Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Extra-solar astronomy with a 2.4 m normal incidence X-ray telescope at 0.1 arcsec resolution

The advantages and disadvantages for astrophysical observations of a normal incidence X-ray telescope are considered. The baseline configuration is for a 2.4 meter diameter mirror operating at 0.23-0.28 keV with a CCD detector having a pixel size equivalent to 0.1 arcsec. This resolution enables X-ray images to be made comparable to those of Space Telescope in the optical and to those of the Very Large Array in the radio for a large number of sources. Specific examples cover essentially the entire range of astrophysics.

Elvis, M.↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗