Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths

The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.

cryogenically cooled superconductorinsulator- supe↗

Measurements of the Low Frequency Gain Fluctuations of a 30 GHz High-Electron-Mobility-Transistor Cryogenic Amplifier

Low frequency gain fluctuations of a 30 GHz cryogenic HEMT amplifier have been measured with the input of the amplifier connected to a 15 K load. Effects of fluctuations of other components of the test set-up were eliminated by use of a power-power correlation technique. Strong correlation between output power fluctuations of the amplifier and drain current fluctuations of the transistors comprising the amplifier are observed. The existence of these correlations introduces the possibility of regressing some of the excess noise from the HEMT amplifier's output using the measured drain currents.

Jarosik, Norman↗

Optimisation of a multi-disk cryogenic amplifier for a high-intensity, high-repetition-rate laser system

Holders of the active elements of a multi-disk multipass amplifier with a liquid-free closed cryogenic cooling cycle are modified. The equilibrium temperature of the active elements is experimentally investigated in relation to the power of diode pumping for the modified crystal holders. The dependence of the gain coefficient on the temperature of the active elements is measured. A small-signal gain of up to 1.2 is obtained in a single pass through the active element. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of FD-SOI cryogenic amplifier for application to STJ readout in COBAND project

The COBAND is a project of an experimental search for the cosmic background neutrino decay [1] – [9] . The existence of the cosmic background neutrino is predicted as a relic of the big bang in the theoretical cosmology. Since the neutrino is found to have mass generations and mixing between them, a heavier neutrino is possible to decay to a lighter neutrino with a far-infrared photon, even though its lifetime is expected to be much longer than the age of the universe [10] . However, neither the cosmic background neutrino nor the neutrino decay is yet established experimentally. Only a lower limit in the order of 10 12 years is given on the heaviest neutrino lifetime. We, thus, search for photons which come from the cosmic background neutrino decays. The photons from the cosmic background neutrino decays are expected to shape a spectrum of a unique signature with a sharp edge at a wavelength of around 50μm depending on the heaviest neutrino mass. To identify the signature against the overwhelming zodiacal emission foreground as well as the cosmic infrared background, the photodetectors are required to have an ability to measure the FIR spectrum around 50pm with sufficient precision. Thus, we aim at developing a photodetector with capability of FIR photon-by-photon spectrometry. We employ superconducting tunnel junction (STJ) sensors in combination with cryogenic amplifiers for signal readout to maximize the potential of STJ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contactless method for studying temperature within the active element of a multidisk cryogenic amplifier

A new original method has been developed and experimentally implemented, allowing temperature fields to be contactlessly measured in the pump region of active elements in high-power-diode-pumped laser amplifiers, including those operating at cryogenic temperatures. The presence of a temperature gradient of ∼57 K mm{sup −1} along the pump beam axis at the centre of the active element of the laser amplification unit operating at cryogenic temperatures with a pulse repetition rate up to 1 kHz is simulated and experimentally confirmed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MOSFET's for Cryogenic Amplifiers

Study seeks ways to build transistors that function effectively at liquid-helium temperatures. Report discusses physics of metaloxide/semiconductor field-effect transistors (MOSFET's) and performances of these devices at cryogenic temperatures. MOSFET's useful in highly sensitive cryogenic preamplifiers for infrared astronomy.

Dehaye, R.↗

Performance of a wideband GaAs low-noise amplifier at cryogenic temperatures

The gain and noise figure performance of a GaAs amplifier at cryogenic temperatures has been studied. Results obtained indicate that a lower noise figure and a higher gain are induced by decreasing the temperature, while no significant change in the input 1-dB compression point is observed. Repeated temperature cycling had no adverse effect on the amplifier performance.

Toncich, S. S.↗

Nonlinear thermally induced distortions of a laser beam in a cryogenic disk amplifier

Taking into account the temperature dependences of the heat conductivity, the refractive index, and the thermal expansion coefficient, we calculated the temperature, elastic stresses, a thermally induced lens and depolarisation of a beam in a cryogenic disk amplifier (an Yb:YAG disk placed between a copper cylinder and a sapphire disk cooled by liquid nitrogen). When the active element (the thickness is 0.6 mm, the orientation is [001], the atomic concentration of Yb is 10%) is pumped by radiation from a diode laser (the beam diameter is 6 mm), the temperature does not exceed 140 K for the heat release power of 100 W. In this case, elastic stresses in the active element are six times lower than the maximum permissible value. The focal distance of the thermally induced lens is 5.5 m and the depolarisation rate is 0.038% per two passes through the active element. Although the heat conductivity of the active element rapidly decreases with temperature, the thermal load can be increased by 1.5-2 times when the dimensions of the active element remain constant. (active media)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 2.3-GHz cryogenically cooled HEMT amplifier for DSS 13

A prototype 2.3 GHz (S band) high electron mobility transistor (HEMT) amplifier/closed cycle refrigerator (CCR) system was installed in the DDS-13 feedcone, replacing the 2.3 GHz maser. The amplifier is cryogenically cooled to a physical temperature of 12 K and provides 31.5 K antenna system noise temperature and 29 dB of gain. The HEMT device used in the amplifier is a prototype.

Tanida, L.↗

An 8.4-GHz cryogenically cooled HEMT amplifier for DSS 13

A prototype 8.4 GHz (X-band) high electron mobility transistor (HEMT) amplifier/closed cycle refrigerator system was installed in the Deep Space Station 13 feedcone in August 1987. The amplifier is cryogenically cooled to a physical temperature of 12 K and provides 31 K antenna noise temperature (zenith) and 35 dB of gain at a frequency of 8.2 to 8.6 GHz. Antenna system noise temperature is less than 50 K from 7.2 to 9.4 MHz. The low noise HEMT amplifier system is intended for use as a radio astronomy or space communications receiver front end.

Tanida, L.↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

On 32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz High Electron Mobility Transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 K to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Bautista, J. J.↗

32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz high electron mobility transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Duh, K. H. George↗

Advanced components for spaceborne infrared astronomy

The need for improved cryogenic components to be used in future spaceborne infrared astronomy missions was identified. Improved low noise cryogenic amplifiers operated with infrared detectors, and better cryogenic actuators and motors with extremely low power dissipation are needed. The feasibility of achieving technological breakthroughs in both of these areas was studied. An improved silicon junction field effect transistor (JFET) could be developed if: (1) high purity silicon; (2) optimum dopants; and (3) very high doping levels are used. The feasibility of a simple stepper motor equipped with superconducting coils is demonstrated by construction of such a device based on a standard commercial motor. It is found that useful levels of torque at immeasurably low power levels were achieved. It is concluded that with modest development and optimization efforts, significant performance gains is possible for both cryogenic preamplifiers and superconducting motors and actuators.

Davidson, A. W.↗