Search NASA⌕ Search

SEARCH · Search NASA

Results for “XCT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microstructural characterization of the oxidation of nuclear graphite under chronic and accident conditions via XCT and synchrotron XCT

Graphite is a candidate material to moderate fast neutrons and for structural components in the US next-generation graphite-moderated reactors. A graphite core is conceived as a large formation of interconnected bricks that primarily serves as the moderator of fast neutrons, holds instrumentation, fuel elements, control rods, and is a receptacle for molten salts for Molten Salt Reactors (MSRs) designs. During the operation of a graphite-moderated power plant, graphite components might be subjected to chronic oxidation during normal operating conditions or aggressive oxidation as a result of accidental ingress of air that reacts vigorously with the graphite core. Using synchrotron, x-ray computed tomography (XCT), this research systematically characterized microstructural changes that accompanied these two oxidation scenarios. Chronic oxidation was studied by characterizing IG-110, PCEA, and NBG-18 specimens that were gradually oxidized in air at a low temperature (520°C). The accidental ingress of air into the graphite reactor was simulated by subjecting the grades mentioned above to high-temperature oxidation at approximately 750°C. This research is the first, in situ, systematic characterization of nuclear graphite microstructural evolution that can be associated with the two possible oxidation scenarios and provide insight into related repercussions. The results show that the microstructure and pore connectivity influence the rate of oxidation and evolution of the microstructure under the two oxidation regimes. These results are crucial to understanding which grades are more resilient to each type of oxidation and documenting the damage created in the graphite.

Arregui Mena, Jose'↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

Nanopore networks in colloidal silica assemblies characterized by XCT for confined fluid flow modeling

Fluid flow through nanopore structures has exhibited different behavior than that described by Darcy's law, derived from pore networks of micrometer scale. Here, pressure assemblies of colloidal silica spheres of specified diameters from 94 to 620 nanometers were prepared as model nano-porous media. The smaller silica spheres tended to form random packing, but some substantial ordering was found in the packing of the larger silica spheres. X-ray computed tomography (XCT), with a voxel resolution of 16 nm, was used to characterize the nanopore networks. The porosity of the Nano-XCT pore network (34%) was less than the total porosity of the assemblies as determined by X-ray attenuation (52%), possibly due to the limits of voxel resolution during segmentation. Fluid flow in the nanopore networks was simulated using the single-phase Lattice Boltzmann Method, and the simulated permeability was compared with the empirical and experimental values. Based on our characterization, although a well-ordered packing of silica spheres was not achieved, it was found that the nanopore networks in the colloidal silica assemblies had pore size distributions corresponding to the particle sizes. The simulated permeability was less than the experimental measurement for water flow, but the complex packing of silica spheres and surface chemistry issues need to be considered in future research.

02 PETROLEUM↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

XCT System for Harvesting In-Current Hydrokinetic Energy from Low-Velocity Sites

The Project demonstrated the functionality of a cross cutting (XCT) type turbine in laboratory and open water testing. The fundamental design approach of locating small axial rotors near the ends of driving spars, which pull the rotors through the water at a multiple of the free-stream velocity eliminates the need (and thus the cost) for a gearbox and torque resisting structures. This configuration, however, introduces the complexity of transmitting electricity across a rotating interface. Even so, cost models indicate that depending on the anchoring and mooring system, LCOE less than $0.10/kWh should be possible in high capacity-factor sites with non-reversing currents.

13 HYDRO ENERGY↗

Developing a system for in vivo imaging of maize roots containing iodinated contrast media in soil using synchrotron XCT and XRF

We sought to develop a novel experimental system which enabled application of iodinated contrast media to in vivo plant roots intact in soil and was compatible with time-resolved synchrotron X-ray computed tomography imaging. The system was developed to overcome issues of low contrast to noise within X-ray computed tomography images of plant roots and soil environments, the latter of which can complicate image processing and result in the loss of anatomical information. To demonstrate the efficacy of the system we employ the novel use of both synchrotron X-ray computed tomography and synchrotron X-ray fluorescence mapping to capture the translocation of the contrast media through root vasculature into the leaves. With the application of contrast media we identify fluid flow in root vasculature and visualise anatomical features, which are otherwise often only observable in ex vivo microscopy, including: the xylem, metaxylem, pith, fibres in aerenchyma and leaf venation. We are also able to observe interactions between aerenchyma cross sectional area and solute transport in the root vasculature with depth. Our novel system was capable of successfully delivering sufficient contrast media into root and leaf tissues such that anatomical features could be visualised and internal fluid transport observed. We propose that our system could be used in future to study internal plant transport mechanisms and parameterise models for fluid flow in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Beam Hardening Artifact Reduction in X-Ray CT Reconstruction of 3D Printed Metal Parts Leveraging Deep Learning and CAD Models

Nondestructive evaluation (NDE) of additively manufactured (AM) parts is important for understanding the impacts of various process parameters and qualifying the built part. X-ray computed tomography (XCT) has played a critical role in rapid NDE and characterization of AM parts. However, XCT of metal AM parts can be challenging because of artifacts produced by standard reconstruction algorithms as a result of a confounding effect called “beam hardening.” Beam hardening artifacts complicate the analysis of XCT images and adversely impact the process of detecting defects, such as pores and cracks, which is key to ensuring the quality of the parts being printed. In this work, we propose a novel framework based on using available computer-aided design (CAD) models for parts to be manufactured, accurate XCT simulations, and a deep-neural network to produce high-quality XCT reconstructions from data that are affected by noise and beam hardening. Using extensive experiments with simulated data sets, we demonstrate that our method can significantly improve the reconstruction quality, thereby enabling better detection of defects compared with the state of the art. We also present promising preliminary results of applying the deep networks trained using CAD models to experimental data obtained from XCT of an AM jet-engine turbine blade.

Ziabari, Amir↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Automated Image Segmentation and Processing Pipeline Applied to X–Ray Computed Tomography Studies of Pitting Corrosion in Aluminum Wires

Understanding pitting corrosion is critical, yet its kinetics and morphology remain challenging to study from X-ray computed tomography (XCT) due to manual segmentation barriers. To address this, an automated pipeline leveraging deep learning for efficient large-scale XCT analysis is developed, revealing new corrosion insights. The pipeline enables pit segmentation, 3D reconstruction, statistical characterization, and a topological transformation for visualization. Here, the pipeline is applied to 87 648 XCT images capturing commercial purity aluminum (1100 Al) wire exposed to sodium chloride (NaCl) salt particles over a period of 122 h. The pipeline achieves complete feature extraction and statistical quantification across the entire XCT dataset, leveraging distributed computing environment for high efficiency. Global growth kinetics such as high-level stepwise sigmoidal volume loss patterns and granular individual pit developments are both captured for 36 detected pits. By combining automation, computer vision, and extensive XCT datasets, this research accelerates precise corrosion assessment to enable materials science discoveries at scale.

36 MATERIALS SCIENCE↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Parametrically designed surface topography on CAD models of additively manufactured lattice structures for improved design validation

Additively Manufactured (AM) lattice structures of the laser powder bed fusion (LPBF) process generally have different surface geometries depending on the overhang angle and location. This means that the design validation stage is often challenging, considering it is based on an ideal Computer Aided Design (CAD) model that is not truly representative, since the AM part will be different in terms of dimensional accuracy and surface finish. Previous studies have relied on the design of surface textures that are independent of the overhang angle, or techniques based on directly using X-ray Computed Tomography (XCT) data. In this paper, a new technique for designing surface texture on the CAD of lattices has been investigated and correlated with areal surface roughness parameters. After extracting areal surface parameters from the XCT data of the lattice, the method allowed for the design of this surface texture on the part CAD taking in consideration if its up skin or down skin, without using XCT data as the main input. By applying this method, it is possible to obtain a lattice CAD model with a designed surface texture and geometry that is more representative of the actual AM lattice. The mean deviation between the CAD model with the designed surface and the XCT was a third of the one between the XCT and the initial CAD. The proposed method allows for designing and replicating LPBF AM surfaces on the CAD of a lattice, taking into consideration the dimensional deviation caused by AM surfaces, especially on overhangs. Assuming that an LPBF AM process is stable and produces approximately the same AM surface, this method can be used to predict the geometry of a lattice, providing a cost-effective and efficient methodology that minimizes the time needed for design validation.

42 ENGINEERING↗

Deep Learning Based Workflow for Accelerated Industrial X-Ray Computed Tomography

X-ray computed tomography (XCT) is an important tool for high-resolution non-destructive characterization of additively-manufactured metal components. XCT reconstructions of metal components may have beam hardening artifacts such as cupping and streaking which makes reliable detection of flaws and defects challenging. Furthermore, traditional workflows based on using analytic reconstruction algorithms require a large number of projections for accurate characterization - leading to longer measurement times and hindering the adoption of XCT for in-line inspections. In this paper, we introduce a new workflow based on the use of two neural networks to obtain high-quality accelerated reconstructions from sparse-view XCT scans of single material metal parts. The first network, implemented using fully-connected layers, helps reduce the impact of BH in the projection data without the need of any calibration or knowledge of the component material. The second network, a convolutional neural network, maps a low-quality analytic 3D reconstruction to a high-quality reconstruction. Using experimental data, we demonstrate that our method robustly generalizes across several alloys, and for a range of sparsity levels without any need for retraining the networks thereby enabling accurate and fast industrial XCT inspections.

Rahman, Obaid↗