Search NASA⌕ Search

SEARCH · Search NASA

Results for “Echelle Grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cooled echelle grating spectrometer

A cooled echelle grating spectrometer for detecting wavelengths between one micron and fifteen microns is disclosed. More specifically, the spectrometer has a cross-dispersing grating for ordering infrared energy and an echelle grating for further ordering of the infrared energy. Ordered radiation from the echelle grating is sensed by a detecting means. Also disclosed is use of a Schmidt camera for focusing the further ordered radiation from the echelle grating onto a detector array having individual detectors dispersed on a plane which substantially corresponds to a curved focal plane of the Schmidt camera. A spectrometer constructed according to the teachings of the present invention will continuously cover the spectrum between one micron and fifteen microns and have a resolution of 0.1/cm.

Beer, R.↗

Actual blaze angle of the Bausch & Lomb R4 echelle grating

An innovative procedure is described for measuring blaze angle that is free of systematic effects associated with an alternative approach. The method uses the effect of facet diffraction on the blaze function when an echelle grating is used off-Littrow. The angle measurement in the Littrow condition is wavelength independent and locates the actual direction of the grating facet normal.

Brown, R. A.↗

An ultraviolet spectrograph using an echelle grating with cross-disperser for the measurement of stratospheric constituents

The present investigation is concerned with the development of a high resolution echelle-cross disperser grating spectrograph for application in groundbased, balloon, and Shuttle studies of the middle atmosphere and thermosphere. All the design features discussed pertain specifically to the balloon instrument. Attention is given to examples of scientific objectives for the middle atmosphere, aspects of instrument description, imaging requirements, the spectral multiplexing capability, broad wavelength coverage, sensitivity, dynamic range, scattered light, the optical configuration of the instrument, the detector system, the data system, and the results of laboratory tests and theoretical evaluations.

Torr, D. G.↗

Efficiency functions for a 316 g/mm echelle grating

The radiometric response function of the High Resolution Spectrograph (HRS) for the Hubble Space Telescope was measured in 1984. From the system efficiency measurements made in the HRS echelle modes, the relative efficiencies ('ripple' functions) of 14 HRS echelle orders have been deduced. The results agree well with a theoretical model of echelle efficiency, except for a residual shift of apparent blaze angle with spectral order. The discrepancy between nominal and fitted blaze angle decreases with increasing order number.

Cushman, G. W.↗

SO2 Spectroscopy with A Tunable UV Laser

A portion of the fluorescence spectrum of SO2 has been studied using a narrow wavelength doubled dye laser as the exciting source. One purpose of this study is to evaluate the use of SO2 resonance re-emission as a probe of SO2 in the atmosphere. When the SO2 is excited by light at 300.2 nm, for example, a strong reemission peak is observed which is Stokes-shifted from the incident light wavelength by the usual Raman shift (the VI symmetric vibration frequency 1150.5/cm ). The intensity of this peak is sensitive to small changes (.01 nm) in the incident wavelength. Measurements of the N2 quenching and self quenching of this re-emission have been obtained. Preliminary analysis of this data indicates that the quenching is weak but not negligible. The dye laser in our system is pumped by a pulsed N2 laser. Tuning 'and spectral narrowing are accomplished using a telescope-echelle grating combination. In a high power configuration the resulting pulses have a spectral width of about 5 x 10(exp -3) nm and a time duration of about 6 nsec. The echelle grating is rotated by a digital stepping motor, such that each step shifts the wavelength by 6 x 10(exp -4) nm. In addition to the tunable, narrow wavelength uv source and spectral analysis of the consequent re-emission, the system also provides time resolution of the re-emitted light to 6 nsec resolution. This capability is being used to study the lifetime of low pressure S02 fluorescence at different wavelengths and pressures.

Morey, W. W.↗

Echelle efficiencies - Theory and experiment

The effect of one echelle spectrograph design factor, orientation of the incident light bundle, is examined. Comparison of theoretical calculations and experimental measurements of echelle grating efficiencies are given for R2 echelles used in three possible configurations: alpha greater than beta, alpha smaller than beta, and the quasi-Littrow mode. The throughput-resolution products for these various cases are also compared.

Schroeder, D. J.↗

Ion beam deposited silicon carbide on glass optics and replica gratings

The results of an attempt to coat optical flats and replace echelle gratings with ion-deposited SiC are reported. Deposition was performed by bombarding a SiC target with an ion beam angled 45 deg relative to the target. Half the target was covered with stainless steel to furnish a comparison opportunity. After precleaning SiC coatings of 300-2200 A thickness were deposited. The specimens had previously been coated with either Au or Al or were left blank. Reflectance and diffraction data were taken of the finished flats and gratings. The SiC-coated flats performed as well as uncoated flats while the echelles exhibited deteriorating performance with increasing coating thickness. Further studies are indicated on the effect of coating thickness on surface roughness.

Windt, D. L.↗

Electromagnetic diffraction efficiencies for plane reflection diffraction gratings

The theory and computer programs, based on electromagnetic theory, for the analysis and design of echelle gratings were developed. The gratings are designed for instruments that operate in the ultraviolet portion of the spectrum. The theory was developed so that the resulting computer programs will be able to analyze deep (up to 30 wavelengths) gratings by including as many as 100 real or homogeneous diffraction orders. The program calculates the complex amplitude coefficient for each of the diffracted orders. A check on the numerical method used to solve the integral equations is provided by a conservation of energy calculation.

Marathay, A. S.↗

Electromagnetic diffraction efficiencies for plane reflection diffraction gratings

Results are presented of research activities on holographic grating research. A large portion of this work was performed using rigorous vector diffraction theory, therefore, the necessary theory has been included in this report. The diffraction efficiency studies were continued using programs based on a rigorous theory. The simultaneous occurrence of high diffraction efficiencies and the phenomenon of double Wood's anomalies is demonstrated along with a graphic method for determining the necessary grating parameters. Also, an analytical solution for a grating profile that is perfectly blazed is obtained. The performance of the perfectly blazed grating profile is shown to be significantly better than grating profiles previously studied. Finally, a proposed method is described for the analysis of coarse echelle gratings using rigorous vector diffraction that is currently being developed.

Marathay, A. S.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

An FIR cooled grating spectrometer for the Kuiper Airborne Observatory

The design and performance of a liquid-He-cooled spectrometer being developed for the Kuiper Airborne Observatory (KAO) to study FIR lines originating in the interstellar medium are discussed. Currently, the spectrometer contains six Ge:Ga photoconductor detectors mounted in integrating cavities and cooled to about 3 K; the collimator focal plane has space for 39 such detectors. The instrument achieves a maximum resolving power of 6000 by means of a 45-cm long echelle grating and is optically capable of operating in the spectral range 25-300 microns. A laboratory spectrum of water vapor, an atmospheric water absorption feature measured from the KAO with Mars as a source, and the forbidden O(2+) emission from W51-IRS1 are shown.

Erickson, E. F.↗

The Scientific Impact of the GHRS on our Understanding of the Local Interstellar Medium

A high-resolution echelle grating and low-noise Digicon detectors make the GHRS an excellent instrument for studying ultraviolet absorption lines formed in the local interstellar medium (LISM). The GHRS has observed interstellar gas absorption along several dozen fines of sight toward stars; many of these stars are located within 100 pc of the Sun and thus sample the LISM properties quite well. We will summarize how the analysis of these beautiful echelle spectra permit us to study four important but closely interrelated topics about the LISM: (1) the dynamics and structure of the warm interstellar clouds, (2) the temperature, density, and other physical properties of the gas, (3) the chemical composition and chemical depletions in the gas phase, and (4) the interaction of the interstellar gas with the ionized hot winds of the Sun and other stars.

Linsky, Jeffrey L.↗

New Insights into the Chemical Composition of Five Oort Cloud Comets after Re-analysis of Their Infrared Spectra

We present revised results for the main molecular species in five Oort Cloud comets observed with near-infrared echelle grating spectrometer (NIRSPEC) at the Keck Observatory between 1999 and 2012 (C/1999 S4 (LINEAR), C/2001 A2 (LINEAR), C/2007 W1 (Boattini), C/2012 F6 (Lemmon), and C/2012 S1 (ISON)). The re-evaluation of these data shows the improvement of results in some of the data sets, in particular for comets observed and analyzed before the advent of new and revised fluorescence models and terrestrial retrieval methods introduced since 2011. We observe significant improvements in the resulting rotational temperatures and the production rates for all species, and in mixing ratios of minor species (relative to water). The re-analysis also allowed us to quantify species not analyzed previously, mostly due to the lack of molecular models (e.g., ammonia and formaldehyde). We note, however, that the improvement of these revised values is less substantial for comets observed (and/or analyzed) since 2010.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water vapor in Venus determined by airborne observations of the 8200 A band

The region of the 8200 A Band of H2O was studied in spectra of Venus obtained with an echelle grating spectrograph operated at an altitude of 14.6 km in the NASA Learjet research aircraft. Taking advantage of low foreground absorption, observing at a time of velocity quadrature, differential spectroscopy with respect to lunar spectra, and spectrum averaging, we establish a value of H2O of 3 plus or minus 20 microns for the total path over the entire disk. This value differs from earlier studies of the integrated disk but supports the low values recently derived from infrared bands and by very high spectral resolution groundbased studies.

Gull, T. R.↗