Search NASASearch

SEARCH · Search NASA

Results for “Scanning Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy

Scanning electron microscopy of lunar regolith from the Sea of Fertility

Scanning electron microscopy was used in studying the morphology and cathodoluminescence of lunar regolith particles. Surface and structure of two groups of particles are differentiated: (1) Crystalline with well defined facets and spalling surfaces, which are grains of minerals and rock fragments: and (2) amorphous, fused, and partially or entirely glazed particles. Local melting of particles and the round openings on their surfaces are attributed to secondary influence on the regolith of factors of lunar weathering and above all micrometeoric impacts.

Antoshin, M. K.

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.

Endolithic algae and micrite envelope formation in Bahamian oolites as revealed by scanning electron microscopy.

Examination of Holocene Bahamian ooelites by scanning electron and light microscopy has revealed the morphology and orientation of aragonite crystals in the lamellar ooelitic envelope, and their modification by the boring activities of endolithic algae. The voids produced by these algae are found in progressive stages of being lined and filled with precipitated microcrystalline aragonite, which is similar to the process of micrite envelope formation in molluscan and other skeletal carbonate grains.

Margolis, S.

Chemistry and surface morphology of soil particles from Luna 20 LRL sample 22003.

Optical and scanning electron microscopy, scanning electron microprobes and energy dispersion techniques were applied in an analysis of six siliceous glass spheres, five siliceous glass-bonded agglutinates and one breccia fragment from Luna 20 sample 22003. It is theorized that local meteor impact processes might have been responsible for the formation of most of the glass spheres and that the impacts of relatively high velocity particles might have been responsible for the craters observed on the surfaces of the spheres. The concentrations of iron spherules on the surfaces of the glass spheres were generally lower than in similar Apollo 11 and 12 glass spheres.

Carter, J. L.

Fretting wear in titanium, Monel-400, and cobalt 25-percent-molybdenum using scanning electron microscopy

Damage scar volume measurements taken from like metal fretting pairs combined with scanning electron microscopy observations showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt - 25-percent molybdenum. Initially, adhesion and plastic deformation of the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism which produced spall-like pits in the damage scar. Finally, a combination of oxidation and abrasion by debris particles became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

Bill, R. C.

Study of fretting wear in titanium, Monel-400, and cobalt-25 percent molybdenum using scanning electron microscopy.

Damage scar volume measurements taken from like metal fretting pairs, combined with scanning electron microscopy observations, showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt-25% molybdenum. Initially, adhesion and plastic deformation on the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism, producing spall-like pits in the damage scar. Finally, an oxidation-related mechanism became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

Bill, R. C.

New Insights on Subsurface Imaging of Carbon Nanotubes in Polymer Composites via Scanning Electron Microscopy

Despite many studies of subsurface imaging of carbon nanotube (CNT)-polymer composites via scanning electron microscopy (SEM), significant controversy exists concerning the imaging depth and contrast mechanisms. We studied CNT-polyimide composites and, by threedimensional reconstructions of captured stereo-pair images, determined that the maximum SEM imaging depth was typically hundreds of nanometers. The contrast mechanisms were investigated over a broad range of beam accelerating voltages from 0.3 to 30 kV, and ascribed to modulation by embedded CNTs of the effective secondary electron (SE) emission yield at the polymer surface. This modulation of the SE yield is due to non-uniform surface potential distribution resulting from current flows due to leakage and electron beam induced current. The importance of an external electric field on SEM subsurface imaging was also demonstrated. The insights gained from this study can be generally applied to SEM nondestructive subsurface imaging of conducting nanostructures embedded in dielectric matrices such as graphene-polymer composites, silicon-based single electron transistors, high resolution SEM overlay metrology or e-beam lithography, and have significant implications in nanotechnology.

Zhao, Minhua

Scanning electron microscopy study of adhesion in sea urchin blastulae

The dissociation supernatant (DS) isolated by disaggregating Strongylocentrotus purpuratus blastulae in calcium- and magnesium-free seawater specifically promotes reaggregation of S. purpuratus blastula cells. The purpose of this study was to use scanning electron microscopy to examine the gross morphology of aggregates formed in the presence of DS to see if it resembles adhesion in partially dissociated blastulae. A new reaggregation procedure developed here, using large volumes of cell suspension and a large diameter of rotation, was utilized to obtain sufficient quantities of aggregates for scanning electron microscopy. The results indicate that aggregates formed in the presence of DS resemble partially dissociated intact embryos in terms of the direct cell-cell adhesion observed. DS did not cause aggregation to form as a result of the entrapment of cells in masses of extracellular material. These studies provide the groundwork for further studies using transmission electron microscopy to more precisely define the adhesive contacts made by cells in the presence of the putative adhesion molecules present in DS.

Crowther, Susan D.

A scanning electron microscopy study of the macro-crystalline structure of 2-(2,4-dinitrobenzyl) pyridine

The compound, 2-(2,4-dinitrobenzyl) pyridine, was synthesized in the laboratory; an introductory level electron microscopy study of the macro-crystalline structure was conducted using the scanning electron microscope (SEM). The structure of these crystals was compared with the macrostructure of the crystal of 2-(2,4-dinitrobenzyl) pyridinium bromide, the hydrobromic salt of the compound which was also synthesized in the laboratory. A scanning electron microscopy crystal study was combined with a study of the principle of the electron microscope.

Ware, Jacqueline