Search NASA⌕ Search

SEARCH · Search NASA

Results for “protection devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Helpful Engineering's Universal Citizen Protection Device (UCPD)

The Universal Citizen Protection Device (UCPD) is a UV-based, filterless PPE concept developed by Helpful Engineering that aims to keep viral particles out of eyes, nose and mouth with a 99%+ reliability. The heart of the device is a concealed UV chamber that decontaminates all air going in and out of the PPE. The objective of this project was to provide measurements as evidence of proof of function of a representative prototype. Sandia utilized its aerosol characterization facility to measure the amount of virus that is inactivated by the device at representative flow rates and concentrations, using MS2 bacteriophage as the BSL-1 viral surrogate.

54 ENVIRONMENTAL SCIENCES↗

Gate protective device for insulated gate field-effect transistors

Device, which protects insulated gate field-effect transistors, improves reliability through utilization of layers of conductive material on top of each alternating semiconductor material region. Separation of layers is necessary to prevent shorting out junctions between alternating regions.

Sunshine, R. A.↗

Computational studies of a fluid spike as a leading edge protection device for shock-shock interference heating

The effectiveness of a fluid spike as a device to protect leading edges of hypersonic atmospheric flight vehicles from high aerothermal loads produced by complex shock-shock interference is studied. The two-dimensional Navier-Stokes equations are solved using an unstructured cell-centered, fully implicit, flux-difference split algorithm. Adaptively generated unstructured meshes are employed. A type IV shock-shock interference for Mach 8 flow on a cylindrical leading edge with and without a small contraflow supersonic jet (fluid spike) placed at two different locations on the body is solved. A typical flow past a blunt body with a type IV shock-shock interference produces very high pressures and heat fluxes on the leading edge. Present results indicate that a fluid spike displaces the bow shock further in front of the body and modifies the shock-shock interference pattern. This leads to reduced peak pressures and heat fluxes on the body.

Prabhu, Ramadas K.↗

Gate protective device for SOS array

Protective gate device consisting of alternating heavily doped n(+) and p(+) diffusions eliminates breakdown voltages in silicon oxide on sapphire arrays caused by electrostatic discharge from person or equipment. Diffusions are easily produced during normal double epitaxial processing. Devices with nine layers had 27-volt breakdown.

Meyer, J. E., Jr.↗

Gas sensor protection device and method

A gas sensor includes a sensor housing and a sensing element located within the sensor housing. The sensing element has a distal end and defines an axis. The gas sensor also includes a sensor protection device coupled to the sensor housing and at least partially surrounding the distal end of the sensing element. The sensor protection device includes a first member coupled to the housing, the first member having a generally rectangular cross-sectional shape in a plane perpendicular to the axis. The first member includes a gas inlet and a gas outlet. The sensor protection device also includes a second member coupled to the housing.

42 ENGINEERING↗

Limitations of Internal Protective Devices in High-Voltage/High-Capacity Batteries Using Lithium-Ion Cylindrical Commercial Cells

Most commercial cylindrical 18650 Lithium-Ion (Li-Ion) cells have two internal protective devices: the Positive Temperature Coefficient (PTC) and the Current Interrupt Device (CID). The PTC protects the cells under external short conditions and the CID protects the cells under overcharge conditions. While proven to be effective at the single cell and small-size battery levels, these devices do not always offer protection when used in high-voltage and high-capacity battery designs.

Limitations of Internal Protective Devices↗

Remote sensing applied to the evaluation of crop freeze protection devices

Thermal images from an aircraft-mounted scanner are used to evaluate the effectiveness of crop freeze protection devices. Fuel oil heaters, wind machines and irrigation systems are evaluated from flights at an altitude of 450 m over an experimental citrus grove of 1.5 hectares.

Sutherland, R. A.↗

Respiratory protective device design using control system techniques

The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

Burgess, W. A.↗

Risk Factors and Complications Associated with Difficult Retrieval of Embolic Protection Devices in Carotid Artery Stenting

Purpose: This study was designed to investigate the risk factors and complications of difficult retrieval (DR) of embolic protection devices (EPDs) in carotid artery stenting (CAS). Methods: A total of 195 consecutive patients who underwent CAS between December 2007 and March 2010 in a general hospital were enrolled and divided into two groups: with DR and without DR. The risk factors of DR were analyzed with univariate and multivariate analyses. The complications of DR were recorded and analyzed. Results: A total of 30 (15.4%) patients with DR of EPDs were observed, of whom EPDs were successfully retrieved in 29, and in 1 was it taken out by surgical treatment. The retrieval time was significantly longer in patients with DR (490.5 {+-} 143.9 s) than in patients without DR (157.2 {+-} 15.7 s, p = 0.000). Vasospasm was observed more frequently in patients with DR than in patients without DR (55.2% vs. 14.5%, p = 0.000). Intracranial compilations were more frequent in patients with DR than in those without DR (17.2% vs. 0.6%, p = 0.000). Calcified plaques, degree of residual stenosis, types of the stents, and tortuosity index (TI > 80 Degree-Sign) were all associated with DR. A logistic regression analysis indicated that calcified plaques (odds ratio (OR) = 6.5; p = 0.000) and TI > 80 Degree-Sign (OR = 18.8; p = 0.000) were independent predictors of DR. Conclusions: Calcified plaques and TI > 80 Degree-Sign may be related to DR in patients with CAS. DR may lengthen the retrieving time and increase the complications of the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Thrombin Injection Secured with an Embolic Protection Device as a Treatment for a Superior Mesenteric Artery Pseudoaneurysm

A pseudoaneurysm of the superior mesenteric artery (SMA) is a rare and life-threatening condition of various etiology. Even unruptured it can cause severe health problems or death. We report a 71-year-old male with a SMA pseudoaneurysm who was successfully treated with a transarterial thrombin injection secured with an embolic protection device used in carotid angioplasty. To our knowledge, this is the first case of a SMA pseudoaneurysm treated by this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Response of surge protection devices to fast rising pulses

Two types of lightning protection modules incorporating leadless (pill type) Zener like devices were evaluated with regard to their ability to suppress EMP induced transients. Two series of tests were performed to evaluate the ability of these modules to react to fast rate of rise ( 1Kv/ns) transients, and the attenuation introduced and the ability to limit damped sinusoid pulses which may be induced due to an EMP resulting from a nuclear detonation.

Mindel, I. N.↗