Search NASA⌕ Search

SEARCH · Search NASA

Results for “PEFC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Corrosion-Resistant Non-Carbon Electrocatalyst Supports for PEFCS

Insufficient durability of commercial catalysts is a persistent issue for PEFC applications.1 Herein, Pt on Nb-doped-TiO 2 is reported as a highly durable electrocatalyst on which the direct 4-electron reduction of oxygen to water is more facile compared to Pt/C. All performance metrics are reported comparing Pt/Nb-TiO2 with a 15% Pt loading, against a commercial Pt/C catalyst (46.5% Pt loading, Tanaka, K. K.). Nb-doped-TiO 2 with high surface area and high electronic conductivity was synthesized using the supercritical fluid method. Initially, the durability of the catalyst was characterized using accelerated stability tests (ASTs) involving 10,000 high potential cycles (DOE/FCCJ protocol) and the Pt/Nb-TiO 2 was found to retain 78% of its initial electrochemically active surface area (ECSA) compared to the 57.6 % retained by Pt/C. These observations were in excellent agreement with previous reports that the Pt particle size of Pt/C grew from 2nm to 8nm during the AST protocol along with severe corrosion and amorphization of the carbon surface.2, 3 TEM and XPS studies of the Pt-Nb-doped-TiO 2 catalyst showed that the Pt particle size grew from 3nm to 6nm and the Nb(IV) and Ti(III) in the support were oxidized to Nb(V) and Ti(IV) after the durability test. Thus, the improvement in Pt/Nb-TiO 2 ECSA retention was attributed to the lower extent of particle growth and lack of oxidative support loss upon oxidation as compared to Pt/C. The oxygen reduction reaction (ORR) performance was characterized by linear polarization using a rotating disk electrode (RDE). The electrochemical surface areas of Pt/Nb-TiO 2 and Pt/C were found to be 48m2·g -1 and 83m2·g -1 respectively, and the mass activity for the ORR at 0.9V vs. RHE were found to be 150 mA·mg-1Pt and 124 mA·mg-1Pt respectively. The improved mass activity on Pt/Nb-TiO 2 was attributed to strong metal support interaction (SMSI) between the Nb-TiO 2 support and the Pt catalyst based on the 625 meV decrease in the binding energy of the Pt4f x-ray photo-electron spectroscopy (XPS) peaks of Pt/Nb-TiO 2 compared to Pt/C. To quantify the impact of the SMSI, a kinetic model was applied to calculate the elementary reaction rate constants for the various steps of the ORR on both catalysts. The reaction rate constant (k1) for the direct 4-electron transfer pathway to produce H 2 O was significantly larger in Pt/Nb-TiO 2 as compared to Pt/C. Thus, the reduction in the electron binding energy as observed in the XPS was found to aid the facile filling of the higher energy 2p orbitals of O 2 thereby leading to improved 4-electron transfer kinetics and improved overall activity.

08 HYDROGEN↗

High Performance PEFC Electrode Structures

Raytheon Technologies Research Center (RTRC) in collaboration with Ion Power Inc. and the University of Arkansas at Little Rock and the FC-PAD consortium executed a project that: (1) developed comprehensive models of oxygen and proton transport in cathode catalyst layers that provided new insights about losses associated with reducing platinum loading to 0.1 mg/cm 2 , (2) designed, fabricated, characterized, and tested cells featuring carbon-supported catalyst layers with low platinum loadings that met efficiency and power density targets set forth by the Hydrogen and Fuel Cells Technology Office, and (3) designed, fabricated, characterized, and tested novel catalyst structures. The modeling efforts produced eight scientific publications that shared new descriptions of oxygen and proton transport in catalyst layers with the broader technical community. The key physical insights from the models are expressed in straightforward algebraic expressions, facilitating easy adoption by other researchers. The models developed during the project explain why resistance to oxygen transport is inversely proportional to interfacial area of platinum – an observation that eluded quantitative explanation for a decade. The models quantitatively predict polarization when measured morphological parameters and transport properties are input. Membrane-electrode assemblies made during the project met stated goals for current at high voltage and power density at rated voltage for transportation fuel cells at the end of budget period 2. High performance was achieved by developing a diffusion layer with low resistance to oxygen transport and a PtCo/C cathode catalyst layer capable of supporting rapid proton and oxygen transport. The project was subsequently directed to curtail experimental work and focus on modeling during budget period 3. Ion Power Inc. developed new expertise in fabricating catalyst layers containing platinum-cobalt catalysts, and processing very thin membranes. The University of Arkansas at Little Rock developed novel nanocolumnar self-supported thin film electrocatalysts that can be grown on carbon supports using a simple high pressure sputter deposition method. The nanocolumnar microstructure provides adequate surface-to-volume ratio for efficient platinum utilization, and the conformal platinum shell with larger crystal grain sizes covering the carbon support surface may eliminate durability issues associated with catalyst dissolution, agglomeration, and carbon corrosion.

08 HYDROGEN↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Advanced PGM-free Cathode Engineering for High Power Density and Durability

Polymer electrolyte fuel cells (PEFCs) are among the most promising technologies for future electric vehicles by using clean H2 with much-improved energy conversion efficiency, longer range, and rapid refueling. However, due to a large amount of platinum group metal (PGM) catalyst used in their electrodes, their prohibitively high cost hinders broad commercialization of PEFCs for transportation. Therefore, there is a critical need to develop low-cost, high-performance PGM-free cathode catalysts that have the potential to dramatically transform the economics of PEFC commercialization by reducing catalyst costs by one to two orders of magnitude. However, before PGM-free cathodes become viable, several technical challenges associated with PGM-free cathodes must be addressed, including insufficient activity and stability of the catalysts, as well as severe water flooding and large transport losses in the electrodes. Overcoming those barriers and ultimately meeting the challenging automotive PEFC performance targets was the focus of this comprehensive research and development effort on new PGM-free cathodes. To this end, we assembled a team including leading researchers from universities and industry with different but complementary expertise and capabilities. The project combined three novel and promising approaches: Advanced metal-organic framework (MOF)-derived M-N-C catalysts with a high activity and impressive durability, Novel PGM-free specific cathode architectures and fabrication strategies capable of addressing the substantial flooding and transport resistances in thicker cathodes by introducing engineered hydrophobicity through additives and support layers, and Advanced electrode ionomers with high proton conductivity for low ohmic losses across the electrode and more uniform catalyst utilization. The implementation of these new materials and electrode designs was supported by a suite of advanced experimental and simulation tools that allows us to identify performance and durability bottlenecks, devise solutions, and establish rational material design and synthesis targets. These methods include advanced electrochemical characterization, high-resolution imaging, and multi-scale modeling. In addition, the project team leveraged a broad cross-section of the ElectroCat consortium’s national laboratory facilities and expertise in advancing these materials and design strategies. Finally, the industry partners on the project facilitated the evaluation of scaled-up synthesis and manufacturing in the United States. Over its four-year period, the project made significant year-over-year advances in PGM-free cathode performance and viability. A combination of high activity and highly durable catalysts were developed through novel catalyst synthesis strategies, which met several performance and durability targets. More specifically, a catalyst prepared from MOFs and Fe2O3 nanoparticles with ammonium chloride and chemical vapor deposition treatments yielded a significant advancement in PGM-free cathode durability. Several novel strategies for fabricating cathodes were demonstrated, including those designed to reduce flooding and thickness of the cells for significantly increased volumetric power density. An optimized cathode with high conductivity ionomer and tuned ink processing for hydrophobicity yielded high fuel cell performance with new levels power density and maximum current. The scientific studies and modeling assessment also provided an outlook for future efforts, including a focus on catalysts with an increased density of the highly stable active sites developed in this project.

08 HYDROGEN↗

Durability of Pt-Alloy Catalyst for Heavy-Duty Polymer Electrolyte Fuel Cell Applications under Realistic Conditions

As an emerging technology, polymer electrolyte fuel cells (PEFCs) powered by clean hydrogen can be a great source of renewable power generation with flexible utilization because of high gravimetric energy density of hydrogen. To be used in real-life applications, PEFCs need to maintain their performance for long-term use under a wide range of conditions. Therefore, it's important to understand the degradation of the PEFC under protocols that are closely related to the catalyst lifetime. Alloying Pt with transitional metal improves catalyst activity. It is also crucial to understand Pt alloys degradation mechanisms to improve their durability. To study durability of Pt alloys, accelerated stress tests (ASTs) are performed on Pt-Co catalyst supported on two types of carbon. Two different AST protocols were being studied: Membrane Electrolyte Assembly (MEA) AST based on the protocol introduced by the Million Mile Fuel Cell Truck consortium in 2023 and Catalyst AST, adopted from the U.S. Department of Energy (DoE).

25 ENERGY STORAGE↗

Hierarchical low Pt-loading “core-shell” electrocatalysts for the oxygen reduction reaction in fuel cells

The sluggish kinetics of the oxygen reduction reaction (ORR) hinder cost-effective polymer electrolyte fuel cells (PEFCs), which rely on scarce, expensive platinum-based electrocatalysts (ECs). Here, we present a novel synthesis method for ORR ECs achieving exceptional platinum utilization. The design features a hierarchical “multi-carbon” support comprising carbon nanoparticles interacting with graphene nanoplatelets as the “core”, encapsulated by a porous carbon nitride (CN) “shell”. This configuration promotes strong core/shell interactions and a bimodal active site distribution, consisting of chemically dispersed Pt and Ni single-atom complexes and PtNix alloy nanoclusters embedded in the CN shell. These advantages enable high activity and durability, achieving an ORR activity of 1.6 A mgPt−1 at 0.9 V vs. RHE-an order of magnitude higher than Pt/C (0.17 A mgPt−1). A proof-of-concept PEFC demonstrates a specific power of 12.0 kW gPt−1 at 0.60 V. This approach offers a significant step toward more efficient and sustainable PEFC technologies.

Pagot, Gioele [University of Padova, Italy]↗

Durability evaluation of a Fe–N–C catalyst in polymer electrolyte fuel cell environment via accelerated stress tests

In this work, an “atomically-dispersed” iron-nitrogen-carbon (Fe–N–C) catalyst was used to provide a systematic comparison of platinum group metal (PGM)-free electrocatalyst degradation as a function of accelerated stress tests (ASTs) in an acidic polymer electrolyte fuel cell (PEFC). It was determined that the majority of catalyst degradation was caused by cell operation in presence of O 2 . In contrast, potential cycling of the Fe–N–C-containing cathode under inert atmosphere over typical PEFC cathode operation from 0.95 to 0.6 V had little to no effect. The increase in kinetic overpotential is shown to be the major source of the PEFC performance decrease during the ASTs. These results continue to showcase the need for development of robust PGM-free electrocatalysts in concert with improved electrochemical performance.

25 ENERGY STORAGE↗

3D Printed Carbon Aerogels for Polymer-Electrolyte Fuel Cells

Carbon aerogels (CA) are known for ultra-low density, very high surface area, fine porous structure, and excellent electrical conductivity. Recent advances in high resolution 3D printing at LLNL enable the manufacturing of complex structured CA electrodes which have been demonstrated in electrolysis, flow battery, and supercapacitor applications. Polymer-electrolyte fuel cells (PEFC) may be an excellent candidate for these materials/methods as designers seek to optimize membrane-electrode assemblies to achieve higher efficiencies. A major challenge to PEFC design is two-phase flow due to water production which causes pore flooding and leads to cell instability and degradation. To mitigate these effects, groups have investigated the creation of liquid specific pathways in the porous layers to alleviate liquid buildup and enhance gas diffusion. While some progress has been made, traditionally manufactured GDLs, which consist of randomly distributed carbon fibers, are limiting. 3D printed CAs are a promising solution as complex macroporous electrode structures can be manufactured out of micro and nano porous filaments with a high level of control. Additionally, the process may allow for the consolidation of multiple layers (MPL, GDL, & flow channels) into a single printed architecture. In this work various CA lattice structures were printed using a direct ink write (DIW) method and liquid breakthrough pressures were measured to demonstrate the ability to tune the water pathways to achieve specific pressure thresholds. Furthermore, a discussion of the prospects for printed CA electrodes in PEFC will focus on material properties, synthesis techniques, and current challenges.

36 MATERIALS SCIENCE↗

Modeling Nanoscale Ohmics in Carbon Supports of Fuel Cell Cathodes

Here, reducing platinum (Pt) loading in polymer electrolyte fuel cells (PEFCs) while meeting performace requirements is critical to their widespread deployment. However, significant polarization losses manifest at higher current densities in cathodes with lower Pt content. The morphology of the carbon supports in PEFC cathodes affects the location of Pt deposition into the micropits or onto the surface of the carbon support, translating into different kinetic and transport resistances. In this work, we derive an agglomerate scale model that differentiates the sink terms for Pt on the surface and in the pits of carbon supports. We develop an approach to assess the impact of nanoscale ohmic resistance to Pt in the micropits arising from weakly ionic solution in the carbon support on PEFC performance. Effectiveness factors relating the actual reaction rate to the maximum reaction rate (had all the Pt been exposed) are derived and embedded into a one-dimensional catalyst layer model. Parameters in the catalyst layer model are tuned based on experimental local oxygen transport resistances. Subsequently, we estimate bounds for the micropore resistances based on geometric and physical arguments. Lastly, polarization curves are simulated to assess the effect of the micropore resistance in fully-humidified and oxygen-rich environments.

25 ENERGY STORAGE↗

Effect of Commercial Gas Diffusion Layers on Catalyst Durability of Polymer Electrolyte Fuel Cells in Varied Cathode Gas Environment

Gas diffusion layers (GDLs) play a crucial role in heat transfer and water management of cathode catalyst layers in polymer electrolyte fuel cells (PEFCs). Thermal and water gradients can accelerate electrocatalyst degradation and therefore the selection of GDLs can have a major influence on PEFC durability. Currently, the role of GDLs in electrocatalyst degradation is poorly studied. Here, we perform electrocatalyst accelerated stress test studies on membrane electrode assemblies (MEAs) prepared using three most commonly used GDLs. The effect of GDLs on electrocatalyst degradation is evaluated in both nitrogen (non-reactive) and air (reactive) gas environments at 100% relative humidity. In situ electrochemical characterization and extensive physical characterization is performed to understand the subtle differences in electrocatalyst degradation and correlated to the use of different GDLs. Overall, no difference is observed in the electrocatalyst degradation due to GDLs based on polarization curves at the end of life. But interestingly, MEA with a cracked microporous layer (MPL) in the GDL exhibited a higher electrocatalyst loading loss, which resulted in a lower and more heterogeneous increase in the average electrocatalyst nanoparticle size.

25 ENERGY STORAGE↗

Tailoring electrode microstructure via ink content to enable improved rated power performance for platinum cobalt/high surface area carbon based polymer electrolyte fuel cells

Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .

25 ENERGY STORAGE↗

Adaptive learning-driven high-throughput synthesis of oxygen reduction reaction Fe–N–C electrocatalysts

Reducing human reliance on inefficient energy systems and fossil fuels has become more urgent due to the consequences of global climate change. However, traditional trial-and-error approaches have hampered our ability to accelerate the discovery and implementation of functional materials for efficient energy conversion devices, such as polymer electrolyte fuel cells (PEFCs). To address this, we develop an adaptive learning framework that integrates machine learning and state-of-the-art capabilities in high-throughput synthesis to achieve expedited optimization of iron-nitrogen-carbon PEFC oxygen reduction reaction (ORR) electrocatalysts. We use statistical inference, uncertainty quantification, and global optimization to build a computational design-of-experiment tool that identifies the optimum compositions to be investigated next to reduce the demands placed on experimental materials discovery. We benchmark the ability of the proposed strategy to discover optimum catalyst synthesis conditions in a six-dimensional search space when starting with a thirty-six-sample database. By following the adaptive learning strategy, we synthesize fourteen new catalysts from approximately ten billion unique compositions and discover four catalysts that outperform all original samples. The best machine learning-optimized catalyst is 33% more active than the highest-performing one in the initial database, showing an ORR activity seven times larger than those typically reported for the same class of materials.

36 MATERIALS SCIENCE↗

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics↗

Understanding Platinum Ionomer Interface Properties of Polymer Electrolyte Fuel Cells

A well-designed cathode catalyst layer with optimal ionomer distribution is critical to minimizing amount of Platinum (Pt) content in polymer electrolyte fuel cells (PEFCs). The impact of Pt loading, ionomer content and carbon support types on the catalyst/ionomer interface were also investigated at dry and wet conditions. Higher Pt loadings resulted in higher double layer capacity (C dl ) and similar electrochemical surface area (ECSA) due to well dispersed ionic phase material. Higher ionomer content resulted in higher ionic conductivity but also showed similar SO 3 − group coverage. High surface area (HSA) carbon support had larger ECSA and C dl at both dry and wet conditions, as less agglomerated Pt was well dispersed in the meso-pores of the support. Lower SO 3 − group coverages were observed for HSA carbon than for Vulcan carbon due to Pt particles being buried within the porous HSA carbon support. The effect of cell conditioning and voltage recovery on the PEFC cathode catalyst layer was shown to have minimal impact on SO 3 − group coverage despite a decrease in C dl and ECSA due to the size increase of Pt particles. At dry condition, a significant increases in SO 3 − group coverage were observed for all MEAs due to higher adsorptivity of ionomer in dry conditions.

25 ENERGY STORAGE↗

Relative-Humidity Dependence of Electrochemically Active Surface Area in Porous Carbon Catalyst Layers

Polymer-electrolyte fuel cells (PEFCs) utilize porous catalyst layers (CLs) formed of carbon supports on which Pt particles are deposited and ionomer films are distributed. Carbon supports themselves have varying degrees of porosity, where high-surface-area carbon (HSC) supports possess nanometer-sized interior pores that are suitable for Pt nanoparticle deposition but prevent deleterious ionomer penetration. However, this requires protons to transport through water pathways inside the pores. To understand the generation of such pathways, we examine the various mechanisms of water uptake by PEFC CLs, and the subsequent impact of water uptake on Pt utilization through developing a multiphysics model of the water wetting phenomena as a function of relative humidity. The model details water uptake via ionomer absorption, capillary condensation in the hydrophilic pores, and surface adsorption using molecular potential that account for various water and surface dipole interactions. The results quantify how mesoporous carbons with highly hydrophilic pores increase Pt utilization through the development of wetted layers, which at the same time enable optimized gas-transport pathways. It also demonstrates the impact of pore-size distribution (PSD) and physical and chemical parameters on the water uptake phenomena, allowing for future CL particle and structure optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Corrosion in Polymer Electrolyte Fuel Cells: A Complex Interplay between Morphological Changes and Electrochemical Performance

Due to the high gravimetric energy density of hydrogen, the focus of implementation of polymer electrolyte fuel cells (PEFCs) has shifted from light duty passenger vehicles to heavy duty vehicles such as buses, trucks, locomotives and marine vessels. A mechanistic understanding of degradation is therefore necessary to improve durability and efficiency. During start-up and shut-down (SUSD) of PEFC systems, the catalyst (Pt nanoparticles embedded on carbon support) undergoes local potentials ~ 1 - 1.5 V caused by a combination of fuel (H 2 ) starvation, mixed fuel region and cell reversal. This leads to a series of degradation phenomenon including reduction in cathode catalyst layer (cCL) thickness and porosity, loss in electrochemical surface area (ECSA), ionomer degradation and loss in electrical contact, therefore resulting in severe performance loss. The convoluted relationship between these individual degradation mechanisms, their chronology and their effects on electrochemical performance are yet unresolved. Here, the complex interplay between morphological changes due to carbon corrosion and its effects on the electrochemical performance were analyzed using a combination of detailed electrochemical characterization, spectroscopy, and electron microscopy techniques.

25 ENERGY STORAGE↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗