Search NASASearch

SEARCH · Search NASA

Results for “Single-Event Effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electric‐Field‐Driven Reversal of Ferromagnetism in (110)‐Oriented, Single Phase, Multiferroic Co‐Substituted BiFeO 3 Thin Films

Abstract While multiferroic materials are attractive systems for the promise of ultra‐low‐power‐consumption computational technologies, electric‐field‐induced magnetization reversal is a key challenge for realizing devices at scale. Though significant research efforts have been working toward the realization of a material which couples ferroelectricity and ferromagnetism, there are few, even composite, systems which are practical for device scale applications at room temperature. Co‐substituted multiferroic BiFe 0.9 Co 0.1 O 3 is a promising candidate system, due to coupled ferroelectricity and weak ferromagnetism at room temperature. Here, it is theoretically indicated that the ferroic orders in this material are statically coupled, where an in‐plane 109° ferroelectric switching event can result in the reversal of this out‐of‐plane component of magnetization, and the electric field‐induced magnetization reversal is experimentally observed. Such an in‐plane poling configuration is particularly desirable for device applications.

Chemistry

The 10 September 2025 M w 4.1 Earthquake in Northeastern Utah, United States: An Archetypal Continental Mantle Event

The 10 September 2025 M w 4.1 earthquake in northeastern Utah, United States, had a focal depth 68 km beneath sea level, which is ∼20–25 km greater than estimates of local crustal thickness, making it a rare example of a continental mantle earthquake (CME). The focal depth is well resolved from arrival-time inversion (nearest station ∼13 km away) and moment tensor inversion of regional waveforms. Similar to other CMEs in the Intermountain West, there were no obvious aftershocks or foreshocks, and the waveforms were enriched in high-frequency energy. Spectral modeling gives a stress drop of ∼80 MPa and a radiation efficiency of ∼0.08, albeit with large uncertainties. The high stress drop and low radiation efficiency are consistent with a dissipative source process such as thermal runaway. Also similar to previous Intermountain West CMEs, the event occurred along the boundary of the Archean Wyoming craton, where pressure–temperature conditions favor ductile deformation. We hypothesize that edge-driven or regional-scale mantle convection produces increased strain rates near the craton boundary that make either conventional brittle failure or thermal runaway feasible at relatively high pressure–temperature conditions. High conductivity inferred around the edge of the craton may suggest that fluids also contribute to CME occurrence.

Koper, Keith D. [Univ. of Utah, Salt Lake City, UT

Prioritizing Uncertainties in Hydrogen Contribution to Risk in Post-Crash Outcomes for Rail

This report presents analysis from Sandia National Laboratories predicting contributions to risk associated with the use of hydrogen technology for rail. Event sequence diagrams are used to describe possible accident scenarios and progressions. Initiating event frequencies and branch event probabilities for each scenario are quantified with uncertainty using distributions fit to Federal Railroad Administration and U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration data on applicable accidents from 2000 to 2020. Uncertainty is propagated through the event sequence diagram to estimate the frequency and conditional probability of accident end states. The analysis identifies four scenarios with significant contributions to risk from hydrogen that are predicted to occur relatively frequently, which may inform priorities for reducing uncertainty. These scenarios are 1) overpressure events resulting from collisions with hydrogen release due to mechanical damage and delayed ignition, 2) jet fire events resulting from collisions with hydrogen release due to mechanical damage and immediate ignition, 3) jet fires resulting from fire or explosion initiating events involving the hydrogen tank and correct operation of the thermally-activated pressure relief device (TPRD) subsequent to the thermal insult, and 4) pressure burst resulting from fire or explosion initiating events involving the hydrogen tank and failure of the TPRD. Delayed and immediate hydrogen ignition probabilities are identified as being highly uncertain and potential candidates for reducing conservatism in the predicted frequencies for these two scenarios.

08 HYDROGEN

Single-crystal NMC622 from combustion-assisted solid-state synthesis: Tunable particle size, voltage-dependent stability, and Li-ion diffusion

Cost-effective and scalable synthesis of single-crystal lithium–metal-oxide cathodes with controlled size and morphology remains challenging for advancing high-performance lithium-ion batteries. Here, we demonstrate a solution combustion–assisted solid-state method for producing single-crystal NMC622 with tunable particle size at various lithium stoichiometries. Structural and electronic characteristics were probed using synchrotron-XANES, EXAFS, XRD and XPS, confirming well-defined coordination environments and phase purity up to Li ≈ 1.3. The electrochemical behavior of LixNMC (x = 1.0 and 1.3) single crystals was evaluated across 2.8–4.3 V and 2.8–4.7 V windows to elucidate the effects of lithium content and operating voltage. At 2.8–4.3V, Li1.3NMC exhibits higher initial capacity due to its larger lithium inventory, while Li1.0NMC shows superior long-term retention driven by its larger crystal size and reduced structural distortion. Increasing the cutoff voltage to 4.7 V enhances the initial capacity of both compositions by 17–25%, but long-term capacity retention ultimately converges to values comparable to those at 4.3 V due to voltage-induced degradation, where Li+ diffusion constant remains lying ranging from 10−12 –10−11 cm2s−1. Overall, this study establishes a scalable combustion-assisted route for synthesizing tunable single-crystal NMC622 and highlights the interplay between lithium stoichiometry, particle size, and voltage window in governing cathode stability.

Roy, Subrata C [Jackson State University]

Spin-strain interactions under hydrostatic pressure in α-RuCl 3

We investigate the effects of hydrostatic pressure on 𝛼−RuCl 3 , a prototypical material for the Kitaev spin model on a honeycomb lattice with a possible spin-liquid ground state. Using ultrasound measurements at pressures up to 1.16 GPa, we reveal significant modifications of the acoustic properties and the 𝐻−𝑇 phase diagram of this material. Hydrostatic pressure suppresses the three-dimensional magnetic order and induces a dimerization transition at higher pressures. At low pressures, the sound attenuation exhibits a linear temperature dependence, while above 0.28 GPa, it becomes nearly temperature independent, suggesting a shift in the phonon scattering regime dominated by Majorana fermions. These findings provide new insights into spin-strain interactions in Kitaev magnets and deliver a detailed characterization of the 𝐻−𝑇 phase diagram of 𝛼−RuCl 3 under hydrostatic pressure.

Focused ion beam

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Do Households Adapt? Repeated Hurricane Exposure and the Purchasing of Bottled Water

Understanding how households adapt to hurricanes is increasingly important as these events become more frequent and severe. This paper examines how past hurricane exposure influences current household preparedness, focusing specifically on the stockpiling of bottled water. Leveraging scanner data on bottled water purchases for households in the Southeastern United States, we employ a difference-in-differences event study framework to analyze how repeated hurricane experiences affect consumer behavior. Our results indicate that households exposed to hurricane warnings do not increase their preparedness in the subsequent hurricane season, and those experiencing a landfall event underprepare. These results suggest limited learning from past events.

D12

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo

Nuclear Safety [Vol. 35, No. 1, January-June 1994]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: THE CHERNOBYL ACCIDENT: 1 Chernobyl Accident Management Actions, A. R Sich 25 The IAEA-ASSET Approach to Avoiding Accidents is to Recognize the Precursors to Prevent Incidents, F. Reisch; ACCIDENT ANALYSIS: 36 A Review of the Available Information on the Triggering Stage of a Steam Explosion, D. F. Fletcher; 58 Analysis and Modeling of Flow-Blockage-Induced Steam Explosion Events in the High-Flux Isotope Reactor, R. P. Taleyarkhan, V. Georgevich, C. W. Nestor, U. Gat, B. L. Lepard, D. H. Cook, J. Freels, S. J. Chang, C. Luttrell, R. C. Gwaltney, and J. Kirkpatrick; 74 An Analysis of Disassembling the Radial Reflector of a Thermionic Space Nuclear Reactor Power System, M. S. El-Genk and D. V. Paramonov; CONTROL AND INSTRUMENTATION: 86 Standards for High-Integrity Software, D. R. Wallace, D. R. Kuhn, L M. Ippolito, and L. Beltracchi; DESIGN FEATURES: 98 Adoption of New Design Features for the Next Generation Nuclear Power Reactors, L. S. Tong; 114 Review of Nuclear Piping Seismic Design Requirements, G. C. Slagis and S. E. Moore; ENVIRONMENTAL EFFECTS: 128 PC-Based Probabilistic Safety Assessment Study for a Geological Waste Repository Placed in a Bedded Salt Formation, S. A. Khan; OPERATING EXPERIENCES: 142 Managing Aging in Nuclear Power Plants: Insights from NRC’s Maintenance Team Inspection Reports, A. Fresco and M. Subudhi; 150 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 153 Selected Safety-Related Events, Compiled by G. A. Murphy; RECENT DEVELOPMENTS: 158 Reports, Standards, and Safety Guides, D. S. Queener; 168 Proposed Rule Changes as of Dec. 31, 1993; ANNOUNCEMENTS: 177 Symposium on Radioactive and Mixed Waste—Risk as a Basis for Waste Classification; 177 1995 Incineration Conference 178 Ninth Power Plant Dynamics Control and Testing Symposium; 174 The Authors

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Modeling Occupant Core Temperatures Across the Boston Building Stock to Advance Public Health

In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.

Nuclear Safety [Vol. 35, No. 1, January-June 1994]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Chernobyl Accident Management Actions, A. R Sich; GENERAL SAFETY CONSIDERATIONS: 25 The IAEA-ASSET Approach to Avoiding Accidents is to Recognize the Precursors to Prevent Incidents, F. Reisch; ACCIDENT ANALYSIS: 36 A Review of the Available Information on the Triggering Stage of a Steam Explosion, D. F. Fletcher; 58 Analysis and Modeling of Flow-Blockage-Induced Steam Explosion Events in the High-Flux Isotope Reactor, R. P. Taleyarkhan, V. Georgevich, C. W. Nestor, U. Gat, B. L. Lepard, D. H. Cook, J. Freels, S. J. Chang, C. Luttrell, R. C. Gwaltney, and J. Kirkpatrick; 74 An Analysis of Disassembling the Radial Reflector of a Thermionic Space Nuclear Reactor Power System, M. S. El-Genk and D. V. Paramonov; CONTROL AND INSTRUMENTATION: 86 Standards for High-Integrity Software, D. R. Wallace, D. R. Kuhn, L M. Ippolito, and L. Beltracchi; DESIGN FEATURES: 98 Adoption of New Design Features for the Next Generation Nuclear Power Reactors, L. S. Tong; 114 Review of Nuclear Piping Seismic Design Requirements, G. C. Slagis and S. E. Moore; ENVIRONMENTAL EFFECTS: 128 PC-Based Probabilistic Safety Assessment Study for a Geological Waste Repository Placed in a Bedded Salt Formation, S. A. Khan; OPERATING EXPERIENCES: 142 Managing Aging in Nuclear Power Plants: Insights from NRC’s Maintenance Team Inspection Reports, A. Fresco and M. Subudhi; 150 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 153 Selected Safety-Related Events, Compiled by G. A. Murphy; RECENT DEVELOPMENTS: 158 Reports, Standards, and Safety Guides, D. S. Queener; 168 Proposed Rule Changes as of Dec. 31, 1993; ANNOUNCEMENTS: 177 Symposium on Radioactive and Mixed Waste—Risk as a Basis for Waste Classification; 177 1995 Incineration Conference 178 Ninth Power Plant Dynamics Control and Testing Symposium; 174 The Authors

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)

Technology & Design Innovations to Maximize the Reduction Effect on DCFC Unit Cost Economics (Max‐REDUCE)

With the high cost and reliability issues of DCFC infrastructure the project specifically addressed the needs of innovating on the AC to DC power conversion. We proved the integration of a new power module into existing charger units, and that theoretical educational work on single stage energy conversion is commercially viable, and a reduced cost compared to existing methods. Our A sample shown 3 PH 480VAC 60hz to 350VDC 8.5kW power transfer, and our software and simulation proved efficiency greater than 97% from 20kW to > 60kW, over the DC output voltage range 200 – 1200V. The project was stopped before we could implement B sample and execute full power testing, validation and integration into a demonstration charger (budget period 3).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI