At least 19 records

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

It is important for manufacturers of electric vehicle charging connectors, inlets, and adapters to understand the thermal performance of their devices. Various standards, such as SAE J1772, SAE J3400, IEC 62196, UL 2251, and UL 2252, list temperature limits that charging hardware needs to meet. However, there are currently very limited standardized reference devices against which to measure connector performance, and those that do currently exist generally serve charging currents less than 500A. This can make determining whether a charging connector meets the appropriate temperature limits difficult. Additionally, as automakers and charging station suppliers transition from the SAE J1772 CCS charging standard to SAE J3400 NACS, a number of CCS-to-NACS and NACS-to-CCS adapters are entering the market. These devices are being produced both by well-known automakers/equipment OEMs and lesser-known third-party suppliers, across a wide range of price points and construction qualities. Though SAE J3400/1 and UL 2252 lay out standards for adapter construction, performance and overtemperature response, there is no guarantee that any particular adapter will follow these standards and react to overtemperature events appropriately. This work addresses these issues by developing and evaluating a set of CCS and NACS reference inlet devices to validate the performance of charging connectors in the 500-800A range. The work also evaluates the performance of multiple NACS-to-CCS and CCS-to-NACS charging adapters with respect to UL 2252 temperature limits and SAE J3400/1 overtemperature signaling criteria.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

A review of NLR's work in charging system reliability for charging inlets, connectors, and adapters. The review includes a detailed discussion on (a) the development of a reference device for the thermal performance of charging connectors and adapters, (b) evaluation of charging adapters and their thermal warning and shutdown response, (c) implications of side-load from real-world implementations, and (d) strengthening the conformance evaluation for end caps based on field data.

33 ADVANCED PROPULSION SYSTEMS↗

Degradation of Precision Reference Devices in Space Environments

This paper presents radiation test results for several different precision voltage devices. Their degradation is compared to that expected for the basic bandgap reference circuit, which is used as a theoretical benchmark, and uses only npn transistorss.

Precision↗

Magnetic-heading reference device

Inexpensive and reliable device is used in conjunction with fluidic-electronic wing-leveler system. Single magnetometer is placed so pilot can make adjustments in aircraft heading simply by rotating magnetometer itself.

Garner, H. D.↗

Magnetic heading reference

Devices are disclosed for vectorially summing two signals. In a first embodiment, the vectorial summation is implemented by a mechanical sin/cos mechanism in which a crank drives two linear potentiometers out of phase. In a second embodiment, a polarized light resolver generates the sin and cos functions. In a third embodiment, a printed circuit resolver generates the sin and cos functions.

Garner, H. D.↗

FET Junction Temperature Monitoring Using Novel On-Chip Solution

A novel junction temperature monitoring sensor is proposed and experimentally demonstrated for application in MOS-gate power devices. The sensor is created using the polycide gate electrode layer of the devices to create a temperature-sensitive resistor without any additional fabrication steps. The resistor is located on the field oxide with one end grounded at the device reference terminal to isolate it from the device current and voltage transients. It allows in-situ monitoring of the device junction temperature during active circuit operation. The technology has been implemented to monitor the junction temperature of Silicon Carbide Junction Barrier Schottky Field Effect Transistors (SiC JBSFETs) with the bi-directional FET (BiDFET).

Bidirectional switches, SiC bidirectional FET, BiD↗

Surface Acoustic Wave Monitor for Deposition and Analysis of Ultra-Thin Films

A surface acoustic wave (SAW) based thin film deposition monitor device and system for monitoring the deposition of ultra-thin films and nanomaterials and the analysis thereof is characterized by acoustic wave device embodiments that include differential delay line device designs, and which can optionally have integral reference devices fabricated on the same substrate as the sensing device, or on a separate device in thermal contact with the film monitoring/analysis device, in order to provide inherently temperature compensated measurements. These deposition monitor and analysis devices can include inherent temperature compensation, higher sensitivity to surface interactions than quartz crystal microbalance (QCM) devices, and the ability to operate at extreme temperatures.

Hines, Jacqueline H.↗

Exploring the effects of molecular beam epitaxy growth characteristics on the temperature performance of state-of-the-art terahertz quantum cascade lasers

This study conducts a comparative analysis, using non-equilibrium Green’s functions (NEGF), of two state-of-the-art two-well (TW) Terahertz Quantum Cascade Lasers (THz QCLs) supporting clean 3-level systems. The devices have nearly identical parameters and the NEGF calculations with an abrupt-interface roughness height of 0.12 nm predict a maximum operating temperature (T max ) of ~ 250 K for both devices. However, experimentally, one device reaches a T max of ~ 250 K and the other a T max of only ~ 134 K. Both devices were fabricated and measured under identical conditions in the same laboratory, with high quality processes as verified by reference devices. The main difference between the two devices is that they were grown in different MBE reactors. Our NEGF-based analysis considered all parameters related to MBE growth, including the maximum estimated variation in aluminum content, growth rate, doping density, background doping, and abrupt-interface roughness height. From our NEGF calculations it is evident that the sole parameter to which a drastic drop in T max could be attributed is the abrupt-interface roughness height. We can also learn from the simulations that both devices exhibit high-quality interfaces, with one having an abrupt-interface roughness height of approximately an atomic layer and the other approximately a monolayer. However, these small differences in interface sharpness are the cause of the large performance discrepancy. This underscores the sensitivity of device performance to interface roughness and emphasizes its strategic role in achieving higher operating temperatures for THz QCLs. We suggest Atom Probe Tomography (APT) as a path to analyze and measure the (graded)-interfaces roughness (IFR) parameters for THz QCLs, and subsequently as a design tool for higher performance THz QCLs, as was done for mid-IR QCLs. Our study not only addresses challenges faced by other groups in reproducing the record T max of ~ 250 K and ~ 261 K but also proposes a systematic pathway for further improving the temperature performance of THz QCLs beyond the state-of-the-art.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bifacial CdTe Solar Cells with Copper Chromium Oxide Back-Buffer Layer

Bifacial solar cells have the potential to maintain energy output higher than monofacial devices under unfavorable weather conditions. A transparent back-buffer layer which can passivate the interface and improve the minority carrier lifetime is critical in CdTe-based bifacial devices. Herein, solution-processed Cu x Cr y O z as a promising back-buffer for CdTe/CdS solar cells is demonstrated. The carrier lifetimes measured at the front and back of the device are 31.2 and 3.1 ns, respectively, which correspond to an increase of ≈38% and 138%, respectively, compared to the reference device. This dramatic improvement in lifetime results in a 100% increase in short-circuit current measured with backside illumination. The best bifacial device has efficiencies 7.6% and 12.5%, respectively, from back and front illumination, yielding a bifaciality factor of 0.60.

14 SOLAR ENERGY↗

The ordnance transfer interrupter: A new type of S & A device

A discussion is given in this paper of a new approach to the Safing and Arming of aerospace ordnance systems interconnected by detonation transfer lines, in which the conventional type of S&A device normally used for this purpose is replaced by a relatively simple electro-mechanical switching device, referred to as an 'Interrupter.' In this approach the Interrupter, which is interposed in the transfer line between the system initiator and output device, is completely passive in that it contains no pyrotechnic devices or materials. Being passive (therefore, non-initiating), the Interrupter is much less hazardous to handle and install, as well as being significantly less complex and costly than conventional S&A devices containing EED's and explosive leads. Details are presented relative to the design, development and qualification, by PS/EDD, of an ordnance transfer Interrupter intended for use on a commercial launch missile. This device, which is capable of simultaneously 'switching' multiple detonation transfer lines, incorporates a rod-type rotary barrier with independent transverse apertures for each transfer line. Barrier actuation is bi-modal, i.e., the barrier can be driven from safe-to-arm or from arm-to-safe positions by independent electro-mechanical actuators. The Interrupter described also features visual and remote status monitoring provisions and, in common with range-approved conventional S&A devices, a pre-flight safety locking mechanism functioned by a removable safing key.

Greenslade, John T.↗

Premission and postmission simulation studies of the foot-controlled maneuvering unit for Skylab experiment T-020

A Skylab experiment was conducted to study the maneuvering capabilities of astronauts using a relatively simple self-locomotive device, referred to as the foot-controlled maneuvering unit, and to evaluate the effectiveness of ground-based facilities simulating the operation of this device in weightless conditions of space. Some of the special considerations given in the definition and development of the experiment as related to the two ground-based simulators are reviewed. These simulators were used to train the test subjects and to obtain baseline data which could be used for comparison with the in-flight tests that were performed inside the Skylab orbital workshop. The results of both premission and postmission tests are discussed, and subjective comparisons of the in-flight and ground-based test conditions are presented.

Hewes, D. E.↗

The foot-controlled maneuvering unit: Summary report on Skylab experiment T-020

Skylab experiment T-020 was conducted to study the maneuvering capabilities of astronauts using a relatively simple experimental self-locomotive device, referred to as the foot-controlled maneuvering unit, and to evaluate the effectiveness of ground-based facilities simulating the operation of this device in weightless conditions of space. The final results as presented of this experiment which includes comparison of the tests performed during missions SL-3 and SL-4 of the Skylab with those performed on the simulators. Some of the results of this experiment and those of Skylab experiment M509, which employed an experimental hard-controlled maneuvering unit, are discussed in terms of the development of a possible future operational maneuvering system.

Hewes, D. E.↗

Steric Impediment of Ion Migration Contributes to Improved Operational Stability of Perovskite Solar Cells

The operational instability of perovskite solar cells (PSCs) is understood to mainly originate from the migration of ionic species (or charged defects) under a potential gradient. Compositional engineering of the “A” site cation of the ABX3 perovskite structure has been shown to be an effective route to improve the stability of PSCs. Here, the effect of size-mismatch-induced lattice distortions on the ion migration energetics and operational stability of PSCs is investigated. It is determined that the size mismatch of the mixed “A” site composition films and devices leads to a steric effect to impede the migration pathways of ions to increase the activation energy of ion migration, which is demonstrated through multiple theoretical and experimental evidence. Consequently, the mixed composition devices exhibit significantly improved thermal stability under continuous heating at 85 °C and operational stability under continuous 1 sun illumination, with an extrapolated lifetime of 2011 h, compared to the 222 h of the reference device.

14 SOLAR ENERGY↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Cooperative control of a DNA origami force sensor

Abstract Biomolecular systems are dependent on a complex interplay of forces. Modern force spectroscopy techniques provide means of interrogating these forces, but they are not optimized for studies in constrained environments as they require attachment to micron-scale probes such as beads or cantilevers. Nanomechanical devices are a promising alternative, but this requires versatile designs that can be tuned to respond to a wide range of forces. We investigate the properties of a nanoscale force sensitive DNA origami device which is highly customizable in geometry, functionalization, and mechanical properties. The device, referred to as the NanoDyn, has a binary (open or closed) response to an applied force by undergoing a reversible structural transition. The transition force is tuned with minor alterations of 1 to 3 DNA oligonucleotides and spans tens of picoNewtons (pN). The DNA oligonucleotide design parameters also strongly influence the efficiency of resetting the initial state, with higher stability devices (≳10 pN) resetting more reliably during repeated force-loading cycles. Finally, we show the opening force is tunable in real time by adding a single DNA oligonucleotide. These results establish the potential of the NanoDyn as a versatile force sensor and provide fundamental insights into how design parameters modulate mechanical and dynamic properties.