Search NASASearch

SEARCH · Search NASA

Results for “Microplasma ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics

Development and application of a 3-D geometry/mass model for LDEF satellite ionizing radiation assessments

A computer model of the three dimensional geometry and material distributions for the LDEF spacecraft, experiment trays, and, for selected trays, the components of experiments within a tray was developed for use in ionizing radiation assessments. The model is being applied to provide 3-D shielding distributions around radiation dosimeters to aid in data interpretation, particularly in assessing the directional properties of the radiation exposure. Also, the model has been interfaced with radiation transport codes for 3-D dosimetry response predictions and for calculations related to determining the accuracy of trapped proton and cosmic ray environment models. The methodology is described used in developing the 3-D LDEF model and the level of detail incorporated. Currently, the trays modeled in detail are F2, F8, and H12 and H3. Applications of the model which are discussed include the 3-D shielding distributions around various dosimeters, the influence of shielding on dosimetry responses, and comparisons of dose predictions based on the present 3-D model vs those from 1-D geometry model approximations used in initial estimates.

B. L. Colborn

Material-dependent photon ionizing radiation effects in Si and GaAs PIN diodes: A numerical investigation

We present a finite-element drift-diffusion-Poisson model in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework to compare the radiation response of silicon (Si) and gallium arsenide (GaAs) PIN diodes under high-energy photon irradiation. The model solves coupled carrier continuity and Poisson’s equations with Shockley-Read-Hall recombination, and is verified against standard analytical J-V behavior. Using a simplified 1D geometry with ideal Ohmic contacts, we quantify device response under forward and reverse bias with a 100 MeV photon flux. Under forward bias, Si exhibits markedly greater radiation sensitivity than GaAs, including larger increases in current density, stronger local field and carrier-product perturbations, and higher recombination. Under reverse bias, GaAs shows larger radiation-induced photocurrent and broader current-density peaks near junctions, indicating an advantage for photodetection. Integrated steady-state recombination is consistently higher in Si across voltages. Under periodic photon pulses, GaAs produces higher-amplitude photoresponse and settles more rapidly than Si. These results highlight material-dependent trade-offs for radiation-tolerant, high-speed optoelectronics and provide guidance for selecting PIN architectures in aerospace, nuclear, and high-energy physics environments.

36 MATERIALS SCIENCE

Evidence for the Interaction of the IRS 16 Wind With the Ionized and Molecular Gas at the Galactic Center

We present a number of high-resolution radio images showing evidence for the dynamical interaction of the outflow arising from the IRS 16 complex with the ionized gas associated with the Northern Arm of Sgr A West, and with the northwestern segment of the circumnuclear molecular disk which engulfs the inner few parsecs of the Galactic center. These interactions offer an opportunity to explain some important aspects of the complex morphology of ionized and molecular gas at the Galactic center. In particular we suggest that the wind disturbs the dynamics of the Northern Arm within 0.1 pc of the center, is responsible for the waviness of the arm at larger distances and is collimated by Sgr A West and the circumnuclear disk. The waviness is discussed in terms of the Rayleigh-Taylor instability induced by the ram pressure of the wind incident on the surface of the Northern Arm. Another consequence of this interaction is the strong mid IR polarization of the Northern Arm in the vicinity of the IRS 16 complex which is explained as a result of the ram pressure of the wind compressing the gas and the magnetic field. The IRS 16 complex must therefore lie close to the Northern Arm. On a large scale we argue that the wind has swept up the diffuse material in the inner parsec of the Galactic center and that the interaction with the inner part of the northwestern part of the circumnuclear ring is responsible for the H 2 v = 1-0 emission and the ionized streamers. Lastly, we discuss the possibility that the outflow from IRS 16 could be responsible for eating away the inner edge of the circumnuclear disk and provide friction needed for the infall of the material in the arms of Sgr A West.

IRS 16

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Conformer-Specific Dissociation Dynamics in Dimethyl Methylphosphonate Radical Cation

The dynamics of the dimethyl methylphosphonate (DMMP) radical cation after production by strong field adiabatic ionization have been investigated. Pump-probe experiments using strong field 1300 nm pulses to adiabatically ionize DMMP and a 800 nm non-ionizing probe induce coherent oscillations of the parent ion yield with a period of about 45 fs. The yields of two fragments, PO 2 C 2 H 7 + and PO 2 CH 4 + , oscillate approximately out of phase with the parent ion, but with a slight phase shift relative to each other. We use electronic structure theory and nonadiabatic surface hopping dynamics to understand the underlying dynamics. The results show that while the cation oscillates on the ground state along the P=O bond stretch coordinate, the probe excites population to higher electronic states that can lead to fragments PO 2 C 2 H 7 + and PO 2 CH 4 + . The computational results combined with the experimental observations indicate that the two conformers of DMMP that are populated under experimental conditions exhibit different dynamics after being excited to the higher electronic states of the cation leading to different dissociation products. These results highlight the potential usefulness of these pump-probe measurements as a tool to study conformer-specific dynamics in molecules of biological interest.

59 BASIC BIOLOGICAL SCIENCES

Nuclear Physics Made Very, Very Easy

The fundamental approach to nuclear physics was prepared to introduce basic reactor principles to various groups of non-nuclear technical personnel associated with NERVA Test Operations. NERVA Test Operations functions as the field test group for the Nuclear Rocket Engine Program. Nuclear Engine for Rocket Vehicle Application (NERVA) program is the combined efforts of Aerojet-General Corporation as prime contractor, and Westinghouse Astronuclear Laboratory as the major subcontractor, for the assembly and testing of nuclear rocket engines. Development of the NERVA Program is under the direction of the Space Nuclear Propulsion Office, a joint agency of the U. S. Atomic Energy Commission and the National Aeronautics and Space Administration. This report is being reprinted for use in the U. S. Atomic Energy Commission and National Aeronautics and Space Administration educational and technology utilization programs.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

An Accreting Supermassive Black Hole Buried in a Faint Dwarf Galaxy

Abstract In the last decade, there have been several discoveries of active galactic nuclei (AGN) in dwarf galaxies including an AGN in an ultracompact dwarf galaxy with a black hole mass >10 6 M ⊙ . However, finding a supermassive black hole (SMBH) in a dwarf low surface brightness (LSB) galaxy is rare. We report the discovery of a Seyfert type 2 class AGN that is associated with a nuclear SMBH of mass ∼6.5 × 10 6 M ⊙ in a dwarf LSB galaxy (μ 0,r > 23.8 mag arcsec −2 ) that we denote by MJ0818+2257. The galaxy was previously thought to be an outlying emission blob around the large spiral galaxy LEDA 1678924. In our current analysis, which includes the detection of the optical counterpart of MJ0818+2257, we study its ionized gas kinematics and find that the dynamical mass within the ionized gas disk is ∼5.3 × 10 9 M ⊙ . This is comparable to its stellar mass, which is ∼3 × 10 9 M ⊙ , and suggests that MJ0818+2257 is moderately dark matter dominated within the stellar disk. The SMBH-mass-to-galaxy-stellar-mass ratio isM BH /M(*) > 0.022, which is high compared to disk galaxies. Our detection of an SMBH in a bulgeless LSB dwarf galaxy raises questions about the growth of SMBHs in low-luminosity galaxies and suggests the possibility of detecting heavy seed black holes from early epochs in LSB dwarf galaxies in the low-redshift Universe.

Astronomy & Astrophysics

The Slow Demise of the Long-Lived Sn 2005ip

The Type IIn supernova (SN IIn) 2005ip is one of the most well-studied and long-lasting examples of an SN interacting with its circumstellar environment. The optical light curve plateaued at a nearly constant level for more than five years, suggesting ongoing shock interaction with an extended and clumpy circumstellar medium (CSM). Here, we present continued observations of the SN from ∼1000 to 5000 d post-explosion at all wavelengths, including X-ray, ultraviolet, near-infrared (NIR), and mid-infrared. The UV spectra probe the pre-explosion mass loss and show evidence for CNO processing. From the bolometric light curve, we find that the total radiated energy is in excess of 10 50 erg, the progenitor star’s pre-explosion mass-loss rate was >~ 1 × 10 −2 Mꙩ yr −1 , and the total mass lost shortly before explosion was >~1Mꙩ, though the mass lost could have been considerably larger depending on the efficiency for the conversion of kinetic energy to radiation. The ultraviolet through NIR spectrum is characterized by two high-density components, one with narrow high-ionization lines, and one with broader low-ionization H I, He I, [OI], Mg II, and Fe II lines. The rich Fe II spectrum is strongly affected by Lyα fluorescence, consistent with spectral modelling. Both the Balmer and He I lines indicate a decreasing CSM density during the late interaction period. We find similarities to SN 1988Z, which shows a comparable change in spectrum at around the same time during its very slow decline. These results suggest that, at long last, the shock interaction in SN 2005ip may finally be on the decline.

stars