Search NASA⌕ Search

SEARCH · Search NASA

Results for “STACKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Effluent Management Facility Stack Monitor Qualification: Assessment with Surrogate Stacks

Sampling and monitoring at the Waste Treatment and Immobilization Plant (WTP) Effluent Management Facility (EMF) exhaust is required to meet the regulatory criteria that governs stacks that may exceed the 0.1-millirem per year threshold limit given in Title 40 of the Code of Federal Regulations, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standard for Emissions of Radionuclides other than Radon from Department of Energy Facilities. As a result, the flow conditions and probe location must be within certain bounds as prescribed by the American National Standards Institute/Health Physics Society (ANSI/HPS) standard N13.1-1999. Compliance with the standard may be demonstrated by tests on the stack itself, or with a surrogate stack (i.e., a scale model or other geometrically similar stack). Pacific Northwest National Laboratory (PNNL) has performed scale model stack tests for 11 of the 20 emission points that are planned for the WTP. Additionally, PNNL has full scale stack results from Idaho National Laboratory and PNNL facility stacks to use as references. One or more WTP scale model stack results were expected to be appropriate as a surrogate stack to the EMF. This report describes the EMF stack monitoring location as well as an assessment of existing surrogate stacks used to qualify the EMF stack sampling location.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stacking-engineered ferroelectricity in bilayer boron nitride

Stacking a ferroelectric Properties of layered van der Waals structures can depend sensitively on the stacking arrangement of constituent layers. This phenomenon has been exploited to engineer superconducting, correlated insulator, and magnetic states. Two groups now show that ferroelectricity can also be engineered through stacking: Parallel-stacked bilayers of hexagonal boron nitride exhibit ferroelectric switching even though the bulk material is not ferroelectric (see the Perspective by Tsymbal). To explore these phenomena, Yasuda et al. used transport measurements, whereas Vizner Stern et al. focused on atomic force microscopy. Science , abd3230 and abe8177, this issue p. 1458 and p. 1462 ; see also abi7296, p. 1389

Science & Technology - Other Topics↗

Tolerating memory stack failures in multi-stack systems

Memory management circuitry and processes operate to improve reliability of a group of memory stacks, providing that if a memory stack or a portion thereof fails during the product's lifetime, the system may still recover with no errors or data loss. A front-end controller receives a block of data requested to be written to memory, divides the block into sub-blocks, and creates a new redundant reliability sub-block. The sub-blocks are then written to different memory stacks. When reading data from the memory stacks, the front-end controller detects errors indicating a failure within one of the memory stacks, and recovers corrected data using the reliability sub-block. The front-end controller may monitor errors for signs of a stack failure and disable the failed stack.

Mappouras, Georgios↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

Check the Storage Stack: Comparing Behind-the-Meter Energy Storage State Policy Stacks in the United States

A variety of studies and disparate datasets track state energy storage polices, but these datasets do not cover all BTM-related storage policy. Moreover, these databases do not align these policies with the policy stacking framework. Thus, it is unclear what BTM storage policies are adopted across the country, what should comprise a complete storage policy framework or stack, and how states policies compare against that stack. This report addresses this gap in the literature by developing a state policy stack for BTM battery storage that we compare across all fifty states. This first-of-its-kind BTM storage policy stack includes 11 parent policy categories, and 31 associated policies divided across the market preparation, creation, and expansion policy components.

25 ENERGY STORAGE↗

FERMI LAT STACKING ANALYSIS OF SWIFT LOCALIZED GRBs

We perform a comprehensive stacking analysis of data collected by the Fermi Large Area Telescope (LAT) of γ -ray bursts (GRBs) localized by the Swift spacecraft, which were not detected by the LAT but which fell within the instrument’s field of view at the time of trigger. We examine a total of 79 GRBs by comparing the observed counts over a range of time intervals to that expected from designated background orbits, as well as by using a joint likelihood technique to model the expected distribution of stacked counts. We find strong evidence for subthreshold emission at MeV to GeV energies using both techniques. This observed excess is detected during intervals that include and exceed the durations typically characterizing the prompt emission observed at keV energies and lasts at least 2700 s after the co-aligned burst trigger. By utilizing a novel cumulative likelihood analysis, we find that although a burst’s prompt γ -ray and afterglow X-ray flux both correlate with the strength of the subthreshold emission, the X-ray afterglow flux measured by Swift ’ s X-ray Telescope at 11 hr post trigger correlates far more significantly. Overall, the extended nature of the subthreshold emission and its connection to the burst’s afterglow brightness lend further support to the external forward shock origin of the late-time emission detected by the LAT. These results suggest that the extended high-energy emission observed by the LAT may be a relatively common feature but remains undetected in a majority of bursts owing to instrumental threshold effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Stack Flow Rate Changes and the ANSI/N13.1-1999 Qualification Criteria: Application to the Hanford Canister Storage Building Stack

The Canister Storage Building (CSB), located in the 200-East Area of the Hanford Site, is a 42,000 square foot facility used to store spent nuclear fuel from past activities at the Hanford Site. Because the facility has the potential to emit radionuclides into the environment, its ventilation exhaust stack has been equipped with an air monitoring system. Subpart H of the National Emissions Standards for Hazardous Air Pollutants requires that a sampling probe be located in the exhaust stack in accordance with criteria established by the American National Standards Institute/Health Physics Society Standard N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D Columnar Phase of Stacked Short DNA Organized by Coherent Membrane Undulations

We report on the discovery of a new organized lipid-nucleic acid phase upon intercalation of blunt duplexes of short DNA (sDNA) within cationic multilayer fluid membranes. End-to-end interactions between sDNA leads to columnar stacks. At high membrane charge density, with the inter-sDNA column spacing (d sDNA ) comparable but larger than the diameter of sDNA, a 2D columnar phase (i.e., a 2D smectic) is found similar to the phase in cationic liposome-DNA complexes with long lambda-phage DNA. Remarkably, with increasing d sDNA as the membrane charge density is lowered, a transition is observed to a 3D columnar phase of stacked sDNA. This occurs even though direct DNA–DNA electrostatic interactions across layers are screened by diffusing cationic lipids near the phosphate groups of sDNA. Softening of the membrane bending rigidity (κ), which further promotes membrane undulations, significantly enhances the 3D columnar phase. These observations are consistent with a model by Schiessel and Aranda-Espinoza where local membrane undulations, due to electrostatically induced membrane wrapping around sDNA columns, phase lock from layer-to-layer, thereby precipitating coherent “crystal-like” undulations coupled to sDNA columns with long-range position and orientation order. The finding that this new phase is stable at large d sDNA and enhanced with decreasing κ is further supportive of the model where the elastic cost of membrane deformation per unit area around sDNA columns (∝ κh 2 /d sDNA 4 , h 2 = sum of square of amplitudes of the inner and outer monolayer undulations) is strongly reduced relative to the favorable electrostatic attractions of partially wrapped membrane around sDNA columns. Here, the findings have broad implications in the design of membrane-mediated assembly of functional nanoparticles in 3D.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of lateral size distribution of type-II ZnTe/ZnSe stacked submonolayer quantum dots via spectral analysis of optical signature of the Aharanov-Bohm excitons

For submonolayer quantum dot (QD) based photonic devices, size and density of QDs are critical parameters, the probing of which requires indirect methods. We report the determination of lateral size distribution of type-II ZnTe/ZnSe stacked submonolayer QDs, based on spectral analysis of the optical signature of Aharanov-Bohm (AB) excitons, complemented by photoluminescence studies, secondary-ion mass spectroscopy, and numerical calculations. Numerical calculations are employed to determine the AB transition magnetic field as a function of the type-II QD radius. The study of four samples grown with different tellurium fluxes shows that the lateral size of QDs increases by just 50%, even though tellurium concentration increases 25-fold. Detailed spectral analysis of the emission of the AB exciton shows that the QD radii take on only certain values due to vertical correlation and the stacked nature of the QDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling and Qualification of a Modified Emission Unit for Radioactive Air Emissions Stack Sampling Compliance

A planned laboratory space and exhaust system modification to the Pacific Northwest National Laboratory Material Science and Technology Building indicated a new evaluation of the mixing at the air sampling system location would be required for compliance to ANSI/HPS N13.1-2011. The modified exhaust system would add a third fan thereby increasing the overall exhaust rate out the stack thus voiding the previous mixing study. Prior to modifying the radioactive air emissions exhaust system, a three-dimensional computational fluid dynamics computer model was used to evaluate the mixing at the sampling system location. Modeling of the new original three-fan system indicated that not all mixing criteria could be met. A second modeling effort was conducted with the addition of an air blender downstream of the confluence of the three fans which then showed satisfactory mixing results. The final installation included an air blender, and the exhaust system underwent full-scale tests to verify velocity, cyclonic flow, gas, and particulate uniformity. The modeling results and those of the full-scale tests show agreement between each of the evaluated criteria. The use of a computational fluid dynamics code was an effective aid in the design process and allowed the sampling system to remain in its original location while still meeting the requirements for sampling at a well-mixed location.

atmospheric emissions, air monitoring, environment↗

Discrimination of xylene isomers in a stacked coordination polymer

The separation and purification of xylene isomers is an industrially important but challenging process. Developing highly efficient adsorbents is crucial for the implementation of simulated moving bed technology for industrial separation of these isomers. Herein, we report a stacked one-dimensional coordination polymer {[Mn(dhbq)(H 2 O) 2 ], H 2 dhbq = 2,5-dihydroxy-1,4-benzoquinone} that exhibits an ideal molecular recognition and sieving of xylene isomers. Its distinct temperature-adsorbate–dependent adsorption behavior enables full separation of p -, m -, and o -xylene isomers in both vapor and liquid phases. The delicate stimuli-responsive swelling of the structure imparts this porous material with exceptionally high flexibility and stability, well-balanced adsorption capacity, high selectivity, and fast kinetics at conditions mimicking industrial settings. This study may offer an alternative approach for energy-efficient and adsorption-based industrial xylene separation and purification processes.

Science & Technology - Other Topics↗