Characterization and modeling of radiation effects NASA/MSFC semiconductor devices

A literature review of the near-Earth trapped radiation of the Van Allen Belts, the radiation within the solar system resulting from the solar wind, and the cosmic radiation levels of deep space showed that a reasonable simulation of space radiation, particularly the Earth orbital environment, could be simulated in the laboratory by proton bombardment. A 3 MeV proton accelerator was used to irradiate CMOS integrated circuits fabricated from three different processes. The drain current and output voltage for three inverters was recorded as the input voltage was swept from zero to ten volts after each successive irradiation. Device parameters were extracted. Possible damage mechanisms are discussed and recommendations for improved radiation hardness are suggested.

Kerns, D. V., Jr.↗

Total-dose radiation effects data for semiconductor devices, volume 1

Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. Data are presented by JPL for various NASA space programs on diodes, bipolar transistors, field effect transistors, silicon-controlled rectifiers, and optical devices. A vendor identification code list is included along with semiconductor device electrical parameter symbols and abbreviations.

Price, W. E.↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Total-dose radiation effects data for semiconductor devices: 1985 supplement, volume 1

Steady-state, total-dose radiation test data are provided, in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 provides total-dose radiation test data on integrated circuits. Volume 1 of this 1985 Supplement contains new total-dose radiation test data generated since the August 1, 1981 release date of the original Volume 1. Publication of Volume 2 of the 1985 Supplement will follow that of Volume 1 by approximately three months.

Martin, K. E.↗

Total-dose radiation effects data for semiconductor devices (1989 supplement)

Steady state, total dose radiation test data are provided for electronic designers and other personnel using semiconductor devices in a radiation environment. The data are presented in graphic and narrative formats. Two primary radiation source types were used: Cobalt-60 gamma rays and a Dynamitron electron accelerator capable of delivering 2.5 MeV electrons at a steady rate.

Martin, Keith E.↗

Total-dose radiation effects data for semiconductor devices. 1985 Supplement. Volume 2, part B

Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 (Parts A and B) provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done steady-state 2.5-MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose. All data were generated in support of NASA space programs by the JPL Radiation Effects and Testing Group (514).

Martin, K. E.↗

Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose.

Martin, K. E.↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

Failure Analysis of Heavy-Ion-Irradiated Schottky Diodes

In this paper, we use high- and low-magnification optical microscope images, thermal infrared camera images, and scanning electron microscope images to identify failure locations in heavy-ion-irradiated Schottky diodes. After failures have been identified, the parts were cross-sectioned to describe the structure of the failures and energy dispersive x-ray spectroscopy was used to characterize the materials in the failure structures.

Radiation effects↗

Device Responses and Effects

This section of the short course discusses radiation effects in semiconductor devices. This is a broad topic, and it is not possible to cover all aspects in a course of this length. The approach that will be used is to briefly review basic mechanisms and device responses, and to go into more detail for new topics such as latchup that have not been covered in as much detail in previous short courses.

radiation effects semiconductor devices semiconduc↗

Sandia National Laboratories FY20 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY20 the Energetic Neutrons campaign increased the number and complexity of experiments, continued collaborations with external organizations, and generated knowledge that supports SNL’s National Security mission. In FY20 the Energetic Neutrons campaign was executed by an early career team led by a new PI. The SNL team members were trained to take over new responsibilities during the shot day to increase the number and complexity of experiments in the campaigns. Also, in FY20 for the first time the Energetic Neutrons campaign had a graduate student contributing with pre and post-irradiation characterizations at SNL of the semiconductor devices irradiated at OMEGA. In FY20 SNL collaborated with the Air Force Nuclear Weapons Center (AFNWC) and supported experiments related to radiation effects in semiconductor devices. SNL also gave the opportunity to ride along to Los Alamos National Laboratory and multiple scientists from MIT and LLE. SNL continued using the last two generations of the Neutron Effects Diagnostics (NEDs) to field active and passive experiments but also redesigned the latest generation of the NEDs to accommodate larger components and improve the vacuum sealing as shown in figure 1a. The redesigned NEDs allowed SNL to perform active tests of a high voltage (HV) PCB for the first time at OMEGA; where signals before, during and after the irradiation were recorded. The HV PCB installed in one of the SNL NEDs is shown in figure 1b where a 3D-printed nosecone was used to check for mechanical and electrical interference. Passive irradiations of multiple components were followed up with leakage current, gain measurements and radiation-induced defect characterization.

42 ENGINEERING↗