Exchange Membrane Water Electrolysis

To lower the cost of hydrogen produced by anion exchange membrane water electrolysis (AEMWE), it is critical to reduce the use of platinum group metal (PGM) catalysts within the device. While iridium has been successfully replaced with PGM-free catalysts at the anode, platinum-based (Pt) cathode catalysts are still required to meet the activity and durability targets. This study investigates the impact of commercial Pt/C catalyst loading, ionomer type and content, and electrode fabrication method on the cathode catalyst layer properties and AEMWE performance with the aim of determining the feasibility of reduced Pt loadings. While increased Pt loading is found to improve beginning-of-life performance, the effects are minimal above 0.6 mg/cm 2 . Ink characterization shows that ionomer type and content affect the ink stability, particle size, and percent of unbound ionomer, which further impact the homogeneity of the sprayed catalyst layers. The 5% PiperION cathode exhibited the highest performance, which may be attributed to a balance between the small particle size and the low proportion of unbound ionomer, minimizing kinetic and transport losses. Theoretical calculations show that the ionomers interact differently with the Pt surface, causing different surface charges and water adsorption strength and activating different mechanisms for hydrogen evolution. Pt-PiperION lowered the enthalpy of water-splitting by 0.1 eV compared to Pt alone and allowed for equal site access between adsorbed H* and OH* (both adsorbed at circa −2.2 eV). Although catalyst-coated membrane (CCM) fabrication techniques are desirable for scale-up, no performance enhancement is observed compared with the catalyst-coated substrate approach. Durability, as measured by degradation rates, Pt loss, and catalyst layer restructuring, was found to improve with increased Pt loadings, higher ionomer content, and CCM architectures. These findings provide important insight into the significant role of the cathode in AEMWE and strategies for maintaining the performance with low Pt loading or PGM-free catalysts.

08 HYDROGEN↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗