Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Otoconia as test masses in biological accelerometers: what can we learn about their formation from evolutionary studies and from work in microgravity?

This paper reviews previous findings and introduces new material about otolith end organs that help us to understand their functioning and development. In particular, we consider the end organs as biological accelerometers. The otoconia are dealt with as test masses whose substructure and evolutionary trend toward calcite may prove significant in understanding formation requirements. Space-flight helps illuminate the influence of gravity, while right-left asymmetry is suggested by study of certain rat strains.

Non-NASA Center↗

ISLES: Probing Extra Dimensions Using a Superconducting Accelerometer

In string theories, extra dimensions must be compactified. The possibility that gravity can have large radii of compactification leads to a violation of the inverse square law at submillimeter distances. The objective of ISLES is to perform a null test of Newton s law in space with a resolution of one part in 10(exp 5) or better at 100 microns. The experiment will be cooled to less than or equal to 2 K, which permits superconducting magnetic levitation of the test masses. To minimize Newtonian errors, ISLES employs a near null source, a circular disk of large diameter-to-thickness ratio. Two test masses, also disk-shaped, are suspended on the two sides of the source mass at a nominal distance of 100 microns. The signal is detected by a superconducting differential accelerometer. A ground test apparatus is under construction.

Paik, Ho Jung↗

Silicon bulk micromachined, symmetric, degenerate vibratorygyroscope, accelerometer and sensor and method for using the same

When embodied in a microgyroscope, the invention is comprised of a silicon, four-leaf clover structure with a post attached to the center. The whole structure is suspended by four silicon cantilevers or springs. The device is electrostatically actuated and capacitively detects Coriolis induced motions of the leaves of the leaf clover structure. In the case where the post is not symmetric with the plane of the clover leaves, the device can is usable as an accelerometer. If the post is provided in the shape of a dumb bell or an asymmetric post, the center of gravity is moved out of the plane of clover leaf structure and a hybrid device is provided. When the clover leaf structure is used without a center mass, it performs as a high Q resonator usable as a sensor of any physical phenomena which can be coupled to the resonant performance.

Tang, Tony K.↗

Attitude determination with three-axis accelerometer for emergency atmospheric entry

Two algorithms are disclosed that, with the use of a 3-axis accelerometer, will be able to determine the angles of attack, sideslip and roll of a capsule-type spacecraft prior to entry (at very high altitudes, where the atmospheric density is still very low) and during entry. The invention relates to emergency situations in which no reliable attitude and attitude rate are available. Provided that the spacecraft would not attempt a guided entry without reliable attitude information, the objective of the entry system in such case would be to attempt a safe ballistic entry. A ballistic entry requires three controlled phases to be executed in sequence: First, cancel initial rates in case the spacecraft is tumbling; second, maneuver the capsule to a heat-shield-forward attitude, preferably to the trim attitude, to counteract the heat rate and heat load build up; and third, impart a ballistic bank or roll rate to null the average lift vector in order to prevent prolonged lift down situations. Being able to know the attitude, hence the attitude rate, will allow the control system (nominal or backup, automatic or manual) to cancel any initial angular rates. Also, since a heat-shield forward attitude and the trim attitude can be specified in terms of the angles of attack and sideslip, being able to determine the current attitude in terms of these angles will allow the control system to maneuver the vehicle to the desired attitude. Finally, being able to determine the roll angle will allow for the control of the roll ballistic rate during entry.

Garcia-Llama, Eduardo↗

Micro-Accelerometers Monitor Equipment Health

Glenn Research Center awarded SBIR funding to Ann Arbor, Michigan-based Evigia Systems to develop a miniaturized accelerometer to account for gravitational effects in space experiments. The company has gone on to implement the technology in its suite of prognostic sensors, which are used to monitor the integrity of industrial machinery. As a result, five employees have been hired.

Source record↗

Analysis of Accelerometer Data from a Woven Inflatable Creep Burst Test

Accelerometers were used to montor an inflatable test article during a creep test to failure. The test article experienced impulse events that were classified based on the response of the sensors and their time-dependent manifestation. These impulse events required specialized techniques to process the structural dynamics data. However, certain phenomena were defined as worthy of additional study. An assessment of one phenomena (a frequency near 1000Hz) showed a time dependent frequency and an amplitude that increased significantly near the end of the test. Hence, these observations are expected to drive future understanding of and utility in inflatable space structures.

James, George H.↗

Single-Axis Accelerometer

A single-axis accelerometer includes a housing defining a sleeve. An object/mass is disposed in the sleeve for sliding movement therein in a direction aligned with the sleeve's longitudinal axis. A first piezoelectric strip, attached to a first side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The first piezoelectric strip includes a first strip of a piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A second piezoelectric strip, attached to a second side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The second piezoelectric strip includes a second strip of the piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A voltage sensor is electrically coupled to at least one of the first and second piezoelectric strips.

Tucker, Dennis Stephen↗

Single Event Effect Testing of the Analog Devices ADXL354 3-Axis MEMS Accelerometer

The Analog Devices ADXL354 3-AXIS MEMS accelerometer was tested for single-event effects, both destructive and non-destructive. The device was characterized for single-event upset (SEU) sensitivity and evaluated for any possibility of single-event latchup (SEL), single-event dielectric rupture (SEDR) and single-event functional interrupts (SEFI). Single-event transient (SET) response was also monitored.

Single-Event Effect (SEE)↗

High sensitivity single-axis MEMS accelerometer with bilateral flexures

A microelectromechanical systems (MEMS) accelerometer that has high sensitivity to motion along the z axis is discussed. The device includes two symmetrical sets of bilateral, diametrically opposed high aspect ratio flexures that tether a movable proof mass to the frame of the device. The flexures are designed in such a way as to restrict movement of the proof mass along the x and y axes but readily allow motion along the z axis. More specifically, when the device experiences an acceleration along the x or y axes, the proof mass is restricted from moving because some of the bilateral, diametrically opposed flexures are in compression and others are in tension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cutting force estimation from machine learning and physics-inspired data-driven models utilizing accelerometer measurements

Monitoring cutting forces for process control may be challenging because force measurements typically require invasive instrumentation. To remedy this situation, two new methods were recently developed to estimate cutting forces in real time based on the use of on-machine accelerometer measurements. One method uses machine learning, while another uses a physics-inspired data-driven approach, to generate a model that estimates cutting forces from on-machine accelerations. The estimated forces from both approaches were compared against cutting force data collected during various milling operations on several machine tools. The results reveal the advantages and disadvantages of each model to estimate real-time cutting forces.

Vogl, Greg↗

Missile Captive Carry Monitoring using a Capacitive MEMS Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. One of the most significant exposures to vibration occurs when the missile is being carried by an aviation platform, which is a condition known as captive carry. If the duration of captive carry exposure could be recorded during the missile’s service life, several advantages could be realized. Missiles that have been exposed to durations outside the design envelop could be flagged or screened for maintenance or inspection; lightly exposed missiles could be selected for critical mission applications; and missile allocation to missions could be based on prior use to avoid overuse. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing health monitoring systems to assess and improve reliability of missiles during storage and field exposures. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the HELLFIRE II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the HELLFIRE II missile to record the cumulative hours the host missile has been in captive carry mode and thereby assess the overall health of the missile. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to identify captive carry, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

47 OTHER INSTRUMENTATION↗

Quantum accelerometer: Distinguishing inertial Bob from his accelerated twin Rob by a local measurement

A single quantum system, such as the Unruh-DeWitt detector, can be used to determine absolute acceleration by local measurements on a quantum field. To show this, we consider two kinematically indistinguishable scenarios: an inertial observer, Bob, measuring the field of a uniformly accelerated cavity, and his noninertial twin, Rob, accelerating and making measurements in a stationary cavity. We find that these scenarios can be distinguished in the nonrelativistic regime only by measurements on highly excited massive fields, allowing one to detect the noninertialness of the reference frame.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feeling the Pull: A Study of Natural Galactic Accelerometers. II. Kinematics and Mass of the Delicate Stellar Stream of the Palomar 5 Globular Cluster

We present two spectroscopic surveys of the tidal stellar stream of the Palomar 5 globular cluster undertaken with the VLT/FLAMES and AAT/AAOmega instruments. We use these data in conjunction with photometric data presented in the previous contribution in this series to classify the survey stars in terms of their probability of belonging to the Palomar 5 stellar stream. We find that high-probability candidates are only found in a very narrow spatial interval surrounding the locus of the stream on the sky. PanSTARRS RR Lyrae stars in this region of the sky are also distributed in a similar manner. The absence of significant “fanning” of this stellar stream confirms that Palomar 5 does not follow a chaotic orbit. Previous studies have found that Palomar 5 is largely devoid of low-mass stars, and we show that this is true also of the stellar populations along the trailing arm out to 6{sup ∘}. Within this region, which contains 73% of the detected stars, the population is statistically identical to the core, implying that the ejection of the low-mass stars occurred before the formation of the stream. We also present an updated structural model fit to the bound remnant, which yields a total mass of 4297±98M{sub ⊙} and a tidal radius 0.145±0.009 kpc. We estimate the mass of the observed system including the stream to be 12,200 ± 400 M {sub ⊙}, and the initial mass to have been ∼47,000 ± 1500 M {sub ⊙}. These observational constraints will be employed in our next study to model the dynamics of the system in detail.

79 ASTRONOMY AND ASTROPHYSICS↗