Search NASASearch

SEARCH · Search NASA

Results for “PHIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities

Customized open source renewable energy models validated through PHIL lab experiments

Energy models for power systems require ongoing updates to reflect advancements in equipment technology and the increasing complexity of power electronic devices. This study utilizes a Power Hardware-in-the-Loop (PHIL) experimental setup to validate custom photovoltaic (PV) inverter models, aiming to enhance and expedite the development of advanced renewable energy models. The research compares the performance of a physical inverter with generic Renewable Energy Source (RES) models recommended by the Western Electricity Coordinating Council (WECC). As inverter-based renewable energy sources become more prevalent in modern electrical grids, it is crucial that dynamic models accurately represent their real-world behavior. Accurate models improve our understanding of these energy resources and their interactions with the grid. The proposed model enhancements are designed to better reflect real inverter performance, based on insights from PHIL experiments. These models are developed using the open source Modelica language and the OpenIPSL Modelica Library, allowing integration across various simulation tools without re-implementation. The paper concludes with a thorough assessment, comparing the enhanced models with PHIL experiments on a real PV inverter in a controlled laboratory setting. As a result, the study provides the enhanced WECC RES models and validation data as open source resources, facilitating further research and development.

Modelica

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Machine Governor

This paper introduces the development of a high-fidelity gas turbine governor model using a programmable logic controller for power-hardware-in-the-loop (PHIL) validation. The governor model is integrated with the National Renewable Energy Laboratory's (NREL) PHIL test bed, featuring a 2-MVA synchronous machine and a 2.5-MW variable-speed drive, to emulate NG-driven HRSGs and CTs under various operational scenarios. The primary objective of this research is to study the grid-connected and islanding operations of conventional generation sources, with representative startup sequences including turbine purge, ignition, speed ramp-up, synchronization, and breaker closure. Preliminary results of the generator governor model on NREL PHIL platform, particularly using the 2.5-MW dynamometer system, offered significant insights into the modeling techniques, hardware integration, scaling, and real-world simulation dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION

Use of Power Hardware-in-the-Loop and Controller Hardware-in-the-Loop to De-Risk the Use Of Grid-Forming Fuel Cell Inverters in Microgrids

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such interfaces are particularly challenging when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This presentation shows the use of PHIL interfaces for such microgrids and the preliminary experimental results.

24 POWER TRANSMISSION AND DISTRIBUTION

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION

Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects (Final Technical Report)

This is the final technical report for DOE Award DE-SC0005132 entitled “Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects.” This award originated on August 15, 2010 with Principle Investigator Prof. Phil Batson of Rutgers, The State University of New Jersey. Prof. Batson transitioned to Professor Emeritus status on January 31, 2023. At that time PI status was transferred to Prof. Robert Bartynski of the Department of Physics and Astronomy at Rutgers, The State University of New Jersey, and Director of the Rutgers Laboratory for Surface Modification. The central theme of the research performed under this award is develop and refine a NION aberration-corrected Scanning Transmission Electron Microscope to attain atomic spatial resolution and sub 10meV energy resolution in electron energy loss spectroscopy (EELS) performed on the transmitted electron beam. These capabilities allow examination of the excitation properties (primarily plasmonic and vibrational [ie., phonons] of nanoscale objects when excited with a highly-localized (~ Angstrom-scale) high energy (~ 60 keV) electron beam. Direct excitations (i.e., the response to electrons impinging directly on the sample) as well as excitations in response to the dynamic electric (and magnetic!) fields of an aloof electron beam (i.e., a beam that is close to but displaced from the target) have been studied. Our experimental work has benefited greatly from close collaborations with theoretical colleagues, but at Rutgers and from around the world, providing a much more complete understanding of the observed phenomena and suggesting avenues for further study and practical applications. This report summarizes the technical and scientific achievements accomplished during the entire award period. More extensive details are available in the Progress Reports that have already been filed with the Department of Energy. The report is divided into six sections. The first four sections focus on exploring, developing and understanding several unique capabilities and phenomena discovered and accessible owing to the high spatial- and energy-resolution we have been able to achieve. The latter two sections focus on applications of the STEM’s novel capabilities to study atomic- and nanometer-scale properties of solids, as well as broader applications to advanced and bio-materials.

47 OTHER INSTRUMENTATION

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN

Electronic Melting of Silicon in Nanostructures using X-ray Forbidden Bragg Reflections

Abstract We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a “device layer” silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation. A second sample was reactive-ion-etched down to 52 nm thickness. In the silicon lattice, the covalent bonds are seen exclusively at the 222 reflection. Upon laser excitation, these electrons are expected to be excited to the valence band on femtosecond electronic time scales. The Si(222) reflection is therefore expected to be extinguished on this fast time scale, while the electron–phonon coupled acoustic response is determined by the lattice dynamics. The latter is determined by the speed of sound over the device thickness, which is in the mid-picosecond range.

77 NANOSCIENCE AND NANOTECHNOLOGY

Measurement and analysis of the Doppler broadened energy spectra of gamma radiation originating from the annihilation of positrons incident on clean and adsorbate-covered surfaces

We present measurements and theoretical modeling demonstrating the capability of coincidence Doppler broadened (CDB) annihilation gamma spectroscopy to provide element-specific information from the topmost atomic layer of surfaces. Our measurements show that the energy spectra of Doppler-shifted annihilation gamma photons emitted following the annihilation of positrons from the topmost atomic layers of clean and adsorbate covered surfaces of gold (Au), silver (Ag) and copper (Cu) differ significantly. The shape of the Doppler-broadened gamma spectrum, as analyzed using ratio curves, indicates that the elemental composition of the surface can still be identified despite contributions from positronium annihilation and a significant reduction in core electron annihilation. We estimate the chemical composition of the various probed surfaces by modeling the ratios of the measured Doppler spectra with respect to the Doppler spectra from a clean Cu surface using a linear combination of calculated ratio curves. The fitting of the experimental ratio curves was used to obtain an estimate of the elemental composition of Cu surfaces with sulfur segregation, oxygen adsorption, a thin film of Selenium (Se), and a single layer of graphene (SLG). A similar analysis was performed on the Ag surface with environmental adsorbates, the same surface after argon ion sputtering, as well as a sputter cleaned Au surface. The surface compositions obtained from the analysis of the CDB data were compared to the compositions obtained using positron annihilation induced Auger electron spectroscopy (PAES). Our results show that CDB can detect, identify, and quantify, sub-monolayer adsorbates and a single atomic layer deposited on metal substrates.

Lotfimarangloo, Sima [Univ. of Texas, Arlington, T

The temporal onset of associations of cortical proteins with cognitive resilience vary during late life

Background: Cortical proteins associated with cognitive resilience have been identified but their temporal onset in older adults is unknown. We present a multistage approach to first identify cortical proteins associated with cognitive resilience and then examine their associated temporal onset. Methods: We used data from a subset of 1088 decedents from two cohort-studies who had selected reaction monitoring proteomics from the dorsolateral prefrontal cortex, and at least 3 cognitive assessments. Cognition was assessed using a composite derived from 19 tests. We first used linear mixed-effects models to identify cortical proteins associated with cognitive resilience. We then used functional mixed-effects models to examine non-linear associations between proteins and cognitive resilience to identify their temporal onset. Results: Mean age at death was 90 years (SD = 6.4); 69 % were female. On average, cognition started to decline at around 15 years before death, with accelerated decline in the last 7 years. We identified 40 proteins associated with cognitive resilience, of which 17 proteins also showed non-linear associations. Non-linear associations indicated that higher levels of 10 proteins were associated with slower cognitive decline between 23 and 4 years before death. In contrast, higher levels of 7 proteins were associated with faster decline only within the last 7 years before death. Conclusions: Cognitive resilience proteins are differentially related to late-life cognitive aging; the onset of proteins that maintain cognition may begin many years before the onset of proteins that hasten cognitive decline. The temporal onset of cognitive resilience proteins may be crucial for timing efficacious interventions.

Zammit, Andrea

AutonomieAI: An efficient and deployable vehicle energy consumption estimation toolkit

Here, this paper presents AutonomieAI, a novel toolkit designed for efficient energy estimation of vehicles across diverse trip scenarios, routes, and drive cycles, applicable to a broad range of vehicle powertrain technologies. It leverages state-of-the-art Machine Learning techniques to deliver real-time energy prediction of vehicles, enabling co-simulation with transportation level system tools and opening doors for large-scale optimization at city, network or national level. Benchmark results show that AutonomieAI achieves high accuracy, with an average percentage error below 2% for most powertrain types, and computational efficiency capable of processing over 10,000 trips per second. Applications of AutonomieAI have potential to offer the flexibility to assist in solving eco-routing problems, optimize for vehicle and powertrain selection, study charging decision behavior, and optimize for charging station placement. AutonomieAI is the result of large neural network based model architectures, trained on very large and unique high fidelity vehicle simulation data. It is lightweight, deployable, efficient and has accuracy comparable to specialized and complex physics based simulation softwares.

Autonomie

Turbulence and transport in mirror geometries in the Large Plasma Device

Thanks to advances in plasma science and enabling technology, mirror machines are being reconsidered for fusion power plants and as possible fusion volumetric neutron sources. However, cross-field transport and turbulence in mirrors remains relatively understudied compared with toroidal devices. Turbulence and transport in mirror configurations were studied utilizing the flexible magnetic geometry of the Large Plasma Device (LAPD). Multiple mirror ratios from $M=1$ to $M=2.68$ and three mirror-cell lengths from $L=3.51$ to $L=10.86$ m were examined. Langmuir and magnetic probes were used to measure profiles of density, temperature, potential and magnetic field. The electric field-fluctuation-driven ${\tilde {\boldsymbol{E}}} \times {\boldsymbol{B}}$ particle flux, where $\boldsymbol{B}$ is the background field, was calculated from these quantities. Two probe correlation techniques were used to infer wavenumbers and two-dimensional structure. Cross-field particle flux and density fluctuation power decreased with increased mirror ratio. Core density and temperatures remain similar with mirror ratio, but radial line-integrated density increased. The physical expansion of the plasma in the mirror cell by using a higher field in the source region may have led to reduced density fluctuation power through the increased gradient scale length. This increased scale length reduced the growth rate and saturation level of rotational interchange and drift-like instabilities. Despite the introduction of magnetic curvature, no evidence of mirror-driven instabilities – interchange, velocity space or otherwise – were observed. For curvature-induced interchange, many possible stabilization mechanisms were present, suppressing the visibility of the instability.

Travis, Phil (ORCID:0000000343170432)