Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Alterations in dose and lineal energy spectra under different shieldings in the Los Alamos high-energy neutron field

Nuclear interactions of space radiation with shielding materials result in alterations in dose and lineal energy spectra that depend on the specific elemental composition, density and thickness of the material. The shielding characteristics of materials have been studied using charged-particle beams and radiation transport models by examining the risk reduction using the conventional dose-equivalent approach. Secondary neutrons contribute a significant fraction of the total radiation exposure in space. An experiment to study the changes in dose and lineal energy spectra by shielding materials was carried out at the Los Alamos Nuclear Science Center neutron facility. In the energy range of about 2 to 200 MeV, this neutron spectrum is similar in shape within a factor of about 2 to the spectrum expected in the International Space Station habitable modules. It is shown that with a shielding thickness of about 5 g cm(-2), the conventional radiation risk increases, in some cases by as much as a factor of 2, but decreases with thicknesses of about of 20 g cm(-2). This suggests that care must be taken in evaluating the shielding effectiveness of a given material by including both the charged-particle and neutron components of space radiation.

NASA Discipline Radiation Health↗

Dose-response relationship for light intensity and ocular and electroencephalographic correlates of human alertness

Light can elicit both circadian and acute physiological responses in humans. In a dose response protocol men and women were exposed to illuminances ranging from 3 to 9100 lux for 6.5 h during the early biological night after they had been exposed to <3 lux for several hours. Light exerted an acute alerting response as assessed by a reduction in the incidence of slow-eye movements, a reduction of EEG activity in the theta-alpha frequencies (power density in the 5-9 Hz range) as well as a reduction in self-reported sleepiness. This alerting response was positively correlated with the degree of melatonin suppression by light. In accordance with the dose response function for circadian resetting and melatonin suppression, the responses of all three indices of alertness to variations in illuminance were consistent with a logistic dose response curve. Half of the maximum alerting response to bright light of 9100 lux was obtained with room light of approximately 100 lux. This sensitivity to light indicates that variations in illuminance within the range of typical, ambient, room light (90-180 lux) can have a significant impact on subjective alertness and its electrophysiologic concomitants in humans during the early biological night.

Clinical Trial↗

Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

Single Event Effects↗

Micron MT29F128G08AJAAA 128GB Asynchronous Flash Memory Total Ionizing Dose Characterization Test Report

The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.

Flash Memory↗

ISSI IS46DR16640B-25DBA25 DDR2 SDRAM Total Ionizing Dose Characterization Test Report

The purpose of this testing is to characterize the ISSI IS46DR16640B-25DBA25 parameter degradation for total dose response. This test’s purpose is to evaluate and compare lot date codes for sensitivity. In the test, the device is exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits or addresses, and overall chip and die health are investigated to determine which lot is more robust. These parameters directly affect the functionality of the memory within a system and may determine thresholds necessary to mitigate failure.

Total Ionizing Dose (TID)↗

U309 N-Channel Silicon Junction Field Effect Transistor Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize the InterFET Corporation U309 for total dose response. This test shall serve as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. The U309 is a discrete Junction Field Effect Transistor (JFET). High dose rate (HDR) irradiations were performed in this test so that the device susceptibility to Total Ionizing Dose (TID) could be determined.

Total Ionizing Dose (TID)↗

The noise dose range of the X-59 estimated from propagation simulations

NASA’s X-59 aircraft will soon be flown in a series of low-boom community noise surveys across the USA. Community test experimental designs will include noise dose schedules, which require an estimate of the noise dose range that X-59 can produce. To determine the dose range, propagation simulations using NASA’s PCBoom code were completed using CFD-generated X-59 C612A near-field pressure data for an on-design condition (Mach 1.4 at 53,200 feet) and two off-design conditions (Mach 1.4 at 46,000 ft and Mach 1.3 at 43,000 ft). Near-field data at four cardinal aircraft headings were propagated through one year of realistic atmospheric profiles from the Climate Forecast System Version 2 database at several USA locations. Statistics of the mean and range of the Perceived Level (PL) of the booms in the inner 40 km of each carpet as well as the carpet width were computed. Results indicate the typical inner carpet mean PL is approximately 70-87 dB depending on the aircraft condition. The typical PL range across the inner carpet is 6-8 dB (on-design) and 5-13 dB (off-designs). The carpet widths ranged from 32-55 km. Understanding these quantities for various flight and atmospheric conditions is important for planning X-59 community noise surveys.

X-59↗

DirectINJECT: Dosing Systems for Concentrated Liquid Biocides

Reliable and mass-efficient techniques for biocide dosing are necessary to enable residual microbial control in spacecraft potable water systems. DirectINJECT is an approach to provide ultra-low flow rate injection of stable aqueous biocide concentrate solution (e.g., highly soluble silver salt). This method has the benefit of low consumable mass and is insensitive to the chemistry of the target water. With a 40 g Ag+/liter solution, required dosing rates would be ~1 μl/minute during water processing (for a system similar to the ISS WPA), requiring only approximately 20 ml/crew-year of concentrate. The performance of three dosing systems were identified and characterized: pressure-driven flow through a robust micro-capillary tube with a solenoid valve shut-off, a miniature peristaltic pump, and a multi-piston pump with integrated valving. Several potential system reliability concerns are addressed including prevention or segregation of gas bubbles in the concentrate reservoirs as well as long-term materials compatibility and mechanical life.

silver↗

Galactic cosmic ray heavy primary secondary doses

Results of a calculation which estimates the heavy primary secondary doses from cosmic ray interaction data are reported. The incident galactic cosmic ray heavy primary spectrum is represented as the sum of helium, nitrogen, magnesium, and iron components. The incident iron nuclei are allowed to fragment into lesser Z secondaries, which are assumed to travel in the same direction and start with the same energy per nucleon as the interacting primary. The total emergent particle energy spectra and dose are then presented for the galactic heavy primary spectrum incident on aluminum and tissue slabs. The importance of the fragmentation parameters assumed is also evaluated. The total dose from the heavy primaries and their secondaries is found to be reduced by only a factor of two in 20 g/sq cm of shielding.

Wilkinson, M. C.↗

A real time spectrum to dose conversion system

A system has been developed which permits the determination of dose in real time or near real time directly from the pulse-height output of a radiation spectrometer. The technique involves the use of the resolution matrix of a spectrometer, the radiation energy-to-dose conversion function, and the geometrical factors, although the order of matrix operations is reversed. The new technique yields a result which is mathematically identical to the standard method while requiring no matrix manipulations or resolution matrix storage in the remote computer. It utilizes only a single function for each type dose required and each geometric factor involved.

Farmer, B. J.↗

Radiation measurements and doses at SST altitudes

Radiation components and dose equivalents due to galactic and solar cosmic rays in the high atmosphere, especially at SST altitudes, are presented. The dose equivalent rate for the flight personnel flying 500 hours per year in cruise altitudes of 60,000-65,000 feet (18-19.5 km) in high magnetic latitudes is about 0.75-1.0 rem per year averaged over the solar cycle, or about 15-20 percent of the maximum permissible dose rate.

Foelsche, T.↗

Irradiate-anneal screening of total dose effects in semiconductor devices

An extensive investigation of irradiate-anneal (IRAN) screening against total dose radiation effects was carried out as part of a program to harden the Mariner Jupiter/Saturn 1977 (MJS'77) spacecraft to survive the Jupiter radiation belts. The method consists of irradiating semiconductor devices with Cobalt-60 to a suitable total dose under representative bias conditions and of separating the parts in the undesired tail of the distribution from the bulk of the parts by means of a predetermined acceptance limit. The acceptable devices are then restored close to their preirradiation condition by annealing them at an elevated temperature. IRAN was used when lot screen methods were impracticable due to lack of time, and when members of a lot showed a diversity of radiation response. The feasibility of the technique was determined by testing of a number of types of linear bipolar integrated circuits, analog switches, n-channel JFETS and bipolar transistors. Based on the results of these experiments a number of device types were selected for IRAN of flight parts in the MJS'77 spacecraft systems. The part types, screening doses, acceptance criteria, number of parts tested and rejected as well as the program steps are detailed.

Stanley, A. G.↗

Electron, electron-bremsstrahlung and proton depth-dose data for space-shielding applications

A data set has been developed, consisting of depth-dose distributions for omni-directional electron and proton fluxes incident on aluminum shields. The principal new feature of this work is the accurate treatment, based on detailed Monte Carlo calculations, of the electron-produced bremsstrahlung component. Results covering the energy region of interest in space-shielding calculations have been obtained for the absorbed dose (a) as a function of depth in a semi-infinite medium, (b) at the edge of slab shields, and (c) at the center of a solid sphere. The dose to a thin tissue-equivalent detector was obtained as well as that in aluminum. Various results and comparisons with other work are given.

Seltzer, S. M.↗

Total-dose radiation effects data for semiconductor devices: 1985 supplement, volume 1

Steady-state, total-dose radiation test data are provided, in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 provides total-dose radiation test data on integrated circuits. Volume 1 of this 1985 Supplement contains new total-dose radiation test data generated since the August 1, 1981 release date of the original Volume 1. Publication of Volume 2 of the 1985 Supplement will follow that of Volume 1 by approximately three months.

Martin, K. E.↗

Dose protraction studies with low- and high-LET radiations on neoplastic cell transformation in vitro

The effects of the low- and high-LET radiation (by X-rays, Co-60, and heavy ions) on the transformation of neoplastic cells were studied using cultured C3H10T1/2 mouse embryo cells. The transformed colonies in the confluent cell monolayers were recognized as focuses composed of highly polar fibroblastic multilayered criss-cross arrays of densely stained cells. For the low-LET radiation, there was a decrease in cell killing and cell transformation frequency when cells were irradiated with fractionated doses and at a low dose rate, indicating that cultured mammalian cells can repair both subtransformation and potential transformation lesions. No sparing effect, however, was found for the high-LET radiation. An enhancement of cell transformation was observed for low-dose/rate argon (400 MeV/u; 120 keV/micron) and iron particles (600 MeV/u; 200 keV/micron). The molecular mechanism for this enhancement effect is not known.

Yang, Tracy Chui-Hsu↗

Radiation environments and absorbed dose estimations on manned space missions

The dose and dose-equivalent estimates that astronauts might be expected to receive in space were assessed for the development of new radiation protection guidelines, considering several space mission scenarios. These scenarios included a 90-day LEO mission at 450 km altitude with orbital inclinations appropriate for NASA's Space Station (28.5, 57, and 90 deg), a 15-day sortie to GEO, and a 90-day lunar mission. All the missions contemplated would present space travelers with dose equivalents between 5 and 10 rem to the blood-forming organs, assuming no encounter with a large solar particle event; a large particle event could add considerable exposure for all scenarios except for the one at 28.5 orbital inclination. Adequate shielding must be included to guard against the radiation produced by such events.

Curtis, S. B.↗

Radiation dose and shielding for the space station

Significant differences in dose prediction for Space Station arise depending on whether or not the magnetic field model is extrapolated into the future. The basis for these calculations is examined in detail, and the importance of the residual atmospheric layer at altitudes below 1000 km, with respect to radiation attenuation, is emphasized. Dosimetry results from Shuttle flights are presented and compared with the computed results. It is recommended that, at this stage, no extrapolation of the magnetic field into the future be included in the calculations. A model adjustment, to replace this arbitrary procedure, is presented. Dose predictions indicate that, at altitudes below 500 km and at low inclination, and with nominal module wall thickness (0.125 in. aluminum), orbit stay times of 90 days in Space Station would result in quarterly radiation doses to the crew, which are well within present limits for both males and females. Countermeasures would be required for stay times of a year or more and the measure of increasing shielding is examined.

Mccormack, Percival D.↗

Reliability of equivalent sphere model in blood-forming organ dose estimation

The radiation dose equivalents to blood-forming organs (BFO's) of the astronauts at the Martian surface due to major solar flare events are calculated using the detailed body geometry of Langley and Billings. The solar flare spectra of February 1956, November 1960, and August 1972 events are employed instead of the idealized Webber form. The detailed geometry results are compared with those based on the 5-cm sphere model which was used often in the past to approximate BFO dose or dose equivalent. Larger discrepancies are found for the later two events possibly due to the lower numbers of highly penetrating protons. It is concluded that the 5-cm sphere model is not suitable for quantitative use in connection with future NASA deep-space, long-duration mission shield design studies.

Shinn, Judy L.↗