Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of pressure test results of tube fittings for the potential application in cryo systems for helium leak rate reduction

Due to the nature of Helium, it is notoriously difficult to maintain a closed system without experiencing helium inventory loss through leakage in large tubing and piping runs. There are two standard fitting options readily available for piping and tubing assemblies, welded fittings or Swagelok ® . Welding is the best option for leak rate reduction, but more costly than Swagelok ® . A new style of fitting has come to the attention of BNL C-AD Cryo group, and a pressure test and leak rate analysis were performed to evaluate the viability of incorporating this new style fitting into current engineering design of warm helium tubing runs for the purpose of leak rate reduction.

43 PARTICLE ACCELERATORS↗

Geothermal well testing pressure prediction by using a hybrid transformer model system: FORGE well use case

Geothermal has huge potential to become an indispensable component in achieving the goal of sustainable energy economy, given its capability to provide consistent baseload power to the electric grid. Injection tests are crucial in geothermal energy system as they naturally help to evaluate reservoir properties, understand fluid flow and even enhance reservoir performance. In this research, we developed a hybrid model system that integrates machine learning (ML) regression, a physics-based mathematical model, and transformer deep learning. Trained and validated using FORGE injection test dataset, this system can forecast the pressure variations both upward and downward over time. The pressure prediction achieved prediction accuracy within 3-6% variance of true pressure values. The system can significantly save time and reduce costs by testing only a few cycles and then using model predictions for further analysis, instead of conducting additional real injection cycle tests. The developed model system also holds promise for designing injection test processes and maintaining well production in geothermal energy. Presented at the IMAGE ‘25 Conference led by Shell.

FORGE↗

Permeability scaling relationships of volcanic tuff from core to field scale measurements

A recent chemical explosive test in P-Tunnel at the Nevada National Security Site, Nevada, USA, was conducted to better understand how signals propagate from explosions in the subsurface. A primary signal of interest is the migration of gases that can be used to differentiate chemical from nuclear explosions. Gas migration is highly dependent on the rock permeability which is notoriously difficult to determine experimentally in the field due to a potentially large dependence on the scale over which measurements are made. Here, we present pre-explosion permeability estimates to characterize the geologic units surrounding the recent test. Permeability measurements were made at three scales of increasing size: core samples (≈2 cm), borehole packer system tests (≈1 m), and a pre-shot cavity pressurization test (> 10 m) across ten tuff units. Permeability estimates based on core measurements showed little difference from borehole packer tests. However, permeability in most rock units calibrated from cavity pressurization tests resulted in higher permeability estimates by up to two orders of magnitude. Here, we demonstrate that the scale of the measurement significantly impacts the characterization efforts of hydraulic properties in volcanic tuff, and that local-scale measurements (< 10 m scale) do not incorporate enough heterogeneity to accurately predict field-scale flow and mass transport.

Environmental sciences↗

Test Report for the Regulatory Testing of the Welded Isotek-SFC-W-3 Special Form Capsule

Two prototypes the welded ISOTEK-SFC-W-3 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the two welded ISOTEK-SFC-W-3 capsules. The test units were designated as TU-1 and TU-2. TU-1 was subjected to leak testing, percussion testing, and impact testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test on TU-1 was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). TU-2 was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in American National Standards Institute (ANSI) N14.5-2014. The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Response of Cr-Coated Zircaloy-4 Cladding to Pellet-Cladding Interactions

Chromium-coated zircaloy is a promising accident tolerant fuel (ATF) cladding design which can help mitigate high temperature oxidation. The mechanical response of the cladding during and after loading may be altered by the Cr coating throughout anticipated operational and accident occurrences such as a pellet-cladding interaction (PCI). In this work, the mechanical behavior of Cr-coated and uncoated cold worked stress-relieved (CWSR) Zircaloy-4 (Zry-4) cladding to PCI loading conditions are studied. Stress relaxation tests are performed on CWSR Zry-4 cladding using full-tube axial tension and internal pressurization to investigate mechanical anisotropy and rate-limiting deformation mechanisms of the uncoated Zry-4. These results are compared to internal pressure testing results of similar cladding with physical vapor deposition (PVD) Cr-coating to reveal how the Cr-coating affects the cladding mechanical response. Findings are discussed in the context of ATF cladding performance during operation and storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗

Burst pressure models and validations for thick-walled pipelines containing corrosion defects

Corrosion is one major threat to pipeline integrity. Over the past decades, many corrosion models have been developed for determining the remaining strength of corroded pipelines, including ASME B31.G, Modified B31.G, LPC, PCORRC and their modified models. All these corrosion models are applicable only to large diameter, thin-walled pipelines with a diameter to wall thickness ratio D/t ≥ 20. In practice, many pipelines have a small diameter and thick wall with a D/t ratio < 20, and thus an adequate corrosion model is needed for assessing remaining strength for corroded thick-walled pipelines. This paper briefly reviews the theoretical burst pressure models for defect-free thin and thick-walled pipelines and four representative corrosion assessment models for thin-walled corroded pipelines. On this basis, two modified corrosion models are proposed to thick-walled pipelines in terms of the average shear stress yield theory. To verify the proposed corrosion models, comprehensive validations are performed. Numerical validations include the elastic-plastic finite element analysis to determine burst pressure for pipelines without and with corrosion defects and the model evaluation using a large dataset of available FEA results of burst pressure for machined defects. Experimental validations include a set of burst pressure tests for defect-free thick-walled pipes with different thicknesses and the model evaluation using one large burst dataset for machined defects with flat bottoms and another large dataset for real corrosion defects with curved river bottom profiles. Both numerical and experimental validations show that the proposed corrosion models can more accurately predict the remaining strength for corroded thin and thick-walled pipelines.

Pipeline↗

Qualification of an Additively Manufactured Irradiation Capsule for the High Flux Isotope Reactor

As part of the Advanced Materials and Manufacturing Technologies (AMMT) Program’s work package Component Manufacturing and Demonstrations from AM 316 SS, irradiation capsules have been additively manufactured (AM) from 316H stainless steel for insertion into the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation capsules (commonly referred to as “rabbits”) have been successfully designed, fabricated, pressure tested, qualified, and inserted into the HFIR for irradiation and post-irradiation evaluation. Each rabbit consists of an AM housing and two standard AM end caps. The design is simple and amenable to geometric and material customization. This demonstration helps pave the way for acceptance of AM safety-critical components for nuclear energy applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Host Design for Carbon Capture and Regeneration in Porous Liquids

The demand for efficient gas capture technologies drives the exploration of porous liquids (PLs) as alternatives to traditional amine mixtures, which incur high operational costs due to energy-intensive regeneration processes. This research investigates the use of porous organic cages (POCs) within PLs to enhance gas capture and separation capabilities. We demonstrate that the flexibility of POCs under isostatic pressure facilitates the expulsion of captured gas molecules, enabling low-energy regeneration and the creation of an isostatic pressure testing capability for PLs. Additionally, a new CC3-OH POC derivative with scrambled hydroxides exhibits a twofold increase in CO 2 adsorption capacity, attributed to enhanced interactions between hydroxide linkers and CO 2 . Furthermore, we explore the stability of azobenzene-containing organic cages formed via imine and amine bonds, revealing that the flexible amine bond allows for more efficient E-Z isomerization. Our findings highlight the transformative potential of PLs and azobenzene-derived systems in gas separation technologies, paving the way for innovative low-energy regeneration pathways.

36 MATERIALS SCIENCE↗

Additively Manufactured Pressure Limiting Irradiation Capsule for the High Flux Isotope Reactor

The Advanced Materials and Manufacturing Technologies (AMMT) program previously demonstrated an additively manufactured (AM) irradiation capsule (commonly referred to as a “rabbit”) from 316H stainless steel (SS) for insertion into the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL)1. This report details efforts to design and fabricate an AM pressure limiting structure (PLS) into one of the end caps of a rabbit capsule and qualify it for insertion into HFIR. The PLS includes a thin cylindrical rupture wall, a shield, and internal supports to facilitate printing and ensure mechanical integrity. Its overall dimensions are 9-mm tall and 10-mm in diameter— equivalent to about one-fourth of the size of a AAA battery. The PLS maintains safe internal operating pressures for a rabbit capsule while in the reactor. Although this application is specific to HFIR, the approach lends itself to further applications in industrial, aeronautical, advanced space and power generation environments. Several PLS rabbits capsules have been successfully designed, fabricated, pressure tested, and qualified for future insertion into the HFIR for irradiation and post-irradiation evaluation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast permeability measurement for tight reservoir cores using only initial data of the one chamber pressure pulse decay test

Here, in this study, a mathematical model for fast determination of the permeabilities of tight rocks using measurements taken from the initial period of the One Chamber Pressure Pulse Decay (OC-PPD) test is presented. The model applies to measurements taken both before and after the pressure pulse front has reached the downstream end of the specimen. The analytical solutions for the pressure decay in the upstream chamber are derived based on a parabolic arc approximation of pore pressure distribution along the test specimen. This approximation allows converting the initial–boundary value problem of fluid diffusion in the specimen, governed by partial differential equations, to a system of ordinary differential equations that can be easily solved by explicit formulae. Thus, an explicit formula for the pressure decay rate is obtained, which enables inverse analysis of the initial experimental data to estimate the rock permeability. The proposed method expedites the pulse decay test as it does not require the system to reach equilibrium. The method is validated with three sets of experimental data of the OC-PPD test using helium as the diffusing fluid, for which the relative error of the permeability is found to be less than 6%. This method is particularly useful if the equilibrium time of the pulse decay test for rock specimens with permeabilities in the range of nano-Darcy takes hours or days.

early-time solution↗

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

Microstructural Engineering and Accelerated Test Method Development to Achieve Low Cost, High Performance Solutions for Hydrogen Storage and Delivery

This project made advancements in developing lower cost steel alloys with novel microstructural design for use in hydrogen refueling infrastructure such as storage, compressors, and dispensing components, and utilizing accelerated test methods to efficiently evaluate variations in alloy and microstructure design. The project specifically sought to design alloys with lower nickel contents to reduce alloy cost, which was accomplished through substituting manganese for nickel along with other alloy additions to control deformation characteristics known to be important for hydrogen embrittlement resistance. Through Mn substitutions for nickel, austenitic and duplex austenite-ferrite steels were successfully developed with lower cost than currently available commercial stainless steel products that are employed for hydrogen refueling infrastructure. The steels were processed to achieve comparable strength and toughness in hydrogen environments as the commercially available steels containing high Ni contents. To evaluate mechanical performance in hydrogen, a testing methodology was employed to compare ubiquitous laboratory testing using electrochemical hydrogen charging in a liquid electrolyte to less accessible high pressure gaseous testing. While the application of these steels is in high pressure gaseous environments, the electrochemical hydrogen charging tests produced comparable results. Additionally, the Los Alamos Neutron Scatting Center enabled characterization of deformation mechanisms of the steel alloys in the presence of hydrogen, which has been associated with steel alloy characteristics associated with hydrogen embrittlement. Finally, a fracture mechanics based test bed model was developed to predict the influence of hydrogen gas pressure and fatigue conditions on fatigue lifetimes of pressure vessel steels. Together, these developments can be employed to enable lower cost hydrogen fueling infrastructure and more reliable prediction of steel alloy components in hydrogen service conditions. In particular, the newly alloys have the potential to replace stainless steels, having demonstrated comparable performance at substantially reduced cost.

08 HYDROGEN↗

DME-to-Propane Mixture Effects on a Light Duty Compression Ignition Engine

Fuels that can be produced in a sustainable manner are of high interest because they can provide an essential step toward net zero emissions vehicles. This study examines the combustion of two such fuels, Dimethyl Ether (DME) and propane, in a compression ignition, 4-cylinder, 2.2L engine running with mixtures of DME-to-Propane ranging of 100%-0%, 85%-15%, 75%-25%, and 65%-35% by weight. Testing was conducted at 2000rpm - 100Nm, an important representative point in the FTP certification cycle. For each fuel mixture, conditions tested include sweeps of boost, EGR and injection pressure. Here, tests are mainly conducted at a constant combustion timing with CA10 of -1 deg with respect to TDC, with an engine controller combustion feedback system based on in-cylinder sampling of pressure. Trends of NOx, HC, and CO are similar for the range of DME-to-propane, from 100%-0% to 75%-25%. Boost and injection pressures had the most notable impact on the heat release traces. Higher boost, from stoichiometric to lean resulted in approximately a 3-5% increase on cycle efficiency. Fuel injection pressures resulted in about 1% gain per 200bar. Results also illustrated that EGR is effective in reducing NOx but causes notable degradation of cycle efficiency. The emissions for DME-propane mixtures with 65%-35% had a different trend, with CO and HC exceeding the runs with lower propane content by 2 to 3-fold. As propane content increases, the pressure rise rates become higher, and with 65%-35% mixtures, rates easily exceed 12bar/deg. The increased rise rates correlate with early injection timings but the rates can be reduced, with higher boost and lower injection pressures. The result of the approach, however, leads to lower thermal efficiencies, decreasing efficiency by over 5% between neat DME and the highest propane ratios.

Combustion and combustion processes↗

High pressure effects on EBC systems in high temperature environments

Environmental barrier coatings (EBCs) are designed to protect SiCfiber/SiCmatrix ceramic matrix composites (CMCs) in turbine engines by mitigating wear in high-temperature water vapor environments. The failure of EBCs is frequently attributed to the accelerated oxidation of the silicon bond coating layer when exposed to high-temperature steam, leading to the formation of a thickened thermally grown oxide (TGO). TGO growth increases interfacial stress, weakens adhesion, and results in coating spallation. Understanding the impact of high-temperature oxidation of EBC systems is essential for developing accurate lifespan models for turbine components, although pressurized oxidation testing is extremely sparse in the open literature. In this work, oxidation tests were performed on rare earth silicate EBCs coated onto SiC substrates under increased pressure conditions. The coated specimens were tested at 1100°C, 1200°C, and 1300°C at both 1 atm and 10 atm total pressure in steam environments. Subsequent characterization focused on the microstructural evolution of the EBC/Si/SiC system. The experimental findings indicated that TGO behavior is dependent on high-pressure conditions, with elevated pressure leading to an increase in oxide scale thickness and modifications in its morphology.

Ardrey, Kristyn [ORNL] (ORCID:0000000184407796)↗