Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physics, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Executive summary of error sources in dynamic surface temperature measurements

Obtaining bulk T requires measuring apparent sample interface T surface , knowledge of any window conditions T window , and knowledge of thermal transport from the sample to the window. To obtain bulk T with uncertainties below 5% requires relatively small uncertainties in each of these areas, and large uncertainties in one area require smaller uncertainties in others to maintain the error budget. For example, if T window is known to 10%, a 5% total uncertainty can be obtained if T surface is known to 1% and combined transport uncertainties are known to 20%. If T surface can only be measured to 2%, combined transport uncertainties must be 17% to reach the same overall uncertainty. As the form of transport is unknown at high pressure, and window temperatures are difficult to measure by their very nature, reducing surface T uncertainties is the practical first step. Here we will discuss various error sources in the measurement of apparent T surface , and which ones must be correctly obtained prior to the experiment.

36 MATERIALS SCIENCE↗

Raman Spectroscopy to Detect and Measure NOW Pheromones ("Orchard in a box")

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Whether an aerosol puffer is used for mating disruption or lure for monitoring population development, we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. In response to these unknowns, Raman spectroscopy may offer a way to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has demonstrated the capability to detect volatiles at extremely low concentrations. We proposed to evaluate the use of Raman for the detection of synthetic and natural NOW pheromones and, were that to be successful, use this tool in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Raman Spectroscopy to Detect and Measure NOW Pheromones. Annual Report [2021]

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes and how those evolve from emission points, especially across large blocks and at plot borders. We proposed to evaluate the use of enhanced Raman spectroscopy for the detection of synthetic and natural NOW pheromones and, were that to be successful, use it in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction

This study introduces a novel iterative Bragg peak removal with automatic intensity correction (IBR-AIC) methodology for X-ray absorption spectroscopy (XAS), specifically addressing the challenge of Bragg peak interference in the analysis of crystalline materials. The approach integrates experimental adjustments and sophisticated post-processing, including an iterative algorithm for robust calculation of the scaling factor of the absorption coefficients and efficient elimination of the Bragg peaks, a common obstacle in accurately interpreting XAS data, particularly in crystalline samples. The method was thoroughly evaluated on dilute catalysts and thin films, with fluorescence mode and large-angle rotation. The results underscore the technique's effectiveness, adaptability and substantial potential in improving the precision of XAS data analysis. While demonstrating significant promise, the method does have limitations related to signal-to-noise ratio sensitivity and the necessity for meticulous angle selection during experimentation. Overall, IBR-AIC represents a significant advancement in XAS, offering a pragmatic solution to Bragg peak contamination challenges, thereby expanding the applications of XAS in understanding complex materials under diverse experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Density Implosions on OMEGA and the National Ignition Facility (NIF) (Final FY23 report for the subcontract B656484 (formerly B640112))

This final FY23 report for the subcontract B656484 (formerly B640112) “High-Density Implosions on Omega and the National Ignition Facility (NIF)” summarizes MIT’s support of LLNL experiments at OMEGA and the NIF with nuclear diagnostics, platforms and analysis, and of training PhD students. Overall, the tasks identified as Statement-Of-Work (SOW) items for FY23 were accomplished.

42 ENGINEERING↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Entropy-mode-driven gas optics

We propose a class of gaseous diffractive optical elements created by imprinting an entropy mode in a gas. Previous approaches to gaseous diffractive optics have relied on the simultaneous excitation of a standing acoustic wave and an entropy mode to produce one-dimensional periodic structures. However, the presence of acoustic oscillations in the gas imposes stringent constraints on some of the operational parameters of these optical elements, such as their lifetime and diffraction angle. Here, in this work, we introduce an approach that eliminates the acoustic mode, relying solely on the entropy mode. This enables control of the lifetime and temporal profile of gaseous optical elements, and also allows the creation of arbitrary structures with greater contrast, including nonperiodic patterns such as chirped gratings or lenses. This approach should allow operation over a wider parameter space, including larger diffraction angles and compatibility with laser pulse durations ranging from femtoseconds to microseconds.

Optics and optical instruments↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

Mapping the 3D position of battery cathode particles in Bragg coherent diffractive imaging

In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra-thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm-thick LiNi 0.5 Mn 1.5 O 4 battery cathode, the particles were located with a precision of 20 µm in the out-of-plane direction, and the in-plane coordinates were determined with a precision of 1 µm.

25 ENERGY STORAGE↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗