A Packaged Silicon MEMS Vibratory Gyroscope for Microspacecraft

In this paper, we present recent work on the design, fabrication, and packaging of a silicon MIcro-Electro-Mechanical System (MEMS) microgyroscope designed for space applications. A hermetically sealed package that houses the microgyroscope and most of its control electronics has been built and tested.

MEMS micro-electromechanical system microspacecraf↗

Non-inertial calibration of vibratory gyroscopes

The electrostatic elements already present in a vibratory gyroscope are used to simulate the Coriolis forces. An artificial electrostatic rotation signal is added to the closed-loop force rebalance system. Because the Coriolis force is at the same frequency as the artificial electrostatic force, the simulated force may be introduced into the system to perform an inertial test on MEMS vibratory gyroscopes without the use of a rotation table.

Gutierrez, Roman C.↗

Dynamics of vibratory microgyroscopes

In this report we provide a vectorial derivation of the equations of motion characterizing the dynamite behavior of both ideal and non-ideal vibratory micromachined gyroscopes.

MEMS gyroscopes vibratory gyroscopes↗

Split-resonator integrated-post MEMS gyroscope

A split-resonator integrated-post vibratory microgyroscope may be fabricated using micro electrical mechanical systems (MEMS) fabrication techniques. The microgyroscope may include two gyroscope sections bonded together, each gyroscope section including resonator petals, electrodes, and an integrated half post. The half posts are aligned and bonded to act as a single post.

Bae, Youngsam↗

Continuous Tuning and Calibration of Vibratory Gyroscopes

A method of control and operation of an inertial reference unit (IRU) based on vibratory gyroscopes provides for continuously repeated cycles of tuning and calibration. The method is intended especially for application to an IRU containing vibratory gyroscopes that are integral parts of microelectromechanical systems (MEMS) and that have cloverleaf designs, as described in several previous NASA Tech Briefs articles. The method provides for minimization of several measures of spurious gyroscope output, including zero-rate offset (ZRO), angle random walk (ARW), and rate drift. These benefits are afforded both at startup and thereafter during continuing operation, in the presence of unknown rotation rates and changes in temperature. A vibratory gyroscope contains a precision mechanically resonant structure containing two normal modes of vibration nominally degenerate in frequency and strongly coupled via a Coriolis term. In the case of the cloverleaf design MEMS gyro, these normal modes of vibration are plate rocking modes. The rocking motion of the plate is described by giving two angles, theta(sub 1) and theta(sub 2). A proof mass consisting of a post orthogonal to the plate ensures a high degree of Coriolis coupling of vibratory energy from one mode into the other under inertial rotation. The plate is driven and sensed capacitively across a few-microns-wide gap, and the normal mode frequencies can be tuned electrostatically by DC voltages applied across this gap. In order to sense rotation, the resonator plate is caused to rock in the theta(sub 1) direction, then any small motions in the theta(sub 2) direction are sensed, rebalanced, and interpreted as inertial rotation. In this scenario, the "drive" has been assigned to the theta(sub 1) direction, and the "sense" has been assigned to the theta(sub 2) direction.

Hayworth, Ken↗

Making Precise Resonators for Mesoscale Vibratory Gyroscopes

An alternative approach to the design and fabrication of vibratory gyroscopes is founded on the use of fabrication techniques that yield best results in the mesoscopic size range, which is characterized by overall device dimensions of the order of a centimeter. This approach stands in contradistinction to prior approaches in (1) the macroscopic size range (the size range of conventional design and fabrication, characterized by overall device dimensions of many centimeters) and (2) the microscopic size range [the size range of microelectromechanical systems (MEMS), characterized by overall device dimensions of the order of a millimeter or less]. The mesoscale approach offers some of the advantage of the MEMS approach (sizes and power demands smaller than those of the macroscale approach) and some of the advantage of the macroscale approach (the possibility of achieving relative dimensional precision greater than that of the MEMS approach). Relative dimensional precision is a major issue in the operation of a vibratory gyroscope. The heart of a vibratory gyroscope is a mechanical resonator that is required to have a specified symmetry in a plane orthogonal to the axis about which rotation is to be measured. If the resonator could be perfectly symmetrical, then in the absence of rotation, a free vibration of the resonator could remain fixed along any orientation relative to its housing; that is, the gyroscope could exhibit zero drift. In practice, manufacturing imprecision gives rise to some asymmetry in mass, flexural stiffness or dissipation, resulting in a slight drift or beating motion of an initial vibration pattern that cannot be distinguished from rotation. In the mesoscale approach, one exploits the following concepts: For a given amount of dimensional error generated in manufacturing, the asymmetry and hence the rate-of-rotation drift of the gyroscope can be reduced by increasing the scale. The decrease in asymmetry also reduces coupling of vibrations to the external environment. Mechanical thermal noise and electronic measurement noise and drift can also be reduced by increasing the size of the resonator and its associated sensors.

Yang, Eui-Hyeok↗

MEMS metal-quartz gyroscope

The present disclosure relates to a gyroscope that makes use of a shuttle having a first plurality of fingers, a stator having a second plurality of fingers, at least one fixed support structure, and a plurality of flexors for supporting the shuttle for vibratory motion relative to the stator. The fingers of the shuttle are able to move in a vibratory motion adjacent the fingers of the stator without contacting the fingers of the stator. Portions of the fingers of at least one of the shuttle and the stator also make use of a grounded metal material layer to reduce parasitic capacitive coupling between the fingers of the shuttle and the fingers of the stator.

Park, Sangtae↗

Disc resonator gyroscope fabrication process requiring no bonding alignment

A method of fabricating a resonant vibratory sensor, such as a disc resonator gyro. A silicon baseplate wafer for a disc resonator gyro is provided with one or more locating marks. The disc resonator gyro is fabricated by bonding a blank resonator wafer, such as an SOI wafer, to the fabricated baseplate, and fabricating the resonator structure according to a pattern based at least in part upon the location of the at least one locating mark of the fabricated baseplate. MEMS-based processing is used for the fabrication processing. In some embodiments, the locating mark is visualized using optical and/or infrared viewing methods. A disc resonator gyroscope manufactured according to these methods is described.

Shcheglov, Kirill V.↗

Isolated post resonator mesogyroscope

A new symmetric vibratory gyroscope principle has been devised in which a central post proof mass is counter-rocked against an outer sensing plate such that the motion is isolated from the gyroscope case. Prototype gyroscopes have been designed and fabricated with micromachined silicon at mesoscale (20-cm resonator width), vs. microscale (e.g., 2-mm resonator width) to achieve higher sensitivity and machined precision. This novel mesogyro design arose out of an ongoing technical cooperation between JPL and Boeing begun in 1997 to advance the design of micro-inertial sensors for low-cost space applications. This paper describes the theory of operation of the mesogyro and relationships with other vibratory gyroscopes, the mechanical design, closed loop electronics design, bulk silicon fabrication and packaged gyroscope assembly and test methods. The initial packaged prototype test results are reported for what is believed to be the first silicon mesogyroscope.

mesogyroscope↗

NASA Tech Briefs, June 2004

Topics covered include: COTS MEMS Flow-Measurement Probes; Measurement of an Evaporating Drop on a Reflective Substrate; Airplane Ice Detector Based on a Microwave Transmission Line; Microwave/Sonic Apparatus Measures Flow and Density in Pipe; Reducing Errors by Use of Redundancy in Gravity Measurements; Membrane-Based Water Evaporator for a Space Suit; Compact Microscope Imaging System with Intelligent Controls; Chirped-Superlattice, Blocked-Intersubband QWIP; Charge-Dissipative Electrical Cables; Deep-Sea Video Cameras Without Pressure Housings; RFID and Memory Devices Fabricated Integrally on Substrates; Analyzing Dynamics of Cooperating Spacecraft; Spacecraft Attitude Maneuver Planning Using Genetic Algorithms; Forensic Analysis of Compromised Computers; Document Concurrence System; Managing an Archive of Images; MPT Prediction of Aircraft-Engine Fan Noise; Improving Control of Two Motor Controllers; Electro-deionization Using Micro-separated Bipolar Membranes; Safer Electrolytes for Lithium-Ion Cells; Rotating Reverse-Osmosis for Water Purification; Making Precise Resonators for Mesoscale Vibratory Gyroscopes; Robotic End Effectors for Hard-Rock Climbing; Improved Nutation Damper for a Spin-Stabilized Spacecraft; Exhaust Nozzle for a Multitube Detonative Combustion Engine; Arc-Second Pointer for Balloon-Borne Astronomical Instrument; Compact, Automated Centrifugal Slide-Staining System; Two-Armed, Mobile, Sensate Research Robot; Compensating for Effects of Humidity on Electronic Noses; Brush/Fin Thermal Interfaces; Multispectral Scanner for Monitoring Plants; Coding for Communication Channels with Dead-Time Constraints; System for Better Spacing of Airplanes En Route; Algorithm for Training a Recurrent Multilayer Perceptron; Orbiter Interface Unit and Early Communication System; White-Light Nulling Interferometers for Detecting Planets; and Development of Methodology for Programming Autonomous Agents.

Source record↗

A Highly Miniaturized Inertial Grade Gyroscope for Space Applications

The evolution of inertial grade gyroscopes for space applications represents well over 50 years of technology development and an investment of hundreds of millions of dollars. The workhorse product which represents the current state-of-the art for commercially available high performance devices is the Litton-Hemishperical Resonator Gyro (HRG) Inertial Measurement Unit (IMU). This product has a performance figure of merit of 0.003 deg/hr bias drift, a volume of 567 cubic inches, weighs 19 pounds, draws about 30 watts and costs over $1 million each. Clearly devices of this magnitude are not conducive to the minimized mass, volume, power, and cost constraints of outer planet missions. An approach to breaking these potential barriers is the use of Microelectromechanical Systems (MEMS) based inertial devices. Although substantially reduced in size, mass power and cost, this approach has produced devices in the tactical performance range of greater than 1 deg/hour bias drift. This level of performance satisfies the preponderance of high market volume requirements such as automotive and tactical munitions but does not meet the limited market quantity requirements for the high precision space based market. Because of the very limited size of the space based market, there is little economic incentive for commercial fabricators of tactical grade devices to address the necessary performance improvements. The Jet Propulsion Laboratory (JPL) in conjunction with Boeing Space Systems (BSS) is addressing this void to satisfy our mutual requirements in this area. The project objective to is to achieve 0.01 deg/hr performance in an IMU which is less than 10 cubic inches in volume, weighs less than 0.5 pounds, draws less than 1 watt and is available in volume production for less than $2500. Reductions of this magnitude will be mission enabling capabilities for a variety of anticipated outer planet mission attributes such as autonomous control and docking, formation flying and robotic outposts. The improved performance will be realized using improved relative precision fabrication, enhanced vibratory drive and sense designs, and statistical data analysis.

Wiberg, D. V.↗