At least 19 records

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE

Experimental design of an interlaboratory study for trace metal analysis of liquid fluids

The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique.

Greenbauer-Seng, L. A.

Component Identification of Solid Biomass Fuels Using Reflected Light Microscopy: Interlaboratory Study 2

As nations transition toward sustainable energy systems, biomass has become a vital component of global energy portfolios. Derived from organic materials such as wood, agricultural residues, forestry byproducts, and organic waste, biomass is a renewable energy source with significant environmental and economic benefits. Responsible biomass energy production can improve waste management, reduce emissions of greenhouse gases, and mitigate environmental pollution. However, as the diversity of biomass-derived fuels increases, robust quality assessment methods are essential to ensure their efficiency, safety, and minimal environmental impact. Reflected light microscopy (RLM) is one such technique with the potential to complement conventional physico-chemical analyses by enabling a rapid identification of material constituents and impurities. To refine this methodology and evaluate the reproducibility of solid biomass component identification using RLM, an interlaboratory study (ILS) was conducted. The study involved the recognition of 58 components across 45 photomicrographs, with the participation of 65 scientists and students from 25 countries. The participants faced high difficulty identifying some of the marked components, and as a result, the percentage of correct answers ranged from 19.0 % to 98.3 %, with an average correct identification rate of 62.7 %. The most challenging aspects of the identification process included distinguishing between woody and non-woody (agro) biomass, accurately identifying petroleum-derived materials, and differentiating agro biomass from inorganic matter. The results suggest that while RLM is an important tool for characterizing solid biomass, further development of methodology guidelines and training are necessary to enhance its effectiveness. Future research should prioritize preparing detailed, image-rich, microscopic morphological descriptions of biomass fuel components, which could improve the accuracy and reliability of using RLM in biomass fuel characterization.

09 BIOMASS FUELS

The Two-Cavity Method for Characterizing Acoustical Materials—an Interlaboratory Study

This study focuses on understanding the sound absorption characteristics of porous acoustic materials, which are determined by two key parameters independent of material thickness: characteristic impedance and propagation constant. These parameters can be characterized by testing a porous sample concept in a normal incidence impedance tube using either the two-thickness or the two-cavity method. In the two-thickness method, two samples of varying thicknesses are required. In contrast, the two-cavity method requires testing one sample at two different air cavity depths behind the porous material. This method is particularly advantageous for materials that are costly or challenging to fabricate. This interlaboratory study evaluates the variability of characteristic properties determined using the two-cavity method. Porous acoustic materials were additively manufactured and tested in the Liner Technology Facility(LTF)at NASA Langley Research Center and the Mechanics, Acoustics and Dynamics Lab (MADLab) at Michigan Technological University. The characteristic properties derived from various cavity depth combinations were used to predict the surface impedance of the sample with a rigid backing. The prediction was then compared the measured impedance spectrum. It was also found that the combinations of cavity depths can significantly influence the accuracy of the deduced properties.

acoustic liners

Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results

The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.

Allen, P. A.

Development of a Reference Dose for Perchlorate: Current Issues and Status

The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and incomplete data from the other two, US EPA/NCEA issued a document in December 1998 stating that the critical effects were hormone and histology data from the neurodevelopmental/behavioral toxicity study that had been performed in rats; an RfD was proposed based upon the observation of thyroid-follicular-cell hypertrophy in the 5-day-old pups (PND) of dams given perchlorate in drinking water at 0.1 mg/kg-day (the lowest dose tested) in this study. US EPA/NCEA also focused attention on a nonsignificant increase in motor activity observed in 14-day-old male pups in the same study at the same dose. In February 1999, a public workshop was convened at which an external peer-review panel determined that there was still insufficient data to support the development of a RfD. Additional studies were recommended. Since that time a clinical study revealed significant depression of thyroidal uptake of iodide in volunteers receiving potassium perchlorate at 10 mg/day for 14 days. Follow-up studies currently underway include a pathology working-group review of histology slides from the all of the previous studies, a motor activity study similar to the first behavioral study, an additional immunotoxicity study, male and female rat kinetic studies, a hormone interlaboratory study, and an effects study for thyroid and brain in developing rats. These studies are expected to be complete by mid-2000. A clinical study is planned to determine inhibition of iodide uptake and kinetic parameters in humans following 14-day perchlorate ingestion. The kinetics studies will provide data for developing physiologically based pharmacokinetic (PBPK) models for rats and humans needed to establish the RfD.

Pleus, R. C.

Accuracy of trace element determinations in alternate fuels

A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

Greenbauer-Seng, L. A.

The development and application of the stirred‐reactor coupon analysis (SRCA) test method

A new technique, termed the stirred‐reactor coupon analysis (SRCA) method, has been developed to measure the rate of glass dissolution in forward‐rate conditions. Monolithic glass coupons are partially masked with an inert material before placement in a large volume of well‐mixed solution with known chemistry and temperature for a predetermined duration. After the test, the mask is removed, and the difference in step height between the protected area and the exposed corroded portions of the sample coupon is measured to determine the extent of glass dissolution. The step height is converted to a rate measurement using the test duration and glass density. Test parameters such as sample surface preparation and test duration were evaluated to determine their effects on the measured rates. Additionally, results from an interlaboratory study (ILS) consisting of 12 laboratories from 11 different institutions are presented, where each laboratory performed 12 independent tests. When removing experimental outlier data, the 95% reproducibility limits for the SRCA method has no statistical difference with previously published standardized test methods used to determine the forward rate of glass dissolution. Overall, this paper describes steps necessary to perform the test method and provides the statistical calculations to evaluate test accuracy.

chemical durability

Accuracy of trace element determinations in alternate fuels

NASA-Lewis Research Center's work on accurate measurement of trace level of metals in various fuels is presented. The differences between laboratories and between analytical techniques especially for concentrations below 10 ppm, are discussed, detailing the Atomic Absorption Spectrometry (AAS) and DC Arc Emission Spectrometry (dc arc) techniques used by NASA-Lewis. Also presented is the design of an Interlaboratory Study which is considering the following factors: laboratory, analytical technique, fuel type, concentration and ashing additive.

Greenbauer-Seng, L. A.

Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

Luecke, William E.

A large interlaboratory electron diffraction study of monolayer graphene

Standardisation of data collection and analysis is essential to enable commercialisation of 2D materials in a wide range of technologies. Selected area electron diffraction (SAED) in the transmission electron microscope (TEM) is one of the key methods for distinguishing monolayer from bilayer and few-layer graphene by comparing the 1st and 2nd order diffraction spot intensities. Yet there are many factors that can affect the reliability of data collection and interpretation, causing the measurement of monolayer samples to deviate from the literature boundary condition of $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1 for monolayer graphene (1LG). Here we present the results of a large interlaboratory SAED comparison study, where 15 international laboratories measured and analysed nominally identical samples of chemical vapour deposited graphene. Large variations were observed in the measured ratios of diffraction spot intensities, with the largest variance associated with poor quality SAED data resulting from inadequate specimen handling and storage. To inform the reliable determination of monolayer thickness from SAED patterns we provide a description of best practice for specimen handling, TEM operation, data collection and analysis. This work was undertaken within VAMAS Technical Working Area 41: Graphene and related 2D materials—Project 9, the results of which have been directly incorporated into ISO/TS 21356–2 for the characterisation of graphene sheets. We find that when this methodology is followed, 1LG can be distinguished from bilayer or thicker material with high confidence where analysis of a single SAED pattern gives $I_{\{\bar{2}110\}}$$/$$I_{\{1\bar{1}00\}}$ < 1.2, even in the absence of precise specimen tilting.

2D materials

Interlaboratory comparison of fluorocarbons-11, -12, methylchloroform and nitrous oxide measurements

Measurements conducted by 19 participating laboratories were considered in the reported interlaboratory comparison study. The results show that there is considerable disagreement among laboratories regarding the absolute concentrations of all four trace gases (CCl3F, CCl2F2, H3CCl3, N2O). The magnitude of this disagreement is discussed. Laboratories in Group II showed considerable disagreement among themselves. Their results were scattered within large intervals of concentration. Laboratories in Group I (using common standards) were in excellent (+ or - 5%) agreement among themselves. A systematic disagreement was noted between Groups I and II laboratories. Generally, the mean values of concentrations determined from the measurements of Group II laboratories were lower than the mean values reported by Group I laboratories.

Rasmussen, R. A.

Round-robin analysis of highly depleted lithium for Generation IV nuclear reactor applications

Lithium reference materials containing unnaturally high abundances of 7 Li are not currently available, which poses quality control problems for highly depleted lithium materials (i.e., depleted in 6 Li) required for Generation IV nuclear reactors. This study presents an interlaboratory comparison of a lithium carbonate (NIST SRM924a) containing nominally natural isotopic abundances (~92.4 % Li-7) and a highly depleted lithium hydroxide material (~99.95 % Li-7). The natural lithium isotope abundances of NIST SRM924a are confirmed, and the 6 Li/ 7 Li ratio of the lithium hydroxide ranged from 0.000399 to 0.000436 with an average of 0.000428 ± 0.000023 (2SD, n = 9). Finally, going forward this material can be used as quality control for analytical work involving highly depleted lithium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Radiochronometric discordance in cast uranium metal: a multi-laboratory intercomparison exercise

Here, the model age of a nuclear material is crucial in nuclear forensic analysis. Uranium metals with complex production histories often exhibit discordant model ages from the 230 Th– 234 U and 231 Pa– 235 U chronometers. Recent studies involving targeted uranium metal castings have enhanced our understanding of decay product behavior during casting, aiding nuclear forensic interpretation. Building on this prior work, forensics laboratories at Atomic Weapons Establishment (AWE), Lawrence Livermore National Laboratory (LLNL), and Los Alamos National Laboratory (LANL) conducted an interlaboratory comparison to investigate spatial heterogeneity in uranium metal cast under controlled conditions. Each laboratory measured samples of a mixed feedstock and its corresponding cast product. This work furthers our understanding of discordant model ages and the use of discordance as a signature to enhance confidence in interpretations of radiochronometric data for nuclear forensics.

230Th/234U

Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

Lisagor, W. B.